SPECIFICATIONS

Wiring diagram – Super AE air circuit breakers with electronic trip relay type S or M

The following circuit diagram shows the breaker with fully equipped accessories.

2000 V

Dielectric voltage

EN 50005

342 344 332 334 322 324 312 314

CLb CLa CLb CLa CLb CLa CLb CLa

Reset

1500 V

Dielectric voltage

Xa

L1

R+

TAL G / E

564 544 513

T5 T3 T0+

97

AL+

CL

CL CL CL

AL

EN 50005

CLc

341

CLc

331

CLc

321

CLc

311

R2– R1– T4– T2–

L3 L2 554 534

T1–

524

AL–

98

P S/I L

Cell switches

Description of terminal layout

Terminal

13/14, 23/24, 33/34,

43/44, 53/54

Code Function

AXa Auxiliary switch contact a

AXb Auxiliary switch contact b

413 / 414

U1 / U2

A1 / A2

C1 / C2

J1 / J2

713 / 714

TS Charged signal

MD Motor charging

CC Closing coil

SHT Shunt trip

UVT Under-voltage trip

ER Earth leakage trip

Remark

NO contact

NC contact

NO contact

Terminal

N1 / N2

Code Function

NP Neutral pole CT or ext. ZCT

Remark

M1 / M2

LM Load current measurement

97 / 98

AL OCR alarm contact

513/524/534/544

TRIP Trip indication contact L, S/I, G or E

513 / 554

PAL Pre-alarm indication contact

513 / 564

L1 / L2 / L3

311 – 344

TAL Temperature alarm indication contact

Signal

Signal

Signal

— Electronic trip relay unit control power supply See table on p. 35

— Cell switches (drawout type breakers only) e.g. for SHT trip

34

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

When using coil loads such as DC magnetic switches,etc.as operating voltage in the peripheral circuits,install diodes,surge absorbers,etc.as a countermeasure against surge (counter electromotive force) at the time of switching.On the

2000 V

Dielectric voltage drawout type,the control circuit terminal block should be moved to the left or right by 5 mm after the cables are connected.

OFF ON

OFF

M1 N1

LM+ CT+

713

ST+

J1

U+

C1 A1 U1 413 51 41 31 21 11 53 43 33 23 13

S+ CC+ M+ TS+ B10+ B9+ B8+ B7+ B6+ A5+ A4+ A3+ A2+ A1+

ON

UVT SHT CC

M

AX AX AX AX AX AX AX AX AX AX

LM– CT– ST– U–

M2 N2 714 J2

S– CC– M–

C2 A2 U2

TS–

414

B10–

52

B9–

42

B8–

32

B7–

22

B6–

12

A5–

54

A4–

44

A3– A2– A1–

34 24 14

SHT

Under-voltage trip

Charged signal Auxiliary switches

Power supply for electronic trip relay

Electrical connection

Voltage

AC

100–120 V

200–240 V

DC

100–125 V

DC

24–60 V

+

+

L1

Terminals

L2

L3

Description of symbols for the accessory

Description

Symbol Function

M

CC

SHT

UVT

Motor

Closing coil

Shunt trip device

Undervoltage trip device

S/I

Short-time delay trip indication lamp

Symbol Function

G or E

P

TAL

Ground fault trip or earth leakage indication lamp

Pre-alarm indication lamp

Unusual temperatur indication lamp

Self-holding relay

Wiring by factory

Wiring by customer

MITSUBISHI ELECTRIC

SUPER AE

35

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Fixed Type Breaker

Breaker types AE1000 to AE3200-SS/SH with standard connection (horizontal terminals)

Operating panel center

Control terminals

A B

N

eutral pole

268

3P 4P

144 88

N

eutral pole

H H H

J

4 x Ø 14

38

Breaker type

AE1000 – 1600-SS

AE2000 – 3200-SS

AE1000 – 3200-SH

C*

E

228

D*

F

Frontview

K

31

40

175*

290

288

Sideview

4P 3P

23

AE2000–3200-SS

AE1000–3200-SH

Rearview

AE2000–3200-SS

AE1000–3200-SH

3

4

3

4

Pole A

3 142

B

142

C

156

D

156

E

170

F

170

G

15

4 142 227 156 241 170 255 15

232

232

232

232

187

317

187

317

246

246

246

246

201

331

201

331

260

260

260

260

215

345

215

345

20

20

20

20

H

85

85

130 95

130 95

130 95

130 95

J

50

50

70

70

40

40

K

40

40

AE1000–1600-SS

38

17

2 - Ø 13

Main circuit terminal

38

17

4 - Ø 13

[mm]

Door frame and panel-cut

Panel-cut

Operating panel center

Door frame panel-cut

Operating panel center

8 - Ø 7

235 Breaker frame

247

271

Breaker frame

[mm]

36

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Breaker types AE1000 to AE3200-SS/SH with Vertical terminal adapter (VAT)

AE1000–1600-SS

Version A

85 85 85

N

eutral pole

T 50

4P 3P

X

Breaker

AE1000–1600-SS

AE2000–2500-SS

AE3200-SS

AE1000–2500-SH

AE3200-SH

X

108

123

123

153

153

20

25

20

25

T

15

Operating panel center

130 130

23

130

Version B

T

N

eutral pole

100

4P 3P

X

[mm]

Vertical terminal adapter (VTA)

Version A

Connecting area

38

15

Version B

38

2 - Ø 13

15

4 - Ø 13

15

Breaker

AE1000–1600-SS

AE2000–2500-SS

AE3200-SS

AE1000–2500-SH

AE3200-SH

Version

B

B

A

B

B

T

25

20

15

20

25

100

38

2 - Ø 13

Connecting area

115

38

15

5 - Ø 13

[mm]

MITSUBISHI ELECTRIC

SUPER AE

37

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Drawout Type Breaker

Breaker types AE1000 to AE3200-SS with standard connection (horizontal terminals)

Operating panel center

A

228

B

Control terminals

Disconnected position

Test position

51

35

E

Neutral pole

3P 4P

Operating panel center

K K K

N

eutral pole

L

15

59

42,5

C

200

*

D

Earth terminal

(gegenüberliegende Seite)

23

61

H

F

G

40

220

*

48

452

Drawout position

Breaker

AE1000–1600-SS

AE2000–3200-SS

4 x Ø14

Front view Side view

Pole A B C D E F G H J K L

3 150 150 149 149 311 368 366 172 15 85 50

4 150 235 149 234 311 368 366 172 15 85 50

3 243 195 239 194 311 368 366 172 25 130 103

4 243 325 239 324 311 368 366 172 25 130 103

AE1000–1600-SS

38

15

2 - Ø 13

4P 3P

Rear view

AE2000–3200-SS

38

15

Main circuit terminal

23

4 - Ø 13

[mm]

Drawout handle, door frame and panel-cut

Drawout handle Panel-cut

Operating panel center

Door frame panel-cut

8 - Ø 7 max.173

200

Ø 22

Breaker

235

247

271

[mm]

38

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Breaker types AE1000 to AE3200-SS with vertical terminal adapter

85 85 85

AE1000–1600-SS

Version A

N

eutral pole

T

50

131

AE2000–3200-SS

Version B

4P 3P

T

N

eutral pole

Operating panel center

130 130

23

130

100

Breaker

AE1000–1600-SS

AE2000–2500-SS

AE3200-SS

20

25

T

15

4P 3P

146

[mm]

Vertical terminal adapter (VTA)

Version A

Connecting area

38

15

Version B

38

2 - Ø 13

15

4 - Ø 13

15

Breaker

AE1000–1600-SS

AE2000–2500-SS

AE3200-SS

Version

A

B

B

T

15

20

25

100

38

2 - Ø 13

Connecting area

115

38

15

5 - Ø 13

[mm]

MITSUBISHI ELECTRIC

SUPER AE

39

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Drawout Type Breaker

Breaker types AE1000 to AE3200-SH with standard connection (horizontal terminals)

External accessory

(e.g. UVT controller)

243

Operating panel center

228

Control terminals

3P: 195

4P: 325

3P 4P

Neutral pole

Disconnected position

Test position

51

35

341 handle radius 100

Operating panel center

130

23

130 130

N

eutral pole

B

15

33

4 x Ø14

265

42,5

200

*

Drawout handle insertion port

3P: 220

4P: 350

2 x Ø12 screw M8 liegende Seite)

Front view

23

61

202

220

*

398

40

396

Side view

48

452

Drawout position

4P 3P

Rear view

38

15

Breaker

AE1000–2500-SH

AE3200-SH

A

20

25

B

95

103

4 - Ø 13

[mm]

Drawout handle, door frame and panel-cut

Drawout handle Panel-cut

Operating panel center

Door frame panel-cut

8 - Ø 7 max.173

200

Ø 22

Breaker

235

247

271

[mm]

40

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Breaker types AE1000 to AE3200-SH with vertical terminal adapter

Operating panel center

130 130

23

130

T

100

Neutral pole

4P 3P

146

Breaker

AE1000–2500-SH

AE3200-SH

T

20

25

[mm]

Vertical terminal adapter (VTA)

4 - Ø 13

15

38

Connecting area

115

38

15

5 - Ø 13

Breaker

AE1000–2500-SH

AE3200-SH

Vers.

B

B

T

20

25

[mm]

MITSUBISHI ELECTRIC

SUPER AE

41

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Fixed Type Breaker

Breaker typ AE4000-SSA (Fixed with vertical terminal)

Operating panel center

232 4P: 317 (3P:187)

268

Control terminals

Neutral pole

3P 4P

144 88

Panel

7

4 x Ø14

38

228

246

*

260 4P: 345 (3P: 215)

Operating panel center

152

31

11

Front view

23

152

95

* Mounting pitch

Neutral pole

31

136

40

175

*

290

31

11

Operating panel center

145

288

Side view

30,5

145 145

95

10

Rear view 3-poles

Main circuit terminals

20

48

10

Rear view 4-poles

Door frame and panel-cut

Panel-cut

Operating panel center

Door frame panel-cut

8 - Ø 7

[mm]

5 - Ø 13,5

235

247

271

[mm]

42

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Drawout Type Breaker

Breaker typ AE4000-SSA (Drawout with vertical terminal)

Operating panel center

243

228

4P: 325 (3P: 195)

3P

Control terminals

4P

Neutral pole

311

51

35

Disconnected position

Test position

15

59 239

42,5

200

*

4 x Ø14

4P: 324 (3P: 194)

Front view

23

190

Operating panel center

190

* Mounting pitch

52

10

52

10

172 40

109

23 220

*

368

366

Side view

Operating panel center

170 170

43

170

48

452

Drawout position

11 11

197 242

Rear view 3-poles

Neutral pole

327

Rear view 4-poles

242

[mm]

Main circuit terminals

Connecting area

20

48

Drawout handle

Drawout handle, door frame and panel-cut

Panel-cut

Operating panel center

Door frame panel-cut

8 - Ø 7 max.173

200

Ø 22

5 - Ø 13,5

Breaker

235

247

271

[mm]

MITSUBISHI ELECTRIC

SUPER AE

43

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Fixed/Drawout Type Breaker

Breaker typ AE4000-SSC (Fixed with vertical terminal)

Operating panel center

Control terminals

232 317

Drawout handle insertion

268

144 88

42,5

195

Operating panel center

195

70

10

10

7

4 x Ø14

38

246

*

260

228

331

*

345

Front view

* Mounting pitch

Breaker typ AE4000-SSC (Drawout with vertical terminal)

Operating panel center

Control terminals

243 325

228

31

136

Side view

40

175

*

290

288

311

Panel

Inside of the panel

(thickness 1.6 to 3.2)

51

35

Disconnected position

Test position

Rear view

[mm]

42,5

195

70

10

10

Operating panel center

195

90

10

10

59 239

42,5

200

*

4 x Ø14

324

Drawout handle insertion port

Front view

Earth terminal

(on opposite side)

146

23

172

220

*

368

366

40

* Mounting pitch

Side view

48

452

Drawout position

25

Main circuit terminals

Fixed type Drawout type

Drawout handle, door frame and panel-cut

Drawout handle

* please check before mounting!

Panel-cut

Operating panel center

53

20

*

48 max.173

200

Ø 22

15

493

Rear view

Door frame panel-cut

8 - Ø 7

[mm]

5 - Ø 13

Breaker

Recommendation:

Fixed type:

Drawout type:

Main circuit terminals per pole: 3 × connection bus bar T × B: 10 × 150 mm

Main circuit terminals for pole L1, L3: 4 × connection bus bar T × B: 10 × 150 mm

Einschubtechnik: Main circuit terminals for pole L2 : 3 × connection bus bar T × B: 10 × 150 mm

235

Type

Fixed type

Drawout type

A

179

195

247

271

[mm]

44

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Breaker

Breaker types AE4000 to AE6300-SS with standard connection (vertical)

Operating panel center

28

373,5

228

Control terminal

3P: 458,5

4P: 588,5

3P

Neutral Pole

28

4P

Test position

Disconnect position

311

51

35

44

Neutral Pole

42,5

530

*

345,5

Befestigungsschrauben

2 x M12

Earth terminal schraube M8

6 x M12

395 3P: 480

4P: 610

4P

3P: 431,5

4P: 561,5

*

*

196

42,5

262

3P

Front view

Operating panel center

431,5

*

262

Mounting screws M12

* Mounting pitch

Erdungsanschlußschraube M8

(gegenüberliegende Seite)

Side view

15

123

23

172

220

*

40

368

366

48

400

Drawout position

53

25

103

25

X

Y

Type

AE5000-SS

AE6300-SS

Dimensions**

X Y

100

105

20

25

** please check before mounting!

5 -

Ø

13

Rear view

Main circuit terminals

[mm]

Drawout handle, door frame and panel-cut

Drawout handle Panel-cut

Operating panel center

Door frame panel-cut

8 -

Ø

7 max.173

200

Ø

22

Breaker

235

247

271

Breaker frame

[mm]

MITSUBISHI ELECTRIC

SUPER AE

45

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Dimensions – Accessory

External ZCT for load circuits

F

E

Type

C

D

E

A

B

H

J

F

G

230

60

104

200

323

250

47

72

92

370

108

104

200

460

400

47

72

92

500

108

104

200

600

550

48

72

92

A

[mm]

External ZCT for transformer ground wire

E

For M5

H

A

F

6

7,7

B

ZT15A – 40 A

7

30

100

A

B

ZT60A – 100 A

Type

A

B

C

D

G

H

E

F

15A

48

15

29

62

70

25

46

15

68

30

37

82

90

50

66

30

85

40

43

92

81

40

100

50

140

60

73

150

46

160

80

82

169

48

185

100

93

190

50

[mm]

Condenser trip device (COT)

Front view

90

Side view

Screw M4

UVT controller, external power supply (PS)

6.5

215 14.5

Terminal screw M3.5

Ø

104

45 45

4-R6

75

110,6

13,3

16

15,4

87

90

106

11

45

182.2

14.6

[mm] [mm]

46

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Operating Conditions, Technical Information

Insulation clearances at the supply side

When a short-circuit current is interrupted by the breaker,ionised gases flow out of the exhaust openings of the arc extinguishing chamber.This makes it necessary to observe the insulation clearance shown in the table on the right.

The clearances required for maintenance work have also been taken into consideration in the table.

Electrical equipment, appliances and screen

B B

C

Breaker type

Applicable voltage

A

Fixed type

Drawout type

C

B

D

A

B

C

D

AC 600 V

0

50

162

50

0

50

240

50

AC 660, 690 V

100

50

162

50

100

50

240

50

200

50

200

AC 690 V

200

50

200

[mm]

A clearance of 300 mm or more is necessary for inspection of the arc extinguishing chambers and main contacts.

The dimension D represents the wiring space required for the control terminal block.

Dimension B becomes larger when the breaker is fitted with the UVT controller, mechanical interlock, door interlock, etc. Further details available on request.

Normal service conditions

If all the following normal working conditions are satisfied (and not specified otherwise) the AE series air circuit breakers may be used:

Ambient air temperature

Range min.–5 °C to max.+40 °C (the average value however should not exceed +35 °C in any 24-hour period).

Altitude

2000 m (6600 feet) or less

Environmental conditions

The air must be free of dust and corrosive gases.Do not use and store in atmospheres with sulfide gas,ammonia gas etc.(H

2

S

0,01 ppm,SO

2

0,1 ppm,NH

3 not measurable).

The relative humidity should be of 85% or less at a max.of +40 °C.

Installation conditions

When installing AE series circuit breakers always follow the instructions provided in the catalogue and in the instruction manual.

Storage temperature

A range of max.+60 °C to min.-20 °C is recommended to store.

However,the average over 24 hours must not exceed +35 °C.

Replacement

Lifetime is approx.15 years.For detailed information please refer to the instruction manual.

Special service conditions

In case of special service conditions,modified circuit breakers are available (please specifiy when ordering).Service life may be shorter dependend on service conditions.

Special environmental conditions

Using breakers in a high temperature and/or humidity environment can result in deterioration of insulation durability and other electrical or mechanical features.Breakers used in such environments should be specially treated to a higher corrosion proof specification and against moistural fungus.Where corrosive gases are present in the environment it is recommended that breakers to a higher corrosion proof specification are ordered (further details on request).

Special ambient temperature

If the ambient temperature exceeds +40 °C,the continuous current rating must be reduced.The reduction value depends on the applicable standard (please refer to the following page).

Special altitude

When breakers are used at altitudes above 2,000 m the heat radiation rate is reduced,decreasing the operation voltage, uninterrupted current and breaking capacity.Reduced atmospheric pressure can also reduce insulation durability.

Further details available on request.

Installation in a separate cabinet

If the breaker is installed in a special cabinet,the following clearances have to be taken into consideration.

Rear plate

Upper plate

120 120

Door

Lower plate

Cabinet walls metal or plastic

Example:

The smallest possible cabinet dimensions for 3-pole Super AE breakers with up to 1600 A are:Hight=680 mm,Width=540 mm,

Depth=368 mm.

MITSUBISHI ELECTRIC

SUPER AE

47

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Internal resistance, reactance and power consumption (per pole)

Standard series "SS"

AE1000-SS

AE1250-SS

AE1600-SS

AE2000-SS

AE2500-SS

AE3200-SS

AE4000-SS

AE5000-SS

AE6300-SS

Breaker type

AE4000-SSA

AE4000-SSC

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Drawout

Drawout

Drawout

40

80

41

77

50

113

38

60

26

40

224

210

275

340

72

143

144

240

128

0.063

0.095

0.047

0.071

0.047

0.071

0.060

0.091

0.060

0.091

0.072

0.062

0.062

0.062

0.048

0.072

0.048

0.072

0.048

0.016

0.030

0.010

0.020

0.008

0.018

0.026

0.040

0.024

0.038

0.007

0.014

0.009

0.015

0.008

0.014

0.013

0.011

0.0085

Breaker type

AE1000-SH

AE1250-SH

AE1600-SH

AE2000-SH

AE2500-SH

AE3200-SH

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

Fixed

Drawout

High performance series "SH"

0.014

0.024

0.012

0.022

0.010

0.020

0.018

0.028

0.016

0.026

0.009

0.016

0.047

0.071

0.047

0.071

0.047

0.071

0.047

0.071

0.047

0.071

0.048

0.072

Deratings (A) by ambient temperature

Standard

DNV, BV ture= 45 °C)

60 °C

45 °C

50 °C

55 °C

60 °C

40 °C

45 °C

50 °C

55 °C

1000

1000

1000

1000

1000

1000

1000

1000

1000

1250

1250

1250

1250

1250

1250

1250

1200

1600

1600

1600

1550 (1600)

1200 (1250) 1500 (1600)

1600

1600

1550 (1600)

1500 (1600)

2000

2000

2000

2000

2000

2000

2000

2000

2000

2500

2500

2500

2450

2350

2500

2500

2450

2350

3200

3200

3200

3000

2900

3200

3200

3050

2900

4000

3650

3300

4000

3800

3650

3500

3300

4000

4000

4000

3900

3750

4000

4000

3900

3750

All data in the above table are based on test conditions, connecting methods and size of the mounting rails conforming to IEC947-2, EN60947-2, VDE0660 etc.

The figures in brackets ( ) in the table above indicate the reduced current values exclusive to AE-SH series.

4750

5000

5000

5000

4750

5000

5000

5000

5000

48

88

36

61

63

125

25

41

18

28

92

164

5200

6000

5750

5500

5200

6300

6000

5750

5500

Connection arrangements

The following connecting methods are available for the AE type air circuit breaker.

Mounting method

Connection Horizontal connection

Standard

Vertical connection

Optional

Front connection

Optional

Vertical terminal adapter

Accessory

Front terminal adapter

Optional

Fixed type

——— ———

(Standard)

(FIX-VTA) (FIX-FTA)

Drawout type

(Standard) (DR-VT) (DR-FT) (DR-VTA) (DR-FTA)

Remark

48

SUPER AE

MITSUBISHI ELECTRIC

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

SPECIFICATIONS

Specifications for marinal standards

SUPER AE

Rated current (A)

Rated insulation voltage (V) 50/60 Hz

Series Standard series "SS"

Breaker type AE1000-SS AE1250-SS AE1600-SS AE2000-SS AE2500-SS AE3200-SS AE4000-SSC AE4000-SS AE5000-SS AE6300-SS

I

N max

1000 1250 1600 2000 2500 3200 4000 4000 5000 6300

Ui 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000

Rated operating voltage (V) 50/60 Hz

Number of poles

Ir

LR

DNV with instantaneous trip

Ue

AC690V

AC600V

AC500V

AC690V

690

3

500

In

1000

65

50

50

690

3

50

65

50

690

3

65

50

50

690

3

85

50

50

65

690

3

85

50

50

65

85

50

50

65

690

3

In

1250 800

In

1600 1000

In

In

2000

In

2500 1600

In

3200

3

3200

3200

In

(fürLR)

3800

3500

690

3

690

3

690

3

2000

In

4000 2500

In

5000 3150

In

6300

51,1

67

86.6

87

133

87

133

87

133

Ics

(kA, eff, sym.)

GL with instan-

AC600V

AC500V

AC690V

AC600V

AC500V

65

50

65

65

50

65

65

50

65

50

65

65

85

85

50

65

65

85

85

50

65

65

85

85

I

CU

= I

CS

BV

NK

LR

DNV with instan-

GL

BV

NK

87

133

211

330

211

330

65

85

113

147

199

143

196

85

65

50

65

85

106

143

196

106

143

196

187

143

196

106

143

196

105

143

85

65

50

65

85

106

143

196

106

143

196

187

143

196

106

143

196

105

143

85

65

50

65

85

106

143

196

106

143

196

187

143

196

106

143

196

105

143

65

50

50

65

106

151

106

151

143

112

147

106

151

105

50

65

50

65

106

151

106

151

143

112

147

106

151

105

65

50

50

65

106

151

106

151

143

112

147

106

151

105

AC690V

AC600V

AC500V

AC600V

AC500V

AC690V

AC600V

AC500V

AC690V

AC600V

AC500V

AC690V

AC600V

AC500V

AC690V

AC600V

AC500V

AC600V

AC500V

87

133

211

330

211

330

87

133

211

330

211

330

* Further current ratings on request.

SUPER AE

Rated current(A)

Rated insulation voltage (V) 50/60 Hz

Rated operating voltage (V) 50/60 Hz

Number of poles

Adjustment range

(A) Ir

Series High performance series "SH"

Breaker type AE1000-SH AE1250-SH AE1600-SH AE2000-SH AE2500-SH AE3200-SH

I

N max

Ui

Ue

1000

1000

690

3

500

In

In

1000

1250

1000

690

In

3

1250 800

1600

1000

690

In

3

1600 1000

2000

1000

690

3

In

2000 1250

2500

1000

690

3

In

2500 1600

3200

1000

690

3

In

3200

I

Br. duty: O-t-CO-t-CO

CU

= I

CS

LR

NK

LR

NK with instan-

AC690V

AC600V

AC500V

AC600V

AC500V

AC690V

AC600V

AC500V

AC600V

AC500V

173

211

330

317

68

87

133

130

173

211

330

317

68

87

133

130

173

211

330

317

68

87

133

130

173

211

330

317

68

87

133

130

173

211

330

317

68

87

133

130

173

211

330

317

68

87

133

130

MITSUBISHI ELECTRIC

SUPER AE

49

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement

Table of contents