Instruction Manual pH 510/ Ion 510
1 INTRODUCTION
1.1 Introducing the 510 Bench Series
The pH 510 and Ion 510 bench meters are microprocessor-based which incorporates new ASIC (Application
Specific Integrated Circuit). It is designed with convenience in mind, and offers many advanced user-friendly features. The meters are capable of storing and recalling up to 50 data sets in its non-volatile memory. In addition, as a space saver, an optional swivel electrode holder can be attached at the either side of bench meter for resting the electrodes and probes during operation.
The pH 510 meter is capable of measuring pH/ORP with Temperature; while the Ion 510 meter measures Ion
Concentration/pH/ORP with temperature. It is equipped with a large customized LCD (Liquid Crystal Display) with simultaneous display of the measured values for easy reading. It is most ideal for routine pH/Ion
Concentration measurement in indoor applications.
1.2 Custom LCD
The 510 meter is characterized by a large custom dual LCD. The display has mode annunciators for pH, mV, ppm and temperature readings. The secondary (lower) display shows the temperature reading simultaneously with the primary (upper) display that shows the measured values of pH, ppm or mV. Special annunciators such as units of measure, error message, graphical icons and modes of operation are arranged around both primary and secondary display to give you a comprehensive yet uncluttered display.
SETUP – The meter is in SETUP mode.
MEAS The instrument is in the measurement mode.
CAL - The instrument is in the calibration mode .
- Data is stored into memory
- The measured value has stabilized.
- The displayed value has been frozen.
ERR - An error in operation has occured .
- Prompts user to select buffer during calibration, or indicates buffer error when flashing together with the ERR annunciator.
SETUP
READY
HOLD
MEAS
ERR electrode error when it appears with ERR.
CAL MEM
R.mV
pH ppm
C F pH
ATC
Shows the respective mode of operation.
ATC (Automatic
Temperature
Compensation) activated. If ATC is not displayed, temperature probe is not connected.
In this case the Manual
Temperature
Compensation is activated.
pH – Indicates buffer values of respective
USA or NIST buffer option set.
1
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 5 INTRODUCTION
- 5 Introducing the 510 Bench Series
- 5 Custom LCD
- 6 Keypad
- 7 Rear Instrument Panel
- 8 STARTING UP
- 8 Connecting the Sensor Electrode
- 8 Connecting the Temperature Probe
- 8 Connecting the A/C Adapter
- 8 Connecting the Chart Recorder
- 9 Connecting the Electrode Holder (Optional)
- 10 Steps Prior to Calibration
- 10 CALIBRATION
- 10 pH Calibration
- 13 Ion Concentration Calibration (For Ion 510 only)
- 15 mV Calibration
- 16 Temperature Calibration
- 17 MEASUREMENT
- 17 Automatic Temperature Compensation (ATC)
- 17 Manual Temperature Compensation (MTC)
- 18 Taking Measurements
- 19 HOLD Function
- 19 Storing and Recalling Data from Memory
- 21 SETUP FUNCTIONS
- 21 P1.0 Clear Memory
- 22 P2.0 Viewing Electrode Diagnosis
- 23 P3.0 Selecting pH Buffer Standard
- 23 P4.0 Meter Reset
- 24 pH Electrode Maintenance
- 24 Storage
- 24 After Use
- 25 Electrode Cleaning
- 26 pH Electrode Rejuvenation
- 27 TROUBLESHOOTING GUIDE
- 27 Error Messages
- 28 Troubleshooting
- 29 ADDITIONAL INFORMATION
- 29 pH and Temperature
- 29 Use of Standard pH Buffers
- 29 Standard pH Buffers
- 30 List of Accessories
- 32 Specifications
- 33 WARRANTY
- 33 RETURN OF ITEMS