Jennifer B.
What types of keyers are supported?
The device supports internal (logo) and external keyers.
The IconMaster is a master control switcher that provides a variety of features, including video and audio routing, keying, effects, and automation. It is designed for use in broadcast and production facilities. The IconMaster is a powerful and versatile tool that can be used to control a wide range of broadcast equipment.
Advertisement
Advertisement
4
61
Figure 4-1 Sample System Layout Including a Router, PC, Ethernet Switch and IconMaster System
62
Chapter 4
Router Connections
Note: System configurations for Panacea routers start on page 62. System configurations
for Platinum routers start on page 91.
This section describes the connections that are required in some typical configurations involving NEO NSM internal routers. The following NEO router configurations are described in this section:
IconMaster System with Internal Video NSM Router and Optional ICONM-BO-V Module
IconMaster System with Single Channel Audio and Video NSM Routers and Optional
ICONM-BO-VAC Module
IconMaster System with Internal (Two Channel) Audio and Video NSM Routers and
Optional ICONM-BO-VAC Module
Only one set of NSMs can be installed in a 3RU frame.
The source offset for all NSM modules is 1.
The destination offset for all NSM modules is 0.
The first video NSM module must be assigned an X-Y level of 0.
When ganging 2 cards together, the second module must be assigned an X-Y level of 1.
The NSM-7×2AES router supports a single AES stream for both A and B inputs on the
IconMaster. If the NSM-7×2AES routers are to be used for discrete AES audio for a full two AES (four-channel) system, four of these router modules are required.
The expected use would be as follows:
NSM #1 and NSM #2 provide AES 1 for Bus A and Bus B.
NSM #3 and NSM #4 provide AES 2 for Bus A and Bus B.
This section describes the connections that are required in a typical configurations involving an IconMaster system with an NSM video router module and an optional breakout module.
You can place the NSM modules anywhere in the same NEO frame as the IconMaster system.
Figure 4-3
on page 64 shows a detailed illustration of this process.
1
Set the NEO NSM back module to Unterminated reference:
a
Remove the NSM back module from the NEO frame.
b
Locate jumper JP1 on the NEO NSM back module (see
Figure 4-2
), and then set the
NEO NSM back module to Unterminated reference by setting JP1 as shown.
c
Reinstall the NSM back module into the NEO frame.
IconMaster
Installation and Configuration Manual
63
Jumper JP1 set to
Unterminated
Figure 4-2 Jumper JP1 on the NSM Back Module
2
Connect a maximum of 7 video inputs to the BNC connections labeled In 1 to In 7.
3
Connect Out 1 on the NSM to Input Bus A on the MKE-3901.
4
When using the ICONM-BO-VAC breakout module and NSM routers, audio output 1 from the NSM router must be connected to Bus A In 1 on the breakout module as indicated in
Figure 4-4
on page 65.
64
Chapter 4
Router Connections
When using the ICON-BO-VAB breakout module and NSM routers, the audio output 1 from the NSM router must be connected to Input Bus A1 on the breakout module as indicated in
Table 2-9
on page 54.
Figure 4-3 IconMaster System with Internal Video NSM Router and Optional ICONM-BO-V Module
IconMaster
Installation and Configuration Manual
65
Bus A In 1
Figure 4-4 Audio 1 NSM Connection to ICONM-BO-VAC
1
Connect your composite station reference to the Ref Inputs and Genlock connection as shown in
Figure 4-3
.
2
On the MKE-3901 back module, connect Key 1 input source to Key 1 and Fill 1 as appropriate.
3
On the MKE-3901 back module, connect Key 2 input source to Key 2 and Fill 2 as appropriate.
On the MKE-3901 back module, Squeeze Bkgd can be supplied by an external router.
Note: The IconMaster control panel can be connected to any network switch that shares a network with the MKE-3901 and MGI-3903 modules.
4
Connect the two Ethernet ports as follows:
Connect Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through Ethernet cable.
Connect Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
5
Power up the system.
See
on page 99 for more information.
Note: See the Installation and Operation Manual for your NEO module for more detailed information about setting parameters.
1
Press the left (Esc) button until the NSM message appears on the VFD display
2
Press the right (Sel) button.
3
Use the toggle switch (Nav) to scroll through the parameter list until Setup is highlighted.
4
Press the right (Sel) button.
5
Use the toggle switch (Nav) to scroll through the parameter list until Nav Mode is highlighted.
6
Press the right (Sel) button.
7
Use the toggle switch (Nav) to scroll through the parameter list until All List is highlighted.
8
Press the right (Sel) button.
9
Press the left (Esc) button.
10
Press the left (Esc) button again.
66
Chapter 4
Router Connections
11
Use the toggle switch (Nav) to scroll through the parameter list until XY Level is highlighted.
12
Press the right (Sel) button.
13
Use the toggle switch (Nav) to scroll through the values until 0 (on the first NSM) or 1 (on the second NSM) is reached.
14
Press the left (Esc) button to set the value.
15
Use the toggle switch (Nav) to scroll through the parameter list until SrcOffset is highlighted.
16
Press the right (Sel) button.
17
Use the toggle switch (Nav) to scroll through the values until 1 is reached.
18
Press the left (Esc) button to set the value.
19
Use the toggle switch (Nav) to scroll through the parameter list until DestOffset is highlighted.
20
Press the right (Sel) button.
21
Use the toggle switch (Nav) to scroll through the values until 0 is reached.
22
Press the left (Esc) button to set the value.
This section describes the connections that are required in a typical configurations involving an IconMaster system, with single channel audio and video NSM router modules and an optional breakout module. You can place the NSM modules anywhere in the same NEO frame as the IconMaster system.
Figure 4-6
on page 68 shows a detailed illustration of this process.
Note: The first NSM module will provide Inputs 1 to 5; the second NSM module will provide Inputs 6 to 12.
1
Set the NEO NSM back module to Unterminated reference:
a
Remove the NSM back module from the NEO Frame.
b
Locate jumper J11 on the NEO NSM back module (see
Figure 4-5
).
c
Set the NEO NSM back module to Unterminated reference by setting J11 as shown.
d
Reinstall the NSM back module into the NEO frame.
Jumper JP1 set to
Unterminated
Figure 4-5 Jumper J11 on the NSM Back Module
IconMaster
Installation and Configuration Manual
67
68
Chapter 4
Router Connections
2
On the first NSM back module, connect a maximum of 5 audio inputs to the BNC connections labeled In 1 to In 5.
Figure 4-6 IconMaster System with Internal (Single Channel) Audio and Video NSM Internal Routers and Optional
ICONM-BO-VAC Module
3
On the second NSM back module, connect a maximum of 7 video audio inputs to the BNC connections labeled In 1 to In 7.
IconMaster
Installation and Configuration Manual
69
4
Connect Out 1 on the first NSM to AES Bus A on the MKA-3901. This can be done by direct connection, or by ICONM-BO-VAB or ICONM-BO-VAC breakout module connection.
5
Connect Out 2 on the first NSM to AES Bus B on the MKA-3901.
6
Connect Out 1 on the second NSM to In 6 on the first NSM.
7
Connect Out 2 on the second NSM to In 7 on the first NSM.
1
Connect your composite station reference to the Ref Inputs and Genlock connection as shown in
Figure 4-6
.
2
On the MKE-3901 back module, connect Key 1 input source to Key 1 and Fill 1 as appropriate.
3
On the MKE-3901 back module, connect Key 2 input source to Key 2 and Fill 2 as appropriate.
4
On the MKE-3901 back module, Squeeze Bkgd can be supplied by an external router.
Note: If you are connecting Ethernet 1 to a switch, the IconMaster Control Panel must be connected to the same switch
5
Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through
Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
6
Power up the system.
See
on page 99 for more information.
Note: See the Installation and Operation Manual for your NEO module for more information about setting parameters.
1
Press the left (Esc) button until the NSM message appears on the VFD display
2
Press the right (Sel) button.
3
Use the toggle switch (Nav) to scroll through the parameter list until Setup is highlighted.
4
Press the right (Sel) button.
5
Use the toggle switch (Nav) to scroll through the parameter list until Nav Mode is highlighted.
6
Press the right (Sel) button.
7
Use the toggle switch (Nav) to scroll through the parameter list until All List is highlighted.
8
Press the right (Sel) button.
9
Press the left (Esc) button.
10
Press the left (Esc) button again.
11
Use the toggle switch (Nav) to scroll through the parameter list until XY Level is highlighted.
12
Press the right (Sel) button.
70
Chapter 4
Router Connections
13
Use the toggle switch (Nav) to scroll through the values until 2 (on the first NSM) or 3 (on the second NSM) is reached.
14
Press the left (Esc) button to set the value.
15
Use the toggle switch (Nav) to scroll through the parameter list until SrcOffset is highlighted.
16
Press the right (Sel) button.
17
Use the toggle switch (Nav) to scroll through the values until 1 is reached.
18
Press the left (Esc) button to set the value.
19
Use the toggle switch (Nav) to scroll through the parameter list until DestOffset is highlighted.
20
Press the right (Sel) button.
21
Use the toggle switch (Nav) to scroll through the values until 0 is reached.
22
Press the left (Esc) button to set the value.
This section describes the connections that are required in a typical configurations involving an IconMaster system, with two channel audio and video NSM router modules and an optional breakout module. You can place the NSM modules anywhere in the same NEO frame as the IconMaster system.
Figure 4-8
on page 72 shows a detailed illustration of this process.
Note: The first NSM module will provide Inputs 1 to 5; the second NSM module will provide Inputs 6 to 12.
1
Set the NEO NSM back module to Unterminated reference:
a
Remove the NSM back module from the NEO Frame.
b
Locate jumper J11 on the NEO NSM back module (see
Figure 4-5
).
c
Set the NEO NSM back module to Unterminated reference by setting J11 as shown.
d
Reinstall the NSM back module into the NEO frame.
Jumper JP1 set to
Unterminated
Figure 4-7 Jumper J11 on the NSM Back Module
IconMaster
Installation and Configuration Manual
71
72
Chapter 4
Router Connections
2
On the first NSM back module, connect a maximum of 5 audio inputs to the BNC connections labeled In 1 to In 5.
Figure 4-8 IconMaster System with Internal (Two Channel) Audio and Video NSM Routers and Optional
ICONM-BO-VAC Module
IconMaster
Installation and Configuration Manual
73
3
On the second NSM back module, connect a maximum of 7 video audio inputs to the BNC connections labeled In 1 to In 7.
4
Connect Out 1 on the first NSM to AES Bus A on the MKA-3901. This can be done by direct connection, or by ICONM-BO-VAB or ICONM-BO-VAC breakout module connection.
5
Connect Out 2 on the first NSM to AES Bus B on the MKA-3901.
6
Connect Out 1 on the second NSM to In 6 on the first NSM.
7
Connect Out 2 on the second NSM to In 7 on the first NSM.
Audio output 1 from the third NSM router must be connected to Bus A In 2 on the breakout module as shown in
Figure 4-9
.
Bus A In 2
Figure 4-9 Audio Output 1 From Third NSM Router to Bus A In 2
Audio output 2 from the third NSM router must be connected to Bus B In 2 on the breakout module, as indicated in
Figure 4-10
.
Bus B In 2
Figure 4-10 Audio Output 2 From Third NSM Router to Bus B In 2
When using the IOCON-BO-VAB breakout module, audio output 1 from the third NSM router must be connected to Input Bus A2 on the breakout module, as indicated in
Table
2-9
on page 54.
Audio output 2 from the third NSM must be connected to Input Bus B2 on the breakout module, as indicated in
Table 2-9
on page 54.
Note: System configurations for NEO routers start on page 62. System configurations for
Platinum routers start on page 91.
This section describes the connections that are required in some typical configurations involving Panacea external routers. The following Panacea router configurations are described in this section:
IconMaster system with external Panacea video router and optional ICONM-BO-V module
IconMaster System with external Panacea video router and optional ICONM-BO-V module with optional SPT-LSERIAL serial protocol translator
74
Chapter 4
Router Connections
IconMaster system with external Panacea clean quiet video router and optional
ICONM-BO-V module with optional SPT-LSERIAL serial protocol translator
IconMaster system with external Panacea (single channel) audio and video routers and optional ICONM-BO-VAC module with optional SPT-LSERIAL serial protocol translator
IconMaster system with external Panacea (two channel) audio and video routers and optional ICONM-BO-VAC module with optional SPT-LSERIAL serial protocol translator
This section describes the connections that are required in a typical configurations involving an IconMaster system with a Panacea video router and an optional breakout module.
on page 75 shows a detailed illustration of this process.
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules
Installation, Configuration, and Operation Manual for detailed information.
When using the ICONM-BO-V breakout module, the serial port of the Panacea router must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
.
RS-232/422-E Port
Figure 4-11 RS-232/422-E Port on the ICONM-BO-V Breakout Module
1
On the Panacea back module, connect a maximum of 16 video inputs to the BNC connections labeled Input 1 to Input 16.
2
Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3
Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4
Connect your station reference to the Sync connection of the Panacea back module.
5
Terminate one of the XY BNC connectors on the Panacea router.
6
Connect the serial port of the Panacea router to Serial Port E in the Multi Function I/O connector on the MKE-3901.
This can be done in either of these two ways.
Direct connection
ICONM-BO-V breakout module connection
IconMaster
Installation and Configuration Manual
75
7
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
Figure 4-12 IconMaster System with External Panacea Video Router and Optional ICONM-BO-V Module
8
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
76
Chapter 4
Router Connections
9
On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note: If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same network.
10
Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through
Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
11
Power up the system.
This section describes the connections that are required in a typical configurations involving an IconMaster system with a Panacea video router, an optional breakout module, and an optional SPT-LSERIAL serial protocol translator.
illustration of this process.
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules
Installation, Configuration, and Operation Manual for detailed information.
When using the ICONM-BO-V breakout module, the serial port of the Panacea router must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
.
RS-232/422-E Port
Figure 4-13 RS-232/422-E Port on the ICONM-BO-V Breakout Module
1
On the Panacea back module, connect a maximum of 16 video inputs to the BNC connections labeled Input 1 to Input 16.
2
Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3
Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4
Connect your station reference to the Sync connection of the Panacea back module.
5
Terminate one of the XY BNC connectors on the Panacea router.
IconMaster
Installation and Configuration Manual
77
6
Connect the serial port of the Panacea router to Serial Port E in the Multi Function I/O connector on the MKE-3901.
This can be done in either of these two ways.
Direct connection
ICONM-BO-V breakout module connection
Figure 4-14 IconMaster System with External Panacea Video Router and Optional ICONM-BO-V Module with
Optional SPT-LSERIAL
78
Chapter 4
Router Connections
7
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9
On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note: If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10
Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through
Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
11
Power up the system.
The IconMaster is installed in the control line, as shown in the example in
The maximum allowable distance for each segment of the X-Y coaxial cable run is
2,000 ft (609 m).
The maximum length for each RS-232 segment is 50 ft (15 m).
The maximum length for each RS-422 segment is 2,000 ft (609 m).
Up to 64 additional serial ports may be added.
on page 79 shows the connector pin assignments on both ends of the
connection (the cable wiring description is shown between the connectors).
IconMaster
Installation and Configuration Manual
79
Figure 4-15 Cable Wiring Details for IconMaster
Table 4-1 Power Requirements for SPT-LSERIAL
PD9200PL6A Adaptor Description
Locations with 110-127 volt electrical systems should use the PD9200PL6A adaptor*
Input voltage: 120 VAC, 60 Hz
Input current: 60 mA max.
Output voltage: 9.0 VDC
Output current: 200 mA
Output connector: 5.5 mm x 2.5 mm female barrel power plug with positive center
PD9300EPL6A Adaptor Description
80
Chapter 4
Router Connections
Table 4-1 Power Requirements for SPT-LSERIAL
PD9200PL6A Adaptor Description
Locations with 220-240 volt electrical systems should use the PD9300EPL6A adaptor
*
Input voltage: 230 VAC, 5 0Hz
Input current: 40 mA max
Output voltage: 9.0 VDC
Output current: 30 0mA
Output connector: 5.5 mm x 2.5 mm female barrel power plug with positive center
* If you did not receive the correct adaptor for your electrical system, please contact your Customer Service representative.
This section describes the connections that are required in a typical configuration involving an IconMaster system with a Panacea clean/quiet switch router, an optional breakout module, and an optional SPT-LSERIAL serial protocol translator.
shows a detailed illustration of this process.
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules
Installation, Configuration, and Operation Manual for detailed information.
When using the ICONM-BO-V breakout module, the serial port of the Panacea router must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
.
RS-232/422-E Port
Figure 4-16 RS-232/422-E Port on the ICONM-BO-V Breakout Module
1
On the Panacea back module, connect a maximum of 16 video inputs to the BNC connections labeled Input 1 to Input 16.
2
Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
IconMaster
Installation and Configuration Manual
81
3
Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4
Connect your station reference to the Sync connection of the Panacea back module.
5
Terminate one of the XY BNC connectors on the Panacea router.
6
Connect the serial port of the Panacea router to Serial Port E in the Multi Function I/O connector on the MKE-3901.
82
Chapter 4
Router Connections
This can be done in either of these two ways.
Direct connection
ICONM-BO-V breakout module connection
Figure 4-17 IconMaster System with External Panacea Clean/Quiet Switch Video Router, Optional ICONM-BO-V
Module and Optional SPT-LSERIAL
IconMaster
Installation and Configuration Manual
83
7
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9
On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note: If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10
Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through
Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
11
Power up the system.
The IconMaster is installed in the control line, as shown in the example in
The maximum allowable distance for each segment of the X-Y coaxial cable run is
2,000 ft (609 m).
The maximum length for each RS-232 segment is 50 ft (15 m).
The maximum length for each RS-422 segment is 2,000 ft (609 m).
Up to 64 additional serial ports may be added.
on page 79 shows the connector pin assignments on both ends of the
connection (the cable wiring description is shown between the connectors).
on page 79 shows the power requirements for the SPT-LSERIAL adaptors.
This section describes the connections that are required in a typical configuration involving an IconMaster system with a single channel Panacea audio and video routers, an optional breakout module, and an optional SPT-LSERIAL serial protocol translator.
on page 85 shows a detailed illustration of this process.
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules
Installation, Configuration, and Operation Manual for detailed information.
84
Chapter 4
Router Connections
When using the ICONM-BO-VAC breakout module and multiple Panacea routers
(multi-level), the audio output 1 from the level 1 Panacea router must be connected to Bus
A In 1 on the breakout module as indicated in
Bus A In 1
Figure 4-18 Audio 1, Level 1 Panacea Connection to ICONM-BO-VAC
Likewise, the audio output 2 from the level 1 Panacea router must be connected to Bus B
In 1 on the breakout module as indicated in
Figure 4-19
.
Bus B In 1
Figure 4-19 Audio 2, Level 1 Panacea Connection to ICONM-BO-VAC
IconMaster
Installation and Configuration Manual
85
Figure 4-20 IconMaster System with External Panacea (Single Channel) Audio and Video Routers, Optional
ICONM-BO-VAC Module, Optional SPT-LSERIAL
86
Chapter 4
Router Connections
Audio output 1 from the level 2 Panacea router must be connected to Bus A In 2 on the breakout module, as indicated in
Bus A In 2
Figure 4-21 Audio 1, Level 2 Panacea Connection to ICONM-BO-VAC
Audio output 1 from the level 2 Panacea router must be connected to Bus B In 2 on the breakout module, as indicated in
Bus B In 2
Figure 4-22 Audio 2, Level 2 Panacea Connection to ICONM-BO-VAC
When using the ICON-BO-VAB breakout module and a Panacea router (single level), audio output 1 from the Panacea router must be connected to Input Bus A1 on the breakout module as indicated in
Likewise, audio output 2 from the Panacea router must be connected to Input Bus B1 on the breakout module as indicated in
Audio output 1 from the level 2 Panacea router must be connected to Input Bus A2 on the breakout module as indicated in
Audio output 2 from the level 2 Panacea router must be connected to Input Bus B2 on the breakout module as indicated in
1
On the Panacea back module, connect a maximum of 16 video inputs to the BNC connections labeled Input 1 to Input 16.
2
Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3
Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4
Connect your station reference to the Sync connection of the Panacea back module.
5
Terminate one of the XY BNC connectors on the Panacea router.
6
Connect the serial port of the Panacea router to Serial Port E in the Multi Function I/O connector on the MKE-3901. This can be done by direct connection or via the ICONM-BO-V breakout module connection.
7
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9
On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
IconMaster
Installation and Configuration Manual
87
Note: If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10
Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through
Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
11
Power up the system.
The IconMaster is installed in the control line, as shown in the example in
The maximum allowable distance for each segment of the X-Y coaxial cable run is
2,000 ft (609 m).
The maximum length for each RS-232 segment is 50 ft (15 m).
The maximum length for each RS-422 segment is 2,000 ft (609 m).
Up to 64 additional serial ports may be added.
on page 79 shows the connector pin assignments on both ends of the
connection (the cable wiring description is shown between the connectors).
on page 79 shows the power requirements for the SPT-LSERIAL adaptors.
This section describes the connections that are required in a typical configuration involving an IconMaster system with two channel Panacea audio and video routers, an optional breakout module, and an optional SPT-LSERIAL serial protocol translator.
on page 89 shows a detailed illustration of this process.
Before you can make any connections to an IconMaster, the Panacea router must already be configured as desired. If your Panacea router is already operational, you do not need to configure it. If, however, your Panacea router is not already operational, you must install and configure it as desired for your facility. See the Panacea Series Frame and Modules
Installation, Configuration, and Operation Manual for detailed information.
88
Chapter 4
Router Connections
When using the ICONM-BO-VAC breakout module and multiple Panacea routers
(multi-level), the audio output 1 from the level 1 Panacea router must be connected to Bus
A In 1 on the breakout module as indicated in
Bus A In 1
Figure 4-23 Audio 1, Level 1 Panacea Connection to ICONM-BO-VAC
Likewise, the audio output 2 from the level 1 Panacea router must be connected to Bus B
In 1 on the breakout module as indicated in
Figure 4-24
.
Bus B In 1
Figure 4-24 Audio 2, Level 1 Panacea Connection to ICONM-BO-VAC
IconMaster
Installation and Configuration Manual
89
Figure 4-25 IconMaster System with External Panacea (Two Channel) Audio and Video Routers, Optional
ICONM-BO-VAC Module, Optional SPT-LSERIAL
90
Chapter 4
Router Connections
Audio output 1 from the level 2 Panacea router must be connected to Bus A In 2 on the breakout module, as indicated in
Bus A In 2
Figure 4-26 Audio 1, Level 2 Panacea Connection to ICONM-BO-VAC
Audio output 1 from the level 2 Panacea router must be connected to Bus B In 2 on the breakout module, as indicated in
Bus B In 2
Figure 4-27 Audio 2, Level 2 Panacea Connection to ICONM-BO-VAC
Audio outputs 3 and 4 from the Panacea level 3 and 4 routers connect to Bus A and B In 3 and 4, respectively.
When using the ICON-BO-VAB breakout module and a Panacea router (single level), audio output 1 from the Panacea router must be connected to Input Bus A1 on the breakout module as indicated in
Likewise, audio output 2 from the Panacea router must be connected to Input Bus B1 on the breakout module as indicated in
Audio output 1 from the level 2 Panacea router must be connected to Input Bus A2 on the breakout module as indicated in
Audio output 2 from the level 2 Panacea router must be connected to Input Bus B2 on the breakout module as indicated in
Audio outputs 3 and 4 from the Panacea level 3 and 4 routers connect to Input Bus A and
B, 3 and 4, respectively.
1
On the Panacea back module, connect a maximum of 16 video inputs to the BNC connections labeled Input 1 to Input 16.
2
Connect Output 1 on the Panacea to Input Bus A on the MKE-3901.
3
Connect Output 2 on the Panacea to Input Bus B on the MKE-3901.
4
Connect your station reference to the Sync connection of the Panacea back module.
5
Terminate one of the XY BNC connectors on the Panacea router.
6
Connect the serial port of the Panacea router to Serial Port E in the Multi Function I/O connector on the MKE-3901.
IconMaster
Installation and Configuration Manual
91
This can be done by direct connection or via the ICONM-BO-V breakout module connection.
7
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
8
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
9
On the MKE-3901 back module, supply Squeeze Bkgd by an external router.
Note: If you are connecting Ethernet 1 to a switch, the IconMaster control panel must be connected to the same switch.
10
Connect the two Ethernet ports as follows:
Ethernet 1 (connection for MKE-3901 control) to a switch using a straight-through
Ethernet cable
Ethernet 2 (two connection options for MGI-3903 control and logo download)
To the same switch as Ethernet 1 using a normal Ethernet cable
To a dedicated switch used for the MGI functionality using a normal Ethernet cable
11
Power up the system.
The IconMaster is installed in the control line, as shown in the example in
The maximum allowable distance for each segment of the X-Y coaxial cable run is
2,000 ft (609 m).
The maximum length for each RS-232 segment is 50 ft (15 m).
The maximum length for each RS-422 segment is 2,000 ft (609 m).
Up to 64 additional serial ports may be added.
on page 79 shows the connector pin assignments on both ends of the
connection (the cable wiring description is shown between the connectors).
on page 79 shows the power requirements for the SPT-LSERIAL adaptors.
Note: System configurations for NEO routers start on page 62. System configurations for
Panacea routers start on page 62.
This section describes the connections that are required in some typical configurations involving Platinum external routers. The following Platinum router configurations are described in this section:
IconMaster System, External Platinum Video Router, Optional ICONM-BO-V Module
Sample Configuration 2: IconMaster System, External Platinum Video Router, Optional
HView SX Hybrid multiviewer, Optional JLCooper eBOX, Optional ICONM-BO-V Module
92
Chapter 4
Router Connections
This section describes the connections that are required in a typical configurations involving
Platinum external routers.
on page 93 shows a detailed illustration of this
process.
Before you can make any connections to an IconMaster, the Platinum router must already be configured as desired. If your Platinum router is already operational, you do not need to configure it. If, however, your Platinum router is not already operational, you must install and configure it as desired for your facility. See the Platinum Series Frames and Modules
Installation, Configuration, and Operation Manual for detailed information.
On your Platinum router configuration, make sure that you set the video and audio to different levels. For example, if you set the video level to “0,” set the audio level to “1” or higher.
1
On the Platinum router, connect the inputs to the input BNC connections on the appropriate Platinum modules.
2
Terminate the loop-thru (XY) BNC connectors on the communications back panel (PT-CBP).
3
Connect the first desired output on the PT-CBP to Input Bus A on the MKE-3901.
4
Connect second desired output on the PT-CBP to Input Bus B on the MKE-3901.
5
On the PT-CBP, connect the station reference to one connector on an available Sync connection.
6
On the MKE-3901 back module, connect the signal Squeeze Bkgd input to an output on the PT-CBP.
Note: The Platinum router serial port baud rate must be set to 38400. IconMaster can control the Platinum over Ethernet.
7
Connect an available serial port (SERIAL1 or SERIAL2) on the PT-CBP to Serial Port E in the
Multi Function I/O connector on the MKE-3901. This can be done by direct connection or by
ICONM-BO-V breakout module connection. When using the ICONM-BO-V breakout module, either serial port of the PT-CBP must be connected to the RS-232/422-A, -B, or -E
IconMaster
Installation and Configuration Manual
93 port on the breakout module as indicated in
Figure 4-29
on page 94.
Figure 4-28 IconMaster System with External Platinum Router Using Serial Control and Optional ICONM-BO-V
Module
94
Chapter 4
Router Connections
RS-232/422-E Port
Figure 4-29 RS-232/422-E Port on the ICONM-BO-V Breakout Module
8
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
9
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
Note: If you are connecting Ethernet 1 to a network hub/switch, the IconMaster control panel must be connected to the same switch.
10
On the MKE-3901 back module, connect the Ethernet 1 connection for MKE-3901 control to a network hub/switch using a straight-through Ethernet cable.
11
On the MGI-3903 back module, two Ethernet connection options for MGI-3903 control and logo download as follows:
To the same network/hub as Ethernet 1 using a normal Ethernet cable.
To a dedicated switch used for the MGI functionality using a normal Ethernet cable.
12
Power up the system.
This section describes the connections that are required in a typical configurations involving
Platinum external routers.
on page 96 shows a detailed illustration of this
process.
Before you can make any connections to an IconMaster, the HView SX Hybrid multiviewer output module must already be installed and configured in the Platinum frame. See the
HView SX Hybrid Multiviewer Installation, Configuration, and Operation Manual and the
HView SX Hybrid Layout Designer User Guide for detailed information.
You will need to configure some settings for the multiviewer in your Layout Designer software before you can use the eBOX with HView SX Hybrid.
1
Right click on the HView SX Hybrid device in the Multiviewers window of Layout Designer.
2
Select Advanced Configuration.
3
Select the External Devices tab.
4
Select the desired HView SX Hybrid’s “-1” configuration.
5
Under Type, select TSL Protocol.
6
Under Port, select TCP/IP.
7
Under IP, enter the IP address and port.
The default IP is 192.168.254.102.
IconMaster
Installation and Configuration Manual
95
The default port is 23.
8
Click Add.
9
Click Done.
Before you can make any connections to an IconMaster, the Platinum router must already be configured as desired. If your Platinum router is already operational, you do not need to configure it. If, however, your Platinum router is not already operational, you must install and configure it as desired for your facility. See the Platinum Series Frames and Modules
Installation, Configuration, and Operation Manual for detailed information.
96
Chapter 4
Router Connections
On your Platinum router configuration, make sure that you set the video and audio to different levels. For example, if you set the video level to “0,” set the audio level to “1” or higher.
Figure 4-30 IconMaster System with External Platinum Router Using Ethernet Control, HView SX Hybrid, eBOX, and Optional ICONM-BO-V Module
IconMaster
Installation and Configuration Manual
97
Before you can make any connections to an IconMaster, the JLCooper eBOX must already be configuredto work with your multiviewer. For information about configuring your e-BOX, see your JLCooper eBOX documentation.
1
On the Platinum router, connect the inputs to the input BNC connections on the HView SX
Hybrid modules.
2
Terminate the loop-thru (XY) BNC connectors on the communications back panel (PT-CBP).
3
Connect the first desired output on the PT-CBP to Input Bus A on the MKE-3901.
4
Connect second desired output on the PT-CBP to Input Bus B on the MKE-3901.
5
On the PT-CBP, connect the station reference to one connector on an available Sync connection.
6
On the MKE-3901 back module, connect the signal Squeeze Bkgd input to the output on the PT-CBP.
Note: The Platinum router serial port baud rate must be set to 38400.
7
Connect an available serial port (SERIAL1 or SERIAL2) on the PT-CBP to Serial Port E in the
Multi Function I/O connector on the MKE-3901. This can be done by direct connection or by
ICONM-BO-V breakout module connection. When using the ICONM-BO-V breakout module, either serial port of the PT-CBP must be connected to the RS-232/422-A, -B, or -E port on the breakout module as indicated in
RS-232/422-E Port
Figure 4-31 RS-232/422-E Port on the ICONM-BO-V Breakout Module
8
On the MKE-3901 back module, connect the Key 1 input source to Key 1 and Fill 1 as appropriate.
9
On the MKE-3901 back module, connect the Key 2 input source to Key 2 and Fill 2 as appropriate.
Note: If you are connecting Ethernet 1 to a network hub/switch, the IconMaster control panel must be connected to the same network.
10
On the MKE-3901 back module, connect the Ethernet 1 connection for MKE-3901 control to a network hub/switch using a straight-through Ethernet cable.
11
On the MGI-3903 back module, two Ethernet connection options for MGI-3903 control and logo download as follows:
To the same network/hub as Ethernet 1 using a normal Ethernet cable.
To a dedicated switch used for the MGI functionality using a normal Ethernet cable.
12
Power up the system.
98
Chapter 4
Router Connections
Advertisement
Master Control Switcher
Intuitive user-friendly interface
High reliability
High performance
Versatile control options
The Nexio IconMaster is a Master Control Switcher that provides a variety of control options for video and audio applications.
The IconMaster features an intuitive, user-friendly interface, high reliability, high performance and versatile control options.
The IconMaster can be used for a variety of applications, including live broadcast production, post production editing, corporate video production, educational video production, video surveillance and control room applications.
What types of keyers are supported?
The device supports internal (logo) and external keyers.
Where are the keyer configuration options located?
Keyer settings are in the IconMaster Configuration Utility (ICU), under 'Keyer Settings' in the 'Configuring IconMaster' menu (Chapter 10).
Login to continue