![](http://s1.manualzz.com/store/data/006944799_1-eb77d0ac6e9df51bf2a4b76a20bbd269-128x128.png)
advertisement
![Portable power analyzer | Manualzz Portable power analyzer | Manualzz](http://s1.manualzz.com/store/data/006944799_1-eb77d0ac6e9df51bf2a4b76a20bbd269-360x466.png)
Portable power analyzer
M
.8
CIR-e
3
Portable single and three-phase power analyzer
Parameter
Voltage
Current
Frequency
Active Power
Reactive Power (L & C)
Apparent Power
Power Factor
Active Energy
Reactive Energy ( L & C )
Aparent energy
Harmonic decomposition
U, I (50)
THD (%) U, I
MD (Max demand) - act.Pow
MD (Max demand) -App.Pow
Fundamental U, I
Flicker WA
Flicker Pst
Symbol
(unit)
V
A
Hz
W varL, varC
V · A
FP
W ·h var ·hL,var ·hC
V ·A ·h
L1 L2 L3 III
Yes Yes Yes
Yes Yes Yes
Yes
Max./
Min.
Yes
Yes
Yes
Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes
Yes Yes Yes Yes Yes
Yes
Yes
Yes
% THD
W (MD)
V ·A (MD)
WA
Pst
Yes Yes Yes
Yes Yes Yes
Yes Yes
Yes Yes
Yes Yes Yes
Yes Yes Yes
Yes Yes Yes Yes Yes
Connections
Umbalanced three-phase system
References
Analyzer
CIR-e 3 -
Clamps Type
CIR-e 3
Code
M85020
CIR-e 3 E-FLEX 54
Kit 3 clamps CP-100 CIR-e
3
CIR-e 3 E-FLEX 54 M85000
Accesories
Kit 3 clamps E-FLEX 54 200/2.00/20.000 A
Kit 3 clamps CP-5 CIR-e
3
M86010
M86011
M86012
kit 6 Voltage cables
Carring case
M86020
M89931
Balanced single-phase system
Dimensions
L 1
L 2
L 3
N
Alimentación auxiliar
Power supply
L 1
N
Alimentación auxiliar
Power supply
Magnetic fixing
M8-19
M
.8
Portable power analyzer
CIR-e
Q
Description
}
Voltage measurement
}
Voltage quality measurement parameters
}
Configurable by pC
}
Store electric parameters and voltage events in SD card (up to 2 GB)
}
Posibility of external power supply
100…400 Vac and 70…315 Vdc
}
Reduced size and weight (300g) very robust and easy to use
}
The measurement unit includes the right of use of the associated software that is required to handle the data of the CIR-e
Q
Web application (STD file)
}
Magnet fixing
Application
} has been designed to incorporate the latest technologies and it offers the most advanced performance features in the market for the measurement and recording of the electrical parameters of electrical networks
features
Power supply circuit
Voltage
Frequency
Consumption 100 / 400 Vac
Consumption 70 / 315 Vdc
Measurement circuit
Voltage ( ph-N )
Voltage
ph-ph
Frequency
Accuracy
Others features
Working temperature
100...400 V c.a., 70...315 V c.c.
50...60 Hz
5,2 / 22 V ·A
3 W
10...400 V ac. (ph-N)
17...520 V ac. (ph-ph)
45...65 Hz
0,5 % FS.
Altitude
Humidity
Storage temperature
10...50 ºC
2 000 m
95 % HR without condensation
-10...65 ºC
IP 53
Protection
Weight (only CIRe3) weight (with packaging)
0,677 kg
0,713 kg
Standard
ELECTRICAL SAFETY REGULATIONS: IEC 60664-1, IEC 61010-1, UL 94, VDE 110
ELECTROMAGNETIC EMISSIONS: IEC 61000-3-2, IEC 61000-3-3, IEC 61000-6-4, EN 55011, EN 55022
ELECTROMAGNETIC IMMUNITY: IEC 61000-6-2, IEC 61000-4-2, IEC 61000-4-3, IEC
61000-4-4, IEC 61000-4-5, IEC 61000-4-8, IEC 61000-6-1, IEC 61000-4-11, ENV 50141
M8-20
advertisement
Related manuals
advertisement
Table of contents
- 5 Portable single and three-phase power analyzer
- 14 Portable single and three-phase power analyzer
- 19 Umbalanced three-phase system
- 21 Umbalanced three-phase system
- 22 High voltage clamps
- 23 Clamps with memory
- 24 Earth resistance meter
- 25 Insulation meter
- 26 Current sensing clamp - multimeter
- 27 Basic operating instructions
- 28 Luxmeter
- 28 Alternating voltage detector