Configuring IP Addresses. Imagine communications IconMaster
Publicitate
Publicitate
5
Configuring IP Addresses
Setting the IP Address for the MKE-3901 Module
1
Press the left (Esc) button until the message MKE3901 appears on the VFD display.
2
Press the right (Enter) button.
3
Use the toggle switch (Nav) to scroll through the parameter list until Status is highlighted.
4
Press the right (Enter) button.
5
Use the toggle switch (Nav) to scroll through the parameter list until Other is highlighted.
6
Press the right (Enter) button.
7
Use the toggle switch (Nav) to scroll through the parameter list until IP_Address is highlighted.
8
Press the right (Enter) button.
9
Continue pressing the right (Enter) button until the cursor is under the digit you want to change.
10
Use the toggle switch (Nav) to change the digit.
11
Press the right (Enter) button to move to the next digit.
12
Repeat the previous three steps until you have changed the IP address.
13
Press the right (Enter) button until the cursor is under the space at the end of the IP address.
14
Press the left (Esc) button to accept the change.
Setting the IP Address for the MGI-3903 Module
1
Press the left (Esc) button until the message MGI-3903-R appears on the VFD display.
2
Press the right (Enter) button.
3
Use the toggle switch (NAV) to scroll through the parameter list until IP_Address is highlighted.
4
Press the right (Enter) button.
5
Continue pressing the right (Enter) button until the cursor is under the digit you want to change.
6
Use the toggle switch (Nav) to change the digit.
7
Press the right (Enter) button to move to the next digit.
8
Repeat the previous three steps until you have changed the IP address.
9
Press the right (Enter) button until the cursor is under the space at the end of the IP address.
99
100
Chapter 5
Configuring IP Addresses
10
Press the left (Esc) button to accept the change.
Changing the Control Panel IP Address
1
To access the service menu:
On an ICONM-RCP, simultaneously press all four LCD buttons in the center Parameter
Control Cluster
On an ICONM-RCP16 panel, press the right control knob
2
Turn the left scroll knob until the PNL IP ADDR parameter appears.
Reading from left to right, you will see a display of the control panel’s current IP address.
3
Select the button that contains the IP address component that you want to change, and then turn the right scroll knob to change the number on that button.
4
After you enter the last digit of the IP Address, press the right knob to save the new IP
Address.
5
When finished, turn the left scroll knob until the PUSH EXIT parameter appears.
Set the IP Address for the 3901RES-E Module
To use CCS-P control and monitoring of your IconMaster master control switcher, Navigator and NUCLEUS operate through the frame’s optional 3901RES-E module.
To change the resource module network settings, at least one of the processing modules in the frame must support the Frame IP feature.
Note: The IRB-3901, GPI-3901, and MGI-3901 NEO modules do not support Frame IP.
Some older NEO modules that have not been upgraded also do not support this feature.
To configure the IP address for this module, follow these steps:
1
Using the card-edge of a NEO processing module in the same frame as the resource module, scroll down and then select the Setup menu at the end of the parameter list.
2
Select Frame IP, and then press the Enter button.
3
Select IP Address, and then press the Enter button.
The card-edge screen shows the current IP Address of the active resource module.
If the message Not Supported appears, correct the problem by ensuring that the active resource module’s SW2 DIP 8 is in the down position.
4
Using the Enter button, scroll to the digit in the IP Address.
5
Press the toggle switch up or down to change the IP number, and then scroll past the end of the number to accept the change.
The following tips will help you enter an IP address:
To backspace from the selected number in the IP to the one before it, scroll using the
Nav+/Nav- until you reach the back arrow ( ), and then press the Enter button.
IconMaster
Installation and Configuration Manual
101
Delete the selected number in the IP by scrolling using the
Nav+/Nav- switch until the delete character ( X ) is displayed, and then press the
Enter button.
(The delete character is located after the number “0”)
Use Nav+ (up) to scroll up through numbers, increasing the selected number.
Use Nav- (down) to scroll down through numbers, decreasing the selected number.
6
Press the Escape/Exit button, and then repeat the number changing process for the
Subnet and Gateway if necessary.
7
Press the Escape/Exit button twice to send the new IP Address to the resource module.
8
Reboot the resource module by pulling it out of its slot and reinserting it.
9
Confirm the resource module’s corrected IP Address by again using the card edge to verify the IP Address, Subnet, and Gateway IP settings. Then ping the resource module via the PC, as described in the following steps:
a
Click Start, point to Programs > Accessories and then click Command Prompt to open the Command Prompt window on the PC.
b
After the command prompt, type the following message, and then press ENTER: ping 192.168.248.50 (or the actual IP Address of your resource module)
The message should reply back. If the ping does not work, see
Initializing
IconMaster
Once you have completed the system wiring, the following settings are required:
Network settings
Operating standard
System timing
Network
Settings
The default IP address will function correctly in a “one frame and one panel” configuration if both frame and panel are connected to the same switch that is not connected to a network server or router.
If you have changed the IP address on the card edge of the MKE-3901 module, you must
make the same change in the Network dialog box in the ICU software (see page 176).
To change the network settings of the IconMaster control panel, refer to the Panel Network
Configuration dialog box in ICU software (see page 185). Alternatively, you can use the
Service Menu change the IP address of the IconMaster control panel on the panel itself.
Refer to the IconMaster Functional Operation and Configuration Manual for more information.
Operating
Standard
To change the operating standard, use the Genlock and Standards dialog box in the ICU
Note: When changing between HD operating standards (for example, from 1080I to 720P), you must repower the IconMaster.
102
Chapter 5
Configuring IP Addresses
System
Timing
To make changes to the IconMaster timing, use the Genlock and Standards dialog box in