Ending CC Temperature control
The temperature control can be ended at any time by pressing the function key T3 (65).
The temperature control and circulation is immediately stopped. Alternatively, to set the unit to standby mode and use the main menu point Start & Stop - menu point Stop
temperature control.
For units with compressor:
The main switch (36) can be used to turn the power off only after the compressor has been stopped by the controller.
Room temperature should be reached before the temperature control is ended.
Protect your application by NOT closing any isolation and drain valves. Overpressure / underpressure can be built up within the system if valves are closed and temperature adjustment takes place.
67
advertisement
Related manuals
Download
PDF
advertisement
Table of contents
- 4 Foreword
- 5 Quick guide for CC-thermostats
- 7 Chapter 1: Safety
- 8 Description of Safety and Information symbols
- 9 Intended Use and General Safety Instructions
- 10 Description
- 11 Duties of responsible person
- 11 Operator requirements
- 11 Machine operator duties
- 11 Work area
- 12 Safety Devices to DIN
- 14 Additional Protection Devices
- 14 Environmental Conditions
- 15 Operating conditions
- 16 Location
- 17 Thermal fluids
- 18 Chapter 2: Electronics and operation
- 19 CC-Pilot
- 20 Information Displays CC
- 23 Real-time clock
- 23 Rechargeable Battery
- 23 Event Function
- 24 Operation CC
- 25 CC Operation using the rotary knob
- 26 CC Operation using the simulated Number Pad
- 27 Main menu
- 28 Compact menu
- 36 Comfort menu
- 43 Com.G@te menu
- 50 Function Numbers and their meaning
- 56 User menu – config
- 57 User menu - select
- 58 Chapter 3: Connect the machine, fill and prepare for the required application
- 59 Power connection
- 59 Safety instructions
- 59 Start up
- 59 Protection)
- 60 Water-cooling (valid for units with water cooling)
- 61 Operation as bath thermostat (valid for temperature control units with baths)
- 62 Connecting an externally closed application (reactor)
- 63 Switching on the temperature control unit
- 63 Setting the over-temperature (OT) switch
- 66 Setting the set-point limits
- 66 Entering a set-point
- 66 Starting CC Temperature control
- 67 Ending CC Temperature control
- 68 Filling and air purging an externally closed system
- 69 Draining the machine and an externally closed application
- 69 Changing thermal fluid / internal cleaning
- 70 Chapter 4: Interfaces
- 73 RS232/SERIAL
- 74 Mutual functions Com.G@te/Web.G@te
- 76 Specific functions Com.G@te
- 77 Specific functions Web.G@te
- 82 Chapter 5: First aid for a fault condition
- 83 Messages
- 84 Display Error Messages
- 84 Alarms and Warnings
- 84 System Messages
- 85 Alarm and Warning codes
- 85 Hard Alarms (not resettable)
- 88 Exchange of the CC Electronics / Remote Control
- 88 Remote Control
- 89 Maintenance
- 90 Decontamination / Repair
- 90 Cleaning the surfaces
- 90 Plug contacts
- 91 Chapter 6: Taking the machine out of service
- 92 Decommissioning
- 93 Transport
- 93 Disposal