- No category
![](http://s1.manualzz.com/store/data/002235318_1-f87474692ab24182563786b999729939-128x128.png)
advertisement
![PELLET STOVES USER MANUAL | Manualzz PELLET STOVES USER MANUAL | Manualzz](http://s1.manualzz.com/store/data/002235318_1-f87474692ab24182563786b999729939-360x466.png)
iNsTAllATioN
Installation in premises with fire hazards is forbidden. Installation in residential premises (except for sealed operation appliances) is also forbidden:
in which there are liquid fuel-operated appliances with continuous or intermittent operation, which draw the combustion air in the room in which they are installed, or
in which there are type B gas appliances intended for room heating, with or without production of domestic hot water and in adjacent and adjoining premises, or
in which, in any case, the depression measured during installation between the internal and external environment is greater than 4 Pa
installations in bathrooms, bedrooms and studio flats
Installation in bathrooms, bedrooms and studio flats is only allowed for sealed or closed hearth appliances with ducted combustion air taken from the outside.
installation premises requirements
The support surfaces and/or points must have a suitable load-bearing capacity to support the weight of the appliance, of the accessories and coatings.
The adjacent, side and rear walls and the supporting surface must be made of non-combustible material. Installation near combustible materials or those sensitive to heat is permitted as long as there is a suitable safety distance, which for pellet stoves is equal to:
ReFeReNces
A
B
C
iNFlAMMAble objecTs
200 mm
1500 mm
200 mm
NoN-iNFlAMMAble objecTs
100 mm
750 mm
100 mm
Flue
B
C
A
Air inlet figure 1
Inspection figure 2
S
S= floor protection
In any case the temperature of the adjacent combustible materials must not reach a temperature equal to or greater than the room temperature increased by 65°C.
The minimum volume of the premises in which to install the appliance must be greater than 15 m³.
iNseRTs iNsTAllATioN
In the event of installation of inserts, access to the internal parts of the device is to be prevented and, during extraction, it should not be possible to access to live parts.
Any wiring, such as a power supply cable or room sensors must be positioned so as not to be damaged during movement of the insert, or come into contact with hot parts.
ENGLISH 7
advertisement
Related manuals
advertisement
Table of contents
- 4 ENGLISH
- 4 Warnings
- 4 Safety
- 4 Routine Maintenance
- 5 devices
- 5 REFERENCE STANDARDS
- 6 General
- 7 INSTALLATION
- 7 Inserts Installation
- 8 Fumes exhaust system
- 8 General requirements
- 9 Smoke duct
- 11 Chimney
- 11 Chimney caps
- 12 FUMES EXHAUST SYSTEM PRODUCT REQUIREMENTS
- 12 Combustion products outlet quota
- 13 TECHNICAL INSTALLATION DOCUMENTATION
- 14 SOUVENIR and ILENIA spacers
- 14 HOT AIR DUCTING
- 14 Elisir
- 15 SOUVENIR - ILENIA
- 16 GRAZIOSA PLUS & IRMA PLUS
- 16 EMMA PLUS & TOSCA PLUS
- 17 additional thermostat for ducting motor control
- 17 REARMS
- 18 INSTALLING COMFORT MAXI/ COMFORT PLUS
- 18 Assembly with sliding base
- 19 Comfort Plus
- 19 Pedestal assembly (optional):
- 20 Front pellet feeding kit (optional)
- 20 Air circulation pipes
- 22 Insert extraction
- 23 Mounting the frames
- 23 Pellets and feeding
- 24 Control panel
- 24 Display icons key
- 25 General menu
- 25 Basic instructions
- 26 Remote control
- 26 Type and replacement of batteries
- 26 COMMISSIONING settings
- 26 Mains frequency 50/ 60Hz
- 27 Adjusting time, day, month and year
- 27 Adjusting language
- 28 Operation and logic
- 29 additional thermostat (optional)
- 29 user menu
- 29 Display
- 29 Pellet feed adjustment
- 30 V1- Air
- 30 STAND BY
- 31 keys locked
- 32 V2 - Air
- 32 reset
- 32 Enable chrono
- 32 Chrono
- 33 Programming example
- 1 Cleaning And Maintenance
- 1 Cleaning and Maintenance by the user
- 1 Routine maintenance
- 42 Displays
- 43 ALARMS