1-1
Chapter 1.
ECC Overview
This chapter explains the composition of Compuware’s Enterprise Common Components
(ECC) and provides overview information on each of its component parts.
What is ECC?
Beginning with Release 16.05, Enterprise Common Components represents a single install image for the following Compuware facilities:
• Compuware Mainframe Services Controller (CMSC)
• License Management System (LMS)
• Compuware Shared Services (CSS)
• Host Communications Interface (HCI)
• Base Services
Note: The Compuware Installer is included as part of the ECC EP media and is only used to facilitate SMP/E installation of Compuware mainframe products. It is not part of the Enterprise Common Components single install image.
All components in the ECC single install image are on the same release level.
Compuware recommends that you install and activate all of the components at the same time to avoid compatibility issues between different release levels.
CMSC, CSS, LMS, HCI, and Base Services are all installed with a single install image and a single FMID. Which parts of ECC you need to activate and configure depends on which
Compuware products are licensed by your organization. All Compuware mainframe products require the License Management System. Many Compuware products use
Compuware Shared Services to provide crucial core functionality. Abend-AID, Abend-AID for CICS, Strobe, DevEnterprise, Hiperstation, Compuware Workbench, and Topaz
Workbench use the HCI component. Abend-AID, Abend-AID for CICS, and CMSC use
Base Services. Table 2-1 on page 2-1 in Chapter 2, “Preparing for ECC Installation” makes
it easy to determine exactly which parts of ECC you need to install.
Each of the components are installed with the ECC single install image using SMP/E and can be configured individually, depending on your site’s requirements:
• Compuware Mainframe Services Controller (CMSC): The Compuware Mainframe
Services Controller (CMSC) address space is a centralized facility providing license management and common parameter library services. The CMSC also has the ability to automatically start HCI address spaces. HCI address spaces started by the CMSC will be automatically restarted in the event of a failure. Operator commands are provided to control the Compuware License Management System. Commands are also provided to control HCI address spaces automatically started by the CMSC.
Compuware intends to add additional functionality to the CMSC in the future.
As the service provider for the new Compuware common parameter library feature, the CMSC reads the user’s parameter libraries, stores parameters for Compuware products in memory, and initializes the parameter retrieval service used by
Compuware products. Operator commands are provided to refresh the parameters in memory in the event of a change to one or more of the parameter library members.
• License Management System (LMS): LMS enables you to manage access to all the
Compuware products used by your organization. LMS consists of several small
1-2
Enterprise Common Components Installation and Customization Guide
components which allow you to establish, maintain, diagnose, and upgrade your access to the Compuware products licensed by your enterprise:
– An ISPF License Administration Utility application
– A runtime environment
– A program interface to the runtime environment employed by Compuware products.
LMS License Certificates are English-like text files that are sent to you electronically.
You will receive a License Certificate for each new product release under LMS. You can centrally manage all of your organization’s License Certificates in a single
License File that can then be distributed to various sites.
• Compuware Shared Services (CSS): An enterprise-wide tool for sharing compiled program information, CSS is utilized by many Compuware products spanning the
Fault Management and Enterprise Testing Solutions product lines. For more
information, see “CSS Overview”.
• Host Communications Interface (HCI): The Host Communications Interface is a facility that provides connectivity between mainframe-based programmer productivity software and peer-node software running on other platforms in a network. The HCI also serves as a server activation facility that is responsible for starting and monitoring application programs that are using the communications facilities.
• Base Services: Base Services is an application framework providing batch, server, subsystem and presentation components. Functions provided by Base Services include dynamic allocation, storage management, transaction scheduling, message formatting, operator command routing, recovery and termination management, and screen, menu and message presentation in ISPF, VTAM, CICS and Web browser environments. This framework is used by CMSC, Abend-AID and Abend-AID for
CICS.
• Compuware Installer: Use the Compuware Installer to facilitate the SMP/E installation of Compuware mainframe products. See the Compuware Installer—
Mainframe Product SMP/E Installation Guide for more information.
LMS Overview
LMS is a feature of the ECC single install image. LMS enables you to centrally administer
Compuware’s product License Certificates and manage access to Compuware products at your site.
Beginning with Release 16.05, LMS will execute in the CMSC address space.
LMS Advantages
LMS provides the following advantages:
• Electronically-delivered License Certificates that contain product access parameters in a human-readable text format
• Programs and reports to verify the contents of the License File and LMS runtime environment
• Capability to employ a single centralized Enterprise License File and centralized administration of License Files
• Easy updates to License Certificates and the License File with no disruption to your
Compuware products
• No production impact from the testing of LMS runtime systems, installation and validation of new License Certificates, or installation of new or updated LMS software
ECC Overview
1-3
• Optional E-mail alerts and SMF logging when licensing events occur.
Operating Environment
LMS operates under IBM MVS/ESA Release 4.3 and more current, and all OS/390 and z/OS releases.
The License Management Process
The license management process begins when you acquire a Compuware product through a license agreement, trial agreement, or beta agreement.
Information Gathering
Compuware obtains the relevant information for license management from you at the time of the agreement. Your organization supplies information such as name and the sites and CPUs for which the product is being licensed. Information about the
Compuware product licensed, such as product name, release number, and options licensed, is obtained from your Compuware representative.
License Certificate
Upon the completion of an agreement, Compuware creates a License Certificate representing a portion of the information in that agreement. The License Certificate is used by LMS to provide access to Compuware products. The License Certificate is not the same thing as a license agreement. You are still responsible for abiding by your license agreement, and although not its primary role, you will find that the LMS can help in that effort.
The License Certificate, LMS, and the Compuware product are all delivered to you by
Compuware. Typically, you receive the License Certificate via e-mail, but other methods can be used, if necessary.
Installation
LMS is included as part of the ECC single install image. First, set up your LMS environment, import your License Certificate into a License File, execute the CMSC
address space, and install your Compuware products. From then on, access to your
Compuware mainframe products occurs transparently.
After you accomplish the initial LMS installation, you would typically only need to import a new product License Certificate and re-initialize the LMS runtime environment in conjunction with events such as the following:
• obtaining a new release of a product under the terms of your software maintenance agreement
• adding new products through additional license agreements
• amending your agreement to include new options
• changing the CPUs licensed in your original agreement.
CSS Overview
Compuware Shared Services (CSS) is an integral component of many Compuware products spanning the Fault Diagnosis, Interactive Analysis and Debugging, File and Data
Management, and Application Performance Measurement product lines. CSS provides storage, retrieval, and maintenance for Abend-AID reports, source listings, and transaction dump information in datasets called DDIO files. Shared directories and their attached databases are also types of DDIO files being utilized for more efficiency in
1-4
Enterprise Common Components Installation and Customization Guide
maintaining information and activity within these files. CSS also provides language processing support for COBOL, PL/I, Assembler, and C.
The following products currently use CSS:
• Abend-AID
• Abend-AID for CICS
• Compuware Workbench/Topaz Workbench
• Strobe
• Xpediter/CICS
• Xpediter/Code Coverage
• Xpediter/TSO and Xpediter/IMS
System Environment
For System Requirement information, see the Enterprise Common Components Release Notes available from GO/Frontline (http://go.compuware.com).
CSS Components
CSS consists of the following components:
• Compuware common files and utilities
– DDIO files: Source Listing Files, Report Files, Shared Directories and Associated
Report, Transaction, and Source Listing Databases
– Batch file utilities: CWDDSUTL, CWFXSDUT, CWAASDUT, CWDDLPUT, and
CWDDALLU
• Compuware Language Processors (COBOL, Assembler, PL/I, and C)
• Security Exit Program
• Topaz Workbench support
Common Files and Utilities
CSS components include common files and utilities that provide storage, retrieval, and maintenance functions.
DDIO Files
A generic term used to describe the proprietary file access method that stores Abend-AID reports, transaction dump information, and source listings for several Compuware products. DDIO files can be allocated as either VSAM or sequential datasets. Different products may require different types of DDIO files.
CSS Utilities and Batch File Utilities
CSS Utilities walks you step-by-step through CSS language processor functions and DDIO file manipulation using easy-to-use panels.
The batch file utilities (CWDDSUTL, CWAASDUT, CWDDLPUT, CWFXSDUT and
CWDDALLU) provide the same functions as CSS Utilities in a batch environment.
For information on the available online utility functions refer to the “CSS Utilities” chapter in the Compuware Shared Services User/Reference Guide. For information on the available batch utility commands and parameters for CWDDALLU or CWDDSUTL,
CWAASDUT, CWFXSDUT and CWDDLPUT refer to the “Batch File Utility CWDDALLU” chapter in the Compuware Shared Services User/Reference Guide.
ECC Overview
1-5
CSS Language Processors (LP)
The language processors capture information about a compiler listing and store it in a source listing DDIO file. The majority of this information is gathered from the compiler listing, but optionally, SYSIN and SYSLIB are also examined. The source listing DDIO file may be in standard DDIO, shared directory, or database format.
A language processor can be run using two methods:
• preprocessor
• post-processor
You may use the preprocessor or post-processor (whichever is best for your site as needed.) For information about the pre- and post-processors, refer to the appropriate language processor chapter in the Compuware Shared Services User/Reference Guide. See the applicable language processor chapter for when to use the pre- or post-processor.
Language Processor Types
CSS provides language processing support for the following languages:
• COBOL
• PL/I
• Assembler
• C
The COBOL language processor reads the compiler listing produced by the COBOL compiler and writes either a compiler listing or an enhanced listing to the DDIO file. The enhanced listing merges the information normally found in the data division map
(DMAP) and the condensed listing (CLIST) or procedure map (PMAP) into the source statement lines. The COBOL compiler options in effect are sorted alphabetically and appear at the beginning of the enhanced listing. The enhanced listing provides you with a condensed hardcopy of the compiler information.
The COBOL and PL/I listings may be used to provide source support using any of the following products:
• Abend-AID
• Abend-AID for CICS
• Strobe and iStrobe
• Xpediter/CICS
• Xpediter/TSO
• Xpediter/Eclipse
The Assembler listings may be used to provide source support using any of the following products:
• Abend-AID
• Strobe and iStrobe
• Xpediter/CICS
• Xpediter/TSO
• Xpediter/Eclipse
The C language processor reads the compiler listing produced by the C compiler and writes the compiler listing to the DDIO file and SYSCPRT. The source listing in DDIO can then be used to provide source support when using:
• Xpediter/TSO
• Xpediter/CICS
• Strobe and iStrobe
1-6
Enterprise Common Components Installation and Customization Guide
Security Exit Program
CSS also includes the Compuware Security Exit Program. This is an optional user-written exit for your Compuware products. It can be used in conjunction with your existing security package to secure sensitive data used by the following Compuware products:
• Abend-AID
• Abend-AID for CICS
• Xpediter/CICS
• Xpediter/TSO and Xpediter/IMS
• Xpediter/Code Coverage
• Strobe
The Compuware Security Exit enables you to control access to DDIO file members or restrict access to various commands through a user-written exit program. For the Abend-
AID for CICS product, you can restrict access to some of the CWFXSDUT and
CWDDALLU functions for transaction database and source listing files. For transaction databases, you can use the Security Exit Program to restrict access to individual dumps within a transaction database.
If you install a Security Exit program, it will be called by all Compuware products installed at your site. For more information on the Security Exit Program, see the “CSS
Security Exit” chapter in the Compuware Shared Services User/Reference Guide.
Executing CSS
CSS is primarily executed at the following times:
• Abend-AID and Abend-AID for CICS
– at compile time (when source support is used)
– at time of abend or application program failure
– at view time when using the Abend-AID Viewer
– at installation and maintenance time when formatting a DDIO file.
– when a compile listing that has been stored elsewhere is needed for Abend-AID or Abend-AID for CICS viewing with source support.
• Xpediter/TSO and Xpediter/CICS
– at compile time (when source support is used)
– at execution time for interactive debugging
– at installation and maintenance time when formatting a DDIO file.
• Strobe
– when indexing is used to analyze measurement data
– to support Web services and SQLAF processing through CSS TP of HCI
• Compuware Workbench/Topaz Workbench
– to support Web Services needs through the CSS TP and other HCI related facilities (SSAS and STASK)
HCI Overview
The Host Communications Interface (HCI) is a facility that provides connectivity between mainframe-based programmer productivity software and peer-node software running on other platforms in a network. These communications facilities provide a simple application programming interface so that Compuware software can be written to communicate with peer programs running on different platforms. Additionally, the communications system is flexible, simple to operate, and reliable. It has been designed to support open-ended communications protocols, and it can operate on older releases of
ECC Overview
1-7
the MVS operating system. It allows application programs to communicate over any one of several protocols without knowing which protocol is in use at any given time.
The HCI also serves as a server activation facility that is responsible for starting and monitoring application programs that are using the communications facilities.
And finally, the HCI has been designed with no architected upper limit on the number of concurrent sessions supported, nor on throughput rates. The following figure shows how the HCI fits into the scheme of the TP application and the MVS subsystem components.
Figure 1-1. TP Subsystem, HCI and Application. HCI Position as Middleware
TCP/IP
Application
Application
HCI
VTAM
Application
Figure 1-2. Workstation/Mainframe Connectivity
Workstation 1
Workstation 2
TCP/IP Address
Space
HCI Address
Space
(CSS TP) Communication Tasks
(SSAS)
Shared Services
(CSS STASK)
File-AID/Eclipse
Session
Base Services Overview
Base Services is an application framework providing batch, server, subsystem and presentation components. Functions provided by Base Services include dynamic allocation, storage management, transaction scheduling, message formatting, operator command routing, recovery and termination management, and screen, menu and message presentation in ISPF, VTAM, CICS and Web browser environments. This framework is used by Compuware Mainframe Services Controller (CMSC), Abend-AID and Abend-AID for CICS.
Beginning with Version 16.05 Base Services is part of Enterprise Common Components
(ECC) installation libraries.
Special ECC 16.05 Upgrade Consideration with Abend-AID 12.04
For Abend-AID release 12.04 and prior, Base Services was installed as part of Abend-AID
Common Components. However, Base Services was removed from Abend-AID release
16.05 to become part of ECC 16.05. If you are upgrading to ECC 16.05 but not upgrading
1-8
Enterprise Common Components Installation and Customization Guide
Abend-AID to release 16.05, then the following the procedures must be implemented to allow your existing Abend-AID installation to function correctly with ECC 16.05.
Note: You may continue to use Abend-AID release 12.04 (and below) with your prior version of CSS. However, if you want to change existing Abend-AID servers to use the ECC 16.05 load libraries then these changes will be needed:
BDCAS
In the step that executes program FDBMMPLU
• Add the 16.05 ECC SLCXAUTH as the first library on STEPLIB
• Add the 16.05 ECC SLCXLOAD as the first library on FDBDRPL
• Remove the existing SLCXLOAD from FDBDRPL
If you have steps to execute program FDBASUBS to start or stop an Abend-AID subsystem, update STEPLIB to remove the Abend-AID Common library SKAZAUTH and replace it with the 16.05 ECC SLCXAUTH library.
TDCAS
In the step that executes program FDBMMPLU
• Add the 16.05 ECC SLCXAUTH as the first library on STEPLIB
• Remove the HCI library SLHCAUTH from STEPLIB
• Add the 16.05 ECC SLCXLOAD as the first library on FDBDRPL
• Remove the existing SLCXLOAD from FDBDRPL
• Remove the HCI library SLHCLOAD from FDBDRPL
If you have steps to execute program FDBASUBS to start or stop an Abend-AID subsystem, update STEPLIB to remove the Abend-AID Common library SKAZAUTH and replace it with the 16.05 ECC SLCXAUTH library.
VIEWING SERVER
In the step that executes program FDBMMPLU
• Add the 16.05 ECC SLCXAUTH as the first library on STEPLIB
• Remove the HCI library SLHCAUTH from STEPLIB
• Add the 16.05 ECC SLCXLOAD as the first library on FDBDRPL
• Remove the existing SLCXLOAD from FDBDRPL
• Remove the HCI library SLHCLOAD from FDBDRPL
If you have steps to execute program FDBASUBS to start or stop an Abend-AID subsystem, update STEPLIB to remove the Abend-AID Common library SKAZAUTH and replace it with the 16.05 ECC SLCXAUTH library.