MI 2792A PowerQ4 Plus

Operating the instrument

Show voltage and current waveform (single mode);

Show voltage and current waveform (dual mode).

Select between phase, neutral, all-phases and line view:

 Show waveforms for phase L1;

 Show waveforms for phase L2;

 Show waveforms for phase L3;

 Show waveforms for neutral channel;

 Summary of all phases waveforms;

 Show phase-to-phase voltages.

Switch to METER view.

Switch to SCOPE view.

Select which waveform to zoom (only in U/I or U+I).

Set vertical zoom.

Set horizontal zoom.

Return to the “WAVEFORM RECORDER” setup screen.

3.10.3 Captured waveform

Captured waveform can be viewed from the Memory list menu. Following views are available for the waveform record:

 U,I,f meter table screen,

 U,I,f screen,

 U,I,f RMS trend screen.

Figure 3.35: Captured waveform meter screen

Table 3.44: Instrument screen symbols and abbreviations – METER

RMS

Show currently displayed channel.

Show record number in MEMORY LIST.

Current instrument time.

True effective value U

Rms(10)

and I

Rms(10).

48

MI 2792A PowerQ4 Plus

THD

CF

PEAK

MAX 1/2

MIN 1/2 f

Operating the instrument

Total harmonic distortion THD

U

Crest factor Cf

U

and Cf

I.

and THD

I.

I

Peak value U

Pk

and I

Pk.

Maximal U

½RmsMax

Rms(1/2)

voltage U

Rms(1/2)Max

and maximal I

½Rms

current,

measured from last RESET (key: F2).

Minimal U

Rms(1/2) voltage U

Rms(1/2)Min

and minimal I

½Rms

current I

½RmsMin

, measured from last RESET (key: F2).

Frequency on reference channel.

Table 3.45: Keys functions - METER

Show measurements for phase L1

Show measurements for phase L2

Show measurements for phase L3

Show measurements for neutral channel

Summary of all phases measurements

Show phase-to-phase voltages measurements

Switch to METER view.

Switch to SCOPE view

Switch to TREND view (available only during recording)

Return to the “WAVEFORM RECORDER” setup screen.

Figure 3.36: Captured waveform scope screen

Table 3.46: Instrument screen symbols and abbreviations - SCOPE

U1, U2, U3,

Un, U12,

U23, U31

Current instrument time.

Show record number in MEMORY LIST.

True effective value of voltage – U

Rms(10).

I1, I2, I3, In True effective value of current – I

Rms(10).

Thd f

Total harmonic distortion THD

U

and THD

I.

Frequency on reference channel.

Time scale at beginning and the end of the scope screen

49

MI 2792A PowerQ4 Plus

Operating the instrument

Voltage/current scale and the top/bottom of the scope screen

Cursor position time.

Table 3.47: Keys functions - SCOPE

Zoom in.

Zoom out.

Select between the following signals:

Show voltage waveform;

Show current waveform;

Show voltage and current waveform in single graph;

Show voltage and current waveform in two separate graph.

Show measurement for phase L1

Show measurement for phase L2

Show measurement for phase L3

Show measurement for neutral channel

Summary of all phases measurements

Show phase-to-phase voltages measurements

Switch to RMS TREND view.

Select which waveform to zoom vertically (only in U/I or U+I graphs).

Set vertical zoom.

Move cursor position.

Return to the “WAVEFORM RECORDER” setup screen.

Figure 3.37: Captured waveform RMS trend screen