–411: IEC 61000-4-11 Voltage Dips and Interruptions
9.8.1 General
The IEC 61000-4-11 option is capable of performing IEC 61000-4 section 11 voltage dips, short interruptions and voltage variations immunity tests. On MX15 Series AC sources, the user can only perform single phase tests.
Operation of the
9.8.2 Front Panel Entry
No front panel operation is available for the IEC 61000-4-13 option on the MX15 Series AC power source. Instead, use of the provided MXGUI Windows software is required to use this option.
The -411 option can be programmed using SCPI bus commands. For details, refer to the MX
Series programming manual P/N 7003-961.
9.8.3 Standard Revisions and EUT Classes
The
–411 option supports both the first (1994-06) and the second edition (2004-03) of the IEC
61000-4-11 test standard.
Generic tests files are distributed with the MXGui program for both editions of the test standard.
Files applicable to Edition 2.0 have ED20 in their file name. Do not mix these files, as the data setup will not be correct if you do. To load a test file, select the Mode (Dips or Vars) and test standard revision first, then use the File, Open menu to load the test parameters. Test parameters can be a function of the EUT class. The different files provided with the program cover the various EUT classes. The relevant EUT class 1, 2, 3 or X is listed in the file names.
Refer to the MXGUI on line help for information on using the IEC411 test screen..
MX15 171
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 10 Introduction
- 10 General Description
- 10 Manual organization and format
- 11 Specifications
- 11 Electrical
- 19 Mechanical
- 20 Environmental
- 20 Regulatory
- 20 Front Panel Controls
- 21 Special Features and Options
- 29 Supplemental Specifications
- 34 Unpacking and Installation
- 34 Unpacking
- 34 Power Requirements
- 35 Mechanical Installation
- 35 AC Input Connections and Wiring
- 39 AC On/Off Circuit Breaker on MX Series front panel
- 41 Output Connections
- 49 Connectors - Rear Panel
- 57 Multiple Cabinet Power Up/Down Procedures
- 58 Clock and Lock Configurations
- 61 Basic Initial Functional Test
- 63 Remote Inhibit / Remote Shutdown
- 64 Junction Box Accessory
- 65 Output Filter Box Accessory
- 66 Front Panel Operation
- 66 Tour of the Front Panel
- 71 Menu Structure
- 96 Output Programming
- 98 Waveform Management [1Pi Controller only]
- 102 Standard Measurements
- 104 Advanced Measurements [1Pi Controller only]
- 105 Transient Programming
- 111 Principle of Operation
- 111 General
- 111 Overall Description
- 113 Controller Assembly
- 116 System Interface Board
- 116 Current / Voltage Sensor Board
- 116 Low Voltage Power Supply
- 117 Power Module
- 122 Calibration
- 122 Recommended Calibration Equipment
- 123 Front Panel Calibration Screens
- 124 Routine Measurement Calibration
- 126 Routine Output Calibration
- 127 Non-Routine Calibration
- 130 Service
- 130 Cleaning
- 130 General
- 130 Basic operation
- 132 Advanced Troubleshooting
- 134 Factory Assistance
- 135 Fuses
- 135 Firmware Updates
- 138 Top Assembly Replaceable Parts
- 141 Options
- 141 Introduction
- 141 Option -HV: Additional AC Voltage Range
- 142 –160: RTCA/DO-160 Tests
- 156 –704: MilStd704 Tests
- 169 –ABD: Airbus ABD0100.1.8 Test
- 169 –787: Boeing B787-0147 Test
- 170 –WHM: Watt Hour Measurement
- 171 –411: IEC 61000-4-11 Voltage Dips and Interruptions
- 172 –413: IEC 61000-4-13 Interharmonics Test
- 174 –SNK: Current Sink
- 177 . Error Messages
- 182 Index