E7-2 Specifications

Specifications for the Calix E7-2 follow:

Dimensions

Chassis

Weight

E7-2 chassis only

E7-2 chassis with FTA

E7-2 chassis with FTA + 2 line cards

E7-2 chassis with FTA2

E7-2 chassis with FTA2 + 2 line cards

Mounting

Width

Depth

Orientation

Electrical

Power input

Fusing

Environmental

Operating range

Storage range

Heat dissipation (with 2 line cards)

Fan module cooling capacity

Alarming

Compliance

Compatibility, Electrical Safety, and Electromagnetic emissions criteria

1.7 (H) x 17.5 (W) x 11.45 (D) inches

4.3 (H) x 44.5 (W) x 29.1 (D) cm

5.9 lbs (2.7 kg)

7.4 lbs (3.4 kg)

11.5 lbs (5.2 kg)

7.0 lbs (3.2 kg)

11.1 lbs (5.0 kg)

19-inch (48.26-cm) and 23-inch (58.42-cm) racks

Front (flush) mounting

Center (projection) mounting, 5 depth options

Horizontal and vertical mounting supported

-48 VDC redundant battery feeds (A and B)

-42.5 VDC to -72 VDC input range

7.5 Amps maximum (A and B)

-40º C to +65º C (-40º F to +149º F)

Humidity: 10 to 95% (non-condensing)

Altitude: up to 10,000 feet (3049 m)

-40º C to +85º C (-40º F to +185º F)

Humidity: 5 to 95%

Up to 185 Watts maximum

FTA: 200 Watts, 108 CFM; (2) automatic variable fan speed operations

FTA2: 200 Watts, 115 CFM; (4) automatic variable fan speed operations

Note: FTA2 requires E7 release 2.2 or higher to support four fan speeds. In releases prior to 2.2, FTA2 supports two fan speeds.

8 user definable alarm inputs (7 inputs, 1 output)

UL/cUL 60950

European Union EN 60950 (CE Mark)

EIA-310D

FCC Part 15 Class A

Network Equipment-Building System (NEBS) Level 3: Telcordia

GR-63-CORE

Telcordia GR-1089-CORE

Telcordia GR-3028-CORE

ETSI EN 300 019, ETSI 300 386