NOTE: The downdraft vent system is supplied with a 3
¹⁄₄" x 10"
(8.3 x 25.4 cm) back draft damper and a 6" (15.2 cm) round vent transition with damper. Refer to “3
¹⁄₄" x 10" (8.3 x 25.4 cm) back draft damper” or “6" (15.2 cm) round vent transition with
3. Determine which direction (front or rear) the home power supply cable will enter the terminal box. Remove the appropriate knockout from the front or rear panel and install a
¹⁄₂" (12.7 mm) UL listed or CSA approved conduit connector.
damper,” depending upon the type of venting you are using.
4. Using 2 or more people, insert the downdraft vent into the
3
¹⁄₄" x 10" (8.3 x 25.4 cm) Back Draft Damper
1. Attach the 3¼" x 10" (8.3 x 25.4 cm) back draft damper to the vent opening in the blower motor box, using three
3.5 x 9.5 mm screws.
countertop cutout. Position downdraft vent so it is centered in the cutout with the rear flange over the edge of the cutout and the rear of the vent box against the edge of the cutout.
A
B
A
G
B
C
D
A
A. 3.5 x 9.5 mm screws
B. 3¼" x 10" (8.3 x 25.4 cm) back draft damper
6" (15.2 cm) Round Vent Transition With Damper
1. Attach the 6" (15.2 cm) round vent transition to vent opening
(left or right side venting only is recommended), using two
3.5 x 9.5 mm screws.
A
E
F
A. Rear flange of downdraft vent
B. Edge of cutout in countertop
C. Rear of downdraft vent
D. Cabinet back
E. Lower support leg
F. Cabinet floor
G. Countertop
5. Drill 2 pilot holes through each of the undercounter mounting brackets into the underside of the countertop. Using 2 screws
(not provided) of the appropriate length, mount the brackets to the countertop.
IMPORTANT: Select a screw length that will not allow the screws to go through the countertop when tightened.
B
C
B
A. 3.5 x 9.5 mm screws
B. 6" (15.2 cm) round vent transition with damper
2. Remove 4 screws attaching the terminal box cover.
A
A. Screws
B. Backsplash
C. Countertop
6. Check that the downdraft vent is level vertically. Loosen the lower support legs screws and position the legs against the cabinet floor.
A
A. Terminal box cover
12
advertisement
Related manuals
advertisement
Table of contents
- 2 VENT SYSTEM SAFETY
- 4 INSTALLATION REQUIREMENTS
- 4 Tools and Parts
- 4 Location Requirements
- 7 Electrical Requirements
- 7 Venting Requirements
- 8 INSTALLATION INSTRUCTIONS
- 8 Venting Methods
- 9 Install Vent System
- 11 Rear Mounting - Blower Motor
- 12 Complete Installation
- 13 Make Electrical Connections
- 13 Check Operation
- 14 VENT SYSTEM USE
- 14 Operating Downdraft Vent
- 14 VENT SYSTEM CARE
- 14 Surface of Downdraft Vent
- 14 Filters
- 15 WIRING DIAGRAM
- 16 ASSISTANCE OR SERVICE
- 16 In the U.S.A
- 16 In Canada
- 16 Accessories
- 17 WARRANTY
- 19 SÉCURITÉ DU SYSTÈME DE VENTILATION
- 21 EXIGENCES D'INSTALLATION
- 21 Outils et pièces
- 21 Exigences d’emplacement
- 24 Spécifications électriques
- 24 Exigences concernant l'évacuation
- 25 INSTRUCTIONS D'INSTALLATION
- 25 Méthodes d’évacuation
- 26 Installation du conduit d’évacuation
- 28 Montage du ventilateur à l'arrière
- 29 Achever l’installation
- 30 Raccordements électriques
- 31 Contrôle du fonctionnement
- 31 UTILISATION DU SYSTÈME D’EXTRACTION
- 31 Utilisation du système d’extraction par le bas
- 32 ENTRETIEN DU SYSTÈME D’ÉVACUATION
- 32 Surface du système d’extraction par le bas
- 32 Filtres
- 33 SCHÉMA DE CÂBLAGE
- 34 ASSISTANCE OU SERVICE
- 34 Au Canada
- 34 Accessoires
- 35 GARANTIE