4-3. Connecting Welding Gun, Voltaje Clamp And Weld cable. Crossfire S 604T / S 604MT

Add to My manuals
24 Pages

advertisement

4-3.  Connecting Welding Gun, Voltaje Clamp And Weld cable. Crossfire S 604T / S 604MT | Manualzz

4-3. CONNECTING WELDING GUN, VOLTAGE CLAMP AND WELD CABLE

1.- REMOTE 14 CABLE

3

4

2.- SHIELDING GAS VALVE INLET

5

6

3.- FUSE F1

4.- SWITCH S1

5.- WIRE FEED INLET

6.- CABLE TO WELDING

POWER SOURCE

2

6

4-4. CONNECTING 14-PIN PLUG

REMOTE-14 Socket

OUTPUT

(CONTACTOR)

G N D

C

REMOTE OUTPUT

CONTROL

E

D

F

A / V

H

NOTE: Remaining sockets are not used

A

B

I

J

G

K

INFORMATION

24 V a.c. Protected by CB2 (10 Amperes).

Contact closure to "A" completes 24 V a.c. contactor control circuit.

120 V a.c. Protected by CB1(10 Amperes).

Contact closure to "I" completes 120 V a.c. contactor control circuit.

Circuit common for 24 and 120 V a.c. circuits.

Chassis common.

Command reference 10 V d.c.

0 to +10 V d.c. input command signal from remote control.

Remote control circuit common.

Current feedback 0-10 V d.c. 1 Volt per100 weld output Amperes.

Voltage feedback 0-10 V d.c. 1 Volt per 10 weld output Volts

3

PM1326

advertisement