INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed here.
Tools Needed
■
Jigsaw or keyhole saw
■
■
■
Drill
¹⁄₈" (3 mm) drill bit for pilot holes
Pencil
■
■
■
■
■
■
■
■
■
Tape measure or ruler
Flat-blade screwdriver
Phillips screwdriver
³⁄₈" (9.5 mm) nut driver
Level
Pliers
Metal snips
Wire stripper or utility knife
Caulking gun and weatherproof caulking compound
Parts Supplied
■
Top trim - stainless
■
■
■
■
■
■
■
■
■
■
End caps (2)
Lower support legs (2)
Undercounter mounting brackets (2)
4 x 8 mm screws (16)
3.5 x 9.5 mm screws (3)
3
¹⁄₄" x 10" (8.3 x 25.4 cm) rectangular damper
4
³⁄₄" (12.0 cm) motor box
¼" (6.4 mm) deep cover
Flat vent cover plate
6" (15.2 cm) diameter vent transition with damper
Parts Needed
■
UL listed or CSA approved ½" (12.7 mm) conduit connector
■
■
■
■
■
Wall or roof cap with damper to match vent system
Vent system
Home power supply cable
UL listed wire connectors (3)
Vent clamps/duct tape as required
Location Requirements
NOTE: Downdraft vent is installed directly behind the cooktop.
Install the downdraft vent first, then install the cooktop.
IMPORTANT: Observe all governing codes and ordinances.
■
Have a qualified technician install the downdraft vent. It is the installer’s responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located on the front of the downdraft vent above the terminal box cover.
■
■
■
■
Downdraft vent location should be away from strong draft areas, such as windows, doors, and strong heating vents or fans.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Consult the cooktop manufacturer installation instructions before making any cutouts.
Check that the downdraft vent and cooktop location will clear the cabinet walls, backsplash, and rear wall studs inside the cabinet.
Check for the minimum distance between the front edge of the countertop and the front edge of the cooktop. The minimum horizontal distance between the overhead cabinets is the same as the width of the installed downdraft vent.
All openings in ceiling and wall where the downdraft vent will be installed must be sealed.
■
■
Grounded electrical outlet is required. See “Electrical
Requirements” section.
When installing the downdraft vent, the cabinet drawer will need to be removed and the drawer front installed permanently to the cabinet.
Cabinet Construction:
Downdraft vent is designed for use in a cabinet with a depth of
24" (61 cm). Some installations require a countertop deeper than
25" (63.5 cm). See the “Countertop Cutout Dimensions Chart.”
The maximum depth of the overhead cabinet is 13" (33 cm).
Overhead cabinets installed at either side of the downdraft vent must be 18" (45.7 cm) above the cooking surface.
For Mobile Home Installations
The installation of this downdraft vent must conform to the Manufactured Home Construction Safety Standards,
Title 24 CFR, Part 328 (formerly the Federal Standard for
Mobile Home Construction and Safety, title 24, HUD, Part 280) or when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
Product Dimensions
Top trim widths:
30" (76.2 cm)
36" (91.4 cm)
13¹⁄₂
" (34.3 cm) retractable vent height
13
¹⁄₈
" (33.4 cm)
16
¹⁄₂
" (42.0 cm)
1
¹⁄₂
" (3.8 cm)
³⁄₈
" (0.95 cm)
27" (68.6 cm) for 30" (76.2 cm) vent
33" (83.8 cm) for 36" (91.4 cm) vent
As-Received Blower
³⁄₄
(1.9 cm)
5
¹⁄₄
"(13.3 cm) for 30" (76.2 cm) vent
8
¹⁄₄
"(21.0 cm) for 36" (91.4 cm) vent
28
¹⁄₂
"
(72.4 cm)
10"
(25.4 cm)
2
¹⁄₈
" (5.4 cm)
Reversed Blower
Front of
Range Hood
Front of
Range Hood
10" (25.4 cm)
4
³⁄₄
"
(12 cm)
10"
(25.4 cm)
16
¹⁵⁄₁₆
" (43 cm)
5
Cabinet Dimension
10
" (25.4 cm)
A=
¹⁄₂
" (12.7 mm) minimum
21
⁵⁄₁₆
"
(54.1 cm)
21⁵⁄₁₆
"
(54.1 cm)
Cutouts are for 3
¹⁄₄
" x 10"
(8.3 x 25.4 cm) rectangular or 6"
(15.2 cm) round vent system.
Locate power supply junction box at lower left hand rear corner of the cabinet.
NOTES:
■
See cooktop manufacturer’s instructions for cooktop cutout depth and width.
■
Use dimensions for vent system cutout location that applies to your installation.
Centerline of cooktop cutout
■
Interior mounted blower systems connect with 3
¹⁄₄" x 10"
(8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent system.
The cutout locations for this vent system will depend on your specific installation.
Countertop Cutout Dimensions
IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations.
Some models require a countertop deeper than 25" (63.5 cm); see the following “Countertop Cutout Dimensions Chart.”
To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts.
See the Installation Instructions that came with your cooktop for complete cutout dimensions, location dimensions and installation details.
D
E
F
B
C
G
H
A
I
A. Downdraft vent
B. Cooktop
C. Measurement of cooktop rear overhang
D. D = Measurement of cooktop rear overhang
(C) + 1
¹³⁄₁₆
" [46.2 mm] (E)
E. 1
¹³⁄₁₆
" (46.2 mm)
F. ½" (12.7 mm) minimum
G. ¼" (6.4 mm) minimum
H. Countertop and backsplash
I. ½" (12.7 mm) minimum
6
advertisement
Related manuals
advertisement
Table of contents
- 2 VENT SYSTEM SAFETY
- 4 INSTALLATION REQUIREMENTS
- 4 Tools and Parts
- 4 Location Requirements
- 7 Electrical Requirements
- 7 Venting Requirements
- 8 INSTALLATION INSTRUCTIONS
- 8 Venting Methods
- 9 Install Vent System
- 11 Rear Mounting - Blower Motor
- 12 Complete Installation
- 13 Make Electrical Connections
- 13 Check Operation
- 14 VENT SYSTEM USE
- 14 Operating Downdraft Vent
- 14 VENT SYSTEM CARE
- 14 Surface of Downdraft Vent
- 14 Filters
- 15 WIRING DIAGRAM
- 16 ASSISTANCE OR SERVICE
- 16 In the U.S.A
- 16 In Canada
- 16 Accessories
- 17 WARRANTY
- 19 SÉCURITÉ DU SYSTÈME DE VENTILATION
- 21 EXIGENCES D'INSTALLATION
- 21 Outils et pièces
- 21 Exigences d’emplacement
- 24 Spécifications électriques
- 24 Exigences concernant l'évacuation
- 25 INSTRUCTIONS D'INSTALLATION
- 25 Méthodes d’évacuation
- 26 Installation du conduit d’évacuation
- 28 Montage du ventilateur à l'arrière
- 29 Achever l’installation
- 30 Raccordements électriques
- 31 Contrôle du fonctionnement
- 31 UTILISATION DU SYSTÈME D’EXTRACTION
- 31 Utilisation du système d’extraction par le bas
- 32 ENTRETIEN DU SYSTÈME D’ÉVACUATION
- 32 Surface du système d’extraction par le bas
- 32 Filtres
- 33 SCHÉMA DE CÂBLAGE
- 34 ASSISTANCE OU SERVICE
- 34 Au Canada
- 34 Accessoires
- 35 GARANTIE