RS232/SERIAL. Huber CC-510w, K12-cc-NR, CC-410wl, variostat cc, CC-905, K6s-cc-NR, ministat 240w-cc, CC-505wl, CC-805, ministat 125-cc
Add to My manuals94 Pages
advertisement
The following interfaces are available:
1. RS232/SERIAL (Standard Interface! Included in all CC units with CC-Pilot)
2. Com.G@te internal or external version depending on the unit (Extension of an analogue interface or a further digital interface)
3. Web.G@te internal or external version depending on the unit (Control possible via Intranet, Internet, USB…)
Caution!
With plug-in connections subject to a higher voltage than 60 V (AC) and 40 V (DC) there is the risk of receiving an electric shock or of damaging the interface module. Only components requiring voltages of less than 60 V (AC) and 40 V (DC) should be connected, in order to ensure the safety of the interface module.
RS232/SERIAL
5
9 6
1
Wiring RS232:
Pin2
TxD
Pin5 Signal
The Baudrate is set to 9600. It cannot be changed! An operation via the interface
RS232/SERIAL is not possible if the temperature control unit is controlled via remote control by the CC-Pilot.
73
advertisement
Related manuals
advertisement
Table of contents
- 4 Foreword
- 5 Quick guide for CC-thermostats
- 7 Chapter 1: Safety
- 8 Description of Safety and Information symbols
- 9 Intended Use and General Safety Instructions
- 10 Description
- 11 Duties of responsible person
- 11 Operator requirements
- 11 Machine operator duties
- 11 Work area
- 12 Safety Devices to DIN
- 14 Additional Protection Devices
- 14 Environmental Conditions
- 15 Operating conditions
- 16 Location
- 17 Thermal fluids
- 18 Chapter 2: Electronics and operation
- 19 CC-Pilot
- 20 Information Displays CC
- 23 Real-time clock
- 23 Rechargeable Battery
- 23 Event Function
- 24 Operation CC
- 25 CC Operation using the rotary knob
- 26 CC Operation using the simulated Number Pad
- 27 Main menu
- 28 Compact menu
- 36 Comfort menu
- 43 Com.G@te menu
- 50 Function Numbers and their meaning
- 56 User menu – config
- 57 User menu - select
- 58 Chapter 3: Connect the machine, fill and prepare for the required application
- 59 Power connection
- 59 Safety instructions
- 59 Start up
- 59 Protection)
- 60 Water-cooling (valid for units with water cooling)
- 61 Operation as bath thermostat (valid for temperature control units with baths)
- 62 Connecting an externally closed application (reactor)
- 63 Switching on the temperature control unit
- 63 Setting the over-temperature (OT) switch
- 66 Setting the set-point limits
- 66 Entering a set-point
- 66 Starting CC Temperature control
- 67 Ending CC Temperature control
- 68 Filling and air purging an externally closed system
- 69 Draining the machine and an externally closed application
- 69 Changing thermal fluid / internal cleaning
- 70 Chapter 4: Interfaces
- 73 RS232/SERIAL
- 74 Mutual functions Com.G@te/Web.G@te
- 76 Specific functions Com.G@te
- 77 Specific functions Web.G@te
- 82 Chapter 5: First aid for a fault condition
- 83 Messages
- 84 Display Error Messages
- 84 Alarms and Warnings
- 84 System Messages
- 85 Alarm and Warning codes
- 85 Hard Alarms (not resettable)
- 88 Exchange of the CC Electronics / Remote Control
- 88 Remote Control
- 89 Maintenance
- 90 Decontamination / Repair
- 90 Cleaning the surfaces
- 90 Plug contacts
- 91 Chapter 6: Taking the machine out of service
- 92 Decommissioning
- 93 Transport
- 93 Disposal