Technical Data
What Is in This Chapter?
This chapter contains the following topics:
Topic
Ambient Conditions
Standards and Regulations
Mechanical and Electrical Data for the Lexium 62 Power Supply
Mechanical and Electrical Data - Single Drive
Mechanical and Electrical Data - Double Drive
Mechanical and Electrical Data - Lexium 62 DC Link Terminal
Mechanical and Electrical Data - Lexium 62 DC Link Support Module
Dimensions
Page
EIO0000001349 04/2018
199
Technical Data
Ambient Conditions
Overview
Ambient conditions for control cabinet devices:
Procedure
Operation
Parameter
Class 3K3
Degree of protection housing
Transport
Value
Supplemental degree of protection of installed product
Pollution degree
Ambient temperature
Power derating above 40 °C
(104 °F)
Relative humidity
Condensation
Formation of ice
Other water
Class 3M4
Shock
Vibration
Class 2K3
Ambient temperature
Relative humidity
Condensation
Formation of ice
Other water
Class 2M2
Shock
Vibration
IP20 with installed connectors, and, for
LXM62LT, with installed wires.
IP54
2
+5...+55 °C (+41...131 °F)
+40...+55 °C
(+104...+131 °F) (starting
+40 °C (+104 °F): -2% per K by I
NC
and I
SC
)
5...85%
No
No
No
100 m/s
10 m/s
-25...+70 °C (-13...+158 °F)
5...95%
No
No
No
2
300 m/s
10 m/s
2
2
2
Basis
IEC/EN 60721-3-3
IEC/EN 60721-3-2
200
EIO0000001349 04/2018
Technical Data
Procedure
Long-term storage in transport packaging
Parameter
Class 1K3
Ambient temperature
Relative humidity
Condensation
Formation of ice
Other water
Value
-25...+55 °C (-13...+131 °F)
5...95%
No
No
No
Basis
IEC/EN 60721-3-1
Installation Altitude
The installation altitude is defined as height above sea level.
Characteristic
Installation altitude without power reduction
Installation altitude while complying with the following conditions:
55 °C (131 °F) maximum ambient temperature
Reduction of the continuous power by 1% per 100 m (328 ft.) above 1000 m
(3281 ft.)
Installation altitude above sea level when complying with the following conditions:
40 °C (104 °F) maximum ambient temperature
Reduction of the continuous power by 1% per 100 m (328 ft.) above 1000 m
(3281 ft.)
Overvoltages of the supplying grid limited to an overvoltage category II according to IEC 60664-1/IEC 61800-5-1
Value
<1000 m (<3281 ft)
1000...2000 m (3281...6562 ft.)
2000...3000 m (6562...9843 ft.)
Degree of Protection When Using the Safety Function
Ensure that no conductive pollution can deposit in the product (pollution degree 2). Conductive pollution can cause the safety function to be ineffective.
EIO0000001349 04/2018
201
Technical Data
Standards and Regulations
Overview
Standards and regulations
CE
UL
CSA
Low Voltage Directive 2014/35/EU
EN 61800-5:2007
EMC Directive 2014/30/EU
EN 61800-3:2004 + A1:2012
UL 508C Power Conversion Equipment
Industrial Control Equipment
CSA-C22.2 No. 14
Standards and regulations - Lexium 62 DC Link Terminal
CE
UL
Low Voltage Directive 2014/35/EU
EN 60947-1
EN 60947-7-1
EN 60947-7-2
UL 1059 Terminal Blocks
CSA-C22.2 No. 158: Terminal Blocks
Standards and regulations - Lexium 62 DC Link Support Module
CE
UL
Low Voltage Directive 2014/35/EU
EN 61800-5-1
EMC Directive 2014/30/EU
EN 61800-3
UL 61800-5-1
CSA-C22.2 No. 274
Standards and regulations - functional safety
Functional safety Lexium 62 variants A/B (for example, LXM62DU60A):
EN ISO 13849-1, PL d
EN 62061, SIL 2
EN 61508, SIL 2
Lexium 62 variants C/D and E/F (for example, LXM62DU60C):
EN ISO 13849-1, PL e
EN 62061, SIL 3
EN 61508, SIL 3
202
EIO0000001349 04/2018
Technical Data
Mechanical and Electrical Data for the Lexium 62 Power Supply
Technical Data for the Lexium 62 Power Supply
Designation
Product configuration
Power supply
Parameter
Item name
Logic supply
DC circuit
Value
LXM62PD84A11000 LXM62PD20A11000
Rated supply voltage 3
Adjust the parameter
MainsVoltageMode
of the power supply according to the nominal supply voltage.
Rated supply voltage 1
AC
Rated supply current
Supply frequency
Minimum 208 Vac (-10%) / Nominal 230 Vac / Maximum
270 Vac (+10%)
Maximum 40 A
48...63 Hz
Maximum 10 A
Control voltage
Control current maximum current entry maximum current consumption
DC bus voltage
DC bus capacitance
AC
Minimum 380 Vac (-10%) / Nominal 400 Vac / Maximum
480 Vac (+10%)
Minimum 208 Vac (-10%) / Nominal 230 Vac / Maximum
360 Vac (+10%)
24 Vdc (-20%...+25%)
-
50 A (no overload permissible)
1.2 A
270...700 Vdc
1.36 mF
Overvoltage
Rated current (I
Nc
)
Peak current 1 s (I
SC
)
860 Vdc
21 A with 1
AC
infeed
42 A with 3
AC
infeed
42 A with 1
AC
infeed
10 A with 1
10 A with 3
20 A with 1
AC
AC
AC
infeed
infeed
infeed
20 A with 3
AC
infeed
Rated power
Peak power
84 A with 3
AC
infeed
22.1 kW at 3 ~ 400 Vac
26.6 kW at 3 ~ 480 Vac
44.2 kW at 3 ~ 400 Vac
53.2 kW at 3 ~ 480 Vac
830 Vdc U
Bleeder
ON
U
Bleeder
OFF
DC bus unloading time
810 Vdc
Maximum 15 min
5.2 kW at 3 ~ 400 Vac
6.2 kW at 3 ~ 480 Vac
10.4 kW at 3 ~ 400 Vac
12.5 kW at 3 ~ 480 Vac
EIO0000001349 04/2018
203
Technical Data
Designation
Product configuration
Internal braking resistor
Interface
Power loss
Outputs
Parameter
Item name
Resistance
Continuous power
Peak power
Pulse energy
(periodic duty, 120 s)
Sercos
Electronics power supply
Power stage
Braking resistor (internal)
Relay outputs
Value
LXM62PD84A11000 LXM62PD20A11000
15 Ω
400 W
46 kW
4000 Ws (HW Rev. 01)
20000 Ws (HW Rev. 02)
Integrated
15 W
3 W/A (maximum 126 W at 42 A)
400 W
Ready relay, up to 6 A (maximum) for 1 s at 150 Vac and 1.5 A (cont.)
Ready relay, up to 6 A (maximum) for 1 s at 48 Vdc and
1.5 A (cont.)
270 x 89.5 x 310 mm (10.63 x 3.52 x 12.20 in)
6.3 kg / 7.3 kg (13.9 lbs / 16.1 lbs)
C3 (C2 with additional filter measures)
Dimensions
Weight
Radio interference level
Protective class
Overvoltage category
Pollution degree
Housing D x W x H
Weight (with packaging)
–
Class
–
–
1 (IEC 61800-5-1)
III (IEC 61800-5-1:2007)
II starting at an installation altitude of 2000 m
2 (IEC 61800-5-1:2007)
NOTE: Due to the higher pulse energy of the braking resistor in hardware revision RS:02, the precharge of the system may be delayed up to 50 seconds, depending on the load state or the estimated worst case load state of the braking resistor. In particular, this longer delay time can be noticed in situations where the load of the braking resistor is unknown to the system (for example after turning on the 24 V supply of the device or after a forced discharge of the DC Bus).
204
EIO0000001349 04/2018
Technical Data
Mechanical and Electrical Data - Single Drive
Technical Data Single Drive
Designation
Product configuration
Parameter
Item name
Power supply Control voltage
(without holding brake) maximum current consumption
Motor connection
Value
LXM62DU60A
LXM62DU60C
LXM62DU60E
0.6 A
LXM62DD15A
LXM62DD15C
LXM62DD15E
24 Vdc (-20...+25%)
1.1 A
Control voltage
(with holding brake) maximum current consumption
24 Vdc (-10...+6%)
2.0 A
DC bus voltage 250...700 Vdc
2.5 A
110 µF DC bus capacitance
Overvoltage
110 µF
900 Vdc
Rated current (4 kHz)
at 40 °C
(104 °F)
2.0 A eff
5.0 A eff
LXM62DD27A
LXM62DD27C
LXM62DD27E
1.1 A
2.5 A
110 µF
9.0 A eff
LXM62DD45A
LXM62DD45C
LXM62DD45E
1.1 A
3.5 A
220 µF
20.0 A eff
LXM62DC13C
LXM62DC13E
1.1 A
3.5 A
250 µF
50.0 A eff
at 55 °C
(140 °F)
Peak current
(4 kHz) at 55 °C
(140 °F)
1.4 A
6.0 A eff eff
3.5 A eff
15.0 A eff
6.3 A eff
27.0 A
Continuous output power (4 kHz, 400 V mains voltage) eff
13.7 A eff
45.0 A eff
35.0 A eff
130.0 A eff
(HW Rev. 02)
at 40 °C
(104 °F)
0.95 kW 2.4 kW 4.3 kW 9.6 kW 24.7 kW
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Single Drive includes the variants A and C: LXM62DU60A/C, LXM62DD15A/C, LXM62DD27A/C,
LXM62DD45A/C, LXM62DC13C
Lexium 62 Single Drive embedded safety includes the variant E: LXM62DU60E, LXM62DD15E, LXM62DD27E,
LXM62DD45E, LXM62DC13E
EIO0000001349 04/2018
205
Technical Data
Designation
Product configuration
Motor connection
Motor connection
Power loss
Parameter
Item name
Value
LXM62DU60A
LXM62DU60C
LXM62DU60E
Rated current (8 kHz)
at 40 °C
(104 °F)
2.0 A eff
1.4 A eff at 55 °C
(140 °F)
Peak current
(8 kHz) at 55 °C
(140 °F)
6.0 A eff
LXM62DD15A
LXM62DD15C
LXM62DD15E
5.0 A
3.5 A eff eff
15.0 A eff
LXM62DD27A
LXM62DD27C
LXM62DD27E
7.0 A
5.0 A eff eff
27.0 A eff
Continuous output power (8 kHz, 400 V mains voltage)
at 40 °C
(104 °F)
0.95 kW 2.4 kW 3.4 kW
Rated current (16 kHz)
at 40 °C
(104 °F)
1.2 A eff
0.8 A eff
3.5 A
2.6 A eff eff
4.0 A
2.9 A eff eff at 55 °C
(140 °F)
Peak current
(16 kHz) at
55 °C (140 °F)
6.0 A eff
15.0 A eff
27.0 A eff
Maximum length of the motor cable
75 m (246.06 ft)
Continuous output power (16 kHz, 400 V mains voltage)
at 40 °C
(104 °F)
0.6 kW 1.7 kW 2.0 kW
Electronics power supply
8 W 18 W
LXM62DD45A
LXM62DD45C
LXM62DD45E
15.0 A eff
8.9 A eff
45.0 A eff
7.2 kW
8.0 A eff
4.9 A eff
45.0 A eff
3.8 kW
LXM62DC13C
LXM62DC13E
50.0 A eff
30.0 A eff
100.0 A eff
(HW Rev. 02)
24.7 kW
30.0 A eff
20.0 A eff
60.0 A eff
(HW Rev. 02)
16.8 kW
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Single Drive includes the variants A and C: LXM62DU60A/C, LXM62DD15A/C, LXM62DD27A/C,
LXM62DD45A/C, LXM62DC13C
Lexium 62 Single Drive embedded safety includes the variant E: LXM62DU60E, LXM62DD15E, LXM62DD27E,
LXM62DD45E, LXM62DC13E
206
EIO0000001349 04/2018
Technical Data
Designation
Product configuration
Currentdependent power loss
Interface
Encoder
Parameter
Item name
Value
LXM62DU60A
LXM62DU60C
LXM62DU60E
6.6 W/A
LXM62DD15A
LXM62DD15C
LXM62DD15E
LXM62DD27A
LXM62DD27C
LXM62DD27E
LXM62DD45A
LXM62DD45C
LXM62DD45E
Power stage
(4 kHz)
Power stage
(8 kHz)
8.5 W/A
Power stage
(16 kHz)
Sercos
Power supply
Differential analog input
(sine and cosine signal)
14.9 W/A
Integrated
10 Vdc (-5...+5%), maximum 125 mA, short-circuit protection
Input voltage: 0.8...1.1 V
PP
Offset: 2.5 Vdc (-10...+10%)
Terminating resistor: 130 Ω
Cutoff-frequency: 100 MHz
Communication RS-485 interface
LXM62DC13C
LXM62DC13E
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Single Drive includes the variants A and C: LXM62DU60A/C, LXM62DD15A/C, LXM62DD27A/C,
LXM62DD45A/C, LXM62DC13C
Lexium 62 Single Drive embedded safety includes the variant E: LXM62DU60E, LXM62DD15E, LXM62DD27E,
LXM62DD45E, LXM62DC13E
EIO0000001349 04/2018
207
Technical Data
Designation
Product configuration
Digital inputs/outputs
Parameter
Item name
DIO supply
Digital inputs
A_DI3, A_DI4
Digital inputs or
Touchprobe inputs A_DI1,
A_DI2
Digital inputs or digital outputs
A_DI5, A_DI6
Value
LXM62DU60A
LXM62DU60C
LXM62DU60E
LXM62DD15A
LXM62DD15C
LXM62DD15E
Voltage U
DIO
: 24 Vdc (-20...+25%)
LXM62DD27A
LXM62DD27C
LXM62DD27E
LXM62DD45A
LXM62DD45C
LXM62DD45E
Maximum current consumption: 1.2 A
Inputs with switching level type 1 according to EN 61131-2
Low level: -3 ... 5 Vdc
High level: 15...30 Vdc
LXM62DC13C
LXM62DC13E
Filter time constant normal inputs: 1 ms/5 ms (configurable)
Inputs with switching level type 1 according to EN 61131-2
Low level: -3...5 Vdc
High level: 15...30 Vdc
Filter time constant normal inputs: 1 ms/5 ms (configurable)
Filter time constant for Touchprobe inputs: 100 µs
Inputs/outputs (bidirectional) with switching level type 1 according to EN 61131-2
Inputs:
Low level: -3...5 Vdc
High level: 15...30 Vdc
Filter time constant normal inputs: 1 ms/5 ms (configurable)
Outputs:
High level: (U
DIO
- 3 V) < U out
< U
DIO
Maximum output current per output: 500 mA
30 mA – InverterEnable
Variant A
Maximum current consumption
Inputs Number: 1
STO active: -3 V ≤ U
IE
≤ 5 V
Power stage active: 18 V ≤ U
IE
≤ 30 V –
Maximum downtime 500 µs at U
IE
> 20 V and dynamic activation –
Maximum switching frequency of input signal: maximum 1 Hz –
–
–
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Single Drive includes the variants A and C: LXM62DU60A/C, LXM62DD15A/C, LXM62DD27A/C,
LXM62DD45A/C, LXM62DC13C
Lexium 62 Single Drive embedded safety includes the variant E: LXM62DU60E, LXM62DD15E, LXM62DD27E,
LXM62DD45E, LXM62DC13E
208
EIO0000001349 04/2018
Technical Data
Designation
Product configuration
Parameter
Item name
Value
LXM62DU60A
LXM62DU60C
LXM62DU60E
30 mA
LXM62DD15A
LXM62DD15C
LXM62DD15E
LXM62DD27A
LXM62DD27C
LXM62DD27E
LXM62DD45A
LXM62DD45C
LXM62DD45E
LXM62DC13C
LXM62DC13E
InverterEnable
Variant C
Maximum current consumption
Inputs Number: 1
STO active: -3 V ≤ U
IE
≤ 5 V
Power stage active: 18 V ≤ U
IE
≤ 30 V
Maximum downtime 500 µs at U
IE
> 20 V and dynamic activation
Maximum switching frequency of input signal: maximum 1 Hz
15 V
InverterEnable
Variant E
Maximum potential difference between IE- and PE
Maximum current consumption
Inputs
30 mA
Number: 1
STO active: -3 V ≤ U
IE
≤ 5 V
Power stage active: 18 V ≤ U
IE
≤ 30 V
Maximum downtime 500 µs at U
IE
> 20 V and dynamic activation
Maximum switching frequency of input signal: maximum 1 Hz
15 V Maximum potential difference between IE- and PE
Housing D x W x H
Dimensions 270 x 44.5 x 310 mm (10.63 x 1.75 x 12.20 in) 270 x 89.5 x
310 mm
(10.63 x 3.52 x
12.20 in.)
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Single Drive includes the variants A and C: LXM62DU60A/C, LXM62DD15A/C, LXM62DD27A/C,
LXM62DD45A/C, LXM62DC13C
Lexium 62 Single Drive embedded safety includes the variant E: LXM62DU60E, LXM62DD15E, LXM62DD27E,
LXM62DD45E, LXM62DC13E
EIO0000001349 04/2018
209
Technical Data
Designation
Product configuration
Parameter
Item name
Value
LXM62DU60A
LXM62DU60C
LXM62DU60E
3 kg (6.6 lbs)
LXM62DD15A
LXM62DD15C
LXM62DD15E
LXM62DD27A
LXM62DD27C
LXM62DD27E
LXM62DD45A
LXM62DD45C
LXM62DD45E
LXM62DC13C
LXM62DC13E
Weight
-
-
Weight
(without packaging)
Weight
(with packaging)
4 kg (8.8 lbs)
6.8 kg
(14.9 lbs)
7.8 kg
(17.2 lbs)
Ventilation
Radio interference level
Protective class
Overvoltage category
Pollution degree
Motor brake
-
-
Class
Internal fan
C3 (C2 with additional filter measures)
I (IEC 61800-5-1)
III (IEC 61800-5-1:2007)
2 (IEC 61800-5-1:2007)
Output voltage Control voltage minus 0.8 Vdc
Output current 1.3 A (maximum)
Inductance 1.0 H (maximum)
2.2 A (maximum)
1.5 H (maximum)
Energy inductive load
Overload protection
Short-circuit protection
1.2 J (maximum)
Yes
Yes
4.5 J (maximum)
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Single Drive includes the variants A and C: LXM62DU60A/C, LXM62DD15A/C, LXM62DD27A/C,
LXM62DD45A/C, LXM62DC13C
Lexium 62 Single Drive embedded safety includes the variant E: LXM62DU60E, LXM62DD15E, LXM62DD27E,
LXM62DD45E, LXM62DC13E
NOTE: Due to the increased control current of the brake (approximately 2 A), the motor series
SH3205xxxxFxx00 with holding brake can only be operated at the servo converters of type
Lexium 62 single drive (LXM62DD45C or LXM62DD45E) and
LXM62DC13C21000/LXM62DC13E21000.
210
EIO0000001349 04/2018
Technical Data
Mechanical and Electrical Data - Double Drive
Technical Data Double Drive
Designation
Product configuration
Power supply
Parameter
Item name
Control voltage (without holding brakes) maximum current consumption
Control voltage / control current
(with holding brakes) maximum current consumption
DC bus voltage
Value
LXM62DU60B
LXM62DU60D
LXM62DU60F
LXM62DD15B
LXM62DD15D
LXM62DD15F
24 Vdc (-20...+25%)
0.8 A 1.3 A
24 Vdc (-10...+6%)
3.5 A 4.1 A
LXM62DD27B
LXM62DD27D
LXM62DD27F
1.3 A
4.1 A
250...700 Vdc
DC bus capacitance 110 µF
Overvoltage 900 Vdc
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Double Drive includes the variants B and D: LXM62DU60B/D, LXM62DD15B/D, LXM62DD27B/D
Lexium 62 Double Drive embedded safety includes the variant F: LXM62DU60F, LXM62DD15F, LXM62DD27F
EIO0000001349 04/2018
211
Technical Data
Designation
Product configuration
Motor connection
Parameter
Item name
Value
LXM62DU60B
LXM62DU60D
LXM62DU60F
LXM62DD15B
LXM62DD15D
LXM62DD15F
Rated current (4 kHz)
at 40 °C (104 °F) at 55 °C (140 °F)
2.0 A eff
1.4 A eff
5.0 A eff
3.5 A eff
Peak current (4 kHz) at 55 °C
(114 °F)
6.0 A eff
15.0 A eff
Continuous output power per axis (4 kHz, 400 V mains voltage)
at 40 °C (104 °F) 0.95 kW 2.4 kW
Rated current (8 kHz)
at 40 °C (104 °F) at 55 °C (140 °F)
2.0 A eff
1.4 A eff
5.0 A eff
3.5 A eff
Peak current (8 kHz) at 55 °C
(140 °F)
6.0 A eff
15.0 A eff
Continuous output power per axis (8 kHz, 400 V mains voltage)
at 40 °C (104 °F) 0.95 kW 2.4 kW
Rated current (16 kHz)
at 40 °C (104 °F) at 55 °C (140 °F)
1.2 A eff
0.8 A eff
6.0 A eff
3.5 A eff
2.6 A eff
15.0 A eff
Peak current (16 kHz) at 55 °C
(140 °F)
Maximum length of the motor cable
75 m (246.06 ft)
Continuous output power per axis (16 kHz, 400 V mains voltage)
at 40 °C (104 °F) 0.6 kW 1.7 kW
LXM62DD27B
LXM62DD27D
LXM62DD27F
9.0 A eff
6.3 A eff
27.0 A eff
4.3 kW
7.0 A eff
5.0 A eff
27.0 A eff
3.4 kW
4.0 A eff
2.9 A eff
27.0 A eff
2.0 kW
Power loss Electronics power supply
(8 kHz)
Power stage (8 kHz)
11 W
8.5 W/A (per axis)
22 W
Interface Sercos Integrated
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Double Drive includes the variants B and D: LXM62DU60B/D, LXM62DD15B/D, LXM62DD27B/D
Lexium 62 Double Drive embedded safety includes the variant F: LXM62DU60F, LXM62DD15F, LXM62DD27F
212
EIO0000001349 04/2018
Technical Data
Designation
Product configuration
Encoder
Parameter
Item name
Power supply
Differential analog input (sine and cosine signal)
Communication
Digital inputs/ outputs DIO supply
Digital inputs
A_DI3, A_DI4
B_DI1, B_DI4
Digital inputs or Touchprobe inputs
A_DI1, A_DI2
B_DI1, B_DI2
Value
LXM62DU60B
LXM62DU60D
LXM62DU60F
LXM62DD15B
LXM62DD15D
LXM62DD15F
LXM62DD27B
LXM62DD27D
LXM62DD27F
10 Vdc (-5...+5%), maximum 125 mA, short-circuit protection
Input voltage: 0.8...1.1 V
PP
Offset: 2.5 Vdc (-10...+10%)
Terminating resistor: 130 Ω
Cutoff-frequency: 100 MHz
RS-485 interface
Voltage U
DIO
: 24 Vdc (-20...+25%)
Maximum current consumption: 2.2 A
Inputs with switching level type 1 according to EN 61131-2
Low level: -3...5 Vdc
High level: 15...30 Vdc
Filter time constant normal inputs: 1 ms/5 ms
(configurable)
Inputs with switching level type 1 according to EN 61131-2
Low level: -3...5 Vdc
High level: 15...30 Vdc
Filter time constant normal inputs: 1 ms/5 ms
(configurable)
Digital inputs or digital outputs
A_DI5, A_DI6
B_DI5, B_DI6
Filter time constant for Touchprobe inputs: 100 µs
Inputs/outputs (bidirectional) with switching level type 1 according to EN 61131-2
Inputs:
Low level: -3...5 Vdc
High level: 15...30 Vdc
Filter time constant normal inputs: 1 ms/5 ms
(configurable)
Outputs:
High level: (U
DIO
- 3 V) < U out
< U
DIO
Maximum output current per output: 500 mA
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Double Drive includes the variants B and D: LXM62DU60B/D, LXM62DD15B/D, LXM62DD27B/D
Lexium 62 Double Drive embedded safety includes the variant F: LXM62DU60F, LXM62DD15F, LXM62DD27F
EIO0000001349 04/2018
213
Technical Data
Designation
Product configuration
InverterEnable
Variant B
InverterEnable
Variant D
InverterEnable
Variant F
Parameter
Item name
Value
LXM62DU60B
LXM62DU60D
LXM62DU60F
LXM62DD15B
LXM62DD15D
LXM62DD15F
Maximum current consumption 30 mA
Inputs Number: 2
STO active: -3 V ≤ U
IE
≤ 5 V
LXM62DD27B
LXM62DD27D
LXM62DD27F
Power stage active: 18 V ≤ U
IE
≤ 30 V
Maximum downtime 500 µs at U
IE activation
> 20 V and dynamic
Maximum switching frequency of input signal: maximum
1 Hz
Maximum current consumption 30 mA
Inputs Number: 2
STO active: -3 V ≤ U
IE
≤ 5 V
Power stage active: 18 V ≤ U
IE
≤ 30 V
Maximum downtime 500 µs at U
IE activation
> 20 V and dynamic
Maximum potential difference between IE- and PE
Maximum switching frequency of input signal: maximum
1 Hz
15 V
Maximum current consumption 30 mA
Inputs Number: 2
STO active: -3 V ≤ U
IE
≤ 5 V
Maximum potential difference between IE- and PE
Housing D x W x H
Power stage active: 18 V ≤ U
IE
≤ 30 V
Maximum downtime 500 µs at U
IE activation
> 20 V and dynamic
Maximum switching frequency of input signal: maximum
1 Hz
15 V
270 x 44.5 x 310 mm (10.63 x 1.75 x 12.20 in.) Dimensions
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Double Drive includes the variants B and D: LXM62DU60B/D, LXM62DD15B/D, LXM62DD27B/D
Lexium 62 Double Drive embedded safety includes the variant F: LXM62DU60F, LXM62DD15F, LXM62DD27F
214
EIO0000001349 04/2018
Technical Data
Designation
Product configuration
Parameter
Item name
Weight
Ventilation
Radio interference level -
-
Weight
(without packaging)
Weight
(with packaging)
Protective class
Overvoltage category
Pollution degree
Motor brake
-
-
Class
Output voltage
Output current
Inductance
Energy inductive load
Value
LXM62DU60B
LXM62DU60D
LXM62DU60F
3 kg (6.6 lbs)
4 kg (8.8 lbs)
LXM62DD15B
LXM62DD15D
LXM62DD15F
Internal fan
C3 (C2 with additional filter measures)
I (IEC 61800-5-1)
III (IEC 61800-5-1:2007)
2 (IEC 61800-5-1:2007)
Control voltage minus 0.8 Vdc
1.3 A (maximum)
1.0 H (maximum)
1.2 J (maximum)
LXM62DD27B
LXM62DD27D
LXM62DD27F
Overload protection
Short-circuit protection
Yes
Yes
NOTE:
Lexium 62 Cabinet Drive includes Lexium 62 Single Drive and Lexium 62 Double Drive.
Lexium 62 Double Drive includes the variants B and D: LXM62DU60B/D, LXM62DD15B/D, LXM62DD27B/D
Lexium 62 Double Drive embedded safety includes the variant F: LXM62DU60F, LXM62DD15F, LXM62DD27F
EIO0000001349 04/2018
215
Technical Data
Mechanical and Electrical Data - Lexium 62 DC Link Terminal
Technical Data Lexium 62 DC Link Terminal
Designation
Product configuration
Electrical specification
Pollution degree
Over voltage category
Lifetime of end product –
–
–
Parameter
Item name
Rated Voltage
Value
Lexium 62 DC Link Terminal
1000 Vdc on the Lexium 62 DC Link Terminal connectors for the upper three Bus Bar Module ports.
NOTE: The ports of the Bus Bar Module are numbered from top to bottom.
Rated continuous current
24 Vdc on the Lexium 62 DC Link Terminal connectors for the bottom two Bus Bar Module ports.
120 A with temperature rise of less than 60 K.
High voltage test level 2120 Vdc or 1500 Vac between ports 2 and 1 and between ports 3 and 1 of Bus Bar Modules.
System voltage
NOTE: The ports of the Bus Bar Module are numbered from top to bottom.
300 V
2 (IEC 60664-1)
III
≥60,000 hours
216
EIO0000001349 04/2018
Technical Data
Mechanical and Electrical Data - Lexium 62 DC Link Support Module
Technical Data Lexium 62 DC Link Support Module
Designation
Product configuration
Parameter
Item name
Power supply
Cooling
Degree of protection
Isolation class
Protective class
Overvoltage category
Radio interference level
Dimensions
Weight
Lifetime of end product
Control voltage
DC bus voltage
(nominal)
DC bus capacity
Discharge time
-
Overvoltage
-
Pollution degree
Class
Class
Class
Housing D x W x H
Weight (with packaging)
–
Value
Lexium 62 DC Link Support Module
(LXM62LS18A01000)
30 Vdc (maximum)
700 Vdc (maximum)
1.76 mF
5 min (maximum)
900 Vdc
Natural convection
IP20
2 (IEC 60664-1)
1 (IEC/EN 61800-5-1)
III (IEC/EN 61800-5-1)
C3 (IEC/EN 61800-3)
270 x 44 x 310 mm
(10.63 x 1.73 x 12.20 in.)
3.1 kg (3.8 kg) / 6.83 lbs (8.38 lbs)
≥60,000 hours
EIO0000001349 04/2018
217
Technical Data
Dimensions
Dimensions - Power Supply
Dimensions of the Lexium 62 Power Supply:
218
EIO0000001349 04/2018
Dimensions - Lexium 62 Cabinet Drive
Dimensions of the Lexium 62 Cabinet Drive (excluding
LXM62DC13C21000/LXM62DC13E21000):
Technical Data
EIO0000001349 04/2018
219
Technical Data
Dimensions of the Lexium 62 Cabinet Drive (only LXM62DC13C21000/LXM62DC13E21000):
220
EIO0000001349 04/2018
Dimensions - Lexium 62 DC Link Support Module
Dimensions of the Lexium 62 DC Link Support Module:
Technical Data
EIO0000001349 04/2018
221
Technical Data
Dimensions - Lexium 62 DC Link Terminal
Dimensions of the Lexium 62 DC Link Terminal:
222
EIO0000001349 04/2018
Изтегляне