Datasheet | Mitsubishi LDT 323V Technical information

Add to My manuals
64 Pages

advertisement

Datasheet | Mitsubishi LDT 323V Technical information | Manualzz

LOW VOLTAGE AIR CIRCUIT BREAKERS

630AF~6300AF

:2004

07A

Mitsubishi Presents the WS Series, Satisfied with the High Demands of the 21st Century Global Market.

Best-Solution

Various line-up and

high flexibility

High-Reliability

Safety and reliability provided

High-Performance

One-rank higher breaking performance

Customer Friendly

Easy handling and retrofitted solution

■ Concept

■ Line up

■ Best Solution

■ High-Performance

High-Reliability

■ Customer Friendly

■ External appearance and skeleton product structure

■ Product Specification

■ Connections

■ Charging

■ Accessories

For breaker unit

For drawout type

■ Electronic trip relay

Feature

For general use: WS

For generator protection use: WM

For special use: WB

Accessories

Additional functions

Network

Electronic trip relay circuit diagram

Setting procedure

■ Wiring diagram

■ Outline dimensions

Drawout type

Fixed type

Panel-cut,Drawout handle,Terminal adapter

Neutral CT,External ZCT

ETR external units

■ Technical information

■ Ordering information

■ Service network

Line up ( 630 to 6300A )

Rated current (A) 630 1000 1250 1600 2000

AE630-SW AE1000-SW AE1250-SW AE1600-SW AE2000-SWA

2500 3200 4000

5000 6300

SW series —

AE2000-SW AE2500-SW AE3200-SW AE4000-SWA —

AE4000-SW AE5000-SW AE6300-SW

SH series AE630-SH AE1000-SH AE1250-SH

Note : Please contact us for the details of AE-SH series.

AE1600-SH AE2000-SH AE2500-SH AE3200-SH —

Through Flexible and Various Options,

To be Built up the Suitable Functions.

Electronic Trip Relay

Main setting module

1

WS1

WS2

WS3

General use

WM1

WM2

WM3

Generator protection use

WB1

WB2

WB3

Special use

1

2

3

LTD + STD + INST / MCR LTD + STD + INST / MCR INST / MCR only

Note : *For optimum protective coordination with upstream and/or downstream protective devices such as fuses and OCRs, WF relay (WF1/WF2/WF3) are provided.

As for the details about WF relay, please make inquiries.

Optional setting module

2

With optional setting modules, GFR, ER etc are added easily.

G1 E1 AP N5

Ground fault protection (GFR)

Earth leakage (ER)

(1)

2nd Additional Pre-alarm

Neutral pole

(2)

50% protection

Note (1) : combination with ZCT

(2) : With "N5" optional module, Neutral pole protection will be changed from 100% (standard) to 50%.

Power supply

3

It is neccessary for Display and

LEDs. (see page 19, 20.)

P1 100-240V AC•DC

P2 24-60V DC

P3 100-240V AC / 100-125V DC with output contact

P4

P5

24-60V DC with output contact

100-240V DC with output contact (SSR)

Additional function

EX1 Extension module DP1 Display TAL Temperature alarm

The TAL is operated by an unusual temperature of the breaker contacts.

Module for display and communication

Current,Voltage,Power,

Harmonics,Trip current,etc.

Note : The VT unit is required to display the measured data except the load current.

MCR-SW MCR switch

Making current release is possible with MCR switch.

■ Secure protection by actual effective value detection

For spread of electronic devices such as inverter, the actual effective value detection method is adopted, which is strong against deformed waveform and is detected from each phase independently .

Distorted current

Effective value conversion

Sin wave current

With interchangeable & add-on modules, flexible functions built up.

Network

Personal

Computer

MELSECNET/10

Interface card

PLC

By using various application software for PLC, users can also connect to the network

SCADA system.

MELSECNET/10

CC-Link ® / PROFIBUS-DP / MODBUS ®

Interface

Unit

I/O Unit

AE-SW

MDU

Eco Monitor Pro ME110NSR

Note : Some device types are excluded.

Interface unit

CC-Link

®

PROFIBUS-DP MODBUS

®

(RS-485)

BIF-CC BIF-PR BIF-MD

Communication items

Current, Voltage, Power, Harmonics, etc

Measurement / alarm Tripping cause/current

Alarm (PAL,TAL,Self diagnosis)

Breaker ON,OFF

Breaker control

Spring charge

ON/OFF

Breaker status

Drawout position

Note : The VT unit is required to display the measured data except the load current.

I/O unit

BIF-CON

ON, OFF, Spring charge, Digital input

Option to interface unit

I/O unit enables to turn ON/OFF the breaker and the spring charge via network.

And by addition of the drawout position switch, it is possible to transmit the breaker drawout position.

Display unit for Panel board

DP2

It has the same function as the breaker display unit.

In the case where the breaker is installed in the panel, it becomes possible to view the measurement information from the outside of the panel board.

Note : The VT unit is required to display the measured data except the load current.

VT unit

VT

VT unit enables to measure voltages, electric powers, harmonics and etc.

Electronic Trip Relay type code

Main setting module

WS1, WB1, WM1 AE630–1600-SW,

AE2000–3200-SW,

AE4000-SW

WS2, WB2, WM2 AE2000-SWA,

AE4000-SWA,

AE5000-SW

WS3,WB3,WM3 AE6300-SW

Optional setting module

G1: Ground fault protection

N5: Neutral pole 50% protection

E1: Earth leakage protection

AP: 2nd Additional Pre-alarm

NA: Without optional setting

Power supply

P1: AC

DC100-240V

P2: DC24-60V

P5: DC100-240V with output contact (SSR)

WS : General use

WM : Generator protection use

WB : INST/MCR only

P3: AC100-240V / DC100-125V with output contact

P4: DC24-60V with output contact

Additional function

Extension module(EX1)

Display(DP1)

Display onto panel board(DP2)

VT unit(VT)

Network

BIF-CC

BIF-PR

BIF-MD

Temperature alarm(TAL)

MCR switch(MCR-SW)

The safety of valuable circuits can be securely maintained.

Higher short circuit protection performance by improving breaking capacity

In case of 690V AC, Icu = Ics improved from 50 kA to 65 kA for AE630-SW~AE2000-SWA from 50 kA to 75 kA for AE2000-SW~AE4000-SWA from 50 kA to 85 kA for AE4000-SW~AE6300-SW

Wider choice coordination range by improving rated short-time withstand current

Icw (1s) improved from 65 kA to 75 kA for AE2000-SW~AE4000-SWA from 85 kA to 100 kA for AE4000-SW~AE6300-SW

(Former model) (New model)

(AE630-SW~AE2000-SWA)

(Former model) (New model)

(AE2000-SW~AE4000-SWA)

(Former model) (New model)

(AE4000-SW~AE6300-SW)

(Former model) (New model)

(AE2000-SW~AE4000-SWA)

(Former model) (New model)

(AE4000-SW~AE6300-SW)

AE630-SW

AE1000-SW

690V AC

AE1250-SW

AE1600-SW

600V AC

AE2000-SWA

~ 500V AC

AE2000-SW

AE2500-SW

AE3200-SW

AE4000-SWA

690V AC

600V AC

~ 500V AC

65

65

65

75

75

85

690V AC 85

AE4000-SW

AE5000-SW

AE6300-SW

600V AC 85

~ 500V AC 130

0 20 40 60 80 100 120 140

(kA)

Icu=Ics

Higher safety by improving insulation performance

Rated impulse withstand voltage (Uimp) for the main circuit is improved from 8 kV to 12 kV.

AE630-SW

AE1000-SW

AE1250-SW

AE1600-SW

AE2000-SWA

1s

2s

3s

AE2000-SW

AE2500-SW

AE3200-SW

AE4000-SWA

1s

2s

3s

AE4000-SW

AE5000-SW

AE6300-SW

1s

2s

3s

0

(Former model)

20 40

50

60

65

60

65

75

75

100

80

85

85

100

(kA)

Icw

(New model)

Higher reliability by High operating durability

Mechanical

The new models are sharply improved in mechanical durability compared to the former model.

Former model

New model

10000

AE630-SW AE1000-SW

AE1250-SW AE1600-SW

25000

25000

AE2000-SWA

AE2000-SW AE2500-SW

AE3200-SW

AE4000-SWA

AE4000-SW AE5000-SW

AE6300-SW

2000

0

5000

5000

10000

10000

(3-Pole)

10000 15000

20000

20000

20000 25000

(times)

Electrical

The new models (V2

) are sharply improved in electrical durability compared to the former model.

✽ V2:High durability models

Former model

New model (V2)

5000

AE630-SW AE1000-SW

AE1250-SW AE1600-SW

AE2000-SWA

1500 (3200A: 1000)

AE2000-SW AE2500-SW

AE3200-SW

AE4000-SWA

500

5000

6000

0 2000 4000 6000

8000

8000

12000

10000 12000

(times/500V AC)

For convenience

3 sizes

Size1

AE630

-SW

AE1000

-SW

AE1250

-SW

AE1600

-SW

AE2000

-SWA

Size2

AE2000

-SW

AE2500

-SW

AE3200

-SW

AE4000

-SWA

Size3

AE4000

-SW

AE5000

-SW

AE6300

-SW

Compact size AE2000-SWA!

The compact AE2000-SWA can reduce the panel size.

Volume and weight

AE2000-SS

(Former)

AE2000-SWA

(New)

The former model (AE-SS) can be retrofitted.

It is same as the former model (AE-SS) in installation dimension and outline dimension, and the former model can be replaced with the new one.

ACB main body with drawout frame can be replaced.

It can be installed to the existing connection bus bar without any special connection kit.

(Except AE2000-SWA, AE4000-SWA)

Interchangeable

Bus bar

Zero arc space

Arc exhaust to the outside of the breaker is drastically reduced for safer operation.

(AE630-SW~AE4000-SWA models

≤ 600V AC)

(refer to page 54 : Insulation distance)

Former model New model

Reverse connection available

Line and Load is not defined on the Main circuit terminals.

Therefore, reverse connection is available without any limitation.

Fixed type

AE-SW Series

3

9

4

6

8

2

7

AE1600-SW 3P

1

5

1 Arc extinguishing chamber

2 Control circuit terminal block

3 Electronic trip relay

4 OFF button

5 ON button

6 Padlock hook

7 Charging indicator

8 ON/OFF indicator

9 Manual reset button(Optional)

In case of the fixed type,Lifting hooks (HP) are attached.

9

Drawout type

AE-SW Series

3

4

7

8

5

AE1600-SW 3P

2

6

1

1 Cradle

2 Control circuit terminal block

3 Lifting hole

4 Charging handle

5 Drawout position indicator

6 Extension rail

7 Position lock

8 Aperture for the drawout handle

9 Drawout handle

In case of the drawout type, Drawout handle is attached.

Skeleton

10

7

9

8

3 4 5 6

28

31

30

29

1 2

12 11

26 27

13

24 25

14

15

21

22 23

16

18

17

20

19

Product introduction

1 2

Type Standard

AE630-SW

AE1000-SW

AE1250-SW

AE1600-SW

AE2000-SWA

AE2000-SW

AE2500-SW

AE3200-SW

AE4000-SWA

AE4000-SW

AE5000-SW

AE6300-SW

6

Mechanical accessories

Push button cover

Counter

Cylinder lock

Terminal cover

Door frame

Dust cover

Interphase barrier

Mechanical interlock

Door interlock

IEC 60947-2

EN 60947-2(CE)

VDE

JIS C 8201-2-1

GB 14048.2(CCC)

(Shipping Approvals)

LR

GL

BV

DNV

ABS

CCS

NK

7

Electronic trip relay

General use

WS type

Generator protection use

WM type

Special use

WB type

Optional

G1:Ground fault protection

E1:Earth leakage protection

AP:2nd Additional Pre-alarm

N5:Neutral pole 50% protection

3

Connection

Drawout type

Horizontal terminal

Vertical terminal

Front terminal

Fixed type

8

Relay accessories

Extension module

Display

Temperature alarm

MCR switch

Neutral CT

External ZCT

VT unit

1 Air circuit breaker

2 Cradle

3 CC-Link ® Interface unit

4 PROFIBUS-DP Interface unit

5 MODBUS ® Interface unit

6 I/O unit

7 Extension module

8 ETR unit

9 Main setting module

10 Optional setting module

11 Door frame (DF)

12 Dust cover (DUC)

13 Push button cover (BC-L)

14 Auxiliary switch standard (AX)

15 Auxiliary switch high capacity type (HAX)

16 Shunt trip device (SHT)

17 Closing coil (CC)

18 Under voltage trip device (UVT)

19 UVT-controller (U-CON)

20 Condenser trip device (COT)

21 Motor charging device (MD)

22 Counter (CNT)

23 Cylinder lock (CYL)

24 Door interlock (DI)

25 Mechanical interlock (MI)

26 Safety shutters (SST)

27 Safety shutter lock ( SST-LOCK)

28 Cell switch (CL)

29 Interphase Barrier (BA)

30 Horizontal terminal

31 Vertical terminal

4

Drawout type accessories

Cell switch

Shorting b-contact

Lifting hooks

Safety shutter

Safety shutter lock

Mis-insertion preventor

Test jumper

9

Network

CC-Link ® Interface unit

PROFIBUS-DP Interface unit

MODBUS ® Interface unit

I/O unit

5

Electrical accessories

Auxiliary switch

Motor charging device

Closing coil

Shunt trip device

Under voltage trip device

Condenser trip device

● Specification

Type

Frame size

Rated insulation voltage (Ui)

Rated operational voltage (Ue)

Rated impulse withstand voltage (Uimp)

Pollution degree

Number of poles

Rated current In (CT rating)

General use

Current rating adjustable (

0.5 to 1.0 × In 0.05 step

)

Current setting Ir (A) (40˚C)

(A)

(AC.V)

(AC.V)

(kV)

Generator protection use

(Current rating fixed)

AE630-SW

630

630

315-346.5-378-409.5-

441-472.5-504-535.5-

567-598.5-630 (Note 5)

160 ≤ Ir ≤ 630

AE1000-SW

1000

1000

500-550-600-650-

700-750-800-850-

900-950-1000

400 ≤ Ir ≤ 1000

AE1250-SW

1250

1000

690

12

3

3, 4

1250

625-687.5-750-812.5-

875-937.5-1000-1062.5-

1125-1187.5-1250

AE1600-SW

1600

1600

800-880-960-1040-

1120-1200-1280-1360-

1440-1520-1600

800 ≤ Ir ≤ 1250 1000 ≤ Ir ≤ 1600

Rated current of neutral pole

IEC60947-2

EN60947-2

BS

VDE

JIS C 8201-2-1

Ultimate breaking capacity

Icu (kA rms)

690V AC

600V AC

240-500V AC

690V AC with MCR 600V AC without

Instantaneous

240-500V AC

690V AC

500V AC

Rated service breaking capacity Ics (kA rms) %Icu

(A) 630 1000

Rated short time withstand current

Icw (kA rms)

Rated making capacity

Icm (kA peak) with MCR without

Instantaneous

690V AC

600V AC

240-500V AC

690V AC

600V AC

240-500V AC

690V AC

500V AC

1s

2s

3s

(ms)

(ms)

Maximum total breaking time

Maximum closing time

Number of operating cycles

With rated current

AC500V In

AC690V In

Connecting terminal

(Note 2) Without rated current

Horizontal terminal

Vertical terminal

Front terminal

Fixed type Outline dimension (mm)

H

×W×D

Drawout type

3-pole

4-pole

3-pole

Weight (kg)

(without Accessory)

Fixed type

Drawout type

(including cradle)

Cradle only

4-pole

3-pole

4-pole

3-pole

4-pole

3-pole

40

50

63

77

4-pole

Marine approval 3-pole

(Note 1) The columns for “without instantaneous” are the values when the bare main body and the external relay is combined.

(Note 2) The number of operating cycles without rated current also include the number of operating cycles with rated current.

(Note 3) AE2000-SWA, AE4000-SWA and AE4000-SW~AE6300-SW apply for only vertical terminal of connecting terminal.

(Note 4) This value is max. operating cycle for just ACB body not including any accessories.

(The max. operating cycles for the accessories like AX, MD,CC, SHT and UVT are half of this value.)

(Note 5) Products with low rating types is available.

5000

5000

25000 (Note 4)

410

×340×290

410

×425×290

430 ×300×368

430 ×385×368

41

51

64

78

26

30

(LR, GL, BV, DNV, ABS, NK, CCS)

143

143

143

143

52.5

52.5

65

60

50

40 (Note 6)

80

1250

65

65

65

65

65

65

25 (Note1)

25 (Note1)

100%

143

143

1600

42

52

65

79

AE 630-SW 3 kinds of products with low rating types is available.

• 250-275-300-325-350-375-400-425-450-475-500(CT 500A)

• 157.5-173.3-189-204.8-220.5-236.3-252-267.8-283.5-299.3-315(CT 315A)

• 125-137.5-150-162.5-175-187.5-200-212.5-225-237.5-250(CT 250A)

AE 2000-SW 2 kinds of products with low rating types is available.

• 800-880-960-1040-1120-1200-1280-1360-1440-1520-1600(CT 1600A)

• 625-687.5-750-812.5-875-937.5-1000-1062.5-1125-1187.5-1250(CT 1250A)

AE2000-SWA

2000

AE2000-SW

2000

AE2500-SW

2500

AE3200-SW

3200

2000 2000 2500

1000-1100-1200-1300-

1400-1500-1600-1700-

1800-1900-2000

1000-1100-1200-1300-

1400-1500-1600-1700-

1800-1900-2000 (Note 5)

1250-1375-1500-1625-

1750-1875-2000-2125-

2250-2375-2500

1000

690

12

3

3, 4

3200

1600-1760-1920-2080-

2240-2400-2560-2720-

2880-3040-3200

AE4000-SWA

4000

4000

2000-2200-2400-2600-

2800-3000-3200-3400-

3600-3800-4000

AE4000-SW

4000

4000

2000-2200-2400-2600-

2800-3000-3200-3400-

3600-3800-4000

AE5000-SW

5000

1000

690

12

3

3, 4 (HN, FN) (Note7)

5000

2500-2750-3000-3250-

3500-3750-4000-4250-

4500-4750-5000

AE6300-SW

6300

6300

3150-3465-3780-4095-

4410-4725-5040-5355-

5670-5985-6300

1250 ≤ Ir ≤ 2000 800 ≤ Ir ≤ 2000 1600 ≤ Ir ≤ 2500 2000 ≤ Ir ≤ 3200 2500 ≤ Ir ≤ 4000 2500 ≤ Ir ≤ 4000 3150 ≤ Ir ≤ 5000 4000 ≤ Ir ≤ 6300

2000 2000 2500 3200

75

75

85

75

75

75

45 (Note1)

45 (Note1)

100%

165

165

187

165

165

165

94.5

94.5

75

75

65

40 (Note 6)

80

1500

1500

1500

1500

20000 (Note 4)

1000

1000

-

(Note 3)

-

47

57

70

84

31

35

60

72

92

113

35

43

410

×475×290

410

×605×290

430 ×435×368

430 ×565×368

61

73

93

114

63

75

95

116

36

44

(LR, GL, BV, DNV, ABS, NK, CCS)

(Note 6) This value means the instantaneous breaking time at shortcircuit interruption.

As for accessories (SHT, UVT), refer to page 13 and 14.

(Note 7) 4(HN) means the neutral poles current capacity is 50% of the rated current, for 4 poles.

4(FN) means the neutral poles current capacity is 100% of the rated current, for 4 poles.

(Note 8) ( ) shows the value for 4P FN type.

(Note 9) Marine approval value is 138kA.

4000

500

500

2000 (4000) (Note8) 2500 (5000) (Note8) 3150 (6300) (Note8)

85

85

130 (Note9)

85

85

100

65 (Note1)

65 (Note1)

100%

187

187

286

187

187

220

143

143

100

85

85

50 (Note 6)

80

1000

1000

10000 (3P) / 5000 (4P)

-

(Note 3)

-

(Note 3)

-

430 ×439×368

430 ×569×368

81

99

108

136

49

61

-

414

×873×290

414

×1003(1133)×290

(Note 8)

480

×875×368

480 ×1005(1135)×368 (Note 8)

160

180 (200) (Note8)

160

180 (200) (Note8)

160

180 (200) (Note8)

233

256 (279) (Note8)

118

133 (148) (Note8)

233

256 (279) (Note8)

118

133 (148) (Note8)

240

263 (286) (Note8)

125

140 (155) (Note8)

(NK), available soon (LR, GL, BV, ABS)

(Remark) All models conform the isolating function according to IEC 60947-2.

Reverse connection is possible.

Over view (AE630~1600-SW, AE2000~3200-SW)

Connections

Type

Horizontal

Standard

Vertical

(VT)

Front

(FT)

Vertical terminal adapter

(VTA)

Front terminal adapter

(FTA)

Fixed type (FIX)

FIX-VTA FIX-FTA

Drawout type (DR)

DR-VT DR-FT DR-VTA DR-FTA

● Connection image : AE630~1600-SW, 3-pole type

Over view (AE2000-SWA, AE4000-SWA, AE4000~6300-SW)

Connections

Type

Vertical

(VT) Standard

Fixed type (FIX)

FIX-VT

Drawout type (DR)

DR-VT

Connection image : AE2000-SWA, 3-pole type

For AE2000-SWA, AE4000-SWA, AE4000-

SW, AE5000-SW and AE6300-SW models, vertical terminal only is available.

Available connections

Breakers

AE630-SW AE1000-SW AE1250-SW AE1600-SW AE2000-SWA AE2000-SW AE2500-SW AE3200-SW AE4000-SWA AE4000-SW AE5000-SW AE6300-SW

Connections

Horizontal

Fixed type

(FIX)

FIX-VT

FIX-VTA

FIX-FTA

Horizontal

DR-VT

Drawout type

(DR)

DR-FT

DR-VTA

DR-FTA

Manual charging

The closing spring is charged by the manual charging handle. The breaker is closed when the ON button is pressed, and opened when the OFF button is pressed.

When the closing spring is completely charged, the charging indicator will show

"CHARGED".

The indicator shows the ON or OFF state of the main contacts.

● The breaker cannot be closed while the OFF button is being pressed. (Safety feature)

OFF lock is available by padlock (See P7, P17) as standard.

1

Motor charging device (MD)

The closing spring is charged by an electric motor. When the breaker is closed, the spring is charged automatically (ON-charge method.) The closing coil (CC) is required to remotely close, and the shunt trip device is required to remotely open the breaker.

Manual charging operation is also possible.

Pumping prevention is assured both electrically and mechanically.

As the charging completion contact is separate from the electrical charging circuit, its function in the control scheme can be arranged as desired.

Charged signal

413

414

Control supply

U1

U2

Charging completion

switch

Charging limit

switch z M

Motor

Control relay

Motor charging circuit

Breaker

Please inquire as to further details of 24V DC and 48V DC.

OFF charging method

U1

Axb

Control supply

U2

OFF charging method is also available.

The closing spring is charged automatically when the breaker is opened. This is available only by externally connecting b contact (AXb) of the auxiliary switch to the motor charging circuit in series.

In case of DC power supply, please use high capacity auxiliary switch (HAX).

Polarity of DC circuit use

+

U1

U2

Motor charging rating

Rated voltage (V)

Applicable voltage range (V)

Applied voltage (V)

Inrush current(Peak value) (A)

Steady current (A)

Charging time (s)

Criterion for power requirement

(VA)

500

DC24

DC48

AC/DC

100-125

AC/DC

200-250

18 ~ 26.4

36 ~ 52.8

85 ~ 137.5

170 ~ 275

24

48

100

125

200

250

22

14

10(10)

12(12)

5(7)

6(8)

6

3

3(4)

3(4)

1(2)

1(2)

≤ 5

700

1000

700

1000

Values in parentheses show values for AE4000-SWA 4 pole and AE4000-SW ~

AE6300-SW.

We cannot manufacture AE4000-SWA 4 pole and AE4000-SW ~ AE6300-SW in DC

24V and DC 48V rating.

2

3

5

1

9

4

8

2

3

6

4

7

Closing coil (CC)

The closing coil is a device to close the breaker by remote control.

An interlock to prevent pumping is provided electrically.

CC circuit diagram

Rated voltage

(Applicable voltage range)

Operating voltage

Operating inrush current (VA)

Closing time (Note1)

Min. 80ms

Breaker CC unit

AC DC

A1

DC24-48V

(18~52.8)

– DC24V 3.0A (100W)

Control supply

One-pulse circuit

– DC48V 6.0A (200W) 0.08 s or less

A2

AC • DC common

100-250V

(75-275)

AC100V 0.7A (100VA)

AC250V 1.7A (200VA)

DC100V 0.8A (100W)

DC250V 1.8A (250W)

Diode rectifier is not used for control source 24~48V DC.

N o t e 1 ) In case of double rating of rated voltage, it is the value for the lower rating.

(Example) In case of DC24 to 48, it is operating time for DC24V.

Closing time means time from the initial energization of the closing coil up to the complete closing of the main contacts.

As CC is one-pulse driven, it is not necessary to insert AXb for burning prevention purposes. Inserting AXb will cause anti-pumping function to be ineffective.

CC

Shunt trip device (SHT)

The shunt trip device is a device to open the breaker by remote control. A cut-off switch is included.

Rated voltage

(Applicable voltage range)

DC24-48V

(16.8~52.8)

AC • DC common

100-250V(70-275)

AC380~500V

(266~550)

Operating voltage • Operating inrush current (VA)

AC DC

Operating time (Note1)

AC100V 0.4A (100VA)

AC250V 1.4A (150VA)

AC380V 0.5A (250VA)

AC500V 0.7A (300VA)

DC24V 2.5A (100W)

DC48V 6.0A (200W)

DC100V 0.6A (100W)

-

0.04 s or less

N o t e 1 ) In case of double rating of rated voltage, it is the value for the lower rating.

(Example) In case of DC24 to 48V, it is operating time for DC24V.

N o t e 2 ) Operating time for AE4000-SW~AE6300-SW is 0.05s or less.

SHT circuit diagram

Breaker Cut-off switch

Min. 40ms

C1

Control supply

C2 SHT

SHT unit

Diode rectifier is not used for control source 24~48V DC.

4

5

6

Under voltage trip device (UVT)

This is the device that automatically trips the breaker when the circuit voltage drops below the nominal voltage, and comprises UVT coil and UVT controller. There are 3 kinds of tripping time,

INST, 0.5s and 3.0s.

UVT circuit diagram

Rated voltage

AC100-120V

AC200-240V

AC380-460V

DC24V

DC48V

DC100-110V

DC120-125V

Frequency

50/60Hz

operating time

(time delay)

Pick-up voltage

Drop-out voltage

Trip function

Power consumption

65~85V

130~170V

45~70V

90~140V

Inst(0.2s)

0.5s(Min.)

3.0s(Min.)

247~323V

15.6~20.4V

171~266V

10.8~16.8V

31.2~40.8V

21.6~33.6V

With open circuit of

DT1,DT2 terminals.

65~85V

78~102V

45~70V

54~84V

20VA

Note1) In case of 380-460V AC, the external unit is attached additionally.

Note2) The operating time is a guarantee value when it drops from 85% or more of rated voltage.

Note3) Time delay should be allowed for 1.5s between applying the voltage to the UVT and closing the breaker.

Note4) If a remote trip function is required, remove the shorting bar (DT1 DT2) and connect a normally closed switch, rated 0.5A at 150VDC across them.

Note5) Usage ambient temperature should be in the range from max. 40 °C to min. -5°C.

Trip button

~

D1

D2

DT1

UVT controller

UVT coil

DT2 max.2m

Breaker

UVT circuit diagram (In case of AC380~460V)

~

IN1 OUT3

External unit

(attached to

UVT controller)

IN2 OUT4

Trip button min.

0.2s

max.2m

D1

D2

DT1

DT2

UVT controller

Breaker

UVT coil

OCR alarm (AL) is provided as standard if ETR is equipped. OCR alarm (AL) is the contact (1a) of short-time operation (30ms), being output when the breaker is tripped by the electronic trip relay.

Two types of automatic reset type (standard) and manual reset type (optional) are available. When ordering, specify either automatic reset or Manual reset.

Switch rating

AC

DC

Voltage (V)

240

125

240

125

30

Resistive load

Current (A)

Inductive load

3

5

0.2

0.4

4

2

3

0.2

0.4

3

Note1) Though the control power supply is unnecessary to activate OCR alarm (AL), the self-holding circuit is necessary since the contact output is activated for the short time (30ms).

Note2) This works when tripping occurs in LTD, STD, INST, GFR or ER.

Note3) If any continuous output of OCR alarm (AL) is necessary, use the trip indicator (TI) output contact of the electronic trip relay.

97

98

OCR alarm switch

OCR alarm (AL) [

MRE : Manual reset type

]

On the manual reset type (optional), the gray manual reset button on the front side of the breaker will stick out to continuously output OCR alarm (AL) if the breaker is tripped by the electronic trip relay. After tripping, the breaker can not be turned on unless the manual reset button is pressed for resetting.

Auxiliary switch

Standard (AX) • High capacity type (HAX)

This is the contact that remotely indicates the ON or OFF status of the breaker.

Switch rating

Voltage (V)

AC

460

250

125

250

125 DC

30

Maximum contacts

Current (A)

Standard (AX)

Resistive load Inductive load

High capacity type (HAX)

Resistive load Inductive load

5

10

10

0.3

0.6

10

2

10

10

0.3

0.6

6

5

10

10

3

10

10

2.5

10

10

1.5

6

10

5a5b 5a5b

Change-over sequence

Breaker state

ON

OFF a-contact (NO)

ON

OFF b-contact (NC)

OFF

ON

The a and b conacts may turn simultaneously to ON instantaneously at the time of changing the contact;

Pay attention to the contact state when designing circuits.

The chattering time at the time of contact ON-OFF is below 0.025 s.

For special environment specification, the contact capacity gets deteriorated.

Make inquiries for more details.

7

8

9

Push button cover (BC-L)

The cover prevents careless manual operation (ON,OFF) of the push buttons.

BC-L can be locked by a padlock (The padlock should be supplied by the customer.)

For the suitable size of a padlock, refer to Page 17.

Cylinder lock(CYL)

The breaker is locked OFF with the cylinder lock.

Since it is an interlock which only allows the key to be removed when the breaker is locked off, it can be used for interlocking two or more breakers.

Counter(CNT)

The open/close operations of the breaker are shown by a 5 digit counter.

Door frame(DF)

The door frame improves the appearance, after cutting out the panel door to install the breaker.

As for panel cut-out dimensions, refer to page 49.

Door interlock(DI)

The panel door cannot be opened unless the breaker is open position.

A wire type mechanical interlock allows flexibility in positioning breakers in the switchboard.

The parts of the Door panel should be supplied by the customer.

DI can not be installed by combining with "Mechanical interlock(MI)for 3 breakers."

Interphase Barrier(BA)

This enhances the interphase insulation between the terminal portions of the breaker, and prevents short-circuit due to conductive inclusion or dust. It can be attached and detached easily. As for its availability, refer to the following table.

Fixed type

Drawout type

Type

(FIX)

(DR)

Horizontal (FIX)

Horizontal (DR)

Connections

Vertical terminal (FIX-VT)

Vertical terminal adaptor (VTA)

Front terminal adaptor (FIX-FTA)

Vertical terminal (DR-VT)

Front terminal (DR-FT)

Vertical terminal adaptor (VTA)

Front terminal adaptor (DR-FTA)

Available for the insulation

AE630-SW~

AE1600-SW

Available for separating terminals

AE2000-SWA

AE2000-SW~

AE3200-SW

AE4000-SWA

▲ ▲

Not existing type – Attachment is impossible

AE4000-SW~

AE6300-SW

Terminal Cover(TTC)

The transparent terminal cover prevents from careless touching to the live control terminals.

Protection degree is IP20.

Breaker layout(630AF-4000AF)

Vertical installation

Breaker

47(Max.) 134

Mechanical interlock (MI)

This is the device to prevent parallel charge of 2 or 3 units of breakers, and it can interlock the breakers mechanically without fail.

All combinations are available among any models from AE630-SW to AE4000-SWA.

Please make inquiries about installation to AE4000-SW~AE6300-SW.

Further the interlock is possible among the different connection types or poles, such as fixed type or drawout type, 3 pole or 4 pole.

In combination with electric interlock, the higher safety interlock system can be secured.

● In case of drawout type,the interlock works at "CONNECTED" position, and in another position the interlock is released, which assures easy maintenance and inspection of the breaker.

● When turning OFF one breaker and then turning ON another breakers, please take an interval 0.5 seconds or more.

● MI for 3 breakers can not be installed by combining with Door Interlock (DI).

Horizontal installation

(mm)

Interlock combinations

Switching states (for 2 ACBs)

Type 1 2 3

ACB1

ACB2

: ACB open

: ACB closed

2 devices : 1 normal power supply and 1 emergency power supply

Case circuit

ACB1 ACB2

1000(Max.)

Switching states (for 3 ACBs)

Type 1 2 3

ACB1

ACB2

ACB3

3 devices : 2 sources and 1 coupling

4 5 6 7

ACB1 ACB2 ACB3

Type

ACB1

ACB2

1 2 3

ACB3

3 devices : 3 sources,only 1 device closed

4

ACB1 ACB2 ACB3

Type

ACB1

1 2 3 4 5

ACB2

ACB3

3 devices : 2 normal power supplies and 1 emergency power supply

ACB1 ACB2 ACB3

Condenser trip device (COT)

Even if the power supply fails, the breaker can be electrically opened by remote operation within a definite time. This device is used in combination with the shunt trip device (SHT).

Type

Rated input voltage (V)

Rated frequency (Hz)

Rated charging voltage (V)

Condenser capacity (

μF)

Note1

Voltage range

Power supply capacity (VA)

Charging time (s)

Trip limit time Note2

Paint color

Withstand voltage (1minute)

Applicable SHT type (Rated voltage)

As for outline dimensions, refer to page 49.

KF-100CD

AC100/110

50-60

140/155

KF-200CD

AC200/220

820

70~125%

1 VA max

1sec. max

30 sec.

Black

AC 2000V

AC . DC 100-250V

Note 1: The rated charging voltage is the voltage stored during condenser saturation. It is continuously supplied by the rectified voltage of the rated AC input voltage.

Note 2: The trip limit time means the time period in which the shunt trip device (SHT) can make a tripping operation once, even after the charged condenser with 100% supply voltage would be stopped to charge. It can be tripped up to 30 seconds.

Note 3: Usage ambient temperature is in a range of max. 40

°C to min.

-20

°C.

AC1

AC2

Transformer (In case of KF-200CD)

DC+

R1

C

R3

R2 LED

DC-

Open button

C1

SHT

C2

Circuit diagram

Dust cover (DUC)

Dust cover prevents the dust or water entering into the panel board from the breaker panel cut.

Protection degree is IP54.

2

Drawout interlock (standard)

This is the safety device that prevents insertion and drawout operation. When the breaker is ON, the drawout handle cannot be inserted, and insertion and drawout operation cannot be done unless the

OFF button is pressed.

Position lock (standard)

This is the device that locks automatically the drawout mechanism at "TEST" or "CONNECTED" positions during insertion and drawout operation. When the lock plate is pushed in, lock is released and operation can be continued.

φ5

35

(mm)

Outline dimensions

(reference)

Padlock

A padlock can be arranged at the lock plate. Thereby, it is possible to prevent the connection position from being changed unnecessarily. A padlock of

φ5 should to be supplied by customer. As for outline dimensions of the padlock, please refer to the left figure.

Operating position of drawout type

CONNECTED position TEST position DISCONNECTED position DRAWOUT position

● Both main and control circuits are connected.

Normal in use condition.

Lock plate is protruding

● Main circuit is disconnected, but the control circuit is connected.

● The breaker operation can be tested with the door closed.

●Lock plate is protruding

● Both main and control circuits are disconnected.

The door can be closed.

● This is the position for removing the breaker.

The breaker is drawn out of the cradle on the extension rails.

Cell switch (CL)

This is the switch to show the drawout position (CONNECTED, TEST, and DISCONNECTED) of the breaker. An arbitrary combination up to 4 pieces is available.

Switch rating Operating sequence

Drawout position of breaker

Display position of drawout operation

CL-C

(CONNECTED)

CL-T

(TEST)

CL-D

(DISCONNECTED)

DISCON

OFF

OFF

ON

Disconnected

TEST

ON

Connected

CONNECT

OFF

Note 1: The setting is available for change by customer later.

A preliminary setting of CL at factory shipment is as follows.

CL1:1C CL2:1C1D CL3:1C1T1D CL4:2C1T1D

ON

Voltage (V)

AC

460

250

125

250

DC 125

30

Maximum contacts

Standard pattern

CL1

CL2

CL3

CL4

CL-C

1

1

1

2

CL-T

1

1

Resistive load

5

Current (A)

Inductive load

2.5

CL-D

1

1

1

10

3

10

10

Total 4c max.

10

1.5

6

10

Shorting b-contact (SBC)

When moving the breaker from the connected to the test positions, this contact is used to short circuit auxiliary switch (AXb) thus maintaining the correct sequence of operation of the external control circuit. When ordering, SBC with the same number of contacts as auxiliary switches (AXb) will be provided.

Switch rating

AC

DC

Voltage (V)

250

125

250

125

30

Resistive load

Current (A)

Inductive load

10

10

2

3

0.2

0.4

4

0.2

0.4

3

Lifting hook(HP)

This is the metal fitting to suspend the main body when the breaker is removed from the drawout cradle. The fixed type breaker is equipped with HP as standard.

Safety shutter(SST)

The safety shutters cover the conductors (cradle side) and prevent contact with them when the breaker is drawn out.

Safety shutter lock(SST-Lock)

This kit is used to lock the safety shutters using 2 padlocks (the padlocks to be customer's supply).

The safety shutters close when the breakers drawn out to prevent accidental contact with the main contacts.

Mis-insertion preventor(MIP)

This prevents other breakers than specified from inserting into the cradle, and max.5 patterns are available.

Not available for AE4000-SW~AE6300-SW

Test jumper(TJ)

With the breaker taken out of its cradle, this device enables the breaker to be electrically opened and closed, and the operating sequence to be checked. 3m length of cable is equipped as standard shipment.

A

D

C

F

E

B

3

Power supply module

This module provides control source for

DISPLAY module,Trip indicator and several indicators (LEDs).

(Even when the control power source is off, the function of over current protection and ground fault protection are effective.)

There are two types of power supply modules, one is only of power supply function, the other is power supply function with output contact (6 contacts).

1

Main setting module

This module provides the function of over current protection.

It is possible to select the three setting module according to application. (see page 21-26)

Neutral protection of rated current (100%) function is standard at 4 pole breaker.

2

Optional setting module

(option)

Additional functions and characteristics can be selected by optional setting modules.

H

G

F

A

B

C

Load current LED

(standard)

This indicator displays the maximum current of phase.

D

E

Display

(option)

Several measuring data (current, voltage, power etc) and alarms can be displayed with this module.

Extension module

(option)

This module is required when installed VT unit, display module and each interface unit.

RUN LED, ERR. LED

(standard)

This indicator displays the ETR situation (Run or Error)

Trip indicator LED

(standard)

This indicator displays the trip cause.

F

Pre-alarm(PAL)

(standard)

This indicator displays the Pre-Alarm situation when exceed the setting current. When it installed power supply module with contact, the output contact of Pre Alarm is available.

* The output is reset when the electric current goes below the set level after an alarm is set off.

G

RESET button

(standard)

When push this reset button, trip indicator, and Pre-Alarm will be reseted. And when the instantaneous test by

MITSUBISHI special tester and push this reset button, as a result of LTD and STD function become ineffective.

H

TEST terminal

(standard)

This terminal already installed as standard. This terminal is used for testing by the field test device (Y-2000). (see page 30)

OCR alarm (AL)

(standard)

When it happen to trip by over current, ground fault ( GFR ) and Earth leakage ( ER ), it issue a warning alarm.

Neutral pole overcurrent protection (NP)

(standard)

When harmonics in load current are large, the current on neutral pole exceeding rated current may flow. Harmonics may cause some troubles. Neutral pole overcurrent protection prevents them by operating at 100% of rated current on neutral pole.

MCR:Making current release

(option)

Just under the breaker closing operation ( from open to close ), Instantaneous characteristic become effective, but after closing the breaker, instantaneous characteristic become ineffective.

When you order the MCR switch, MCR switch is built in the main body.

If MCR switch is built in the main body and the adjust dial of INST/MCR on main setting module is set the MCR position,MCR function become effective.

TAL

(option)

When the temperature of main contacts exceed normal temperature level, temperature alarm is indicated at LED ( on main setting module ) and output by contact ( only installed power supply with output contact ).

If TAL is installed in the breaker according your order, Temperature alarm ( LED ) function become effective.

When the temperature goes down within normal tempter level, the temperature alarm will be reset.

NCT

(option)

Neutral CT is required for Ground fault or Neutral pole protection, when 3 pole breaker is used for 3 phase 4 wires system.

ZCT

(option)

ZCT is required for a few amperes earth leakage protection, and is combining ER plug. (see page 28)

Characteristic table

2

1

NA

Nothing

G1

Ground fault

E1

Earth leakage

AP

2nd additional Pre-alarm

N5

Neutral pole

50% protection

WS

General use

LTD+STD+

INST/MCR

WM

Generator protection use

LTD+STD+

INST/MCR

WB

Special use

INST/MCR

Power supply module

Type Rating

3 alarm output

P1

P2

P3

P4

P5

100-240V AC • DC

24-60V DC

100-240V AC

100-125V DC

24-60V DC

100-240V DC

Nothing

Nothing

6 output contacts

6 output contacts

6 output contacts (SSR)

Note1:

Note2:

Over current protection and ground fault protection operates without control power source.

Factory setting of 6 output contacts is as follows.

LTD

Self-holding

STD/INST

Self-holding

G1/E1/AP

Refer to lower table

PAL

Automatic reset

TAL

Automatic reset

ERR

Automatic reset

ETR dial set G1 E1

TRIP side Self-holding Self-holding

ALARM side

Automatic reset

Automatic reset

AP

Automatic reset

Self-holding:

The output is maintained until it resets.

Automatic reset:

The output will be reset if it backs to normal condition.

CT rating table

Contact capacity(Type code P3, P4)

Voltage(V)

Current (A)

Resistive load cos

φ=1.0

Inductive load cos φ=0.4

L/R=7ms

AC

DC

240

120

125

30

1

1

0.1

1

0.5

1

0.05

1

Current capacity(Type code P5)

Voltage(V)

AC

DC

240

120

240

30

Normal current

0.1A

0.1A

0.1A

0.1A

Peak inrush current

0.3A

0.3A

0.3A

0.3A

ON resistance

(max.)

5 Ω

5 Ω

5 Ω

5 Ω

AE630-SW AE1000-SW AE1250-SW AE1600-SW AE2000-SWA

630A 1000A 1250A 1600A 2000A

250A 315A 500A 1250A 1600A

AE2000-SW AE2500-SW AE3200-SW AE4000-SWA

2000A 2500A

Note1: AE630-SW and AE2000-SW has low rating type.

Please refer to the “Ordering information sheet.” (Page 57-59)

Note2: Low rating type of AE630-SW is not available for the ground fault protection.

Note3: As for details of ratings, refer to page 9 and page 10.

3200A 4000A

AE4000-SW

4000A

AE5000-SW

5000A

AE6300-SW

6300A

Electronic trip relay(ETR) type code

Main setting module

WS1, WB1, WM1 AE630–1600-SW,

AE2000–3200-SW,

AE4000-SW

WS2, WB2, WM2 AE2000-SWA,

AE4000-SWA,

AE5000-SW

WS3,WB3,WM3 AE6300-SW

Optional setting module

G1: Ground fault protection

N5: Neutral pole 50% protection

E1: Earth leakage protection

AP: 2nd Additional Pre-alarm

NA: Without optional setting

Power supply

P1: AC

DC100-240V

P2: DC24-60V

P3: AC100-240V / DC100-125V with output contact

P4: DC24-60V with output contact

P5: DC100-240V with output contact (SSR)

WS : General use

WM : Generator protection use

WB : INST/MCR only

Additional function

Extension module(EX1)

Display(DP1)

Display onto panel board(DP2)

VT unit(VT)

Network

BIF-CC

BIF-PR

BIF-MD

Temperature alarm(TAL)

MCR switch(MCR-SW)

G

D

E

F

B

A

L

H

I

J

K

A Trip indicator LED

B Pre-alarm LED

C Temperature alarm LED

D Load current LED

E RUN LED

F ERR. LED

G Current setting dial

H Uninterrupted current setting dial

I LTD time setting dial

J STD pick-up setting dial

K STD time setting dial

L INST/MCR pick-up current setting dial

M Optional setting module

(P.27~29)

N Pre-alarm current setting dial

O RESET button (TEST L/S LOCK button)

P TEST terminal

C

M

Note: The figure shown WS type with G1 plug.

G1 is option.

O

P

N

Relation of setting dial

In (CT rating) Ir

Ig

(P.27)

Iu

Isd

Ii

Ip

Ip2

(P.29)

Load current LED

(60, 80, 100%, OVER)

Adjustable setting range

No.

Setting item Mark Adjustable setting range Accuracy

Factory default value

G Current setting Ir 0.5 ~ 1.0

(0.05step) x In (CT rating) — 1.0

H

I

Uninterrupted current

LTD time

Iu

T

L

0.8 ~ 1.0

x Ir (0.02step), Pick-up current : 1.15 x Iu

12–25–50–100– 150 s at Iu x 2

1.05 x Iu…Non Pick-up

1.25 x Iu…Pick-up

± 20%

1.0

150

J

K

L

N

STD pick-up current

STD time

INST/MCR pick-up current

Pre-alarm current

Pre-alarm time

Isd

Tsd

1.5–2–2.5–3–4–5–6–7–8–9–

0.5

10 x Ir

–0.4–0.3–0.2–0.1–0.06–0.06–0.1–0.2–0.3–0.4–0.5s

(I 2 t ON) (I 2 t OFF) at Isd x 1.5

AE630-SW~AE1600-SW

AE2000-SW~AE3200-SW

AE4000-SW

16 -12-10-8-6-4-2-2-4-6-8-10-12-16 x Ir

(INST) (MCR)

WS1

± 15%

± 20%

It operates in the range between 0.04 and 0.08s when the time set at 0.06s.

10

0.5 (I 2 t ON)

WS1…16 (INST)

Ii

AE2000-SWA, AE4000-SWA

AE5000-SW

12 -10-8-6-4-2-2-4-6-8-10-12

(INST) (MCR)

x Ir

WS2

± 15% WS2…12 (INST)

AE6300-SW

10 -8-6-4-2-2-4-6-8-10

(INST) (MCR)

x Ir

WS3

WS3…10 (INST)

Ip

Tp

Iu x 0.68 ~ 1.0 (0.04step) –

1/2 T

L

at Iu x 2 (after 1/2 T

L

OVER

, PAL contact output turns on.)

± 10%

± 20%

OVER

Upper figure and table denote the case optional MCR function is included.

■Operating characteristic curve (for general use : WS)

100

60

50

40

30

20

500

400

300

200

5000

4000

3000

2000

1000 PAL current : Ip

Iu x 0.68~1.0(0.04step)-OVER

±10%

Uninterrupted current : Iu

0.8~1.0 x Ir(0.02step)

LTD Pick-up

1.05 x Iu…Non pick-up

1.25 x Iu…Pick-up

10

5

4

3

2

1

.5

.4

.3

.2

PAL time : Tp

T

L

/2

±20%(at Iu x 2)

STD pick-up current : Isd

Ir x 1.5-2-2.5-3-4-5-6-7-8-9-10 ±15%

STD time : Tsd Note1

0.06-0.1-0.2-0.3-0.4-0.5(s)

±20%

(at Isd x 1.5)

.1

.1

.05

.04

Current

LTD Pick-up, Ip…% of Uninterrupted current Iu

I 2 t ON

(ramp)

I 2 t OFF Iu, Isd, Ii………% of Current setting Ir

.03

.02

Note1 When Tsd="0.06"setting,operating time is 0.04~0.08s.

I 2 t is selectable ON or OFF.

INST/MCR pick-up current : Ii

Ir x 2-4-6-8-10-12-16

±15% WS1

Ir x 2-4-6-8-10-12

±15% WS2

Ir x 2-4-6-8-10

±15% WS3

Max. breaking time

(In case of AE4000-SW~

6300-SW, it is 0.05s)

.01

1 2 5 10 20 50 100 125 150 current (%)

200 500 1000 1600 2000 5000

Note :

The slope of LTD curve can be changed easily in case a relay for protective coordination (WF relay) is used instead of WS relay.

As for the details about WF relay, please make inquiries.

.01

10000

.05

.04

.03

.02

2

LTD time : T

L

12-25-50-100-150(s)

±20%

(at Iu x 2)

1

50

40

30

20

1

(h)

40

30

20

15

10

8

(min)

6

4

With MCR

10

.5

.4

.3

.2

5

4

3

2

(s)

1

D

E

F

B

A

C

K

G

H

I

J

A Trip indicator LED

B Pre-alarm LED

C Temperature alarm LED

D Load current LED

E RUN LED

F ERR. LED

G LTD pick-up current

H LTD time setting dial

I STD pick-up setting dial

J STD time setting dial

K INST/MCR pick-up current setting dial

L Optional setting module

(P.27~29)

M Pre-alarm current setting dial

N RESET button (TEST L/S LOCK button)

O TEST terminal

Note: The figure shown WM1 type with G1 plug and Display (DP1).

G1 and DP1 are options.

L

O

N

Relation of setting dial

In (CT rating) Ir (Fixed)

Ig

(P.27)

I

L

Isd

Ii

Ip

Ip2

(P.29)

Load current LED

(40, 60, 80, 100%)

M

Adjustable setting range

No.

Setting item

— Current setting

Mark

Ir

Adjustable setting range

0.63 ~ 1.0 x In (Adjust by factory : Fixed)

Accuracy

G

H

LTD pick-up current

LTD time

I

STD pick-up current

I

L

T

L

1.0–1.05–1.1– 1.15

–1.2 x Ir

15– 20 –25–30–40–60s at I

L

x 1.2

± 5%

± 20%

1.15

20

J

K

M

STD time

INST/MCR pick-up current

Pre-alarm current

Pre-alarm time

Isd 1.5–2–2.5–3–3.5–4–4.5– 5 x Ir

± 15%

5

Tsd

0.5

–0.4–0.3–0.2–0.1–0.06–0.06–0.1–0.2–0.3–0.4–0.5s

(I 2 t ON) (I 2 t OFF) at Isd x 1.5

AE630-SW~AE1600-SW

AE2000-SW~AE3200-SW

AE4000-SW

16 -12-10-8-6-4-2-2-4-6-8-10-12-16 x Ir

(INST) (MCR)

WM1

± 20%

It operates in the range between 0.04 and 0.08s when the time set at 0.06s.

0.5 (I 2 t ON)

WM1…16 (INST)

Ii

AE2000-SWA, AE4000-SWA

AE5000-SW

12 -10-8-6-4-2-2-4-6-8-10-12

(INST) (MCR)

x Ir

WM2

± 15%

WM2…12 (INST)

AE6300-SW

10 -8-6-4-2-2-4-6-8-10

(INST) (MCR)

x Ir

WM3

WM3…10 (INST)

Ip

Tp

I

L

x 0.68 ~ 1.0 (0.04step) –

1/2 T

L

at I

L x 1.2 (after 1/2 T

OVER

L

, PAL contact output turns on.)

± 5%

± 20%

OVER

Upper figure and table denote the case optional MCR function is included.

Pre-alarm current “OVER” setting is equal to 1.0.

Factory default value

Comply with ordering sheet

■Operating characteristic curve (for generator protection use : WM)

I I

Pre-alarm current : Ip

L x 0.68 ~ 1.0(0.04step)

±10%

LTD pick-up current : I

1.0-1.05-1.1-1.15-1.2

L

±5%

LTD time : T

L

15-20-25-30-40-60(s)

±20%

(at I

L x 1.2)

Pre-alarm time : Tp

T

L

/2

±20%(at I

L

x 1.2)

STD pick-up current : Isd

Ir x 1.5-2-2.5-3-3.5-4-4.5-5

±15%

STD time : Tsd Note1

0.06-0.1-0.2-0.3-0.4-0.5(s)

(at Isd x 1.5)

±20%

I I

L

, Isd, Ii …… % of Current setting Ir

Ip…% of LTD pick-up current I

L

Note1 When Tsd="0.06"setting,operating time is 0.04~0.08s.

I I

I I

I I t ON

(ramp)

INST/MCR pick-up current : Ii

Ir x 2-4-6-8-10-12-16

Ir x 2-4-6-8-10-12

Ir x 2-4-6-8-10

±15% WM1

±15% WM2

±15% WM3

B

A

E

F

D

C

K

J

G

H

A Trip indicator LED

B Pre-alarm LED

C Temperature alarm LED

D Load current LED

E RUN LED

F ERR. LED

G Current setting dial

H INST/MCR pick-up current setting dial

I Pre-alarm current setting dial

J RESET button

K TEST terminal

Relation of setting dial

In (CT rating) Ir

Ig

(P.27)

Ii

Ip

Ip2

(P.29)

Load current LED

(60, 80, 100%, OVER)

I

Adjustable setting range

No.

Setting item Mark Adjustable setting range

G

H

I

Current setting

INST/MCR pick-up current

Pre-alarm current

Pre-alarm time

Ir

Ii

Ip

Tp

0.5 ~ 1.0

(0.05step) x In (CT rating)

AE630-SW~AE1600-SW

AE2000-SW~AE3200-SW

AE4000-SW

16 -12-10-8-6-4-2-2-4-6-8-10-12-16 x Ir

(INST) (MCR)

WB1

AE2000-SWA, AE4000-SWA

AE5000-SW

12 -10-8-6-4-2-2-4-6-8-10-12

(INST) (MCR)

x Ir

WB2

AE6300-SW

10 -8-6-4-2-2-4-6-8-10

(INST) (MCR)

x Ir

WB3

Ir x 0.68 ~ 1.0 (0.04step) – OVER

75s at Ir x 2 (after 75s, PAL contact output turns on.)

Upper figure and table denote the case optional MCR function is included.

Accuracy

Factory default value

1.0

± 15%

± 10%

± 20%

WB1…16 (INST)

WB2…12 (INST)

WB3…10 (INST)

OVER

5000

4000

3000

2000

1000

500

400

300

200

100

60

50

40

30

20

■Operating characteristic curve (for special use : WB)

Pre-alarm current: Ip

Ir x 0.68

~

1.0(0.04step)-OVER

±10%

Pre-alarm time: Tp

75s

±20% at Ir x 2

.5

.4

.3

.2

.1

10

5

4

3

2

1

INST/MCR pick-up current: Ii

Ir x 2-4-6-8-10-12-16

±15% WB1

Ir x 2-4-6-8-10-12

±15% WB2

Ir x 2-4-6-8-10-

±15% WB3

.05

.04

.03

.02

.01

1

Current Ip, Ii …… % of Current setting Ir

2 5 10 20 50 100 125 current(%)

200

Max. time of let-through current

Max. Setting of

External OCR

Up to I cw

5

4

3

2

(s)

1

Up to I cw

.5

.4

.3

.2

2

1

50

40

30

20

1

(h)

40

30

20

15

10

8

(min)

6

4

10

.1

500

Max. breaking time

(In case of AE4000-SW~

6300-SW, it is 0.05s)

1000 1600 2000 5000

.01

10000

.05

.04

.03

.02

Accessories

Ground fault protection(GFR)

The ground fault protection (GFR) of several hundred amperes is possible. This function can be selected for trip and alarm (no trip). Power supply is necessary for this function, even if there is not power supply, it can function at 0.2xIn or higher.

Setting item

GFR pick-up current

GFR time alarm output

Mark Adjustable setting range

Ig

Tg

0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.91.0

x In

3 -1.5-0.8-0.5-0.3-0.15-<0.1 - <0.1-0.15-0.3-0.5-0.8-1.5-3s

TRIP ALARM

(at 1.5 x Ig)

Accuracy

Factory default value

±20% 1.0

±20%

3s (TRIP)

— TRIP side : Self-holding/ALARM side : Automatic reset —

TRIP side

(Self-holding)

Neutral CT(NCT)

Only use for AE-SW

The Neutral CT is used for ground fault protection when the 3 pole breaker is used on a 3 phase 4 wires system and for over current protection on N phase. Please use this CT in combination with ground fault protection (GFR). As for outline dimensions, refer to page 50.

The length of the cable (attached) for NCT is 2m.

GFR function block diagram (In case of 4pole breaker)

ACB

Alarm contact output

513

544

Block diagram with NCT function

ETR

Alarm contact output

513

544

ETR

P1

P2

Control power supply

ACB

P1

P2

Control power supply

NCT

NCT type name

ACB type name / CT rating

AE630-SW 630A

AE1000-SW 1000A

AE1250-SW 1250A

AE1600-SW 1600A

AE2000-SWA 2000A

AE2000-SW 1250A

AE2000-SW 1600A

AE2000-SW 2000A

AE2500-SW 2500A

AE3200-SW 3200A

AE4000-SWA 4000A

As for outline dimensional drawing, refer to page 50.

Applicable NCT type name

NCT06

NCT10

NCT12

NCT16

NCT20

NCT25

NCT32

NCT40

Ground fault protection characteristics

30

20

10

8

6

5

4

3

2

0.1

Pick-up current : Ig

In x 0.1~1.0

±20%

(0.1step)

3.0 ±20%

1.0

1

Ground fault time : Tg

< 0.1-0.15-0.3-0.5-0.8-1.5-3.0s

.5

.4

.3

.2

.1

0.15

±20%

<0.1

(0.04~0.1)

.05

.04

.03

.02

10 20 50 100 150 200 300

Ground fault current (% of CT rating In)

500 1000

Earth leakage protection(ER)

By combining the ETR with earth leakage protection (ER) and External ZCT, earth leakage protection is possible. Earth leakage protection, earth leakage tripping and earth leakage alarm can be selected. Control supply is necessary for this function.

Setting item

ER pick-up current

ER time alarm output

Mark Adjustable setting range

I Δ n 1A-2A-3A-5A10A

Accuracy

Factory default value

+0%

–30%

10A

Te

3 -1.5-0.8-0.5-0.3-0.15-<0.1 - <0.1-0.15-0.3-0.5-0.8-1.5-3s

TRIP ALARM

(at 1.5 x I Δ n)

±20%

3s (TRIP)

TRIP side : Self-holding/ALARM side : Automatic reset —

TRIP side

(Self-holding)

External ZCT

This option is used to detect several amperes of earth leakage when use in combination with a electronic trip relay that has the earth leakage tripping (ER) option.

Two methods are available. The first is where the all load conductors pass through the ZCT.

The other method uses a smaller ZCT through which the supply transformer's ground wire passes through to earth.

ZCT for load circuit

ZCT type name

ZCT163

ACB type name

AE630-SW ~ AE1600-SW 3-pole

ZCT323

AE630-SW ~ AE1600-SW 4-pole

AE2000-SW ~ AE3200-SW 3-pole

ZCT324 AE2000-SW ~ AE3200-SW 4-pole

As for outline dimensions refer to page 50. Make choice of suitable ZCT in comformity to the BUSBAR size.

ER function block diagram (for load circuit method)

Earth leakage protection characteristics

30

ZCT for transformer ground wire

ZT15B ZT30B ZT40B ZT60B ZT80B ZT100B

ACB

20

ZCT

Pick-up current : I Δ n

1-2-3-5-10A

+0

-30%

513

544

Alarm contact output

ETR with ER

Z1

Z2

P1

P2

Control power supply

10

8

6

5

4

3

2

1A

3.0

±20%

10A

1 ER function block diagram (transformer ground wire method)

ACB

Earth leakage protection operating time :Te

<0.1-0.15-0.3-0.5-0.8-1.5-3.0s

ETR with ER

.5

.4

.3

.2

ZCT

Z1

Z2

513

544

Alarm contact output

P1

P2

Control power supply

.1

0.15

±20%

<0.1

(0.04~0.1)

.05

.04

.03

.02

0.7

1 2 3 5 7 10

Earth leakage current (A)

20 50 100

Accessories

2nd Additional Pre-alarm (AP)

The Pre-Alarm (1st) function already installed in standard breaker, the 2nd additional Pre-Alarm function can be installed as option, thereby it is possible to monitor (observer) electric circuit in more detail by 2nd additional Pre-Alarm function.

Setting item Mark

2nd Additional

Pre-alarm pick-up current

Ip2

Adjustable setting range Accuracy

Factory default value

0.5-0.6-0.7-0.8-0.84-0.88-0.92-0.961.0

x Iu WS

±10%

WS

0.5-0.6-0.7-0.8-0.84-0.88-0.92-0.961.0

x I

L

WM

±5%

WM

1.0

2nd Additional

Pre-alarm time

Tp2

0.9

-0.8-0.7-0.6-0.5-0.4-0.3 x T

L

- 5-10-15-20-30-40-60s

(x T

L

) (FLAT)

±20%

0.9 (x T

L

)

Pre-alarm timing chart

Current

Ip

PAL LED

PAL OUT

(contact output)

Blinking

1/2 T

L

Current

Lighting

ON OFF

Neutral pole 50% protection(N5)

Neutral pole overcurrent protection (operating at 100% of rated current) come already eqipped with

ETR as standard features.

But if you would like to operate at 50% of rated current on neutral pole, neutral pole 50% protection is availabe with this optional module unit.

MCR switch (MCR-SW)

If MCR switch is built in the breaker and the dial for INST/MCR on Main setting module is set to the range of MCR position, MCR function is operative.

MCR function:

During a closing operation of the breaker, Instantaneous characteristics is operative.

And it becomes inoperative when the breaker is in the closed position.

Temperature alarm (TAL)

If TAL sensor is built in the breaker, temperature alarm is operative. When the temperature of main contact exceeds normal level, temperature alarm is indicated by LED on main setting module and also the output contact is made energize if power supply with output contact is installed.

It is possible to know temperature rising which is caused by wear of main contact because TAL sensor is installed near main contact. When the temperature of main contact goes down to the normal level, temperature alarm turns off automatically.

Field test device (Y-2000)

The electronic trip relay can be checked by this field test device when the breaker is at test position or disconnect position. The breaker will trip when tested with this device.

Y-2000 specification

TEST ITEM

TEST SIGNAL RANGE

OUTLINE DIMENSION

TIMER

POWER SUPPLY

LTD,STD,INST,GFR,PAL

1% ~ 2500%

230(W) x 120(H) x 290(D)

0.000 ~ 999.999s

100 – 240V AC 50 / 60Hz

Additional functions

By adding the extension module unit in ETR, additional functions like measuring, display and communication become available.

List of extension unit

Name

Extension module

Display module (relay attachment)

Display module (panel attachment)

VT unit

CC-Link ® interface unit

PROFIBUS-DP interface unit

MODBUS ® (RS-485) interface unit

I/O unit

Drawout position switch

Type

EX1

DP1

DP2

VT

BIF-CC

BIF-PR

BIF-MD

BIF-CON

Description

Base module for display and interface function (indispensable)

Display module for ETR

Display module for panel board

Module for measuring of voltage, active power and active energy

Interface unit for CC-Link ®

Interface unit for PROFIBUS-DP

Interface unit for MODBUS ® (RS-485)

Module for breaker remote control (Interface unit is required)

BIF-CL

Switch for detecting the drawout position of the breaker

(Interface unit and I/O unit are required.)

Selection samples of additional function modules

Name

Extension module

Display

Additional function

Type

EX1 DP1 or/and DP2

Load current Display

Voltage

Power

Energy

Harmonics current etc.

Communication CC-Link ®

PROFIBUS-DP

MODBUS ®

Display &

Communication

CC-Link ®

PROFIBUS-DP

MODBUS ®

Display

Communication CC-Link ®

PROFIBUS-DP

MODBUS ®

Display &

Communication

CC-Link ®

PROFIBUS-DP

MODBUS ®

VT unit

VT BIF-CC

( :required optional modules)

Interface unit

BIF-PR BIF-MD

DP2

(on the Panel)

DP1 EX1(inside breaker)

VT unit

(placed separately)

BIF-CC BIF-PR BIF-MD

Interface unit (placed separately)

Electronic trip relay(ETR) type code

Main setting module

WS1, WB1, WM1 AE630–1600-SW,

AE2000–3200-SW,

AE4000-SW

WS2, WB2, WM2 AE2000-SWA,

AE4000-SWA,

AE5000-SW

WS3,WB3,WM3 AE6300-SW

Optional setting module

G1: Ground fault protection

N5: Neutral pole 50% protection

E1: Earth leakage protection

AP: 2nd Additional Pre-alarm

NA: Without optional setting

Power supply

P1: AC•DC100-240V

P2: DC24-60V

P5: DC100-240V with output contact (SSR)

WS : General use

WM : Generator protection use

WB : INST/MCR only

P3: AC100-240V / DC100-125V with output contact

P4: DC24-60V with output contact

Additional function

Extension module(EX1)

Display(DP1)

Display onto panel board(DP2)

VT unit(VT)

Network

BIF-CC

BIF-PR

BIF-MD

Temperature alarm(TAL)

MCR switch(MCR-SW)

Wire system (when EX1 is specified)

EX1

3 φ3W

3

φ4W

Normal connection

Inverse connection

Extension module (EX1)

This is the base module that provides various additional functions with combining Display module

(DP1 / DP2), Interface unit (BIF-CC / BIF-PR / BIF-MD) and VT unit (VT).

1 Various measuring elements, high measuring accuracy

By adopting high-performance ASIC, various measuring elememts (load current, voltage, energy, harmonics, etc.) and high measuring accuracy are attained. Refer to page 34 for more details.

2 Communication function

2 display modules and 1 interface unit can be connected simultaneously with its advanced internal communication.

Display module (DP1/DP2)

This is the module that displays and sets various information, for example, displays of measurement, trip and alarm, setting of output contacts and so on.

1 Multi display of measuring element

It enables to easily monitor the comparison of each measuring element with its multi display

(4 phases multi display of load current and voltage) on one screen.

2 Two-color back light

Under trip or alarm, back light color changes from green to red automatically, which visually shows an abnormal situation.

3 Graphical display

By adopting dot matrix type LCD, graphical display such as bar graph display of load current, harmonic currents and characteristic curve is available.

There are 2 types of display module. One is the ETR attachment type (DP1). Another is the panel attachment type (DP2), which can be connected to extension terminals of control circuit with 2m cable. 2 units of display modules (DP1 and DP2) can be attached on one breaker.

(As for outline dimensions of DP2, refer to page 51.)

Note;

Extension module (EX1) is required.

VT unit (VT) is required to display the measured data except load current.

VT unit (VT)

VT unit enables to measure voltages, powers, energies, harmonic currents and etc.

by connecting the ETR with Extension module (EX1).

(outline dimensions are shown in page 52.)

Note;

The length of the cable attached for VT unit is 2m.

Network

2

BIF-CC (CC-Link ®)

Interface unit (BIF-CC/BIF-PR/BIF-MD)

These Interface units can expand the future possibility in various communication and Intelligent control.

1 Applicable to various open networks.

These units are applicable to various open network systems such as CC-Link ® ,

PROFIBUS-DP and MODBUS ® (RS-485), which can be built in easily.

2 Intelligent control by Multi-data communication

It comes into being the Intelligent control by Multi-data communication through these interface units to PLC/SCADA, which transfer the measurement Information, setting values, error information and trip and alarm informations.

Personal

Computer

MELSECNET/10

Interface card

By using various application softwares for PLC, users can also connect to the network SCADA system.

MELSECNET/10

CC-Link® / PROFIBUS-DP / MODBUS®

BIF-PR (PROFIBUS-DP)

BIF-MD (MODBUS ® (RS-485))

Interface

Unit

I/O Unit

PLC

Eco Monitor Pro ME110NSR

MDU

AE-SW

The length of the cable for interface unit is 2m.

Note:

Extension module (EX1) is required.

VT unit (VT) is required to transmit the measured data except load current.

Note: Some device types are excluded.

BIF-CON

I/O unit (BIF-CON)

The Input & Output Controlling Unit (BIF-CON) is available for the remote controlling and remote monitoring of the breaker condition through the various network systems.

With this BIF-CON unit in addition to the Interface Unit, it become possible to control the breaker remotely, like a ON or OFF operations or Spring-charging.

Function

Control

Monitor

Description

Breaker ON operation

Breaker OFF operation

Note

1a contact for Closing coil (CC)

1a contact for Shunt trip device (SHT)

(not applicable for AC380-500V rating)

Spring charge 1a contact for Motor charging (MD)

Digital Input (DI) monitoring

For BIF-CC and BIF-MD, Max. 3 contacts monitoring are available.

For BIF-PR, 1 contact monitoring is available.

Drawout position switch (BIF-CL)

With this Drawout position switch (BIF-CL) in addition to Interface unit and I/O unit (BIF-CON), the remote monitoring of draw-out position become available in case of the breaker draw-out type.

Function

Monitor

Description Note

Breaker Drawout position Position : Connect or Test or Disconnect

BIF-CL

: can be displayed by DP1/DP2 : can be displayed and set by DP1/DP2

Combination sample

+ + +

Type

➀ ➁ ➂

Note 1)

;EX1;DP1(;DP2)

➀ ➁ ➂

Note 1)

;EX1;DP1(;DP2),VT

➀Main setting module

➁Optional setting module

➂Power supply

Measurement

Load current ( ±2.5%)

Leakage current ( ±15%) Note 4)

Voltage ( ±2.5%)

Power (active,reactive,apparent) ( ±2.5%)

Power factor ( ±5%)

Energy (active,reactive) ( ±2.5%)

Harmonics current ( ±2.5%)

Frequency ( ±2.5%)

Trip history

LTD

STD

INST

GFR

ER

UVT

Alarm history

PAL1

PAL2

OVER

WS

NA AP G1 E1

WM

NA AP G1 E1

P1~P5

Note 2)

GFR

EPAL

ER

TAL

Note 3)

Characteristic setting (panel attachment product [DP2] only)

LTD

STD

INST

PAL1

PAL2

GFR

EPAL

ER

Setting

Contact outputs setting change

Date & Time

Demand time

Alarm holding method

Reset

Trip and alarm information

Measurement information (min. and max. values)

ETR information

Main / Optional setting module information

Error information

CT rating (In)

Phase line method

Normal connection or reverse connection

WB

NA AP G1 E1

WS

NA AP G1 E1

WM

NA AP G1 E1

P1~P5

WB

NA AP G1 E1

(3.5...19th)

Note 2)

Note 3)

Note 1 ) 2 units of display modules can be attached.

Note 2 ) Display is available only when UVT module is attached.

Note 3 ) Display is available only when TAL sensor is attached.

Note 4 ) Included the accuracy of ZCT.

Electronic trip relay circuit diagram

Upper side terminal

Test connector

➂ V2+

0V

V1+

ASIC

Constant voltage circuit

Microprocessor

Setting input

W.D.T.

Electronic trip relay (ETR)

Characteristic Setting module

A/D

CPU

I/O

Trip coil

Load current LED

60-80-100-OVER

PAL LED

RUN, ERR. LED

Trip indicator LED

V2+

0V

➇ Power supply with contact output

554

564

574

RESET

CIRCUIT

Control power circuit

FG

RS1

RS2

P1

P2

P4

513

524

534

544

N1

N2

Z1

Z2

N

Lower side terminal

➀ Power supply CT

Energy is supplied for the operation of the overcurrent tripping and ground fault tripping(GFR) function of the electronic trip relay.

➁ Current sensor coil

The current in each phase flowing through in the breaker is detected. A air core coil which has good linearity is achieved.

Power supply circuit

This part convert power supply CT energy to constant voltage for respective circuits in the ETR.

➃ ASIC

This amplifies signal detected by the current sensor coil, and detects ground fault current by vector composition.

➄ Microprocessor

The microprocessor integrates each phase current waveforms from the ASIC and performs processing for overcurrent protection and others.

➅ Characteristic setting module

The module for the characteristic setting of the ETR.

➆ Several LEDs

The load current LED give a figure of current in percent by CT energy.

Trip indicator and pre-alarm are indicated by control power supply.

RUN and ERR. LED indicate breaker's condition by control power supply or ten-odd percent of CT energy.

➇ Power supply with contact output

This outputs contact signal at fault cause (including pre-alarm) and at other alarms.

A control supply is necessary for this function.

Setting procedure

Press the screwdriver in the direction of the arrow to open the cover

1 Prepare a small flat tipped screwdriver.

Side view of the flat tip

ETR cover

Operating hole for resetting

(XI u )

Sealing hole

2 Insert the flat tipped screwdriver into the opening of the ETR cover.

Then, lightly turn the screwdriver to the upside as shown in the left figure, and the ETR cover will open.

3 There are two kinds of switches for characteristics setting and for trip indicator reset. They should be used as follows.

➀ Adjustable in steps

Rotary code switch is used. Do not set the switch at points between steps. The setting value is same when the switch is positioned at the thick line. (Set the switch with a torque of

0.02N

• m or below.)

➁ Push-button

This is for temporary operation, and press it with force of 3N or less.

Adjustable in steps

Push-button

4 When the characteristic is set up, use a device like a field tester, etc to make sure that the required characteristic has been set.

5 At sealing, seal the ETR cover by using the sealing hole at the top of the ETR cover.

Sealing hole

● The following diagram shown accessories fully equiped.

L1 L2 L3 N

Extension terminals

Power supply

Less than 2m

RS1 RS2 513 P1 P2 97 C1 A1

See Fig.1.

D2 D1 413 U1

Electronic trip relay(ETR)

Reset circuit Power circuit

Alarm contacts

SHT CC

UVT M

Main circuit

N1 N2 Z1 Z2

NCT * ZCT *

* Voltage forbid to be applied

FG

Dielectric test forbidden

P4 574 564 554 544 534 524 98 C2 A2 DT2

Short bar

DT1 414 U2

Open to trip

(less than 2m)

Electronic trip relay Control power circuit / alarm contact

OCR alarm

Electrical operation circuit

Terminal description

13

11

14

12

U1 U2

413 414

~

~

53

51

54

52

Auxiliary switch "a"

Auxiliary switch "b"

Motor charging

Charged signal

D1

DT1 DT2

A1

D2

A2

Voltage Input terminal of UVT

Trip terminal of UVT (Remote trip)

Closing coil

Shunt trip C1 C2

97

P1

P4

98

P2

OCR alarm

Power supply for ETR

FG of power supply (FG:Frame Ground)

Alarm reset (Trip cause LED, alarm contact) RS1 RS2

513

Z1

, 524 ~ 574

Z2

Alarm contacts

For external ZCT

For Neutral CT

(Note) N1 N2

Extension terminals

For external display DP2

For Interface unit

For VT unit

Note; Do not connect the NCT type CW-40LM (for AE-SS series).

CC

M

UVT

AX

AL

CLS

SBC

CL

Accessory Symbols

SHT Shunt tripping device

Closing coil

Motor(Motor charging device)

UVT coil

Auxiliary switch

OCR alarm switch

Charge limit switch

Shorting b-contact

Cell switch

Internal wiring

External wiring (user's wiring)

Control circuit connecter (drawout type)

51 41 31 21 11 53 43 33 23 13

Breaker

341 331 321 311

52 42 32 22 12 54 44 34 24 14

Breaker

344 342 334 332 324 322 314 312

Cell switch

Auxiliary switch(normal close) Auxiliary switch(normal open)

Fig.1

UVT controller wiring

100-120V AC type

200-240V AC type

DC types

380-460V AC type input input

D2 D1

+

IN2 IN1 external unit

OUT4 OUT3

D2 D1

Cell switch

Note;

● On the drawout type, the cables should have the length which allow the control circuit terminal block to be moved to the left or right by 5mm.

When a coil load is connected in the same control circuit as the ETR, surge absorbers are required to absorb the surge voltage.

● OCR alarm (AL)

The contact output of the OCR alarm(Standard type AL) is the one-pulse output and the output time is 30~50ms.

For this reason, this output needs self-holding circuit.

Closing coil (CC)

As CC is one-pulse driven, it is not necessary to insert AXb for burning prevention purposes.

Inserting AXb will cause anti-pumping function to be ineffective.

Under voltage trip device (UVT)

Use the switch that can open and close DC150V, 0.5A to remote trip.

Remote trip terminal has short bar at shipment, so remove it before using this function.

Disconnect the voltage input wires during dielectric testing of main circuit.

● voltage. (longer than 1sec.)

Drawout type AE630-SW,AE1000-SW, AE1250-SW, AE1600-SW

(mm)

Front view

Operating panel center Control terminal

(M3.5 screw)

150 235(150)

228

3P 4P

Neutral pole

Aperture for the drawout handle

Side view

Disconnected 54

Test 35

15

Front face of control terminal

Lifting hook hole

283

Horizontal terminal

(standard)

42.5

*200

149

4φ14

234(149)

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

Panel

48

452

Fully drawout position

40

*220

172

368

366

23

Inside of the panel

(thickness 1.6~3.2)

61

Earth terminal

M8 screw

Horizontal terminal

Operating panel center

85 85 85

Vertical terminal

Operating panel center

85 85 85

Neutral pole

50

Outline of breaker

Neutral pole

5 0

15

Outline of breaker

Vertical terminal

66

Front terminal

57 15

Neutral pole

Front terminal

Operating panel center

85 85 85

5 0

Insulation block

Outline of breaker

4P 3P

Main circuit terminal dimension

4P 3P

4P 3P

Horizontal terminal(standard)

Vertical terminal

Front terminal

38 Connecting area

15

2φ13

Drawout type AE2000-SWA

Front view

Operating panel center

150 235(150)

Control terminal

(M3.5 screw)

228

3P 4P

Neutral pole

Aperture for the drawout handle

Side view

Disconnected 54

Test 35

Front face of control terminal

Lifting hook hole

283

42.5

4-ø14

149

*200

234(149)

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

15

Panel

48

452

Fully drawout position

40

*220

172

368

366

Inside of the panel

(thickness 1.6~3.2)

23

104

Earth terminal

M8 screw

115

Operating panel center

115

10

Outline of breaker

Operating panel center

105 105

10

105

10

Neutral pole

Outline of breaker

3P

Main circuit terminal dimension

4P

38 Connecting area

15

(mm)

4φ13

Drawout type AE2000-SW, AE2500-SW, AE3200-SW

(mm)

Front view

Operating panel center

240

228

325(195)

Control terminal

(M3.5 screw)

3P 4P

Neutral pole

Aperture for the drawout handle

Side view

Disconnected 54

Test 35

Front face of control terminal

Lifting hook hole

283

Horizontal terminal

(standard)

Vertical terminal

239

42.5

*200

4φ14

324(194)

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

Horizontal terminal(standard)

Operating panel center

23

130 130 130

W

Outline of breaker

15

Panel

48

452

Fully drawout position

40

*220

368

366

172

23

61

83

Earth terminal

M8 screw

Dimensions

Type

Inside of the panel (thickness 1.6~3.2)

AE2000-SW AE2500-SW

AE3200-SW

57 T

T

20

25

(mm)

Vertical terminal

Operating panel center

130 130

23

130

T

Outline of breaker

Front terminal

Front terminal

Operating panel center

130 130

23

130

W

Insulation block

Outline of breaker

4P 3P

Neutral pole

4P 3P

Neutral pole

Main circuit terminal dimensions

Horizontal terminal(standard)

38 Connecting area

15

Vertical terminal

38 Connecting area

15

Neutral pole 4P 3P

Front terminal

34 Connecting area

15

Dimensions

Type

AE2000-SW AE2500-SW

AE3200-SW

W

95

103

(mm)

4φ13

5φ13 4φ13

Drawout type AE4000-SWA

Front view

Operating panel center

Control terminal

(M3.5 screw)

240

228

325(195)

3P 4P

Neutral pole

Aperture for the drawout handle

Side view

Disconnected 54

Test 35

Front face of control terminal

Lifting hook hole

283

Connecting busbar size

All poles:

T10xW150x4BUS/pole

42.5

*200

239

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

4φ14

324(194)

Operating panel center

190

23

190

52

10

Outline of breaker

Note) 11

15

Panel

452

Fully drawout position

48

40

*220

368

366

172

23

109

Earth terminal

M8 screw

Inside of the panel (thickness 1.6~3.2)

52

10

Operating panel center

170 170

43

170

Outline of breaker

Note) 11

(mm)

197 242

Neutral pole

327 242

3P 4P

Note) Spacers are not required when fastening connecting conductors (T10). The necessary contact area can be obtained with ACB terminal bent by tightening the screw.

Main circuit terminal dimension

48 Connecting area

20

5φ13.5

Drawout type AE4000-SW, AE5000-SW, AE6300-SW

28

Front view

Operating panel center

373.5

Control terminals

(M3.5 screw)

588.5(458.5)

228

3P

Neutral pole

4P

HN

28

Side view

Disconnected 54

Test 35

Front face of control terminal

283

Lifting hook hole

M12 Weld nut

Mounting angle

Insulation block

Drawout handle radius 100

15

42.5

395

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

*530

345.5

4-M12

610(480)

Aperture for the drawout handle

Fixing bolts

2-M12

*561.5(431.5)

196 262

42.5

235

Panel

48

400

Fully drawout position

262

Operating panel center

2-M12 for mounting

*431.5

W

Mounting angle

(non-magnetic steel)

172

23

Earth terminal

M8 screw

*220

368

366

123

Bus bar

Inside of the panel (thickness 1.6~3.2)

Main circuit terminal dimension

53 Connecting area

25

(mm)

25

103

28

4P

HN

3P

The mounting angle should be prepared by the customer.

4P FN type

Front view

503.5

Operating panel center

228

Control terminals

(M3.5 screw)

588.5

T

Outline of breaker

5φ13

Dimensions

Type

AE4000-SW AE5000-SW

AE6300-SW

W

100

105

(mm)

T

20

25

Neutral pole

28

Rear view

2-M12 for mounting

Neutral pole

Operating panel center

*692.5

262 262

88.5

235

262

Mounting angle

(non-magnetic steel)

*430.5

W

Drawout handle radius 100

42.5

525

*714

Side view dimensions are same as 3 pole.

399.5

6-M12

610

Aperture for the drawout handle

Fixing bolts

2-M12

*42.5

T

Fixed type AE630-SW, AE1000-SW, AE1250-SW, AE1600-SW

Front view

142

275

Operating panel center

227(142)

Control terminal

(M3.5 screw)

3P 4P

Neutral pole

4φ14

Earth terminal

M8 screw

(Left side)

228

*156

170

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

*241(156)

255(170)

Rear view

Side view

7

93.5

139

Panel

40

*175

290

288

Inside of the panel

(thickness 1.6~3.2)

31

40

Earth terminal

M8 screw

(Left side)

Neutral pole

85 85

Operating panel center

85

50

Outline of breaker

(mm)

4P 3P

Main circuit terminal dimension

38

Connecting area

17

2φ13

Fixed type AE2000-SWA

Front view Side view

142

Operating panel center

227(142)

275 Control terminal

(M3.5 screw)

3P 4P

Neutral pole

93.5

139

7

4φ14

Earth terminal

M8 screw

(Left side)

228

*156

170

*241(156)

255(170)

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

Panel

40

*175

290

288

Inside of the panel

(thickness 1.6~3.2)

31

108

Earth terminal

M8 screw

(Left side)

115

Operating panel center

115

10

Outline of breaker

Operating panel center

Neutral pole

105 105

10

10

105

Outline of breaker

(mm)

3P

Main circuit terminal dimension

4P

38

Connecting area

15

4-

φ13

Fixed type AE2000-SW, AE2500-SW, AE3200-SW

Front view

232

275

Operating panel center

Control terminal

(M3.5 screw)

317(187)

3P 4P

Neutral pole

Side view

93.5

139

7

4φ14

Earth terminal

M8 screw

(Left side)

*246

260

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

228

*331(201)

345(215)

Panel

40

*175

290

288

Inside of the panel

(thickness 1.6~3.2)

31

40

Earth terminal

M8 screw

(Left side)

Neutral pole

Operating panel center

130 130

23

130

95

Outline of breaker

(mm)

4P 3P

Main circuit terminal dimension

38 Connecting area

17

4-

φ13

Fixed type AE4000-SWA

Front view

Operating panel center

317(187) 232

275

Control terminal

(M3.5 screw)

3P 4P

Neutral pole

Side view

93.5

139

Connecting busbar size

All poles:

T10xW150x3BUS/pole

7

4φ14

Earth terminal

M8 screw

(Left side)

*246

260

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

228

Rear view

*331(201)

345(215)

Panel

40

*175

290

288

31

117

Earth terminal

M8 screw

(Left side)

Inside of the panel (thickness 1.6~3.2)

Operating panel center

152

31

Note) 11

10

23

152

Outline of breaker

Operating panel center

145 145

31

Note) 11

10

Neutral pole

30.5

145

Outline of breaker

(mm)

3P 4P

Note) Spacers are not required when fastening connecting conductors (T10). The necessary contact area can be obtained with ACB terminal bent by tightening the screw.

Main circuit terminal dimension

48 Connecting area

20

5φ13.5

Fixed type AE4000-SW, AE5000-SW, AE6300-SW

Front view

Operating panel center

366.5

275

Control terminals

(M3.5 screw)

581.5(451.5)

Neutral pole

3P

4P

HN

Side view

93.5

139

Bus bar

7

Earth terminal

M8 screw

(Left side)

*380.5

394.5

* : Mounting pitch

The numerals shown in parentheses are for 3 poles.

Rear view

228

Neutral pole

197

20

262

42.5

*595.5(465.5)

609.5(479.5)

4φ14

262

Operating panel center

100

20

Outline of breaker

Panel

40

*175

290

288

31

136

Earth terminal

M8 screw

(Left side)

Inside of the panel (thickness 1.6~3.2)

Main circuit terminal dimension

53 Connecting area

25

5φ13

4P

HN

3P

4P FN type

Front view

Earth terminal

M8 screw

(Left side)

Operating panel center

496.5

275

Control terminals

(M3.5 screw)

581.5

Neutral pole

Rear view

Neutral pole

263 263

Operating panel center

89

263

100

20

4φ14

228

*510.5

524.5

Side view dimensions are same as 3 pole.

*595.5

609.5

Panel cut-out, Drawout handle, Terminal adapter

Panel cut-out dimensions

Operating panel center

Door frame panel cut-out dimensions

Panel cut-out dimensions

8-

φ7

Outline

Operating panel center

7.7

Dimensions

Type

AE630-SW~AE1600-SW

(mm)

A

Fixed Type 175

AE2000-SW~AE3200-SW

AE2000-SWA, AE4000-SWA

Drawout Type 195

AE4000-SW~AE6300-SW

Fixed Type 179

Drawout Type 245

235

Breaker mounting frame

247

271

Breaker mounting frame

235

295

Vertical terminal adapter Front terminal adapter

AE630~1600-SW

38

φ13

AE2000~3200-SW

38

φ13

AE630~

1600-SW

AE2000~

3200-SW

25 φ13 25 25 25

φ13

42

T

15

15

φ13

100

38

Connecting area

Dimensions

Type

AE2000-SW,2500-SW

AE3200-SW max 173

200

T

20

25

(mm)

15

Drawout handle dimensions

Breaker

15

φ13

115

38

Connecting area

φ13

Mtg.holes

φ13 D D

Dimensions

Type

AE630-SW~1600-SW

Fixed

Up side type Down side

Drawout type

AE2000-SW,2500-SW

Fixed

Up side type Down side

AE3200-SW

Drawout type

Fixed type

Up side

Down side

Drawout type

C

258.5

145

145

258.5

145

145

258.5

145

145

95

95

95

103

D

50

(mm)

T

15

50

50

15

15

95

95

20

20

20

25

25

25

4-

R

6

Condenser trip device

Condenser trip device (COT)

17

2-M6 Mounting screw

4-M4 screw

(for wiring)

φ1

04

75

110.6

Front view

14.3

16

87

110

Side view

45 45

Drilling plan

2-

φ8

Neutral CT (NCT), External ZCT

630~2000A

97 5.5

M5 screw

51

Neutral CT (NCT)

2500~4000A

162 4

M5 screw

68

R2

Slit for M8 screw

28

122 Mounting pitch

142

7.7

9

38

66

Slit for M10 screw

R3

48

192 Mounting pitch

212

A

F

External ZCT for transformer ground wire

Terminals M3.5 screw

28

30

Terminals M3.5 screw

12

E

11

55

87

B

B

Slit for M5 screw

H

E

40

52

Dimensions

ZT15B

ZT30B

ZT40B

A

48

68

85

B

15

30

40

C

29

37

43

D

62

82

92

E

46

66

81

F

15

30

40

G

70

90

100

(mm)

H

25

50

50

Slit for M5 screw

100

A

70

90

Dimensions

ZT60B

ZT80B

ZT100B

A

140

160

B

60

80

185 100

C

73

82

93

D

150

169

190

(mm)

E

46

48

50

Slit for M8 screw

K

A

D

External ZCT for load circuits

C

Terminals M3.5 screw E

Dimensions

ZCT163

ZCT323

ZCT324

A

230

370

500

B

60

C

323

108 460

108 600

D

250

400

550

(mm)

E

47

47

48

72

92

UVT external unit

UVT external unit (AC380 ~ 460V)

30 30

Mounting bracket

Terminal

20~24

Height of wiring

Use the attached mounting bracket.

(Not applicable to

35mm IEC rail)

IN1 IN2

OUT

3

OUT

4

Terminal

UVT external unit

IN1

380-460V

AC

65

(mm)

OUT4

To AE-SW terminals of UVT controller

OUT3 30

90

30

Mounting ø4.5 hole

IN2

ETR external units

Display onto panel board (DP2)

(mm)

Operation display surface

64

48

Panel (Note) Note : Use the panel of thickness 1mm ~ 3.2mm.

51

64 max.

Panel attachment metal

64

R≤1

49

Upper side

Operation display surface side

Panel attachment metal

Fixed screw M3

DP2 connection cable connection position (connector)

CC-Link ® , MODBUS ® interface unit (BIF-CC, BIF-MD)

30 30

Mounting bracket

5

Surface plate hole dimension

(mm)

IEC35mm rail

Terminal

67.5

90

M3 terminal screws 35mm IEC rail holder

65

23.5

37.5

Terminal

Frame Ground

P1 P2 SLD

FG

DG DB DA

Power supply

(100-240V AC

DC)

CC-Link ®

30 30

Mounting φ4.5 hole

Frame Ground

P1 P2

Ter

COM

Ter

T/R-

FG

T/R+ SLD

Power supply

(100-240V AC

DC)

MODBUS ®

35mm IEC rail holder

I/O unit (BIF-CON)

30 30

Mounting bracket

5

IEC35mm rail

Terminal

M3 terminal screws

67.5

90

35mm IEC rail holder

65

23.5

37.5

Terminal

Input

K12 K22 K32 K11

C2 C1 A2 A1 U2 U1

Shunt trip

(SHT)

Closing coil

(CC)

Motor charging

(MD)

30 30

Mounting φ4.5 hole

PROFIBUS-DP interface unit (BIF-PR)

30 30

Mounting bracket

5

35mm IEC rail holder

IEC35mm rail

Terminal

67.5

90

M3 terminal screws

Terminal

35mm IEC rail holder

65

23.5

37.5

Terminal

P1 P2 FG

Power supply

(100-240V AC • DC)

Frame Ground

Terminal

VT unit (VT)

20~24

Height of wiring

30 30

Mounting

φ4.5 hole

30 30

Mounting bracket

5

35mm IEC rail holder

IEC35mm rail

90

35mm IEC rail holder

65

35mm IEC rail holder

30 30

Terminal Mounting

φ4.5 hole

V1 V2 V3 VN

Line voltage inputs(To AE-SW main circuit) Disconnect the voltage input wires during dielectric testing of main circuit.

Pre-cautions when making connections

Use M12 bolts, plain washers, and spring lock washers to connect the conductor. There are various size plain washers, but use 24mm or smaller outside diameter washers. The washers may overlap if too large washers are used.

It is recommended to apply silver plating on the contact surface of the conductor which is used to connect with the terminal of circuit breakers in order to prevent the increase of contact resistance due to moisture, etc. Tin plating or nickel plating may be applied, but quickly connect with the circuit breaker terminal if nickel plating is applied because nickel plating is less resistant to sulfur dioxide gas.

Clean the contact surface and securely tighten

25mm the bolts with a correct torque (M12: 40 to 50

N • m).

Plain washer

The terminal which is applicable to connect the conductor is different depending on the shape of the terminal. Refer to the outline dimensions of P.39 to P.46.

25

Conductor (plating)

ACB Terminal (silver plating) Standard tightening torque

Screw size

M12

Tightening torque(N

• m)

40~50

Plain washer

Since fault current flowing through the conductors cause large electromagnetic forces,the conductors should be secured firmly, using the values in the below table as a reference. Max distance between fixing support and ACB bus bar should be less than 200mm.

AE–SW

Bus bar

Max.200mm

Fixing support

Electromagnetic force in N per 1m conductor

(in the case of three phase short circuit)

Type

Conductor distance(mm)

Prospective fault current kA(pf)

30(0.2)

42(0.2)

50(0.2)

65(0.2)

75(0.2)

85(0.2)

100(0.2)

130(0.2)

AE630-SW~

AE1600-SW

85

-

-

-

-

7700

15100

21400

36100

AE2000-SWA

3-Pole

115

4-Pole

105

-

-

-

-

5700

11200

15800

26700

-

-

-

-

6300

12200

17300

29300

(N)

AE2000-SW~

AE3200-SW

130

AE4000-SWA

Drawout type Fixed type

3-Pole 4-Pole 3-Pole 4-Pole

190 170 152 145

AE4000-SW~

AE6300-SW

262

5100

9900

14000

23600

31500

40400

-

-

3500

6800

9600

16200

21500

27600

-

-

3900

7600

10700

18100

24100

30900

-

-

4300

8500

12000

20200

26900

34500

-

-

4500

8900

12600

21200

28200

36200

-

-

2500

5000

7000

11800

15800

20000

27800

47000

When selecting conductors to be connected to AE breakers, please ensure that they have a sufficient current capacity. Refer to the right table.

Conductor Size(IEC 60947-1; Ambient 40 °C Temp., Open air)

Connecting conductors(copper bus bar)

Rated current

Max.(A) Arrangement Quantity Conductor size(mm)

630 2 40 x 5

1000

1250

1600

2000

2500

3150(3200)*1

3

4

3

2

2

2

60 x 5

80 x 5

100 x 5

100 x 5

100 x 5

100 x 10

4000

AE4000-SWA

Drawout type

With long surface vertical

4 150 x 10

4000

AE4000-SWA

Fixed type

4000

(AE4000-SW)

5000

6300

3

4

4

4

150 x 10

100 x 10

150 x 10

200 x 10

*1 The temperature rise of rated current 3200A conforms to the requirement of IEC 60947-1 for the connecting conductor size of a rated current 3150A. In case of more than 3200A, conductor sizes are not defined in IEC 60947-1.

Insulation distance

When a short-circuit current is interrupted, discharged hot gas blows out from the exhaust port of the arc extinguishing chamber, so provide a clearance as shown in the following table.

Note1:On the fixed type, maintenance is possible with following clearance.

B

Electrical equipment,appliances or screen

B

Side plate

C

Dimensions

Type

AE630-SW~AE3200-SW

AE2000-SWA AE4000-SWA

(mm)

AE4000-SW~

AE6300-SW

Mounting surface

Applicable voltage

A

Fixed type

Drawout type

B

C

D

B

C

D

A

AC600V or less

(Note 1) 0

(Note 3)

(Note 2)

50

162

50

0

(Note 3)

(Note 2)

50

240

50

AC660V, 690V

(Note 1)

(Note 3)

(Note 2)

(Note 3)

(Note 2)

100

50

162

50

100

50

240

50

AC690V or less

(Note 1)

(Note 3)

(Note 1)

(Note 3)

200

50

200

200

50

-

-

200

Note1:300mm or more clearance is necessary to inspect the arc-extinguishing chamber and contacts.

Note2:The wiring space reguired for the control terminal block.

Note3:When using mechanical interlock, door interlock ,etc., dimension B becomes larger.

Service conditions

1. Normal service condition

Under ordinary conditions the following normal working conditions are all satisfied, the AE Series air circuit breaker may be used unless otherwise specified.

1.Ambient temperature A range of max. +40

°C to min. -5°C is recommended.

And the average over 24 hours must not exceed +35

°C.

2.Altitude

2,000m(6,600 feet) or less

3.Environmental conditions The air must be clean, and the relative humidity must be 85% or less at max. temp. +40

°C.Do not use and store in atmospheres with sulfide gas and ammonia gas etc.(H

2

S

≤ 0.01ppm, SO

2

≤ 0.1ppm, NH

3

< a few ppm.)

4.Installation conditions

5.Storage temperature

6.Guideline for replacement

When installing the AE Series air circuit breaker, refer to the installation instructions in the catalogue and instruction manual.

A range of max. +60 °C to min. -20°C is recommended to be stored.

And the average over 24 hours must not exceed +35

°C.

Within approx. 15 years.Please refer to the instruction manual.

2. Special service conditions

In case of special service condition, service life may become shorter in some cases.

1.Special environmental conditions

2.High ambient temperature

High temperature and/or high humidity

Corrosive gas

If the ambient temperature exceeds +40

°C, the uninterrupted current rating will be reduced. Since the derating value is different depending on the applicable standard, refer to P56.

3.High altitude Since the heat radiation rate is reduced for use at the 2,000m or higher, accordingly the operating voltage, continuous current capacity and breaking capacity are derated.Moreover the insulation durability is also decreased owing to the atmospheric pressure. Please inquire us for further detail.

Internal resistance, reactance and power consumption (per pole)

Type Connection

AE630-SW

AE1000-SW

AE1250-SW

AE1600-SW

AE5000-SW

AE6300-SW

Fixed type

Drawout type

Fixed type

Drawout type

Fixed type

Drawout type

Fixed type

Drawout type

AE2000-SWA

Fixed type

Drawout type

AE2000-SW

Fixed type

Drawout type

AE2500-SW

AE3200-SW

Fixed type

Drawout type

Fixed type

Drawout type

Fixed type

AE4000-SWA

Drawout type

Fixed type

AE4000-SW

Drawout type

Fixed type

Drawout type

Fixed type

Drawout type

Reactance

(m Ω)

0.063

0.095

0.047

0.071

0.047

0.071

0.048

0.072

0.048

0.072

0.038

0.062

0.038

0.062

0.038

0.062

0.059

0.089

0.060

0.091

0.060

0.091

0.063

0.095

The above values are applicable for one pole. (at brandnew product)

Internal resistance

(m Ω)

0.016

0.025

0.010

0.020

0.008

0.018

0.007

0.014

0.009

0.015

0.010

0.013

0.009

0.011

0.008

0.0085

0.028

0.042

0.026

0.040

0.024

0.038

0.016

0.030

Power consumption

(W)

50

113

72

143

64

100

40

80

144

240

160

210

225

275

318

340

38

60

41

77

11

17

26

40

Deratings by ambient temperature

Standard

Ambient Temperature

AE630-SW

AE1000-SW

AE1250-SW

AE1600-SW

AE2000-SWA

AE2000-SW

AE2500-SW

AE3200-SW

AE4000-SWA

AE4000-SW

AE5000-SW

AE6300-SW

2000

2500

3200

4000

4000

5000

6300

40 °C

630

1000

1250

1600

2000

IEC60947-2, BS, JIS C 8201-2-1 (Standard:40 °C)

LR, GL, BV, DNV, ABS, NK, CCS (Standard:45 °C)

45 °C 50 °C 55 °C

630 630 630

1000 1000 1000

1250

1600

2000

1250

1600

1900

1250

1550

1800

2000

2500

3200

4000

4000

5000

6300

2000

2500

3200

4000

4000

5000

5750

2000

2450

3000

3800

3900

5000

5500

2000

2350

2900

3600

3750

4750

5200

60 °C

630

1000

1200

1500

1700

(A)

With Extension module, Display and Network

In case extension module (EX1), display (DP1) and network are attached, the following derating values shown in this table are applied.

(A)

IEC60947-2, BS, JIS C 8201-2-1 (Standard:40

°C)

Standard

LR, GL, BV, DNV, ABS, NK, CCS (Standard:45

°C)

Ambient Temperature 40 °C 45 °C 50 °C

AE630-SW 630 630 630

AE1000-SW 1000 1000 1000

AE1250-SW

AE1600-SW

AE2000-SWA

AE2000-SW

AE2500-SW

AE3200-SW

AE4000-SWA

1250

1600

2000

2000

2500

3200

4000

1250

1600

1900

2000

2500

3200

3800

1250

1440

1700

2000

2500

2880

3600

The above table shows the maximum rated current per each ambient temperature for drawout type breaker with vertical connection

(at brandnew product), when breaker and bus bar are installed in open air.

Connection bus bar is according to IEC60947-1. For AE3200-SW, AE4000-SWA, AE4000-SW, AE5000-SW and AE6300-SW, it is required to follow the manufacturer recommended size shown in Page 53.

As for ambient temperature exceeding 60 °C, please inquire us.

Discrimination table

AE-SW Series air circuit breakers provide easy selective co-ordination with branch circuit breakers.

For selective co-crdinations,refer to the following table.

AC230V sym kA

MB

NV

|

S

NF

|

C

NV

|

C

NF

|

S

H

Main circuit

U n

Branch ti b r e a k i n g circuit breaker breaker c a p a c ti y

H

NF

|

U

NF400-HEW

NV400-HEW

NF400-REW

NV400-REW

NF630-SW

NV630-SW

NF630-SEW

NV630-SEW

NF630-HEW

NV630-HEW

NF630-REW

NF800-SEW

NV800-SEW

NF800-HEW

NV800-HEW

NF800-REW

NF63-CW

NV63-CW

NF125-CW

NV125-CW

NF250-CW

NV250-CW

NF400-CW

NV400-CW

NF32-SW

MB30-SW

MB50-CW

NV32-SW

NF63-SW

MB50-SW

NV63-SW

NF63-HW

NV63-HW

NF125-SW

MB100-SW

NV125-SW

NF125-HW

NV125-HW

NF250-SW

MB225-SW

NV250-SW

NV250-SEW

NF250-HW

NV250-HW

NF400-SW

NV400-SW

NF400-SEW

NV400-SEW

NF630-CW

NV630-CW

NF800-CEW

NF125-RGW

NF125-UGW

NF250-RGW

NF250-UGW

NF400-UEW

NF800-UEW

7.5

10

15

25

50

100

50

100

85

85

100

150

85

85

100

150

85

100

150

7.5

30

35

50

50

50

125

200

125

200

200

200

AE630-SW

65

7.5

9(10)

9(10)

9(25)

9(50)

9(65)

9(50)

9(65)

-

9(65)

9(65)

9(65)

-

-

-

-

-

-

-

7.5

9(30)

9(35)

-

-

-

65

65

9(65)

9(65)

9(65)

-

AE1000-SW AE1250-SW AE1600-SW AE2000-SWA AE2000-SW AE2500-SW

65

7.5

10

10

25

45(50)

50(65)

20(50)

25(65)

-

15(65)

15(65)

15(65)

-

15(65)

15(65)

15(65)

-

-

-

7.5

15(30)

15(35)

15(50)

-

-

65

65

65

65

15(65)

-

65

7.5

10

10

25

50

65

22(50)

40(65)

20(65)

20(65)

20(65)

20(65)

-

18(65)

18(65)

18(65)

18(65)

18(65)

18(65)

7.5

18(30)

18(35)

18(50)

-

-

65

65

65

65

18(65)

18(65)

65

7.5

10

10

25

50

65

42(50)

65

27(65)

27(65)

27(65)

27(65)

24(65)

24(65)

24(65)

24(65)

24(65)

24(65)

24(65)

7.5

24(30)

24(35)

24(50)

24(50)

24(50)

65

65

65

65

29(65)

24(65)

65

7.5

10

10

25

50

65

42(50)

65

27(65)

27(65)

27(65)

27(65)

24(65)

24(65)

24(65)

24(65)

24(65)

24(65)

24(65)

7.5

24(30)

24(35)

24(50)

24(50)

24(50)

65

65

65

65

29(65)

24(65)

85

7.5

10

10

25

50

85

50

85

42(75)

42(75)

42(75)

42(75)

30(75)

30(75)

30(75)

30(75)

30(75)

30(75)

30(75)

7.5

30

35

30(50)

30(50)

30(50)

85

85

85

85

48(75)

30(75)

AE-SW

85

7.5

10

10

25

50

85

50

85

70(75)

70(75)

70(75)

70(75)

40(75)

40(75)

40(75)

40(75)

40(75)

40(75)

40(75)

7.5

30

35

37(50)

37(50)

37(50)

85

85

85

85

85

37(75)

AE3200-SW AE4000-SWA AE4000-SW AE5000-SW AE6300-SW

85

7.5

10

10

25

50

85

50

85

85

85

85

85

60(75)

60(75)

60(75)

60(75)

60(75)

60(75)

60(75)

7.5

30

35

48(50)

48(50)

48(50)

85

85

85

85

85

68(75)

85

7.5

10

10

25

50

85

50

85

85

85

85

85

60(75)

60(75)

60(75)

60(75)

60(75)

60(75)

60(75)

7.5

30

35

48(50)

48(50)

48(50)

85

85

85

85

85

68(75)

130

7.5

10

10

25

50

100

50

100

85

85

100

130

85

85

85(100)

85(100)

85

85(100)

85(100)

7.5

30

35

50

50

50

125

130

125

130

130

85(100)

130

7.5

10

10

25

50

100

50

100

85

85

100

130

85

85

85(100)

85(100)

85

85(100)

85(100)

7.5

30

35

50

50

130

130

85(100)

• The values in the table represent the max.rated current for both Series AE-SW air circuit breakers and branch breakers,and the selective co-ordination applies when the AE-SW series air circuit breakers instantaneous pick up is set to maximum.

• The numerals shown in parentheses are for AE-SW with MCR.(When set MCR).

50

125

130

125

130

7.5

10

10

25

50

100

50

100

85

85

100

130

85

85

85(100)

85(100)

85

85(100)

85(100)

7.5

30

35

50

50

50

125

130

125

130

130

85(100)

AC440V sym kA

NF

|

S

NF

|

C

NV

|

C

H

MB

NV

|

S

H

Main circuit

U n

Branch ti b r e a k i n g circuit breaker breaker c a p a c ti y

NF

|

U

NF400-HEW

NV400-HEW

NF400-REW

NV400-REW

NF630-SW

NV630-SW

NF630-SEW

NV630-SEW

NF630-HEW

NV630-HEW

NF630-REW

NF800-SEW

NV800-SEW

NF800-HEW

NV800-HEW

NF800-REW

NF63-CW

NV63-CW

NF125-CW

NV125-CW

NF250-CW

NV250-CW

NF400-CW

NV400-CW

NF32-SW

MB30-SW

MB50-CW

NV32-SW

NF63-SW

MB50-SW

NV63-SW

NF63-HW

NV63-HW

NF125-SW

MB100-SW

NV125-SW

NF125-HW

NV125-HW

NF250-SW

MB225-SW

NV250-SW

NV250-SEW

NF250-HW

NV250-HW

NF400-SW

NV400-SW

NF400-SEW

NV400-SEW

NF630-CW

NV630-CW

NF800-CEW

NF125-RGW

NF125-UGW

NF250-RGW

NF250-UGW

NF400-UEW

NF800-UEW

2.5

5

7.5

10

25

50

25

50

42

42

65

125

42

42

65

125

42

65

125

2.5

10

15

25

36

36

125

200

125

200

200

200

AE630-SW

65

2.5

5

7.5

9(10)

7(25)

9(50)

7(25)

7(50)

-

9(42)

9(65)

9(65)

-

-

-

-

-

-

-

2.5

9(10)

9(15)

-

-

-

35(65)

50(65)

9(65)

9(65)

9(65)

-

AE1000-SW

65

2.5

5

7.5

10

20(25)

30(50)

14(25)

15(50)

-

15(42)

15(65)

15(65)

-

15(42)

15(65)

15(65)

-

-

-

2.5

10

15

15(25)

-

-

65

65

50(65)

65

15(65)

-

AE1250-SW

65

2.5

5

7.5

10

25

50

19(25)

25(50)

18(42)

18(42)

18(65)

18(65)

-

18(42)

18(65)

18(65)

18(42)

18(65)

18(65)

2.5

10

15

18(25)

-

-

65

65

65

65

18(65)

18(65)

AE1600-SW

65

2.5

5

7.5

10

25

50

25

42(50)

24(42)

24(42)

24(65)

24(65)

24(42)

24(42)

24(65)

24(65)

24(42)

24(65)

24(65)

2.5

10

15

24(25)

24(36)

24(36)

65

65

65

65

29(65)

24(65)

AE2000-SWA

65

2.5

5

7.5

10

25

50

25

42(50)

24(42)

24(42)

24(65)

24(65)

24(42)

24(42)

24(65)

24(65)

24(42)

24(65)

24(65)

2.5

10

15

24(25)

24(36)

24(36)

65

65

65

65

29(65)

24(65)

AE-SW

AE2000-SW

85

2.5

5

7.5

10

25

50

25

50

33(42)

33(42)

33(65)

33(75)

33(42)

30(42)

30(65)

30(75)

30(42)

30(65)

30(75)

2.5

10

15

25

30(36)

30(36)

85

85

85

85

48(75)

30(75)

AE2500-SW

85

2.5

5

7.5

10

25

50

25

50

42

42

45(65)

45(75)

42

40(42)

40(65)

40(75)

40(42)

40(65)

40(75)

2.5

10

15

25

36

36

85

85

85

85

85

37(75)

AE3200-SW AE4000-SWA

85

2.5

5

7.5

10

25

50

25

50

42

42

65

80

42

42

60(65)

60(75)

42

60(65)

60(75)

2.5

10

15

25

36

36

85

85

85

85

85

68(75)

85

2.5

5

7.5

10

25

50

25

50

42

42

65

80

42

42

60(65)

60(75)

42

60(65)

60(75)

2.5

10

15

25

36

36

85

85

85

85

85

68(75)

AE4000-SW

130

2.5

5

7.5

10

25

50

25

50

42

42

65

100

42

42

65

75(100)

42

65

75(100)

2.5

10

15

25

36

36

125

130

125

130

130

85(100)

AE5000-SW

130

2.5

5

7.5

10

25

50

25

50

42

42

65

100

42

42

65

75(100)

42

65

75(100)

2.5

10

15

25

36

36

125

130

125

130

130

85(100)

• The values in the table represent the max.rated current for both Series AE-SW air circuit breakers and branch breakers,and the selective co-ordination applies when the AE-SW series air circuit breakers instantaneous pick up is set to maximum.

• The numerals shown in parentheses are for AE-SW with MCR.(When set MCR).

AE6300-SW

130

2.5

5

7.5

10

25

50

25

50

42

42

65

100

42

42

65

75(100)

42

65

75(100)

2.5

10

15

25

36

36

125

130

125

130

130

85(100)

Ordering information for Mitsubishi AE-SW series air circuit breaker(General use....WS Type, Special use....WB Type)

Number of units units Customer(name) Order No.

Type

P9~10

AE -SW

Number of poles 3P

AE630-SW~

AE4000-SWA

4P

Connection

Main circuit terminal

P.11

Fixed type

Note3

Horizontal terminal(FIX)

(AE630~1600-SW / AE2000~3200-SW)

(

Vertical terminal(FIX-VT)

AE2000-SWA / AE4000-SWA

AE4000~6300-SW

)

AE -SWA

AE4000-SW~

AE6300-SW

3P 4P HN

4P FN

Note15

Note15

Current setting Ir A CT rating

Applicable standard

Ambient temperature

Reset type

IEC 60947-2

40

°C(Standard)

Automatic Reset (Standard)

A

Note1 P9,P20

CCC

Others

°C

Note2

Manual Reset (MRE)

Drawout type

Note3

Horizontal terminals(DR)(standard)

Vertical terminals(DR-VT)

AE2000-SWA / AE4000-SWA

AE4000~6300-SW

Front terminals(DR-FT)

Note4

Drawout type accessories

P17~18

Cell switch(CL- : 1 or 2 or 3 or 4) Note5

Shorting b-contact(SBC- : 1 or 2 or 3 or 4 or 5)

Lifting hooks(HP)

Safety shutter(SST)

Shutter lock(SST-LOCK)

Mis-insertion preventor(MIP)

Test jumper(TJ)

Vertical terminal adapter(VTA)

Front terminal adapter(FTA)

Can be connected to the

Horizontal terminals.

Electronic trip relay(ETR)

With ETR

Type

Main setting module

AE630–1600-SW,

WS1, WB1 AE2000–3200-SW,

AE4000-SW

AE2000-SWA,

G1: Ground fault protection

Note6

Note7

N5: Neutral pole 50% protection

● Power supply Optional setting module

EXAMPLE

AP: 2nd Additional Pre-alarm

NA: Without optional setting

P1: AC • DC100-240V

P2: DC24-60V

P3: AC100-240V / DC100-125V with output contact

P4: DC24-60V with output contact

Additional function

P5: DC100-240V with output contact (SSR)

Display(DP1)

VT unit(VT)

P32

Extension module(EX1)

Display onto panel board(DP2)

Network

P33

BIF-CC

BIF-PR

BIF-MD

BIF-CON

BIF-CL

Wire system (when EX1 is specified)

WS2, WB2 AE4000-SWA,

AE5000-SW

WS3, WB3 AE6300-SW

Note8 WS : General use

WB : INST/MCR only

Neutral CT(NCT)

External ZCT Note9

3

φ3W

3

φ4W

P28 ZCT EX1

Normal connection : Note13

Inverse connection :

Note14

ZT B

ZTA

BARE(ETR not required)

Electrical accessories

P12~14

Mechanical accessories

P15~16

Auxiliary switch

A and B contacts in the same quantity are used.

Max. quantity: 5 each for A and B contacts

Standard(AX : 2 or 4 or 6 or 8 or 10)

High capacity(HAX : 2 or 4 or 6 or 8 or 10)

Motor charging(MD) AC

DC100–125V

AC • DC200–250V

DC24V

Note10

DC48V

Closing coil(CC) AC

DC100–250V

DC24–48V

Shunt trip device

(SHT)

AC • DC100–250V

AC380–500V

DC24–48V

Under voltage trip device(UVT)

AC100–120V

Time delay AC200–240V

AC380–460V

DC24V

Inst(INST)

0.5s(05)

3.0s(30) DC48V

DC100–110V

DC120–125V

Note:In case of 380-460V AC, the external transformer is attached

Push button cover(BC-L)

Counter(CNT)

Cylinder lock(CYL)

Door interlock(DI)

Note11

Terminal cover(TTC)

Door frame(DF)

Dust cover(DUC)

Interphase barrier(BA) Note12

Mechanical interlock(MI) for 2units(MI2) for 3units(MI3)

Note11

P16

Condenser trip device

(COT)

AC100–110V

AC200–220V

N o t e 1 : In case of AE630-SW and AE2000-SW Low rating type, please specify CT rating.

Refer to Page 9 and Page 20.

N o t e 2 : There is a case to be derated by ambient temperature. Refer to Page 54.

N o t e 3 : As for the terminal for AE2000-SWA, AE4000-SWA and AE4000-SW~AE6300-SW,

Vertical terminal type only is available. (FIX-VT or DR-VT)

N o t e 4 : Refer to Page 11 and Page 39~46.

N o t e 5 : This setting is available for change by customer later. A preliminary setting of CL at factory shipment is as follows.

CL1: 1C CL2: 1C1D CL3: 1C1T1D CL4: 2C1T1D

N o t e 6 : Not available for AE630-SW with CT rating : 250A or 315A or 500A.

N o t e 7 : Not available for WB1, WB2 and WB3 Main setting module.

N5 optional setting module is used for 3phase 4wires system.(4Pole breaker or 3pole breaker with Neutral CT)

N o t e 8 : Neutral CT is required for Ground fault or Neutral pole protection, when 3 Pole breaker is used for 3 phase 4 wires system.

N o t e 9 : In case of Earth leakage protection, it is required External ZCT.

Note10: DC24V and DC48V are not available for AE4000-SWA 4P and AE4000-SW~AE6300-SW.

Note11: The combined installation of DI and MI3 is not available.

Note12: Some module types are not provided BA. Refer to Page15.

Note13: Supply connect to the top terminals.

Note14: Supply connect to the bottom terminals.

Note15: Current capacity of the neutral poles

HN: 50% of the rated current

FN: 100% of the rated current (See page 43, 48 for the outline and dimensions.)

Remark

Order Issuer

Ordering information for Mitsubishi AE-SW series air circuit breaker(General use....WS Type, Special use....WB Type)

Number of units units Customer(name) Order No.

Type

P.9~10

AE -SW

Number of poles 3P

AE630-SW~

AE4000-SWA

4P

Connection

Main circuit terminal

P.11

Fixed type

Note3

Horizontal terminal(FIX)

(AE630~1600-SW / AE2000~3200-SW)

(

Vertical terminal(FIX-VT)

AE2000-SWA / AE4000-SWA )

AE4000~6300-SW

AE -SWA

AE4000-SW~

AE6300-SW

3P 4P HN

4P FN

Note15

Note15

Current setting Ir A CT rating

Applicable standard

Ambient temperature

Reset type

IEC 60947-2

40

°C(Standard)

Automatic Reset (Standard)

A

Note1 P.9,P.20

CCC

Others

°C

Note2

Manual Reset (MRE)

Drawout type

Note3

Horizontal terminals(DR)(standard)

Vertical terminals(DR-VT)

AE2000-SWA / AE4000-SWA

AE4000~6300-SW

Front terminals(DR-FT)

Note4

Drawout type accessories

P.17~18

Cell switch(CL- : 1 or 2 or 3 or 4) Note5

Shorting b-contact(SBC- : 1 or 2 or 3 or 4 or 5)

Lifting hooks(HP)

Safety shutter(SST)

Shutter lock(SST-LOCK)

Mis-insertion preventor(MIP)

Test jumper(TJ)

Vertical terminal adapter(VTA)

Front terminal adapter(FTA)

Can be connected to the

Horizontal terminals.

Electronic trip relay(ETR)

With ETR

Type

● Main setting module

AE630–1600-SW,

WS1, WB1 AE2000–3200-SW,

AE4000-SW

AE2000-SWA,

WS2, WB2 AE4000-SWA,

AE5000-SW

WS3, WB3 AE6300-SW

● Optional setting module

G1: Ground fault protection

Note6

Note7

N5: Neutral pole 50% protection

E1: Earth leakage protection

AP: 2nd Additional Pre-alarm

NA: Without optional setting

● Power supply

P1: AC•DC100-240V

P2: DC24-60V

P3: AC100-240V / DC100-125V with output contact

P4: DC24-60V with output contact

Additional function

P.32

Extension module(EX1)

Display(DP1)

Display onto panel board(DP2)

VT unit(VT)

Network

P.33

BIF-CC

BIF-PR

BIF-MD

Temperature alarm(TAL)

MCR switch(MCR-SW)

BIF-CON

BIF-CL

Wire system (when EX1 is specified)

WS : General use

WB : INST/MCR only

BARE(ETR not required)

P.28

Neutral CT(NCT) Note8

External ZCT Note9

ZCT

ZT B

ZTA

EX1

3

φ3W

3

φ4W

Normal connection : Note13

Inverse connection :

Note14

Electrical accessories

P.12~14

Mechanical accessories

P.15~16

Auxiliary switch

A and B contacts in the same quantity are used.

Max. quantity: 5 each for A and B contacts

Standard(AX : 2 or 4 or 6 or 8 or 10)

High capacity(HAX : 2 or 4 or 6 or 8 or 10)

Motor charging(MD) AC • DC100–125V

AC • DC200–250V

DC24V

Note10

DC48V

Closing coil(CC) AC • DC100–250V

DC24–48V

Shunt trip device

(SHT)

AC • DC100–250V

AC380–500V

DC24–48V

Under voltage trip device(UVT)

AC100–120V

Time delay AC200–240V

AC380–460V

DC24V

Inst(INST)

0.5s(05)

3.0s(30) DC48V

DC100–110V

DC120–125V

Note:In case of 380-460V AC, the external transformer is attached

Push button cover(BC-L)

Counter(CNT)

Cylinder lock(CYL)

Door interlock(DI)

Note11

Terminal cover(TTC)

Door frame(DF)

Dust cover(DUC)

Interphase barrier(BA) Note12

Mechanical interlock(MI) for 2units(MI2) for 3units(MI3)

Note11

P.16

Condenser trip device

(COT)

AC100–110V

AC200–220V

N o t e 1 : In case of AE630-SW and AE2000-SW Low rating type, please specify CT rating.

Refer to Page 9 and Page 20.

N o t e 2 : There is a case to be derated by ambient temperature. Refer to Page 54.

N o t e 3 : As for the terminal for AE2000-SWA, AE4000-SWA and AE4000-SW~AE6300-SW,

Vertical terminal type only is available. (FIX-VT or DR-VT)

N o t e 4 : Refer to Page 11 and Page 39~46.

N o t e 5 : This setting is available for change by customer later. A preliminary setting of CL at factory shipment is as follows.

CL1: 1C CL2: 1C1D CL3: 1C1T1D CL4: 2C1T1D

N o t e 6 : Not available for AE630-SW with CT rating : 250A or 315A or 500A.

N o t e 7 : Not available for WB1, WB2 and WB3 Main setting module.

N5 optional setting module is used for 3phase 4wires system.(4Pole breaker or 3pole breaker with Neutral CT)

N o t e 8 : Neutral CT is required for Ground fault or Neutral pole protection, when 3 Pole breaker is used for 3 phase 4 wires system.

N o t e 9 : In case of Earth leakage protection, it is required External ZCT.

Note10: DC24V and DC48V are not available for AE4000-SWA 4P and AE4000-SW~AE6300-SW.

Note11: The combined installation of DI and MI3 is not available.

Note12: Some module types are not provided BA. Refer to Page15.

Note13: Supply connect to the top terminals.

Note14: Supply connect to the bottom terminals.

Note15: Current capacity of the neutral poles

HN: 50% of the rated current

FN: 100% of the rated current (See page 43, 48 for the outline and dimensions.)

Remark

Order Issuer

Ordering information for Mitsubishi AE-SW series air circuit breaker(Generator protection use....WM Type)

Number of units units Customer(name) Order No.

Type

P.9~10

AE -SW

Number of poles 3P

AE630-SW~

AE4000-SWA

4P

Connection

Main circuit terminal

P.11

Fixed type

Note3

Horizontal terminal(FIX)

(AE630~1600-SW / AE2000~3200-SW)

(

Vertical terminal(FIX-VT)

AE2000-SWA / AE4000-SWA

AE4000~6300-SW

)

AE -SWA

AE4000-SW~

AE6300-SW

3P 4P HN

4P FN

Note15

Note15

Current setting Ir A

Applicable standard

Ambient temperature

Reset type

LR

40

GL BV

°C(Standard)

Automatic Reset (Standard)

DNV ABS CCS IEC 60947-2

Others

°C

Note2

Manual Reset (MRE)

Drawout type

Note3

Horizontal terminals(DR)(standard)

Vertical terminals(DR-VT)

AE2000-SWA / AE4000-SWA

AE4000~6300-SW

Front terminals(DR-FT)

Note4

Drawout type accessories

P.17~18

Cell switch(CL- : 1 or 2 or 3 or 4) Note5

Shorting b-contact(SBC- : 1 or 2 or 3 or 4 or 5)

Lifting hooks(HP)

Safety shutter(SST)

Shutter lock(SST-LOCK)

Mis-insertion preventor(MIP)

Test jumper(TJ)

Vertical terminal adapter(VTA)

Front terminal adapter(FTA)

Can be connected to the

Horizontal terminals.

Electronic trip relay(ETR)

With ETR

Type

Main setting module

AE630–1600-SW,

WM1 AE2000–3200-SW,

AE4000-SW

AE2000-SWA,

WM2 AE4000-SWA,

AE5000-SW

WM3 AE6300-SW

WM : Generator protection use

Specify a setting value,if required.

P.23,24,27~29

LTD pick-up current : I L

LTD time: T L

STD pick-up current : I sd

STD time: T sd

INST pick-up current:I i

Pre-alarm current:I p

Othters ( )

Optional setting module

G1: Ground fault protection

Note6

Note7

N5: Neutral pole 50% protection

E1: Earth leakage protection

AP: 2nd Additional Pre-alarm

NA: Without optional setting

Power supply

P1: AC • DC100-240V

P2: DC24-60V

Additional function

P.32

Extension module(EX1)

Display(DP1)

Display onto panel board(DP2)

VT unit(VT)

Network

P.33

BIF-CC

BIF-PR

BIF-MD

BIF-CON

BIF-CL

P3: AC100-240V / DC100-125V with output contact

P4: DC24-60V with output contact

Temperature alarm(TAL)

MCR switch(MCR-SW)

P5: DC100-240V with output contact (SSR)

Neutral CT(NCT) Note8

External ZCT Note9

P.28

ZCT

ZT B

ZTA

Wire system (when EX1 is specified)

EX1

3

φ3W

3

φ4W

Normal connection : Note13

Inverse connection : Note14

Electrical accessories

P.12~14

Mechanical accessories

P.15~16

Auxiliary switch

A and B contacts in the same quantity are used.

Max. quantity: 5 each for A and B contacts

Standard(AX : 2 or 4 or 6 or 8 or 10)

High capacity(HAX : 2 or 4 or 6 or 8 or 10)

Motor charging(MD) AC

DC100–125V

AC

DC200–250V

DC24V

DC48V

Note10

Closing coil(CC)

Shunt trip device

(SHT)

AC • DC100–250V

DC24–48V

AC

DC100–250V

AC380–500V

DC24–48V

Under voltage trip device(UVT)

AC100–120V

AC200–240V

AC380–460V

DC24V

DC48V

Time delay

Inst(INST)

0.5s(05)

3.0s(30)

DC100–110V

DC120–125V

Note:In case of 380-460V AC, the external transformer is attached

Push button cover(BC-L)

Counter(CNT)

Cylinder lock(CYL)

Door interlock(DI)

Note11

Terminal cover(TTC)

Door frame(DF)

Dust cover(DUC)

Interphase barrier(BA) Note12

Mechanical interlock(MI) for 2units(MI2) for 3units(MI3)

Note11

P.16

Condenser trip device

(COT)

AC100–110V

AC200–220V

N o t e 1 : Please specify current setting (Ir) from the specification table.

Refer to Page 9 and 10.

N o t e 2 : There is a case to be derated by ambient temperature. Refer to Page 54.

N o t e 3 : As for the terminal for AE2000-SWA, AE4000-SWA and AE4000-SW~AE6300-SW,

Vertical terminal type only is available. (FIX-VT or DR-VT)

N o t e 4 : Refer to Page 11 and Page 39~46.

N o t e 5 : This setting is available for change by customer later. A preliminary setting of CL at factory shipment is as follows.

CL1: 1C CL2: 1C1D CL3: 1C1T1D CL4: 2C1T1D

N o t e 6 : Not available for AE630-SW with CT rating : 250A or 315A or 500A.

N o t e 7 : N5 optional setting module is used for 3 phase 4 wires system.(4 Pole breaker or 3 pole breaker with Neutral CT)

N o t e 8 : Neutral CT is required for Ground fault or Neutral pole protection, when 3 Pole breaker is used for 3 phase 4 wires system.

N o t e 9 : In case of Earth leakage protection, it is required External ZCT.

Note10: DC24V and DC48V are not available for AE4000-SWA 4P and AE4000-SW~AE6300-SW.

Note11: The combined installation of DI and MI3 is not available.

Note12: Some module types are not provided BA. Refer to Page15.

Note13: Supply connect to the top terminals.

Note14: Supply connect to the bottom terminals.

Note15: Current capacity of the neutral poles

HN: 50% of the rated current

FN: 100% of the rated current (See page 43, 48 for the outline and dimensions.)

Remark

Order Issuer

Country / Region

Australia

Belgium

Chile

China

Colombia

Czech Republic

Denmark

Egypt

France

Germany

Greece

Hungary

Hong Kong

Indonesia

Ireland

Israel

Italy

Kazakhstan

Korea

Laos

Lebanon

Lithuania

Malaysia

Taiwan

Thailand

The Netherlands

Turkey

United Kingdom

Uruguay

Venezuela

Vetnam

Mitsubishi Electric Australia Pty. Ltd.

Koning & Hartman B.V.

Rhona S.A.

Company

Mitsubishi Electric Automation (Shanghai)

Limited

Proelectrico Representaciones S.A.

Autocont Control Systems S.R.O.

Lemvigh-Mueller

Cairo Electrical Group

Mitsubishi Electric Europe B.V.

Mitsubishi Electric Europe B.V.

Elektrapothiki Attikis S.A.

Meltrade Ltd.

Mitsubishi Electric Automation (Hong Kong)

Limited

P.T.Sahabat Indonesia

Mitsubishi Electric Europe B.V.

Gino Industries Ltd.

Mitsubishi Electric Europe B.V.

Kazpromautomatics Ltd.

Mitsubishi Electric Automation Korea Co., Ltd

Societe Lao Import Co., Ltd.

Comptoir d'Electricite Generale-Liban

Rifas UAB

Mittric Sdn Bhd

Myanmer Peace Myanmar Electric Co.,Ltd.

Middle East Arab Countries

& Cyprus

Comptoir d'Electricite Generale-International-

S.A.L.

Nepal Watt&Volt House

New Zealand

North America

Norway

Pakistan

Philippines

Poland

Republic of Moldova

Romania

Russia

Saudi Arabia

Serbia

Singapore

Slovenia

Slovakia

South Africa

Spain

Sweden

Switzerland

Black Diamond Technologies Ltd.

Mitsubishi Electric Automation USA, Inc.

Scanelec AS

Prince Electric Co.

Edison Electric Integrated, Inc.

MPL Technology Sp. z O.O.

Intehsis SRL

Sirius Trading & Services SRL

Consys

Center of Electrical Goods

Craft Consulting & Engineering D.O.O.

Mitsubishi Electric Asia Pte. Ltd.

Inea D.O.O.

CS Mtrade Slovensko, S.R.O.

CBI-electric: low voltage

Mitsubishi Electric Europe B.V.

Euro Energy Components AB

TriElec AG

Setsuyo Enterprise Co., Ltd

United Trading & Import Co., Ltd.

Imtech Marine & Offshore B.V.

GTS

Mitsubishi Electric Europe B.V.

Fierro Vignoli S.A.

Adesco S.A.

CTY TNHH-TM SA GIANG

Address

348 Victoria Road, Rydalmere, N.S.W. 2116, Australia

Woluwelaan 31, BE-1800 Vilvoorde, Belgium

Vte. Agua Santa 4211 Casilla 30-D (P.O. Box) Vina del Mar,

Chile

(Shanghai) 3F, Block 5, 103,

Cao Bao Road, Shanghai, China

Telephone

+ 61-2-9684-7777

+ 32-(0)2-2570240

+ 56-32-2-320-600

+ 86-(0)21-6475-3228

Cra 53 No 29C-73 U.I.C. - Medellin,

Colombia

+ 57-4-235-00-28

Jelinkova 59/3, CZ-72100 Ostrava Svinov, Czech Republic

+ 420-(0)59-5691-150

Geminivej 32, DK-2670 Greve, Denmark

9, Rostoum St. Garden City

+ 45-(0)43-959505

P.O. Box 165-11516 Maglis

El-Shaab, Cairo - Egypt

+ 20-2-7961337

25, Boulevard des Bouvets, F-92741 Nanterre Cedex, France + 33-(0)1-55 68 55 68

Gothaer Strasse 8, D-40880 Ratingen, Germany + 49-(0)2102-486-0

15, Agiou Orous GR-10447 Athens, Greece

Fertö utca 14. HU-1107 Budapest, Hungary

10/F Manulife Tower 169 Electric Road North

Point, Hong Kong

P.O.Box 5045 Kawasan Industri Pergudangan,

Jakarta, Indonesia

+ 30-(0)210-341-6650

+ 36-(0)1-431-9726

+ 852-28878870

+ 62-(0)21-6610651-9

Westgate Business Park, Ballymount, IRL-Dublin 24, Ireland

26, Ophir Street IL-32235 Haifa, Israel

Viale Colleoni 7, I-20041 Agrate Brianza (MI), Italy

2, Scladskaya str. KAZ-470046 Karaganda, Kazakhstan

1480-6, Gayang-Dong, Gangseo-Gu, Seoul, Korea

43-47 Lane Xang Road P.O BOX 2789 VT

Vientiane Laos

Cebaco Center - Block A Autostrade Dora,

P.O. Box 11-2597 Beirut - Lebanon

+ 353-(0)1-4198800

+ 972-(0)4-867 06 56

+ 39-(0)39-60-53 1

+ 7-3212-50 11 50

+ 82-2-3660-9572

+ 856-21-215043

+ 961-1-240445

+ 370 (0)45 / 582 728 Tinklu 29A, LT-5300 Panevezys, Lithuania

No. 5 Jalan Pemberita U1/49, Temasya Industrial Park,

Glenmarie 40150 Shah Alam, Selangor, Malaysia

NO137/139 Botataung Pagoda Road,

Botataung Town Ship 11161,Yangon, Myanmar

Cebaco Center - Block A Autostrade Dora

P.O. Box 11-1314 Beirut - Lebanon

KHA 2-65,Volt House Dillibazar Post Box:2108,

Kathmandu,Nepal

+ 603-5569-3748

+ 95-(0)1-202589

+ 961-1-240430

+ 977-1-4411330

+ 64-4-560-9100

+ 847-478-2100

+ 47-(0)55-50 60 00

+ 92-(0)42-7654342

1 Parliament Street, Lower Hutt, New Zealand

500 Corporate Woods Parkway, Vernon Hills, IL 60061 USA

Leirvikasen 43B, NO-5179 Godvik, Norway

1&16 Brandreth Road, Lahore-54000,Pakistan

24th Fl. Galleria Corporate Center, Edsa Cr. Ortigas Ave.,

Quezon City Metro Manila, Philippines

Ul. Krakowska 50, PL-32-083 Balice, Poland bld. Traian 23/1, MD-2060 Kishinev, Moldova

Str. Biharia nr. 67-77, RO-013981 Bucuresti 1, Romania

Promyshlennaya st. 42, RU-198099 St. Petersburg, Russia

Al-Shuwayer St. Side way of Salahuddin Al-Ayoubi

St. P.O. Box 15955 Riyadh 11454 - Saudi Arabia

Toplicina str.4 lok 6, SER-1800 Nis, Serbia

307 Alexandra Road #05-01/02 Mitsubishi

Electric Building Singapore 159943

+ 63-(0)2-634-8691

+ 48-(0)12-630 47 00

+ 373 (0)22 / 66 4242

+ 40 (0)21 / 201 1147

+ 7-812-325 36 53

+ 966-1-4770149

+ 381 (0)18 / 292-24-4 / 5, 523 962

+ 65-6473-2308

+ 386-(0)1-513 8100

+ 421 (0)33 / 7742 760

+ 27-(0)11-9282000

Stegne 11, SI-1000 Ljubljana, Slovenia

Vajanskeho 58, SK-92101 Piestany, Slovakia

Private Bag 2016, ZA-1600 Isando Gauteng, South Africa

Carretera de Rubí 76-80, E-08190 Sant Cugat del Vallés

(Barcelona), Spain

Järnvägsgatan 36, S-434 24 Kungsbacka, Sweden

Muehlentalstrasse 136, CH-8201 Schaffhausen,

Switzerland

6th Fl., No.105, Wu Kung 3rd, Wu-Ku Hsiang,

Taipei, Taiwan, R.O.C.

77/12 Bamrungmuang Road,

Klong Mahanak Pomprab Bangkok Thailand

Sluisjesdijk 155, NL-3087 AG Rotterdam, Netherlands

Darulaceze Cad. No. 43/A KAT. 2, TR-34384

Okmeydani-Istanbul, Turkey

Travellers Lane, UK-Hatfield, Herts. AL10 8XB,

United Kingdom

Avda. Uruguay 1274, 11.100 Montevideo, Uruguay

Calle 7 La Urbina Edificio Los Robles Locales C y D

Planta Baja, Caracas - Venezuela

47-49 Hoang Sa, St., Dakao Ward, Dist 1, Ho Chi Minh City,

Viet Nam

+ 34-(0)93-565 3131

+ 46-(0)300-69 00 40

+ 41 (0)52 / 6258425

+ 886-(0)2-2298-8889

+ 66-223-4220-3

+ 31-(0)10-487 19 11

+ 90-(0)212-320 1640

+ 44-(0)1707-27 61 00

+ 598-2-902-0808

+ 58-212-241-9952

+ 84-8-9103633

Y-0622E 0706 (MDOC)

Safety Tips :

Be sure to read the instruction manual fully before using this product.

HEAD OFFICE: TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN.

Revised publication, effective June 2007.

Specifications subject to change without notice.

This pamphlet is made from recycled paper.

advertisement

Related manuals

Download PDF

advertisement