IFM SM2x04 Series magnetic-inductive flow meters provide real-time monitoring of liquid media, measuring flow rate, volume, and temperature. With IO-Link communication, the devices offer advanced connectivity and data exchange capabilities. Their compact design simplifies installation, while the intuitive interface enables easy parameter configuration and operation. They excel in industrial applications involving conductive liquids, providing precise and reliable flow measurement solutions.
advertisement
5 Installation
► Avoid deposits, accumulated gas and air in the pipe system�
The unit can be installed irrespective of the orientation if the following is ensured:
-No air bubbles can form in the pipe system�
-The pipes are always completely filled�
5.1 Recommended installation locations
Example of an optimised installation:
1
F
► Install the unit so that the measuring pipe is completely filled�
► Arrange for inlet and outlet pipe lengths� Disturbances caused by bends, valves, reductions, etc� are compensated for� It applies in particular: no shut-off and control devices are allowed directly in front of the unit�
2
5 x D
F
2 x D
S S
S = disturbance; D = pipe diameter; F = flow direction
10
advertisement
Related manuals
advertisement
Table of contents
- 4 1 Preliminary note
- 4 1�1 Symbols used
- 4 1�2 Warning signs used
- 4 2 Safety instructions
- 5 3 Functions and features
- 6 4 Function
- 6 4�1 Processing of the measured signals
- 6 4�2 Direction of flow
- 6 4�2�1 Determination of the direction of flow (Fdir)
- 6 4�3 Consumed quantity meter
- 7 4�4 Empty pipe detection
- 7 4�5 Analogue function
- 9 4�6 Measured value damping (dAP)
- 9 4�7 Low flow cut-off (LFC)
- 9 4�8 Simulation
- 9 4�9 IO-Link
- 10 5 Installation
- 10 5�1 Recommended installation locations
- 11 5�2 Not recommended installation position
- 12 5�3 Grounding
- 13 5�4 Installation in pipes
- 14 6 Electrical connection
- 14 7 Operating and display elements
- 15 8 Menu
- 15 8�1 Process value display
- 16 8�2 Main menu, Extended functions
- 18 8�3 Basic settings
- 20 8�4 Min/max memory – Empty pipe – Simulation
- 21 9 Set-up
- 22 10 Parameter setting
- 23 10�1 Parameter setting in general
- 24 10�1�1 Switching between the menu levels