advertisement
![E7-2 Specifications. Calix E7-2 | Manualzz E7-2 Specifications. Calix E7-2 | Manualzz](http://s3.manualzz.com/store/data/030896977_1-cc2b40e2192ac0275042e9ecbc74b39f-360x466.png)
54
E7-2 Specifications
Specifications for the Calix E7-2 follow:
Dimensions
Chassis
Weight
E7-2 chassis only
E7-2 chassis with FTA
E7-2 chassis with FTA + 2 line cards
E7-2 chassis with FTA2
E7-2 chassis with FTA2 + 2 line cards
Mounting
Width
Depth
Orientation
Electrical
Power input
Fusing
Environmental
Operating range
Storage range
Heat dissipation (with 2 line cards)
Fan module cooling capacity
Alarming
Compliance
Compatibility, Electrical Safety, and Electromagnetic emissions criteria
1.7 (H) x 17.5 (W) x 11.45 (D) inches
4.3 (H) x 44.5 (W) x 29.1 (D) cm
5.9 lbs (2.7 kg)
7.4 lbs (3.4 kg)
11.5 lbs (5.2 kg)
7.0 lbs (3.2 kg)
11.1 lbs (5.0 kg)
19-inch (48.26-cm) and 23-inch (58.42-cm) racks
Front (flush) mounting
Center (projection) mounting, 5 depth options
Horizontal and vertical mounting supported
-48 VDC redundant battery feeds (A and B)
-42.5 VDC to -72 VDC input range
7.5 Amps maximum (A and B)
-40º C to +65º C (-40º F to +149º F)
Humidity: 10 to 95% (non-condensing)
Altitude: up to 10,000 feet (3049 m)
-40º C to +85º C (-40º F to +185º F)
Humidity: 5 to 95%
Up to 185 Watts maximum
FTA: 200 Watts, 108 CFM; (2) automatic variable fan speed operations
FTA2: 200 Watts, 115 CFM; (4) automatic variable fan speed operations
Note: FTA2 requires E7 release 2.2 or higher to support four fan speeds. In releases prior to 2.2, FTA2 supports two fan speeds.
8 user definable alarm inputs (7 inputs, 1 output)
UL/cUL 60950
European Union EN 60950 (CE Mark)
EIA-310D
FCC Part 15 Class A
Network Equipment-Building System (NEBS) Level 3: Telcordia
GR-63-CORE
Telcordia GR-1089-CORE
Telcordia GR-3028-CORE
ETSI EN 300 019, ETSI 300 386
Proprietary Information: Not for use or disclosure except by written agreement with Calix.
© Calix. All Rights Reserved.
advertisement
Related manuals
advertisement
Table of contents
- 8 Introducing the Calix E
- 10 Product Dimensions
- 12 Installation Guidelines
- 13 Safety Recommendations and Notices
- 14 Required Items
- 16 Preparations Before You Begin
- 18 Installing the E7-2 Chassis
- 21 Grounding the Chassis
- 23 Connecting DC Power
- 24 Installing the Fan Module
- 26 Installing E7-2 Line Cards
- 28 Installing a Fiber Guide
- 31 Installing an Intake/Exhaust System
- 34 Connecting the E7-2 Management Interfaces
- 34 Connecting to the Ethernet Management Ports
- 36 Connecting to the RS-232 Serial Port
- 37 Wiring the External Alarm and Timing Interfaces
- 37 Wiring External Alarms
- 39 Wiring the BITS Timing Interface
- 41 Connecting the E7-2 Line Interfaces
- 42 Installing Pluggable Transceiver Modules
- 43 Connecting Fibers
- 44 Connecting to the Copper Access Interfaces
- 48 Replacing Pluggable Transceiver Modules
- 49 Replacing an E7-2 Line Card
- 50 Replacing the Fan Module
- 51 Fan Filter Maintenance
- 54 E7-2 Specifications
- 55 E7-2 LED Behavior
- 57 RS-232 Serial Port Pins
- 58 RJ-21 Pin Assignments
- 60 Fiber Handling Techniques