SECTION 3: Programming the 7847i/7847i-E. Honeywell AlarmNet 7847i-E, AlarmNet 7847i
Реклама
Реклама
7847i/7847i-E Installation and Setup Guide
Wiring the 7847i/7847i-E
Unshielded, 22 AWG cable is recommended for 7847i/7847i-E power/data wires.
Wiring for ECP, 4204 and Two-4204 Modes
Most Honeywell ADEMCO control panels support LRR-ECP data communication, (e.g.,
VISTA-10P, VISTA-15P, VISTA-20P, LynxR-I, VISTA-128BP/250BP and
VISTA-128FBP/250FP). However, there are some panels that do not. Check the Installation and Setup Guide for the control panel you are using to see if it supports ECP communication.
Connect the 7847i/7847i-E to a compatible Honeywell VISTA control panel's ECP terminals, in parallel with keypads and other peripheral devices, VIP module, etc. Wire length/gauge limitations are the same for the module as they are for keypads and other peripheral devices.
To wire the module for ECP communication, see Figure 3 and do the following:
Table 1. Wiring connections for ECP or 4204 modes
7847i/7847i-E Control
Terminal 3 V+
Terminal 4 GND
+12 V Aux
Ground
Terminal 5 Data In Data Out
Terminal 6 Data Out Data In
+12 V
GND
DATA OUT
DATA IN
RED
BLK
YEL
GRN
TB1
3
V+
4
GND
5 ECP DATA IN
6
ECP DATA OUT
CONTROL PANEL
7847i / 7847i-E
Figure 3. Wiring a Vista for ECP Mode or 4204 Modes
7847i-E-019-V0
To install a 7847i/7847i-E with a LynxR-I Security System, wire the devices as shown in
Figure 4 below. Refer to LynxR-I Installation and Setup Guide.
2-2
Section 2: Mounting and Wiring
4-WIRE CABLE (N4632-4)
RED
TB1
3 V+
BLK
YEL
GRN
4
GND
5
ECP DATA IN
6
ECP DATA OUT
LYNXR-I CONTROL PANEL 7847i / 7847i-E
Figure 4. Wiring a LynxR-I for ECP Mode
Wiring for Zone Trigger Mode
To trip the zone on the 7847i/7847i-E in V+ trigger mode, the positive triggering voltage from the control panel must be within 2.0V-14V.
Trigger levels above this range may cause permanent damage to the unit.
Trigger levels below this range result in unreliable operation.
To trip the zone on the 7847i/7847i-E in V- trigger mode, the negative triggering voltage must be less than 1.0V.
NOTE: LynxR and LynxR-EN have a designated trigger for V- trigger.
Connect a wire from the triggering source (bell output, voltage trigger, etc.) of the control panel to the zone input of the module, and connect a common ground between the module and control panel.
UL
The configurations shown in Figures 5a and 5b have not been evaluated by UL.
Examples of zone connections are shown below:
+12 V
GND
BELL (+)
TB1
3 V+
4
GND
5
ZONE INPUT Z1/Z2
( )
(+)
CONTROL PANEL
7847i / 7847i-E
Figure 5a. Wiring the 7847i/7847i-E Zone 1 Input for a Positive (+) Triggered Bell Output
+12 V
GND
BELL ( )
TB1
3 V+
4 GND
5 ZONE INPUT Z1/Z2
( ) (+)
CONTROL PANEL
7847i / 7847i-E
Figure 5b. Wiring the 7847i/7847i-E Zone 1 Input for a Ground (-) Triggered Bell Output
2-3
7847i/7847i-E Installation and Setup Guide
TB1
1
NOT USED
2
NOT USED
9
LRR / AAV
TRIGGER
8
LYNXR/LYNXR-EN
CONTROL PANEL
2K EOL
RESISTOR
4
GND
5
ZONE INPUT Z1/Z2
7847i / 7847i-E
Figure 6. Wiring the 7847i/7847i-E Zone 1 Input to a LynxR Trigger Output
2K EOL
RESISTOR
N.O.
TB1
1 NOT USED
2
NOT USED
3
ECP (+) VOLTAGE INPUT
4 GND
5
ZONE INPUT Z1/Z2
N.C.
7847i / 7847i-E
Figure 7. Wiring the 7847i/7847i-E Zone 1 Input for EOL Supervised N.O./N.C. Triggers
Power Connections and Options
Primary power for the 7847i/7847i-E is provided by the auxiliary power output of the control panel 9.6V –13.8V, typical, or other external power source.
When calculating the total load on the auxiliary power output of the control panel, 20mA must be budgeted for the 7847i/7847i-E. Under normal operating conditions, the unit will not pull more than 20mA; however, it will draw 75mA during a transmission.
Connect the wires from the (+) and (–) terminals of the DC power source to terminals V+ and
GND on TB1 of the 7847i/7847i-E. Observe Polarity!
If using an external power source, connect GND from power supply to GND of the control panel.
Ethernet Connections
UL
1. For UL installations, the Cat. 5 Ethernet connection between the 7847i/7847i-E and the router cannot exceed 12 feet with both the 7847i/7847i-E and the router located within the same room.
2. Use a Listed cable/DSL router suited for the application.
• Connect one end of the Ethernet cable (Category 5) to the 7847i-E's RJ45 Ethernet connector and the other end to the cable/DSL router.
2-4
Section 2: Mounting and Wiring
Xmit
Shift
Shift
BS / ESC
N / Y
/
7
S
Space
7720 PROGRAMMING TOOL
A B C
1 2 3
4
D
5
E
6
F
0
8
T
9
X
Enter
#
TO
ROUTER
TAMPER
SWITCH/
IB SERVICE
TB1
7720P
PROGRAM
CONNECTOR
STATUS
LED
DISPLAY
RJ45
ETHERNET
PORT
NETWORK
CONNECTIVITY
LED DISPLAY
MODE AND STATUS
LED DISPLAY
MODE AND STATUS
INDICATOR SWITCH
Figure 8. Ethernet Connections
7847i-E-016-V0
Initial Power-Up Sequence
Before connecting power, check that the following have been completed:
• Terminal block TB1 V+ and GND terminals are connected to the control panel's auxiliary power output: 12 VDC nominal.
• Power up the control panel.
Initially, all 7847i/7847i-E programming options are set to the factory default settings.
NOTE: Refer to
Appendix A for detailed information on LED functions.
2-5
7847i/7847i-E Installation and Setup Guide
2-6
S E C T I O N 3
Programming the 7847i/7847i-E
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
General Information
♦
ECP Mode Programming
♦
Alternative Modes (Zone Trigger, 4204 and
Two-4204)
♦
Alternative Mode Programming
♦
Exiting Programming Mode
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
General Information
To the control panel, the 7847i/7847i-E Internet/Intranet Communication Modules, when in ECP Mode, is treated as a long-range radio device.
The 7847i/7847i-E can be configured to deliver alarms via the Internet to an AlarmNet central station or via a Private LAN (7847i-E only) directly to a 7810iR-ent receiver . Both methods of communication are encrypted to ensure security. The 7847i and 7847i-E use 256bit AES (Rijndael) encryption (which is required for certain government installations).
The 7847i/7847i-E modules require an AlarmNet–i account, except when Private LAN is enabled on the 7847i-E. Obtain the account information from the central station prior to programming this module.
You can program a 7847i/7847i-E by one of the following methods:
• Through the AlarmNet Direct website
• Through use of a 7720P Programming Tool
• Through a programming mode in control panel, on panels that support this option (e.g., Vista-
128BP and FBP)
Using the AlarmNet Direct Website
To program the module via the website (if you are already signed up for this service), go to: https://services.alarmnet.com/AlarmNetDirect/userlogin.aspx.
If you are not signed up for this service, click on “Dealer Sign-Up".
Log in and follow the on-screen prompts.
Please have the following information available when programming the module:
1. Primary City ID (two-digit hexadecimal number)
2. Primary Central Station ID (two-digit number)
3. Primary Subscriber ID (four-digit number)
4. MAC ID and MAC CRC number (located on the outside of box and on label inside module)
After programming is complete, you must transfer the data to the module and the module must be registered. Refer to Section 4: Registration, for further instructions.
Using a 7720P Programming Tool
Connect the 7720P Programming Tool; refer to Figure 8 in Section 2. The 7847i and 7847i-E power the 7720P Programming Tool via the programming jack, and automatically senses the presence of the 7720P when it is plugged in.
3-1
7847i/7847i-E Installation and Setup Guide
Each key of the 7720P has two possible functions: a normal function and a Shift function.
To perform a normal key function, simply press the desired key. To perform a Shift function, press the [shift] key, and then press the appropriate key.
1/A
2/B
3/C
4/D
5/E
6/F
7/S
8/T
9/X
SPACE
The prompts in this document reflect use of the 7720P Programming Tool. Table 2 below lists each normal and shift key function.
KEY
Table 2. 7720P Normal and Shift Key (shift LED lit) Functions
NORMAL KEY FUNCTION SHIFT KEY FUNCTION
BS/ESC
↓/↑
N/Y
SHIFT
[BS]: Press to delete entry
[
↓]: Scroll down programming
[N]: Press for "NO" answer
[
[ESC]: Press to quit program mode; also can reset programming defaults*
↑]: Scroll up programming
[Y]: Press SHIFT-Y for "YES" answer
Press before pressing a SHIFT key function. Will light SHIFT LED. LED goes out once a key is pressed. Press again for each SHIFT function desired.
[1]: For entering the number 1
[2]: For entering the number 2
[3]: For entering the number 3
[A]: For entering letter A
[B]: For entering letter B
[C]: For entering letter C
[4]: For entering the number 4
[5]: For entering the number 5
[6]: For entering the number 6
[7]: For entering the number 7
[8]: For entering the number 8
[9]: For entering the number 9
[SPACE]: For scrolling option list
[D]: For entering letter D
[E]: For entering letter E
[F]: For entering letter F
[S]: For entering letter S
[T]: For entering letter T
[X]: For entering letter X
No SHIFT function
0 [0]: For entering the number 0 No SHIFT function
#/ENTER [#/ENTER]: Press to accept entries No SHIFT function
* Active only when the "Exit Programming Mode" prompt is displayed.
Using the Control Panel Programming Mode
Some control panels support programming of the 7847i/7847i-E through the control panel programming mode (e.g., Vista-128BP). If programming through the control panel, only the ECP Mode programming options are available. The "mode" questions will not be displayed, and the mode cannot be changed. For a description of key functions on the control panel keypad, and how they map to the 7720P Programming tool, refer to the control panel's Programming Guide.
Programming Conventions
Programming is accomplished by answering a series of prompts (questions). Most prompts require only a [Y]es or [N]o response, while others require a numerical response (ID numbers, etc.).
The current value is displayed on the second line in parentheses ( ). A "?" indicates an invalid entry.
Use the [ENTER] key to accept the current entry and proceed to the next prompt. If the current value is invalid, pressing [ENTER] re-displays the prompt; the next prompt is not displayed until a valid answer is entered.
Use the up/down arrow keys to scroll through the programming questions without changing any values. Press the [ESC] key to go to the end of the list of questions.
ECP Mode Programming
Press the [ENTER] key to begin programming.
NOTE: The central station can remotely block access to local device programming. If this has been done, the following prompt appears:
Access to Prog
Mode Denied
3-2
Section 3: Programming the 7847i/7847i-E
1
2
3
4
5
6
8
9
NOTE: The default programming values for ECP mode are listed in each prompt below.
PROMPTS
Strt Prog Mode?
(Y/N)_
Table 3: Programming a 7847i-E for ECP mode only.
ENTRY OPTIONS
[Y], [N]
DESCRIPTION
Enters programming mode.
Enter Password:
[0-9, A-F, N, S,
T, X, Y]
If a password has been previously assigned, this prompt appears.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
The next prompt appears.
Program Device?
(Y/N)_
[Y], [N]
Create Password?
(Y/N)_
Change Password?
(Y/N)_
[Y], [N]
[Y], [N]
To begin programming the module, press [Y] and go to
Prompt 9: "Device Mode."
To create a password if none has been assigned, press
[N] and go to Prompt 4: "Create Password."
To change an existing password, press [N] and go to
Prompt 5: "Change Password."
Passwords can be used to protect account and programming information.
If no password has been assigned, this prompt appears after pressing [N] at the "Program Device?" prompt.
If a password is desired, press [Y] and go to Prompt 6:
"Enter Password."
If a password has already been assigned, this prompt appears after pressing [N] at the "Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without entering a new one, answer [Y] to the "Change Password?" prompt, then press the [Enter] key when prompted for the new password and its confirmation.
Enter Password
[0-9, A-F, N, S,
T, X, Y]
This prompt is displayed if [Y] was pressed in Prompt 4 or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Verify Password
T, X, Y] If the password doesn't match the first entry, the following is displayed followed by the "Exit Prog.
Mode?" prompt:
Verify Not OK
PSWD not created
Exit Prog. Mode?
(Y/N)_
Device Mode
(ECP)_
[Y], [N]
[ESC]
• ECP
• Zone Triggers
• 4204 Emu
• Two 4204s
Otherwise, the "Exit Prog. Mode?" prompt is displayed directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in this section.
Press the [space] key to scroll through the modes of operation. Press [ENTER] to select ECP mode.
See Table 5 if programming other modes.
Important Information Regarding Multi-Mode Options
Users can receive email notification of system events by using the Multi-Mode feature. In ECP mode, this is accomplished through emulation of a 4204 relay module, or two 4204 relay modules. When “4204-Sourced” is selected, the user can be notified of up to four events, plus two additional events if using the optional communication device zones of 6 and 7. When “2-4204-Sourced” is selected, the user can be notified of up to eight system events.
3-3
7847i/7847i-E Installation and Setup Guide
The Multi-Mode address must match the address of a relay module enabled in the control panel (although you don’t actually connect a module). If using “2-4204-Sourced,” the address of the second module is automatically assigned the next device address after the first 4204. Make sure that address is also enabled in the control panel. Program outputs to trigger on system events the user would like to be notified of through Output Device (Relay) programming in the control panel. Outputs 1-4 on the first 4204 Device Address map to events 1-4. Outputs 1-4 on the second 4204
Device Address map to events 5-8.
For LynxR-I/ReadyGuardR-I series controls (when available), if "4204 Sourced" is selected, you must enable Multi-
Mode Address 6 or 7 in the control panel. If "2-4204" Sourced is selected, you must enable both (program field *86.
These events are configured at the AlarmNet Total Connect website at: https://services.alarmnet.com/TotalConnect
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central Station reporting of critical events (alarms, troubles, etc.).
NOTE: The Multi-Mode option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
10
Multi Mode
(Disabled)_
11
Multi Mode Addr
(12)_
• Disabled
• 4204 Sourced
• 2-4204 Sourced
[01-30]
DESCRIPTION
Enable if you want specific events sent by email to the user.
Select "4204 Sourced" to send up to four events or "2-
4204 Sourced" to send eight events.
Disable for normal alarm processing and go to Prompt
21: "Primary City ID".
This address must be programmed if using the Multi-
Mode feature. The device address must be unique from the normal LRR Device Address (Prompt 28), and the
Keypad Address used for Remote Access or Direct Wire downloading. The address used must also be enabled as a 4204 relay module in Vista and First Alert control panels. See Important Information above.
12
13
14
15
16
Important Information Regarding Private LAN mode (7847i-E only).
1. Prompts 13-20 apply only if Private LAN was selected in Prompt 12.
2.
Prompts 16-18 apply only if Prompt 15: Alarm Delivery is set to “Fail to CS IP2".
En.Priv.LAN: Y/N
(N)
CS IP:
255.255.255.255
CS Port:
(80)
Alarm Delivery:
Only One CS IP_
[Y], [N]
12 digit: xxx.xxx.xxx.xxx
[80]
[Only One CS
IP]
[Fail to CS IP2]
Applies only to 7847i-E. Press [Y] to enable alarm delivery via a Private LAN to a 7810iR-ent receiver.
Press [N] to enable alarm delivery over the internet or if you have a 7847i, and go to Prompt 21: Primary City ID.
Enter the four part primary CS IP address of the
7810iR-ent receiver at the reporting center to which this device will report. The four parts of the address must be separated by spaces.
NOTE: This entry CANNOT be left as 255.255.255.255”.
It MUST be programmed with a valid IP address.
Enter the Central Station Port Number.
NOTE: The CS Port number must match the "Listening
Port" question of the 7810iR-ent.
Select the "Only One CS IP" option, if only one Central
Station IP address is desired and go to Prompt 18:
Verify Inst. Key.
Secondary CS IP:
255.255.255.255
12 digit: xxx.xxx.xxx.xxx
Select the "Fail to CS IP2" option, if a secondary
Central Station IP address is desired.
Enter the four part secondary CS IP address of the
7810iR-ent receiver at the reporting center to which this device will report. The four parts of the address must be separated by spaces.
NOTE: This entry CANNOT be left as “255.255.255.255” if using the Secondary CS IP. It MUST be programmed with a valid IP address.
3-4
Section 3: Programming the 7847i/7847i-E
17
Second CS Port:
(80)
18
IP2 Supervision
30 Day_
[80]
• 30 Day
• Daily
• Full Rate
• None
DESCRIPTION
Enter the Central Station Port Number.
NOTE: The CS Port number must match the "Listening
Port" question of the 7810iR-ent.
Sets the supervision timing for the secondary internet receiver to send a test alarm if set to Daily or 30 Day, or to send a status message to the 7810iR-ent if the interval is set to Full Rate. Selecting Full Rate means secondary supervision will be the same as primary.
NOTE: The second 7810iR-ent must be programmed to supervise subscribers in order to generate a communication failure.
Press the [space] key to scroll through the choices.
19
20
Installation Key:
**********_
Verify Inst. Key:
**********_
[0-9]
[0-9]
Enter the 10-digit Installation Key necessary for communication with 7810iR-ent. If the key entry is invalid, the prompt is repeated. See the Installation
Key paragraph in Section 1 for more information.
Re-enter the 10-digit Installation Key to verify key.
If verification fails, “Verify NOT OK” will be displayed for one second and the display will return to the entry of the installation key.
21
Important Information Regarding Primary and Secondary Accounts (Questions 21-27)
Account information is provided by the central station administrator. If the control supports secondary account reporting, you will need secondary account information, unless using a Private LAN (7847i-E). The
City ID, CS ID or Subscriber ID of the secondary account must differ from that of the primary account. If
Private LAN (7847i-E) is enabled, Prompts 24-27 will not be displayed.
Primary City ID
(??)_
Enter the 2-digit primary city ID, 01-99 (decimal). [01-99]
22
Primary CS ID
(??)
[01-FE] Enter the 2-digit primary central station ID number,
01-FE (HEX).
23
Primary Sub ID
(????)
[0001-9999]
Enter the 4-digit subscriber account number for the primary central station, 0001-9999 (decimal).
24
En. 2 nd
CS Y/N
(N)_
[Y], [N]
25 [01-99]
Applicable only if control supports Central Station #1 and #2 Category Enable reporting for the LRR device
(e.g., VISTA-128BP, FA1660C, etc.).
Used if reporting to a second central station is desired.
Press [N], go to Prompt 28: "Device Address."
Enter the 2-digit secondary city ID, 01-99 (decimal).
26
2 nd
City ID
(??)_
2 nd
CS ID
(??)_
[01-FE]
Enter the 2-digit second central station's ID number,
01-FE (HEX).
27
28
2 nd
Sub ID
(????)_
Device Address
(03)_
[0001-9999]
[01-30]
Enter the 4-digit subscriber account number for the second central station, 0001-9999.
In ECP mode, the 7847i/
7847i-E
communicates with the panel as a Long Range Radio (LRR) device. Enter the appropriate ECP device address. For VISTA-10 and
VISTA-20 series control panels, use address 03. For other controls, see the control panel’s Installation and
Setup Guide.
NOTES:
1. When programming the control, enable the LRR output.
2. The device address must be unique from the "Keypad
Address" entered in Prompt 31, and the Multi-Mode
Address entered in Prompt 11.
3-5
7847i/7847i-E Installation and Setup Guide
NOTE: The Remote Access option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
29
30
Direct Wire Y/N
(N)_
31
32
33
Remote Access Y/N
(N)_
Keypad Address
(28)_
Supervision
(24 Hours)_
Old Alarm Time
10 Minutes_
[Y], [N]
[Y], [N]
[01-30]
• 24 Hours
• 1 Hour
• US UL Line
(6 Min)
• CN UL Line
Lvl 3 (3 Min)
• US UL Line
(90 Sec)
• CN UL Line
Lvl 4 (90 Sec)
• CN UL Line
Lvl 5 (75 Sec)
• None
• 30 Day
•10 Minutes
• 15 Minutes
• 30 Minutes
• 1 Hour
• 2 Hours
• 4 Hours
• 8 Hours
• 12 Hours
• 24 Hours
DESCRIPTION
Press [Y] to allow the end user to access their system via a website. Availability of this service is controlled by the dealer via the web-based programming tool on the AlarmNet Direct website.
Applies only to VISTA-128BP/250BP and FBP Series controls, and FA1600C and FA1700C Series controls.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 29: Remote Access is disabled, skip to Prompt 32: "Supervision."
Must be programmed if using either the Remote Access feature or Direct Wire downloading. Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an alpha keypad in the control panel or an AUI (Advanced
User Interface) type device, if a full enhanced graphic interface to the system is desired and the control panel supports it. DO NOT connect an actual keypad (or any other device) assigned to this address.
2. If using a compatible LynxR-I series control (when available), this address must be set to “1.”
3. This address must be unique from the "Device
Address" entered in Prompt 28.
The AlarmNet network must hear at least one supervisory message from the module during this supervision period; otherwise, AlarmNet notifies the central station that a communication failure has occurred. (If the supervision period is changed after registration, you must re-register the module.)
Press the [space] key to scroll through choices.
Sets how long an undeliverable alarm is retried for delivery to the central station. If the message is not validated, it is retried until the old alarm time is reached or the message is validated.
Press the [space] key to scroll through choices.
UL NOTE: Must be 10 minutes.
3-6
Section 3: Programming the 7847i/7847i-E
34
IP Flt Time
(60 mins)_
[00-99]
DESCRIPTION
Enter the time delay (01-99) in minutes before the
7847i/7847i-E notifies the control panel that there is loss of contact with the network, or enter 00 if you do not want the unit to alert the control panel of loss of contact with the network. The 7847i/7847i-E will alert the control panel of the loss of contact via a dedicated status message.
NOTE: Cannot be less than two (02) minutes if Private
LAN is enabled on the 7847i-E and the Supervision interval is greater than 90 seconds.
UL NOTE: Must be one (01) minute.
35
Flt Rel ON Y/N
(N)_
[Y], [N]
If enabled, the fault open collector output is normally energized to ground, and de-energizes (open circuit) in the event of a module fault.
Set to [Y] if fail-safe mode is desired.
NOTE: If used, the fault relay will trip when the following conditions occur: tamper*, loss of network connectivity*, message communication failure, the device is not registered and the device is remotely disabled by AlarmNet.
* Alarm reporting for the noted condition must be enabled for it to trigger the fault relay.
36
Tamper Rpt Y/N
(Y)_
[Y], [N]
UL NOTE: Must be set to "Y."
Sends a tamper report on zone 6 when the module detects a tamper condition. A tamper restore is automatically sent when the tamper condition clears.
Important Information Regarding Zone Input Options
ECP mode supports two optional hardwire zone input triggers by making connections to the module’s zone 6 and/or zone 7 terminals and programming the appropriate zone trigger options below.
Each zone input can be programmed to cause an alarm under one of the following conditions:
• (V+), where a positive voltage causes an alarm for normally low connections (voltage trigger, NO, NC)
• (V–), where a ground trigger causes an alarm for normally high connections (open collector, NO, NC)
• (EOLR) End of Line Resistor, where the input is supervised by a 2K EOL resistor. The zone can be triggered by open collector, voltage trigger, NO, NC.
In addition to the above, zones can be programmed for an Inverted Trigger, where the alarm and normal states of the zones are inverted; this can serve a fail-safe supervisory purpose for certain installations.
These zone inputs can also be programmed for restore reporting, and for delayed reporting, which allows time for the user to abort false alarms.
NOTE: Optional hardwire zones report in ADEMCO High-Speed format.
37
38
39
40
41
Enable Zn6 Y/N
(N)_
Zn6 Trigger Type
(V+)_
Invert Zn6 Y/N
(N)_
Restore Zn6 Y/N
(Y)_
Delay Zn6 (secs)
(00)_
[Y], [N]
• (V+)
• (V–)
• (EOLR)
[Y], [N]
[Y], [N]
[01-15]
[00] = no delay
Enables alarm reporting for zone 6.
If [N], skip to Prompt 42: "Enable Zn7."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 6 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 6.
Defines the reporting delay in seconds for zone 6.
3-7
7847i/7847i-E Installation and Setup Guide
42
43
44
Enable Zn7 Y/N
(N)_
Zn7 Trigger Type
(V)_
[Y], [N]
• (V+)
• (V–)
• (EOLR)
[Y], [N]
45
46
47
48
Invert Zn7 Y/N
(N)_
Restore Zn7 Y/N
(Y)_
Delay Zn7 (secs)
(00)_
Use DHCP Y/N
(Y)_
NIC IP Address:
255.255.255.255_
[Y], [N]
49
50
51
Subnet Mask:
255.255.255.255_
Gateway IP Addr:
255.255.255.255_
DNS Serv IP Addr:
255.255.255.255_
DESCRIPTION
Enables alarm reporting for zone 7.
If [N], skip to Prompt 47: "Use DHCP."
Selects the triggering method for this zone input.
Press the [space] key to scroll choices.
Inverts the alarm and normal states of the zone 7 trigger; otherwise, uses normal input signal.
Enables restore reporting for zone 7.
[01-15]
[00] = no delay
[Y], [N]
12 digit: xxx.xxx.xxx.xxx
12 digit: xxx.xxx.xxx.xxx
12 digit: xxx.xxx.xxx.xxx
[0.0.0.0.] = not used
12 digit: xxx.xxx.xxx.xxx
[0.0.0.0.] = not used
Defines the reporting delay in seconds for zone 7.
Dynamically allocates the IP addresses (recommended); then skip to Prompt 53: "Review?"
If [N], uses fixed IP addresses.
Enter the 4-part address for this device. The four parts of the address must be separated by spaces (displayed as periods in Review mode).
Enter the 32-bit address mask used to indicate the portion (bits) of the IP address that is being used for the subnet address. The four parts of the address must be separated by spaces (displayed as periods in Review mode).
Enter the 4-part address assigned to the Gateway. The four parts of the address must be separated by spaces
(displayed as periods in Review mode).
Enter the 4-part IP address assigned to the DNS
(Domain Name System) server. The four parts of the address must be separated by spaces (displayed as periods in Review mode).
NOTE: The "Enable Pwr Save" option is not available, and is not displayed, if Private LAN is enabled on the 7847i-E.
52
Enable Pwr Save
(Y)_
53
Review? Y/N
[Y], [N]
[Y] = review
[N] = exit
For 24 hour UL Battery Backup requirement, this feature must be enabled, or the unit must be powered by an appropriate UL listed UPS. If connectivity problems occur with certain routers or switches disable this option.
This option is forced to [N] when Private LAN is enabled.
Reviewing Programming Mode Entries
To review the programming options (to ensure that the correct entries have been made), press [Y]. The programming prompts are displayed again. Use the up/down arrow keys to scroll through the program fields without changing any of the values. If a value requires change, simply type in the correct value. When the last field is displayed, the “REVIEW?” prompt again appears.
To exit the programming mode, press [N] in response to the "REVIEW?" prompt, and refer to
Exiting Programming Mode at the end of this section.
3-8