In the TRAP TYPE box select the message type desired, trap or inform. If inform is selected, the timeout the agent waits (if no answer from the manager) before re-send the inform message can be set in the INFORMS TIMEOUT box, the number of inform retransmission can be set in INFORMS
RETRIES box.
The messages trap/inform have to be enable and can be enable singly. The enable is provided to the
OIDs (fmSTEventEnable folder):
EVENT OID
fmSTTransmitterOpModeEventEnable .1.3.6.1.4.1.19831.1.1.3.1.2.1.1
DESCRIPTION
8.3.3 COMMANDS AND STATE
Commands and State available through SNMP are summed in the following table:
EVENT OID TYPE DESCIPTION
fmSTTransmitterOpMode .1.3.6.1.4.1.19831.1.1.3.1.1.1 fmSTRFPresent fmSTFault
.1.3.6.1.4.1.19831.1.1.3.1.1.2
.1.3.6.1.4.1.19831.1.1.3.1.1.3
Read and Write
Read only
Read only
1=ON, 2=OFF
1=Present, 2=Not Present
1=Fault, 2=No Fault fwSTWarning fmSTLocalMode
.1.3.6.1.4.1.19831.1.1.3.1.1.4
.1.3.6.1.4.1.19831.1.1.3.1.1.5
Read only
Read only
1=Warning, 2=No Warning
1=Local, 2=Remote
The commands are accepted by the unit only in remote mode and if the community strings are correctly set for both read and write operations.
The community read/write strings have to be set both to the agent and manager units. In the webpage can be set in the Administration menu.
MOZART SERIES –FM Exciters/Transmitters - U
SER
’
S
M
ANUAL
100 /113
advertisement
Related manuals
advertisement
Table of contents
- 8 GENERAL INFORMATION
- 8 NOTICES
- 9 ELECTROCUTION
- 10 (WEEE)
- 10 LABELS
- 12 FM EXCITER GENERAL DESCRIPTION
- 13 CHARACTERISTICS
- 13 HIGHLIGHTS
- 14 CONTROL
- 16 HIGHLIGHTS
- 16 PROTECTIONS
- 23 TECHNICAL SPECIFICATIONS
- 26 INSTALLATION AND ACTIVATION
- 26 CHECK
- 27 CONNECTIONS
- 28 MENU DESCRIPTION
- 28 VISUALIZATION
- 28 START PAGE
- 28 Main menu
- 30 Output Modulation
- 30 Left and Right channels level
- 30 AES-EBU Left and Right channels level
- 31 Auxiliary channels level
- 31 Voltages and current
- 32 Heatsink temperature
- 32 Device information
- 34 Frequency Set menu
- 34 Power Set menu
- 35 Operative Mode menu
- 38 Audio Selection menu
- 41 Sensitivity menu
- 42 Presetting menu
- 49 Alarms menu
- 56 Memory menu
- 60 History menu
- 62 Generals menu
- 66 FRONT PANEL
- 68 Status leds
- 69 Audio leds
- 70 Control leds
- 71 Command leds
- 72 REMOTE I/O (OPTIONAL)
- 73 WEB SERVER (OPTIONAL)
- 74 PAGES
- 74 Main page
- 75 Login page
- 76 Settings page
- 77 Presettings page
- 78 Memories scheduling
- 79 Email notifications
- 83 Log page
- 84 Administration page
- 86 Modulator Upgrade page
- 87 Webserver Upgrade page
- 88 PROCEDURES
- 88 Upgrading the modulator firmware
- 92 Upgrading the webserver board firmware
- 96 PROTOCOL
- 96 Management Information Base MIB
- 99 Message trap and inform
- 100 Commands and State
- 101 TOP VIEWS
- 111 APPENDIX 1: EXTERNAL REFERENCE
- 112 APPENDIX 2: STEREO OPTION INSTALLATION