Technical Data Digital Recorder

10.7.3

Materials

Front frame / door made of metal die-cast, abrasion-proof matt chrome coating

Extended diaphragm seal / rear panel: galvanized sheet metal

Protective glass plate in front of display

10.8

Human interface

10.8.1

Display elements

Display: STN colour graphic display with 126 mm screen diagonal (5"), 76,800 pixels

(320 x 240)

Display modes (signal grouping of channels, i.e. 10 groups of 10 channels): graphic signal display of digital channels, digital combinations and relay statuses. Digital display, event list (limit values / power failure), history display in curve form with display of digital statuses, date and time, overview window, device information such as memory information.

Signal analysis: quantities, operating times, display of the last 7 evaluations

(intermediate, daily, monthly or annual evaluations) directly at the device.

10.8.2

Saving data

Data storage:

• Selectable memory cycle 1s / 2s / 3s / 4s / 5s / 10s / 20s / 30s / 1min / 2min / 4min /

5min.

• Permanent storage of the set device parameters in the internal Flash memory (nonvolatile)

Internal memory:

Buffering

10 years for program / measured value memory (Flash memory, nonvolatile), internal memory 1024 or 2048 kSRAM

Permanent storage of the set device parameters in the internal Flash memory (nonvolatile)

External memory:

• Cyclic copying of the measured data for archiving on 3.5" / 1.44 MB disk

10.8.3

Real time clock

Switchable summer / normal time automatic

Buffering

4 years (at ambient temperature of 15 to 25 °C / 59 to 77 °F)

10.9

Certificates and approvals

10.9.1

CE mark

The measuring system meets the legal requirements of the EC directives. The manufacturer confirms successful testing of the device by affixing the CE mark.

132