SPECIFICATIONS. Jackson DynaStar Series High Temperature Door Type Dishwasher, DynaStar Series

Add to My manuals
64 Pages

advertisement

SPECIFICATIONS. Jackson DynaStar Series High Temperature Door Type Dishwasher, DynaStar Series | Manualzz

SPECIFICATIONS

DynaStar & DynaStar NB

LEGEND

A - Drain Connection (1 1/2” NPT)

B - Water Inlet (1/2” NPT)

C - Electrical Connection

D - Detergent Connection

E - Rinse-aid Connection

All dimensions from the floor can be increased

2” using the machine’s adjustable feet.

MACHINE DIMENSIONS

8 5/16

[211 mm]

Distance from

Wall to Left

Rack Rail

28 3/4

[731 mm]

E

4 1/4

[108 mm]

MIN

8 5/16

[211 mm]

Distance from

Wall to Rear

Rack Rail

25 1/4

[641 mm]

D

4 1/4

[108 mm]

MIN

07610-004-66-53-D

E

D

34

[863 mm]

A C

B

4 1/2

[113 mm]

3 7/8

[100 mm]

E

3 1/4

[83 mm]

D

A

B

24 1/4

[616 mm]

C

3 1/4

[83 mm]

6 7/8

[174 mm]

2

SPECIFICATIONS

DynaStar VER

LEGEND

A - Drain Connection (1 1/2” NPT)

B - Water Inlet (1/2” NPT)

C - Electrical Connection

D - Detergent Connection

E - Rinse-aid Connection

All dimensions from the floor can be increased

2” using the machine’s adjustable feet.

MACHINE DIMENSIONS

8

[203 mm]

Distance from

Wall to Left

Rack Rail

29 1/4

[743 mm]

E

8 1/4

[210 mm]

Distance from

Wall to Rear

Rack Rail 25 1/4

[641 mm]

B

D

4 1/4

[108 mm]

MIN

3 7/8

[100 mm]

E

E

34 1/2

[876 mm]

07610-004-66-53-D

D

A C

B

4 1/2

[113 mm]

3 1/4

[83 mm]

D

A

B

24 1/4

[616 mm]

C

3 1/4

[83 mm]

6 7/8

[174 mm]

3

False Panel Option

05700-004-67-60

False Panel/Corner

Installation Instructions

SPECIFICATIONS

CORNER INSTALLATION

False Panel Option

05700-004-67-60

8 5/16

[211 mm]

Distance from

Wall to Left

Rack Rail

False Panel/Corner

Installation Instructions

8 5/16

[211 mm]

Distance from

Wall to Rear

Rack Rail

28 3/4

[731 mm]

TABLE DIMENSIONS

20 1/2

[521 mm]

OPENING

4 1/4

[108 mm]

MIN

Control Panel

4 1/4

[108 mm]

MIN

5 3/8

[137 mm]

Notch required for corner insallation only See False

Panel/Corner Installation

Instructions

5

[127 mm]

20 1/2

[521 mm]

OPENING

1 1/4

[32 mm]

STRAIGHT-THROUGH INSTALLATION

28 3/4

[731 mm]

1 ± 1/4

[25 ± 6 mm]

8 5/16

[211 mm]

Distance from

Wall to Rear

Rack Rail

20 1/2

[521 mm]

OPENING

4 1/4

[108 mm]

MIN

07610-004-66-53-D 4

SPECIFICATIONS

PERFORMANCE/CAPABILITIES

Operating Capacity:

DynaStar/DynaStar NB

Racks per Hour without Load Time

Racks per Hour with Load Time

Dishes per Hour without Load Time

Dishes per Hour with Load Time

Glasses per Hour without Load Time

Glasses per Hour with Load Time

DynaStar VER

Racks per Hour without Load Time

Racks per Hour with Load Time

Dishes per Hour without Load Time

Dishes per Hour with Load Time

Glasses per Hour without Load Time

Glasses per Hour with Load Time

Minimum Operating Cycle (seconds):

Cycle 1 Wash Time

Cycle 2 Wash Time

Cycle 3 Wash Time

Rinse Time (Econo)

Rinse Time (Turbo Option)

Dwell Time

Cycle 1 Total Time

Cycle 2 Total Time

Cycle 3 Total Time

VER Condensate Removal

Tank Capacity (gallons/liters):

Wash Tank

Rinse Tank

OPERATING CAPACITIES

WATER REQUIREMENTS

DynaStar

Wash Temperature (Minimum)

Rinse Temperature (Minimum)

Inlet Water Temperature

Water Line Size (NPT)

Drain Line Size (NPT)

150 °F/66 °C

180 °F/83 °C

110 °F/44 °C

1/2”

1 1/2”

62

57

1550

1425

2232

2052

40

38

1000

950

1440

1368

DynaStar NB

Wash Temperature (Minimum)

Rinse Temperature (Minimum)

Inlet Water Temperature

Flow Pressure (PSI)

Water Line Size (NPT)

Drain Line Size (NPT)

150 °F/66 °C

180 °F/83 °C

180 °F/83 °C

10 ± 2

1/2”

1 1/2”

DynaStar VER

Wash Temperature (Minimum)

Rinse Temperature (Minimum)

Inlet Water Temperature

Water Line Size (NPT)

Drain Line Size (NPT)

150 °F/66 °C

180 °F/83 °C

40-90 °F/4.4-32.2 °C

1/2”

1 1/2” 40

90

220

11

14

7

58

108

238

ENERGY SPECIFICATIONS

DynaStar VER

Latent Heat

Sensible Heat

6047 Btu/Hr

5834 Btu/Hr

30

ELECTRICAL LOADS

8.0/30.3

2.0/7.6

Wash Motor HP

Wash Heater kW

Rinse Heater kW

1

5.4

14

NOTICE i

07610-004-66-53-D

Always refer to the machine data plate for specific electrical and water requirements.

The material provided on this page is for reference only and may change without notice

5

SPECIFICATIONS

ELECTRICAL REQUIREMENTS

Local codes may require more stringent protection than what is displayed here Always verify with your electrical service contractor that your circuit protection is adequate and meets all applicable national and local codes Numbers in this manual are for reference and may change without notice i

NOTICE

On three-phase machines, imbalanced wild leg goes to L3

Also see the Motor Rotation section

DynaStar & DynaStar VER

Volts Phase Freq

208 1 60 Hz

Wash

Motor

5.0 A

230

208

1

3

60 Hz

60 Hz

5.0 A

5.0 A

230

460

3

3

60 Hz

60 Hz

5.0 A

1.2 A

Wash

Heater

19.7 A

21.8 A

11.4 A

12.6 A

6.3 A

Rinse

Motor

0.8 A

0.8 A

0.8 A

0.8 A

0.8 A

Rinse

Heater

43.3 A

47.9 A

25.0 A

27.7 A

11.5 A

Total Load

68.8 A

75.5 A

42.2 A

46.0 A

19.8 A

MCA

70.1 A

76.7 A

43.4 A

47.3 A

20.2 A

MOP

75 A

80 A

45 A

50 A

25 A

DynaStar NB

Volts Phase

208

230

208

230

460

3

3

1

1

3

Freq

60 Hz

60 Hz

60 Hz

60 Hz

60 Hz

Wash

Motor

5.0 A

5.0 A

5.0 A

5.0 A

1.8 A

Wash

Heater

19.7 A

21.8 A

11.4 A

12.6 A

6.3 A

Rinse

Heater

N/A

N/A

N/A

N/A

N/A

Total Load

24.7 A

26.8 A

16.4 A

17.6 A

7.5 A

MCA

25.9 A

28.0 A

17.6 A

18.8 A

7.8 A

MOP

30 A

30 A

20 A

20 A

15 A

07610-004-66-53-D 6

advertisement