iNsTAllATioN

Installation in premises with fire hazards is forbidden. Installation in residential premises (except for sealed operation appliances) is also forbidden:

Š in which there are liquid fuel-operated appliances with continuous or intermittent operation, which draw the combustion air in the room in which they are installed, or

Š in which there are type B gas appliances intended for room heating, with or without production of domestic hot water and in adjacent and adjoining premises, or

Š in which, in any case, the depression measured during installation between the internal and external environment is greater than 4 Pa

installations in bathrooms, bedrooms and studio flats

Installation in bathrooms, bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken from the outside.

installation premises requirements

The support surfaces and/or points must have a suitable load-bearing capacity to support the weight of the appliance, of the accessories and coatings.

The adjacent, side and rear walls and the supporting surface must be made of non-combustible material. Installation near combustible materials or those sensitive to heat is permitted as long as there is a suitable safety distance, which for pellet stoves is equal to:

ReFeReNces

A

B

C

iNFlAMMAble objecTs

200 mm

1500 mm

200 mm

NoN-iNFlAMMAble objecTs

100 mm

750 mm

100 mm

Flue

B

C

A

Air inlet figure 1

Inspection figure 2

S

S= floor protection

In any case the temperature of the adjacent combustible materials must not reach a temperature equal to or greater than the room temperature increased by 65°C.

The minimum volume of the premises in which to install the appliance must be greater than 15 m³.

iNseRTs iNsTAllATioN

In the event of installation of inserts, access to the internal parts of the device is to be prevented and, during extraction, it should not be possible to access to live parts.