Instruction Manual pH 510/ Ion 510

1 INTRODUCTION

1.1 Introducing the 510 Bench Series

The pH 510 and Ion 510 bench meters are microprocessor-based which incorporates new ASIC (Application

Specific Integrated Circuit). It is designed with convenience in mind, and offers many advanced user-friendly features. The meters are capable of storing and recalling up to 50 data sets in its non-volatile memory. In addition, as a space saver, an optional swivel electrode holder can be attached at the either side of bench meter for resting the electrodes and probes during operation.

The pH 510 meter is capable of measuring pH/ORP with Temperature; while the Ion 510 meter measures Ion

Concentration/pH/ORP with temperature. It is equipped with a large customized LCD (Liquid Crystal Display) with simultaneous display of the measured values for easy reading. It is most ideal for routine pH/Ion

Concentration measurement in indoor applications.

1.2 Custom LCD

The 510 meter is characterized by a large custom dual LCD. The display has mode annunciators for pH, mV, ppm and temperature readings. The secondary (lower) display shows the temperature reading simultaneously with the primary (upper) display that shows the measured values of pH, ppm or mV. Special annunciators such as units of measure, error message, graphical icons and modes of operation are arranged around both primary and secondary display to give you a comprehensive yet uncluttered display.

SETUP – The meter is in SETUP mode.

MEAS The instrument is in the measurement mode.

CAL - The instrument is in the calibration mode .

- Data is stored into memory

- The measured value has stabilized.

- The displayed value has been frozen.

ERR - An error in operation has occured .

- Prompts user to select buffer during calibration, or indicates buffer error when flashing together with the ERR annunciator.

SETUP

READY

HOLD

MEAS

ERR electrode error when it appears with ERR.

CAL MEM

R.mV

pH ppm

C F pH

ATC

Shows the respective mode of operation.

ATC (Automatic

Temperature

Compensation) activated. If ATC is not displayed, temperature probe is not connected.

In this case the Manual

Temperature

Compensation is activated.

pH – Indicates buffer values of respective

USA or NIST buffer option set.

1