FU-Parameter . YASKAWA GA500 Serie, GA500 series

YASKAWA GA500 series is a versatile AC drive that offers a wide range of features and capabilities, making it suitable for a variety of applications. With its compact design and easy-to-use interface, the GA500 is ideal for both new and experienced users. Some of the key features of the GA500 include:

  • Sensorless vector control for high-performance operation
  • Built-in PLC functionality for advanced control
  • Multiple communication options for easy integration
  • Compact design for space-saving installation
  • Easy-to-use keypad interface for simple operation

Whether you're looking for a basic AC drive or a more advanced solution, the GA500 has the features and capabilities to meet your needs.

PDF
Document
FU-Parameter . YASKAWA GA500 Serie, GA500 series | Manualzz

Advertisement

Advertisement

/

Advertisement

Key features

  • Sensorless vector control for high-performance operation

  • Built-in PLC functionality for advanced control

  • Multiple communication options for easy integration

  • Compact design for space-saving installation

  • Easy-to-use keypad interface for simple operation

Frequently asked questions

The GA500 series offers a power range from 0.1 to 30 kW.

The GA500 series offers a variety of input voltage options, including 200 V single-phase, 200 V three-phase, and 400 V three-phase.

The GA500 series offers a wide range of output frequency limits, from 0.1 Hz to 600 Hz.

User questions

H D

Jennifer H.

How is the input AC supply voltage parameter changed in the Yaskawa GA500?

The input AC supply voltage is modified by adjusting parameter E1-01 (Input AC Supply Voltage).

R G

Jennifer R.

How is the Yaskawa GA500 drive started up?

The drive can be set up using the General-Purpose Setup Mode.

R G

Jennifer R.

What considerations are necessary when operating the drive with a 380 V motor?

It is crucial to operate the frequency inverter within the input voltage specification range indicated on the drive's nameplate.

R G

Jennifer R.

What function does Parameter A1-02 relate to?

Parameter A1-02 relates to the device's fault reset procedure.

R G

Jennifer R.

What information is provided regarding the Safe Disable Circuit?

The manual provides information about the Safe Disable Circuit in the YASKAWA AC Drive GA500.

R G

Jennifer R.

How is the Yaskawa GA500 drive put into operation?

The Yaskawa GA500 drive can be put into operation using the "General-Purpose Setup Mode," which contains only the most commonly used parameters to help configure the drive more easily.

R G

Jennifer R.

What is the function of parameter A1-02?

Parameter A1-02 relates to the device's fault reset procedure.

R G

Jennifer R.

Where is information about the Safe Disable Circuit located in the manual?

Details regarding the Safe Disable Circuit can be found in the manual under the Safe Disable Input section.

G N

James G.

How to configure the GA500 inverter to be controlled as a slave from another inverter?

To operate as a slave, set parameter b1-01 (Frequency Reference Selection) to 1 (Analog Input), 2 (Modbus), or 4 (Pulse Train), and set parameter b1-02 (Run Command Selection) to 1 (Digital Input) or 2 (Modbus), depending on the master inverter's output signal.

V R

Jennifer V.

What does the EF error code mean and how can it be resolved?

The EF error code indicates an External Fault triggered via an MFDI (Multi-Function Digital Input) terminal. It is caused by an external device signal or an unused terminal incorrectly configured for an external fault. To resolve it, remove the source of the fault or verify the MFDI terminal settings.

Y P

Robert Y.

Which parameters are used to set motor nameplate data on the GA500 drive?

Motor nameplate data is set using parameters E2-01 (Rated Current for standard motors), E5-03 (for PM motors), or E9-06. Alternatively, use Auto-Tuning modes T1-04 or T2-06 to automatically configure these values.