6 Hydraulic module. Thermoplan fox2
Reklam
Reklam
6 Hydraulic module
6.1 Error messages Hydraulic module
Error no. / picture
TX0101
Text
NTC coffeeboiler open
Technical manual
Cause
Problem with NTC in coffee boiler
SECTION 6
Fix
Check NTC and if necessary exchange
TX0115
TX0116
TX0125
TX0141
TX0151
TX0154
Flow error
Overtime error
Too low water flow
Product is not dispensed correctly because of too low water flow
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
1. Dispense product again
2. Check flowmeter
3. Check pump
Waterflow error
NTC coffee boiler short-circuit
No water pressure or flowmeter defective
NTC on coffee boiler had a short circuit
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
Change NTC on coffee boiler
No waterflow detected
Milk pump: no pulse
No water pressure or flowmeter defective
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
Milk pump not recognised
TX0155
TX0161
TX0201
Water pump: no pulse
Please wait
Cold start rinse
Please press rinse key
Milk pump not recognised
Machine rinses Wait until rinse is finished
Rinse for start- and warm-up of machine
Press rinse key
© 2011 by Thermoplan AG, Änderungen vorbehalten
REV-1 6.36
İndir