- No category
advertisement
Configuring BabyWare Access
The PCS250G GPRS Communicator Module provides remote access for upload and download with BabyWare via a GPRS connection. The following site specific sections must be configured for BabyWare access.
Note: In the case where a reportable event occurs while a BabyWare session is active via GPRS, the communication is terminated to allow event reporting.
MG/SP/E EVO
[920]
[927]
[2966]
[3013]
Feature
Software port
Password
Details
Default: 10000
Default: admin
Programming and Registering GPRS Reporting
Options
The following sections describe the options that must be programmed in the panel for GPRS reporting. If you are using an
UC300 Universal Converter, please program GMS reporting options via BabyWare.
MG/
SP/E
[918]
[919]
EVO
[2976] to
[2983]
[806] [2975]
Feature Details
Account / partition registration
MG/SP/E: sections represent account / partition 1 & 2
EVO: sections represent account / partition 1 to 8
[7] Off + [8] Off = Landline only
[7] Off + [8] On = GPRS primary / landline backup (default)
[7] On + [8] Off = Landline only
[7] On + [8] On = Landline & GPRS in parallel
Page 20
Configuring the PCS250G
Receiver Settings MG/SP/E
Receiver #:
IP address*
IP port**
IP address WAN2
IP port WAN2
Receiver password
†
Security profile
Module registration press [
ARM
] to register
1
[929]
[930]
[931]
[932]
[933]
[934]
[935]
2
[936]
[937]
[938]
[939]
[940]
[941]
[942]
Backup
[943]
[944]
[945]
[946]
[947]
[948]
[949]
Receiver Settings EVO
Receiver #:
IP address*
IP port**
IP address WAN2
IP port WAN2
Receiver password
†
Security profile
1
[2984]
2
[2986]
3
[2988]
4
[2990]
Module registration press [
ARM
] to register
[2985] [2987] [2989] [2991]
* For 1 or 2 digit numbers, add “0s” before the digit: e.g.,
138.002.043.006
** Default 10000
†
Enter [
MEM
] for blank space
Note: When entering into Receiver Settings sections, the LCD screen of the control panel’s keypad will display “Data” for the receiver password and security profiles sections.
Configuring the PCS250G Page 21
advertisement
Related manuals
advertisement
Table of contents
- 4 Features
- 5 In the Box
- 5 Required/Optional Items
- 5 Compatibility
- 6 System Components
- 7 LED Feedback
- 7 Communication Loss
- 8 SIM Card Functionality
- 8 Tamper Switch Functionality
- 9 Specifications
- 10 SIM Card Connection
- 11 GPRS Connections
- 12 Communication Bridge
- 13 UC300 Connection
- 14 Optional Power Supply Connections
- 14 Using an External Power Input
- 15 Antenna Extension Installation (Optional)
- 15 Module Installation
- 17 Frequency Band
- 17 Bandwidth Saver Mode
- 17 SMS Forwarding
- 17 Communicating Using Text Messages
- 18 Programming Phone Numbers At The Panel
- 18 Forwarding SMS Text Messages
- 18 Receiving Text Messages
- 18 Configuring GSM Network Provider Information
- 20 Configuring BabyWare Access
- 20 Programming and Registering GPRS Reporting Options
- 22 SMS Backup Reporting
- 22 Configuring the PCS250G for SMS Backup Reporting
- 24 Troubles
- 24 Text Message Notification
- 25 SMS Language
- 26 Arm/Disarm System via Text Message
- 27 List of SMS Commands
- 29 Public Network
- 30 Private Network
- 32 End User SMS Programming
- 32 End User SMS Programming with Digiplex EVO
- 32 End User SMS Programming with MG/SP / E-Series
- 33 View GPRS IP Information
- 34 Viewing GPRS IP Information with Digiplex EVO
- 34 Viewing GPRS IP Information with MG/SP / E-Series
- 35 Alarm Messages
- 36 Arming/Disarming Messages
- 37 Trouble Event Messages
- 38 Trouble Restore Messages
- 38 UC300 Messages
- 39 UC300 Alarm Messages
- 40 UC300 Arming/Disarming Messages
- 40 UC300 Trouble Messages
- 43 UC300 Trouble Restore Messages