INSTALLATION REQUIREMENTS. Maytag JXD7036YS, UXD86DYS, UXD8636DYS, LI3ZVB, JXD7030Y Series, W10342490C, 30" RETRACTABLE DOWNDRAFT VENT SYSTEM, JXD7036Y Series


Add to My manuals
36 Pages

advertisement

INSTALLATION REQUIREMENTS. Maytag JXD7036YS, UXD86DYS, UXD8636DYS, LI3ZVB, JXD7030Y Series, W10342490C, 30

4

INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Read and follow the instructions provided with any tools listed here.

Tools Needed

Jigsaw or keyhole saw

Drill

¹⁄₈" (3 mm) drill bit for pilot holes

Pencil

Tape measure or ruler

Flat-blade screwdriver

Phillips screwdriver

³⁄₈" (9.5 mm) nut driver

Level

Pliers

Metal snips

Wire stripper or utility knife

Caulking gun and weatherproof caulking compound

Parts Supplied

Top trim - stainless

End caps (2)

Lower support legs (2)

Undercounter mounting brackets (2)

4 x 8 mm screws (16)

3.5 x 9.5 mm screws (3)

3

¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular damper

4

³⁄₄" (12.0 cm) motor box

¼" (6.4 mm) deep cover

Flat vent cover plate

6" (15.2 cm) diameter vent transition with damper

Parts Needed

UL listed or CSA approved ½" (12.7 mm) conduit connector

Wall or roof cap with damper to match vent system

Vent system

Home power supply cable

UL listed wire connectors (3)

Vent clamps/duct tape as required

Location Requirements

NOTE: Downdraft vent is installed directly behind the cooktop.

Install the downdraft vent first, then install the cooktop.

IMPORTANT: Observe all governing codes and ordinances.

Have a qualified technician install the downdraft vent. It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the terminal box cover.

Downdraft vent location should be away from strong draft areas, such as windows, doors, and strong heating vents or fans.

Cabinet opening dimensions that are shown must be used.

Given dimensions provide minimum clearance.

Consult the cooktop manufacturer installation instructions before making any cutouts.

Check that the downdraft vent and cooktop location will clear the cabinet walls, backsplash, and rear wall studs inside the cabinet.

Check for the minimum distance between the front edge of the countertop and the front edge of the cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent.

All openings in ceiling and wall where the downdraft vent will be installed must be sealed.

Grounded electrical outlet is required. See “Electrical

Requirements” section.

When installing the downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to the cabinet.

Cabinet Construction:

Downdraft vent is designed for use in a cabinet with a depth of

24" (61 cm). Some installations require a countertop deeper than

25" (63.5 cm). See the “Countertop Cutout Dimensions Chart.”

The maximum depth of the overhead cabinet is 13" (33 cm).

Overhead cabinets installed at either side of the downdraft vent must be 18" (45.7 cm) above the cooking surface.

For Mobile Home Installations

The installation of this downdraft vent must conform to the Manufactured Home Construction Safety Standards,

Title 24 CFR, Part 328 (formerly the Federal Standard for

Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for

Manufactured Home Installation 1982 (Manufactured Home

Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.

Product Dimensions

Top trim widths:

30" (76.2 cm)

36" (91.4 cm)

13¹⁄₂

" (34.3 cm) retractable vent height

13

¹⁄₈

" (33.4 cm)

16

¹⁄₂

" (42.0 cm)

1

¹⁄₂

" (3.8 cm)

³⁄₈

" (0.95 cm)

27" (68.6 cm) for 30" (76.2 cm) vent

33" (83.8 cm) for 36" (91.4 cm) vent

As-Received Blower

³⁄₄

(1.9 cm)

5

¹⁄₄

"(13.3 cm) for 30" (76.2 cm) vent

8

¹⁄₄

"(21.0 cm) for 36" (91.4 cm) vent

28

¹⁄₂

"

(72.4 cm)

10"

(25.4 cm)

2

¹⁄₈

" (5.4 cm)

Reversed Blower

Front of

Range Hood

Front of

Range Hood

10" (25.4 cm)

4

³⁄₄

"

(12 cm)

10"

(25.4 cm)

16

¹⁵⁄₁₆

" (43 cm)

5

Cabinet Dimension

10

" (25.4 cm)

A=

¹⁄₂

" (12.7 mm) minimum

21

⁵⁄₁₆

"

(54.1 cm)

21⁵⁄₁₆

"

(54.1 cm)

Cutouts are for 3

¹⁄₄

" x 10"

(8.3 x 25.4 cm) rectangular or 6"

(15.2 cm) round vent system.

Locate power supply junction box at lower left hand rear corner of the cabinet.

NOTES:

See cooktop manufacturer’s instructions for cooktop cutout depth and width.

Use dimensions for vent system cutout location that applies to your installation.

Centerline of cooktop cutout

Interior mounted blower systems connect with 3

¹⁄₄" x 10"

(8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent system.

The cutout locations for this vent system will depend on your specific installation.

Countertop Cutout Dimensions

IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations.

Some models require a countertop deeper than 25" (63.5 cm); see the following “Countertop Cutout Dimensions Chart.”

To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts.

See the Installation Instructions that came with your cooktop for complete cutout dimensions, location dimensions and installation details.

D

E

F

B

C

G

H

A

I

A. Downdraft vent

B. Cooktop

C. Measurement of cooktop rear overhang

D. D = Measurement of cooktop rear overhang

(C) + 1

¹³⁄₁₆

" [46.2 mm] (E)

E. 1

¹³⁄₁₆

" (46.2 mm)

F. ½" (12.7 mm) minimum

G. ¼" (6.4 mm) minimum

H. Countertop and backsplash

I. ½" (12.7 mm) minimum

6