Zone Trigger Mode. Honeywell IntelliPath Series, IntelliPath LTE-IC, IntelliPath LTE-IV
विज्ञापन
विज्ञापन
LTE-I Installation and Setup Guide
Zone Trigger Mode
UL / ULC
The LYNX controls have not been evaluated with this communicator.
There are six input zones available on the communicator. Each zone is selectable for +V, -V, or
EOLR trigger. The first zone input can detect both pulsed and steady signals if connected to a bell output. Additionally, the first zone input can be programmed to detect a single pulse
(characteristic of a Panic indication on the Lynx, LynxR or LynxR-EN control by enabling the Lynx
Panic option). If the programming option “Lynx Panic” is enabled, the communicator reports an alarm on zone 3. No restores are reported for this zone. If this option is selected, the second physical zone input is ignored.
When using Zone Trigger mode, messages are sent in ADEMCO High-Speed format.
Zones 3, 4, 5, 6 and 7 are voltage trigger inputs located on TB1 pins 6-10. If the Lynx Panic feature is being used, do not connect zone 3 (the second physical zone input).
Refer to Table 3-4 for Zone Trigger Mode programming and follow the prompts that pertain to
Zone Trigger Mode. A check mark (
✔
) indicates whether the prompt applies to that mode.
Press the [ENTER] key to begin programming and f ollow the prompts for the mode of operation being programmed.
NOTE: The central station can remotely block access to local device programming. If this has been done, the following prompt appears:
Access to Prog
Mode Denied
1
2
3
PROMPTS
Strt Prog Mode?
Y/N_
Enter Password
Program Device?
Y/N_
Table 3-4: Programming for Zone Trigger mode.
OPTIONS
[Y], [N]
DESCRIPTION
Enters programming mode.
[0-9, A-F, N, S, T, X, Y]
[Y], [N]
4
5
6
Create Password?
Y/N_
Change Password?
Y/N_
Enter Password
[Y], [N]
[Y], [N]
[0-9, A-F, N, S, T, X, Y]
If a password has been previously assigned, this prompt appears.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
The next prompt appears.
To begin programming the communicator, press [Y] and go to
Prompt 10: "Device Mode."
To create a password if none has been assigned, press [N] and go to Prompt 5: Create Password.
To change an existing password, press [N] and go to Prompt 6:
"Change Password."
Passwords can be used to protect account and programming information.
If no password has been assigned, this prompt appears after pressing [N] at the "Program Device?" prompt.
If a password is desired, press [Y] and go to Prompt 7: "Enter
Password."
If a password has already been assigned, this prompt appears after pressing [N] at the "Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without entering a new one, answer [Y] to the "Change Password?" prompt, then press the
[Enter] key when prompted for the new password and its confirmation.
This prompt is displayed if [Y] was pressed in Prompt 5 or 6. Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
26
7
Section 3: Programming the Communicator
PROMPTS
Verify Password
OPTIONS DESCRIPTION
[0-9, A-F, N, S, T, X, Y] Re-enter the password as confirmation.
If the password doesn't match the first entry, the following is displayed followed by the "Exit Prog. Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed directly.
8
9
Exit Prog. Mode?
Y/N_
Comm Path Choice
(IP&Cell)
[Y], [N]
[ESC]
IP&Cell
IP
Cell
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the
Exiting Programming Mode paragraph in this section.
Press the [space] key to scroll through the communication path choices. Press [ENTER] to select.
For maximum reliability, select IP&Cell, and ensure the Internet is connected using the Ethernet cable.
NOTE : After going from a “Cell” only com path choice to an “IP” only choice, Prompt 71: “DHCP” will default to No.
10 Device Mode
(ECP)_
ECP
Zone Trig.
Press the [space] key to scroll through the modes of operation.
Press [ENTER] to select mode.
IMPORTANT , if ECP device mode is desired, use
Table 3-2
for programming.
Important Information Regarding Multi-Mode
NOTE: In order for the Multi Mode, Remote Access, and Keypad Address programming fields to appear an account must be created in the AlarmNet 360 website and “Remote Access” must be enabled for the comm device.
In Zone Trigger mode, the options for Multi-Mode are "Enabled" or "Disabled." If enabled, whenever a zone on the communication device is triggered, a corresponding email message is sent INSTEAD of normal central station reports.
Cover tamper will send email event 8. All communication device system events (such as power loss, low battery, Telco, etc.) are still sent to AlarmNet.
Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to events triggering the hardwired zones.
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central Station reporting of critical events (alarms, troubles, etc.).
UL
Multi-Mode has not been evaluated by UL.
11
Multi Mode
(Disabled)_
Enabled
Disabled
Enable if you want system events sent by email to the user.
Disable for normal alarm processing.
12
Important Information Regarding Primary Account (Questions 11-13)
Account information is provided by the central station administrator.
Primary City ID
(??)_
[01-99] Enter the 2-digit primary city ID, 01-99 (decimal).
13 Primary CS ID
(???)
[01-FE]
Enter the 2-digit primary central station ID number, 01-FE (HEX).
14 Primary Sub ID
(????)
[0001-9999]
Enter the 4-digit subscriber account number, 0001-9999 (decimal).
UL / ULC
Remote access has not been evaluated by UL or ULC.
16 RemoteAccess
Y/N (N)_
17 Direct Wire Y/N
(N)_
[Y], [N]
[Y], [N]
Press [Y] to allow the end user to access their system via a website. Availability of this service is controlled by the dealer via the web-based programming tool on the AlarmNet 360 website.
Applies only to VISTA-128BP/250BP and FBP Series control panels, and FA1660C and 1700C Series control panels.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 16: "Remote Access" is disabled, skip to
Prompt 19: "Supervision."
27
LTE-I Installation and Setup Guide
18
PROMPTS
Keypad Address
(28)_
[01-30]
OPTIONS
19
20
Supervision
(24 Hours)_
IP & Cell or Cell Only:
None
30 Day
24 Hours
IP only :
None
30 Day
24 Hours
6 minutes
3 minutes
90 seconds
_ _ _ _ _ _ _
Additional options for CN only.
1 Hr
3 Min
90 seconds
75 seconds
Cell Rollover Y/N
(N)_
[Y], [N]
21
22
Cell 24Hr Tst Y/N
(N)_
Old Alarm Time
10 Minutes_
[Y], [N]
10 Min
15 Min
30 Min
1 Hr
2 Hrs
4 Hrs
8 Hrs
12 Hrs
24 Hrs
DESCRIPTION
This address must be programmed if using either the Remote
Access feature or Direct Wire downloading. Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an alpha keypad in the control panel or an AUI (Advanced User Interface) type device, if a full enhanced graphic interface to the system is desired and the control panel supports it. DO NOT connect an actual keypad (or any other device) assigned to this address.
2. This address must be unique from the "Device Address" entered in Prompt 15, and cannot equal that device address plus 1 (one) if using 2-4204 mode.
The AlarmNet network must hear at least one supervisory message from the communicator during this supervision period; otherwise,
AlarmNet notifies the central station that a communication failure has occurred. (If the supervision period is changed after registration, you must re-register the communicator.)
Press the [space] key to scroll through choices.
UL : For IP + Cell set to 24 Hrs. For IP only set to 3 Min. For Cell only set to 24 Hrs.
A loss of communications is treated as an Alarm condition.
ULC : Must be set to" CN UL Line Lvl 3" for ULC-S304 Active Level
3 or ULC-S559 Active Fire installations. All other commercial applications must be set to "24 Hrs".
This prompt appears only if comm. path is set to IP & Cell.
If enabled, all messages (including AlarmNet network supervisory messages) are sent over the cell network in the event of an Internet failure.
If disabled, all messages (except AlarmNet network supervisory messages) are sent automatically over the cell network in the event of an Internet failure.
UL/ULC : Must be set to "Y" if 24 hours is selected in Prompt: 19:
Supervision. Must be set to "N" for ULC-S304 Active Level 3 or
ULC-S559 Active Fire installations where CN UL Line Lvl 3 is selected.
IMPORTANT WARNING: If set to "Y", AND Prompt 19:
Supervision is set to occur less than every 24 hours, this can result in data overage charges on your monthly bill.
This prompt appears only if comm. path is set to IP & Cell.
If enabled a message is sent every 24 hrs over cell to verify proper operation. If it fails, a Periodic Comm Test Failure message will be sent over Ethernet.
UL/ULC: Must be set to "Y".
Sets how long an undeliverable alarm is retried for delivery to the central station. If the message is not validated, it is retried until the old alarm time is reached or the message is validated.
Press the [space] key to scroll through choices.
UL/ULC: Must be set to 10 minutes.
28
23
24
25
26
27
28
29
Section 3: Programming the Communicator
PROMPTS
IP Flt Time
(60 mins)_
Cell Flt Time
(60 mins)_
Notify Panel Of_
(Neither Fault)_
Flt Rel ON Y/N
(N)_
Pwr Loss Rpt
Y/N (Y)_
Low Bat Rpt Y/N
(Y)_
Tamper Rpt Y/N
(Y)_
[00-99]
[00-99]
OPTIONS DESCRIPTION
This prompt appears only if comm. path includes IP.
In the event there is a loss of contact with the network over the
Ethernet connection, enter the time delay (in minutes) before the communicator notifies the central station. IP failure will always be sent to the central station as Primary Communication Path Failure.
UL/ULC: Must be one (01) minute.
This prompt appears only if comm. path includes Cell.
In the event the communicator detects a communication path failure, enter the time delay (in minutes) before the communicator notifies the central station. A cell failure will always be sent to the central station as Secondary Communication Path Failure.
UL/ULC: Must be one (01) minute.
[Neither fault]
[Both IP and Cell Faults]
This prompt appears only if comm. path is set to IP & Cell.
If "Both IP and Cell Fault" is selected, the device will only notify the control panel if both communication paths fail, but will always send notification of either failure to the central station.
NOTE: The fault relay output (if programmed) will be triggered only if "Both IP and Cell Faults" is selected. (If the "Cell Fault Time" and
"IP Fault Time" options are set to zero, faults will not be reported.)
Press the [space] key to scroll through choices.
UL/ULC: Must be set to "Both IP and Cell Faults".
[Y], [N] If enabled, the fault open collector output is normally energized to ground, and de-energizes (open circuit) in the event of a communicator fault. For conditions that trip the fault relay refer to
Supervision Features
in Section 1.
Set to [Y] if fail-safe mode is desired.
See
Wiring the Fault Relay
in Section 2.
UL/ULC: Must be set to "Y".
[Y], [N]
[Y], [N]
[Y], [N]
Sends a primary power loss report to the central station within 1-3 hours after its detection. A restore report is sent within 1-3 hours after power is restored.
UL Standard Installations (using transformer and battery) : Must be set to "Y".
ULC Commercial Fire & Burglary Installations (powered from the control panel) : Must be set to "N."
Sends a low-battery report when a low battery condition exists. A low-battery restore is automatically sent when the low battery condition clears.
UL Standard Installations (using transformer and battery) : Must be set to "Y".
ULC Commercial Fire & Burglary Installations (powered from the control panel) : Must be set to "N."
Sends a tamper report when the communicator detects a tamper condition. A tamper restore is automatically sent when the tamper condition clears.
UL/ULC: Must be set to "Y".
29
LTE-I Installation and Setup Guide
30
PROMPTS
Lynx Panic Y/N
(N)_
[Y], [N]
OPTIONS DESCRIPTION
Applies only if used with a Lynx, LynxR or
LynxR-EN controls where the communicator (or LRR) trigger is connected to the communicator’s zone terminal.
Reports a Panic alarm on zone 3 when the communicator detects a single pulse on zone 1.
No restores are generated for a Panic alarm.
UL/ULC: The LYNX controls have not been evaluated with this communicator.
Important Information Regarding Zone Input Options
Zone Trigger Mode provides six hardwire zone input triggers by making connections to the communicator’s zone terminals and programming the appropriate zone trigger options below. Zones are numbered 1-7, with zone 2 serving as a reporting zone only (see Bell Output Zone below).
Bell Output Zone 1 (and 2): The zone 1 terminal can detect both pulsed and steady signals. If connecting the bell output to the communicator zone causes a bell fault on the control panel, enable the "Trip Inputs 1 or 2" option. The communicator reports an alarm on zone 1 (fire) when it detects a pulsed signal and an alarm on zone 2 (burglary) when it detects a steady signal.
UL/UL: Use of the Bell output is not supported.
Telco Zone and Open/Close Zone: Dedicated zones can be assigned as the Telco fault zone and/or an open/close
(arm/disarm) reporting zone. When triggered, these zones report a Telco line fault or open/close report respectively, in
ADEMCO High-Speed format. Connect the appropriate trigger from the control panel to the selected zone input for each of these options.
Input Trigger Types: Triggering of each zone input can be programmed to cause an alarm under one of the following conditions:
(V+), where a positive voltage causes an alarm for normally low connections (voltage trigger, NO, NC)
(V–), where a ground trigger causes an alarm for normally high connections (open collector, NO, NC)
(EOLR) End of Line Resistor, where the input is supervised by a 2K EOL resistor. The zone can be triggered by open collector, voltage trigger, NO, NC.
UL/UL: Set V+ to inverted, and V– as non-inverted.
Inverted Trigger: Zones can be programmed for inverted trigger, where the alarm and normal states of the zones are inverted; this can serve a fail-safe supervisory purpose for certain installations.
Restore and Delayed Reports: Zone inputs can be programmed for restore reporting, and for delayed reporting (NOT for
UL installations) allowing time for the user to abort false alarms.
UL/ULC: Zone restoral must be enabled.
Report Only if Armed option: To help eliminate redundant reports, zone alarms can be restricted to report only if a conditional zone is triggered (armed). If this feature is desired, the conditional zone is automatically used as the “arming” zone. Connect the appropriate control panel trigger to the conditional (arming) zone. The trigger must be programmed as necessary in the control panel.
The conditional (arming) zone on the communicator is a different dedicated zone for each programming mode, as follows:
Mode
Zone Trigger
Conditional (Arming) Zone
7
IMPORTANT: If any zone (zones 1-6 in zone trigger mode) is set for Report Only if Armed, the conditional (arming) zone becomes unavailable for reporting (as it is reserved for the “arming” trigger connection).
31
PROMPTS
Trip Inputs 1or2 w/Bell Out (N)_
[Y], [N]
OPTIONS DESCRIPTION
Use if the zone 1 connection to the control panel's bell output causes a bell fault at the control panel.
NOTES:
1. If used, EOLR trigger type is not available for zones 1 and 3.
2. Do not use with Lynx controls.
30
Section 3: Programming the Communicator
32
33
34
PROMPTS
Telco Zone
(0)_
Open/Close Zone
(0)_
Zn1 Trigger Type
(V+)_
Zone Trig: [3-7]
[0] = not used
(V+)
(V–)
OPTIONS
Zone Trig: [3-7]
[0] = not used
(EOLR)
DESCRIPTION
See Important Information Regarding Zone Input Options on previous page.
Enter the zone number to be used for Telco line fault reports.
This zone assignment must be unique from the open/close zone selected in Prompt 33.
Zone Trigger Mode: If any zone is programmed for "report only if armed," zone 7 cannot be used. If Lynx Panic is enabled, zone 3 cannot be used.
NOTE: Connect the Telco line fault output (or relay output programmed for "Telco line fault") to the Telco zone.
Enter the zone number to be used for open/close (arm/disarm) reports.
This zone assignment must be unique from the Telco zone selected in Prompt 32.
Zone Trigger Mode: If any zone is programmed for "report only if armed," zone 7 cannot be used as an open/close zone. If
Lynx Panic is enabled, zone 3 cannot be used.
NOTE: Connect an open/close (arm/disarm) trigger (or relay output) from the control panel to the open/close zone.
Selects the triggering method for this zone input.
Press the [space] key to scroll through the choices.
UL/UL: V+ must be set as inverted and V– as non-inverted.
Enables restore reporting for zone 1.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 1.
UL/ULC: Must be set to “00.”
Report alarms on zone 1 ONLY if the conditional zone (zone 7 in zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 1.
35
36
37
38
39
40
41
Restore Zn1 Y/N
(Y)_
Delay Zn1 (secs)
(00)_
Rpt Zn1 ONLY if
Armed (N)_
Invert Zn2 Y/N
(N)_
Restore Zn2 Y/N
(Y)_
Delay Zn2 (secs)
(00)_
Rpt Zn2 ONLY if
Armed (N)_
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
Inverts the alarm and normal states of the zone 2 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 2.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 2.
UL/ULC: Must be set to “00.”
Reports alarms on zone 2 ONLY if the conditional zone (zone 7 in zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 2.
42
43
44
45
If Lynx Panic is enabled, then skip to Prompt 46: "Rpt Zn3 ONLY if Armed."
Zn3 Trigger Type
(V+)_
Invert Zn3 Y/N
(N)_
Restore Zn3 Y/N
(Y)_
Delay Zn3 (secs)
(00)
(V+)
(V–)
(EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as non-inverted.
Inverts the alarm and normal states of the zone 3 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 3.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 3.
UL/ULC: Must be set to “00.”
31
LTE-I Installation and Setup Guide
46
47
PROMPTS
Rpt Zn3 ONLY if
Armed (N)_
Zn4 Trigger Type
(V+)_
OPTIONS
[Y], [N]
(V+)
(V–)
(EOLR)
48
49
50
51
52
53
54
55
56
57
58
59
60
61
Invert Zn4 Y/N
(N)_
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
(00)
Rpt Zn4 ONLY if
Armed (N)_
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
Zn5 Trigger Type
(V+)_
(V+)
(V–)
(EOLR)
Invert Zn5 Y/N
(N)_
Restore Zn5 Y/N
(Y)_
Delay Zn5 (secs)
(00)_
Rpt Zn5 ONLY if
Armed (N)_
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
Enable Zn6 Y/N
(N)_
Zn6 Trigger Type
(V+)_
[Y], [N]
(V+)
(V–)
(EOLR)
[Y], [N] Invert Zn6 Y/N
(N)_
Restore Zn6 Y/N
(Y)_
Delay Zn6 (secs)
(00)_
[Y], [N]
[01-15]
[00] = no delay
62
63
Rpt Zn6 ONLY if
Armed (N)_
Enable Zn7 Y/N
(N)_
[Y], [N]
[Y], [N]
DESCRIPTION
Reports alarms on zone 3 ONLY if the conditional zone (zone 7 in zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 3.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as non-inverted.
Inverts the alarm and normal states of the zone 4 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 4.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 4.
UL/ULC: Must be set to “00.”
Reports alarms on zone 4 ONLY if the conditional zone (zone 7 in zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 4.
Selects the triggering method for this zone input.
Press the [space] key to scroll through the choices.
UL: V+ must be set as inverted and V– as non-inverted.
Inverts the alarm and normal states of the zone 5 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 5.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 5.
UL/ULC: Must be set to “00.”
Reports alarms on zone 5 ONLY if the conditional zone (zone 7 in zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 5.
Enables alarm reporting for zone 6.
If [N], skip to Prompt 63: "Enable Zn7."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as non-inverted.
Inverts the alarm and normal states of the zone 6 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 6.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 6.
UL/ULC: Must be set to “00.”
Reports alarms on zone 6 ONLY if the conditional zone (zone 7 in zone trigger mode) is triggered (armed).
If [N], always reports alarms on zone 6.
Enables alarm reporting for zone 7.
If [N], skip to Prompt 71: "Use DHCP."
32
Section 3: Programming the Communicator
64
PROMPTS
Zn7 Trigger Type
(V+)_
(V+)
(V–)
OPTIONS
(EOLR)
DESCRIPTION
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
UL/ULC: V+ must be set as inverted and V– as non-inverted.
Inverts the alarm and normal states of the zone 7 trigger; otherwise uses normal input signal.
65
66
67
Invert Zn7 Y/N
(N)_
Restore Zn7 Y/N
(Y)_
Delay Zn7 (secs)
(00)_
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
Enables restore reporting for zone 7.
Zone Trigger mode: This question will only be displayed if zone
7 is not used as the conditional (arming) trigger zone.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 7.
Zone Trigger mode: This question will only be displayed if zone
7 is not used as the conditional (arming) trigger zone.
UL/ULC: Must be set to “00.”
Reports alarms on zone 7 ONLY if the conditional zone is triggered (armed).
If [N], always reports alarms on zone 7.
68 Rpt Zn7 ONLY if
Armed (N)_
[Y], [N]
69
70
Restore Zn8 Y/N
(Y)_
Delay Zn8 (secs)
(00)_
[Y], [N]
[01-15]
[00] = no delay
Enables restore reporting for zone 8.
UL/ULC: Must be set to “Y.”
Defines the reporting delay in seconds for zone 8.
UL/ULC: Must be set to “00.”
Prompts 71-77 appear only if communication path includes IP.
71 Use DHCP Y/N
(Y)_
[Y], [N]
Dynamically allocates the IP addresses (recommended); then skip to Prompt 76: "Enable Pwr Save". If [N], uses fixed IP addresses.
72 NIC IP Address:
255.255.255.255_
12 digit: xxx.xxx.xxx.xxx
Enter the 4-part address for this device. The 4 parts of the address must be separated by spaces (displayed as periods in
Review mode).
73 Subnet Mask:
255.255.255.255_
12 digit: xxx.xxx.xxx.xxx
Enter the 32-bit address mask used to indicate the portion (bits) of the IP address that is being used for the subnet address. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode).
74 Gateway IP Addr:
255.255.255.255_
12 digit: xxx.xxx.xxx.xxx
Enter the 4-part address assigned to the Gateway. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode).
75 DNS Serv IP
Addr:
255.255.255.255_
76 Enable Pwr Save
(N)_
12 digit: xxx.xxx.xxx.xxx
[Y], [N]
Enter the 4-part IP address assigned to the DNS (Domain Name
System) server. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode).
To meet the 24 hour UL battery backup requirement, choose "Y" to enable this feature. If this causes connectivity problems with certain routers or switches, then choose "N" and wire the communicator so it is powered from a UL listed UPS.
33