Getting Started
Private Community String
Public Community String
This menu entry allows you to set the Private Community string.
This string is effectively a password. Without this string, SNMP commands cannot change values in the instrument.
NOTE.
The Private String is necessary for SNMP access to write changes into the instrument.
This menu entry allows you to set the Public Community string.
This string is effectively a password. Without this string, SNMP commands cannot read values from the instrument.
NOTE.
The Public String is necessary for SNMP access to read values from the instrument.
Incoming Inspection
The incoming inspection procedures are optional procedures to check the functionality of your instrument. These procedures require no equipment other than an external monitor or display. For a more robust inspection, see the performance verification procedures in the WVR7200 Specifications and
Performance Verification Technical Reference that is included on the Product
Documentation CD that shipped with your instrument.
Basic Turn On and Self
Test
The following test can performed with or without the external monitor. Using the external monitor allows you to check that the DVI connector on the rear panel is working properly.
1. Connect a monitor to the EXT DISPLAY connector on the rear panel of the instrument. This connector is a DVI-I connector with socket contacts. The output supports DVI monitors directly and analog PC (RGB) monitors using a
DVI-I to VGA adapter.
2. Connect the AC line cord to the rear of the instrument and to a 100 to
240 VAC source.
10 WVR7200 Waveform Rasterizers User Manual
Getting Started
Figure 2: Rear panel
3. Press the Power button on the front panel to turn the instrument on. It is located on the bottom left corner of the front panel.
WVR7200 Waveform Rasterizers User Manual 11
Getting Started
Figure 3: Front panel
4. After about 30 seconds, the power-on diagnostic page should appear on the screen.
5. Verify that all self tests pass. Any failures are shown in red. The results of the power-on diagnostics are erased from the screen, but you can view the results by selecting CONFIG > Utilities > View Diagnostics Log > SEL or by viewing them on the instrument Web page.
6. After the diagnostics are finished, the instrument state is restored. When the progress indicator in the status bar is finished, the instrument has finished initializing.
7. Record Pass or Fail for the POST (Power On Self Test) in the test record.
8. If it is still open, exit the Diagnostics Log.
Front Panel Test
1. Press and hold the PRESET button.
2. Use the GENERAL knob to navigate to Recall Preset.
3. Press the right and down arrow keys to navigate to Recall Factory Preset and press the SEL button.
12 WVR7200 Waveform Rasterizers User Manual
Getting Started
4. Press the FULL button to change the display screen from 4-tile view to single-tile view.
5. Press the HELP button to display the help screen.
6. Press all of the other buttons, one at a time.
Each button should flash as you press it. Most buttons show related help text.
Some buttons, such as the presets, show the same information. The HELP button, the four arrow keys, and the SEL button do not show help text, but are used to navigate the help panes and content.
Figure 4: Instrument online help
7. Press the right arrow key until the Help Contents pane in the upper-left corner of the help display is highlighted.
8. Turn the GENERAL knob and check that the selector box moves up and down the list.
9. Press the HELP button to exit help.
Fan Test
You should be able to hear the fans and feel air coming out of the back of the instrument. At low temperatures, the fans will turn slowly and be very quiet.
WVR7200 Waveform Rasterizers User Manual 13
Getting Started
14 WVR7200 Waveform Rasterizers User Manual
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 28 Incoming Inspection
- 33 Getting Acquainted With Your Instrument
- 33 Front-Panel Controls
- 36 Remote Front Panel Control
- 36 Instrument Online Help
- 37 Instrument Display
- 41 Signal Inputs
- 41 SDI Signals
- 43 Composite Signals
- 44 Dual Link Signals
- 45 Multi-Input Display Mode
- 48 Simultaneous Input Monitoring
- 48 SyncVu
- 48 Reference Loop
- 49 Signal Generation
- 51 Display Information
- 53 Waveform Display
- 55 Vector Display
- 58 Gamut Display
- 61 Timing Display
- 65 Datalist Display
- 67 Bowtie Display
- 68 LTC Display
- 69 Ancillary (ANC) Data Display
- 71 Audio Video Delay (AVD) Display
- 72 Eye Display
- 75 Jitter Display
- 78 Status Displays
- 98 Audio Display
- 104 Picture Display
- 87 Figure 38: Audio Loudness Session display
- 89 Figure 39: Audio Control Packet format
- 90 Figure 40: Audio Control Packet structure
- 90 Figure 41: Audio Control display
- 92 Figure 42: Auxiliary Data Status display
- 94 Figure 43: Dolby Status display
- 96 Figure 44: SDI Status display
- 98 Figure 45: Audio display
- 103 Figure 46: 16-Channel audio bars display
- 104 Figure 47: Picture display showing color bars
- 105 Figure 48: VChip, CC-Display, Teletext, and Safe Area Graticule in Picture display
- 109 Figure 49: Using cursors in the waveform display
- 110 Figure 50: Navigating line selection
- 117 Figure 51: Sample of transfer.exe window after the upgrade is complete