Troubleshooting

5-1 Troubleshooting

Section 5-1

5-1-1 Connection Errors

Problem

The POWER indicator is not lit.

The Monitor is blank.

The Video Monitor image is not clear.

Probable cause

The Power Supply is not connected properly.

The supply voltage is not 24 VDC

+10%

/

-15%

.

The power to the Monitor is not ON.

The Monitor Cable is not connected properly.

The Monitor is malfunctioning.

The power supply capacity is insufficient.

There is electrical noise entering from the power supply or cables.

The Monitor Cable is not correctly connected.

The Console Cable is not correctly connected.

Cannot make key inputs from the

Console.

Camera images do not appear on the screen (for Cameras with Light

Source).

Camera images do not appear on the screen (when a standard CCTV lens and lighting are used).

The indicators do not turn ON (for

Cameras with Light Source).

The Camera Cable is not correctly connected.

The lighting cable is not properly connected to the Camera.

The lens cap has not been removed.

The Camera Cable is not properly connected.

The lens iris is opened or closed too far.

The shutter speed is not suitable.

The lighting method is not suitable.

The lighting cable is not correctly connected to the Camera.

Power is not being supplied to the F160.

When using a Camera with Intelligent Lighting, the DIP switch pins are not set to 0.

When using an F160-S2 Camera with Intelligent Lighting, the number of lines is not set to 484.

5-1-2 Menu Operation Errors

Problem

The measurement results are not displayed on the Monitor.

Probable cause

The F160 is not in Monitor or Run mode.

5-1-3 Parallel Interface Errors

Trigger signals (input signals) are not received.

Problem Probable cause

The cables are not correctly wired.

The signal line is disconnected.

The status of communications can be checked with the I/O monitor.

The F160 is not in Monitor or Run mode.

Signals cannot be output externally.

The trigger signal has not been input.

The cables are not correctly wired.

The signal line is disconnected.

The status of communications can be checked with the I/O monitor.

The F160 is not in Run mode.

40

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

FAQ

5-1-4 Serial Interface Errors

Problem

No communications are possible.

The Unit operates well initially, but after a while there is no response from the F160.

Cannot perform menu operations from the computer.

Section 5-2

Probable cause

The cables are not correctly wired.

The F160's communications specifications do not match those of the external device.

The communications mode was not selected under System/Communications settings/Serial .

Select Normal , Host link , or Menu operations under RS-232C/Operating mode . (Normal is no-protocol.)

The status of communications can be checked with the I/O monitor.

The reception buffer on the external device (e.g., computer) is full. Check that settings allow the data to be properly received.

The communications mode was not set to Menu operations in the System/Communications settings/Serial settings.

5-2 FAQ

5-2-1 Cameras

Question

When more than one Camera is connected, is the timing of the shutter trigger pulse synchronized?

Answer

F160-S2, F150-S1

The timing is not synchronized. In order to prevent light interference from other Cameras, the timing is staggered by a displacement time

(tD). The displacement time depends on the type of Camera connected.

F160-S2: tD = Approx. 500 µ s

F150-S1: tD = Approx. 1 ms

When using a strobe, the timing of the strobe trigger signal is staggered in the same way as the shutter trigger pulse.

Can more than one internally synchronized Camera be connected?

Can the F150-LT10A Light be connected to the F160-S2?

Camera 0

Camera 1 tD

( : Shutter trigger pulse turns ON)

Other Cameras

The timing is synchronized. There is no displacement time.

No. Only one internally synchronized Camera (F200-S) can be connected. Connect it to camera connector 0. The internally synchronized

Camera cannot be used in 2-line random trigger mode, which requires

2 Cameras.

Yes. In addition to the Camera and Light, provide the appropriate lens.

20-mm field of vision: F150-LE20

50-mm field of vision: F150-LE50

41