INSTALLATION INSTRUCTIONS. KitchenAid KFEG500ESS, KFEG500EWH, KFEG500EBS


Add to my manuals
16 Pages

advertisement

INSTALLATION INSTRUCTIONS. KitchenAid KFEG500ESS, KFEG500EWH, KFEG500EBS | Manualzz

6

INSTALLATION INSTRUCTIONS

Unpack Range

WARNING

Excessive Weight Hazard

Use two or more people to move and install range.

Failure to do so can result in back or other injury.

1.

Remove shipping materials, tape and film from range.

2.

Remove oven racks and parts package from inside oven.

3.

Do not remove the shipping base at this time.

Install Anti-Tip Bracket

WARNING

A

A. Shipping base

4. On Ranges Equipped with a Storage Drawer:

Remove the storage drawer. See the “Storage Drawer” section. Use a ¼" drive ratchet to lower the rear leveling legs one-half turn. Use a wrench or pliers to lower front leveling legs one-half turn.

A

D

C

B

A. ¼" drive ratchet

B. Rear leveling leg

C. Wrench or pliers

D. Front leveling leg

On Ranges Equipped with a Warming Drawer or Premium

Storage Drawer:

On ranges equipped with a warming drawer or premium storage drawer, the rear leveling legs cannot be accessed by removing the warming drawer or premium storage drawer. It will be necessary to adjust the rear leveling legs from outside the range. Use wrench or pliers to lower the front and rear leveling legs one-half turn.

C

A

Tip Over Hazard

A child or adult can tip the range and be killed.

Install anti-tip bracket to floor or wall per installation instructions.

Slide range back so rear range foot is engaged in the slot of the anti-tip bracket.

Re-engage anti-tip bracket if range is moved.

Do not operate range without anti-tip bracket installed and engaged.

Failure to follow these instructions can result in death or serious burns to children and adults.

1.

Remove the anti-tip bracket from where it is taped inside the storage drawer or warming drawer.

2.

Determine which mounting method to use: floor or wall.

If you have a stone or masonry floor, you can use the wall mounting method. If you are installing the range in a mobile home, you must secure the range to the floor.

3.

Determine and mark centerline of the cutout space. The mounting bracket can be installed on either the left-hand side or right-hand side of the cutout. Position mounting bracket against the wall in the cutout so that the V-notch of the bracket is 12 ⁹⁄₁₆ " (31.9 cm) from centerline as shown.

B

Centerline

A

A. 12

⁹⁄₁₆

" (31.9 cm)

B. Bracket V-notch

4.

Drill two

¹⁄₈

" (3 mm) holes that correspond to the bracket holes of the determined mounting method. See the following illustrations.

B

A. Rear leveling leg

B. Wrench or pliers

C. Front leveling leg

Floor Mounting 5.

Using two #12 x 1 ⁵⁄₈ " Phillips-head screws provided, mount anti-tip bracket to the wall or floor.

6.

Move range close enough to opening to allow for final electrical connections. Remove shipping base, cardboard or hardboard from under range.

7.

Move range into its final location, making sure rear leveling leg slides into anti-tip bracket.

Rear position

Wall Mounting

Front position Diagonal (2 options)

8.

Move range forward onto shipping base, cardboard or hardboard to continue installing the range using the following installation instructions.

7

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Frequently Answers and Questions

What type of ground strap is needed?
A UL listed ground strap rated for use with ranges must be used.
What is the purpose of the anti-tip bracket?
To prevent the range from tipping over and causing injury or damage.
What is the minimum clearance required between the range and combustible walls?
Zero clearance.
What should the clearance be between the countertop and the bottom of the range hood?
Follow range hood manufacturer's instructions.
Does the range need to be level after installation?
Yes, the range must be level. Using the cooktop as a reference for leveling is not recommended.
What type of power cord is needed?
A UL listed power supply cord kit marked for use with ranges. The cord should be rated at 250 volts minimum, 40 amps or 50 amps that is marked for use with nominal 1³⁄" (3.5 cm) diameter connection opening and must end in ring terminals or open-end spade terminals with upturned ends.