SECTION 5: Programmer Keyboard Commands. Honeywell AlarmNet 7847i-E, AlarmNet 7847i
تبلیغات
تبلیغات
Section 3: Programming the 7847i/7847i-E
4
5
PROMPTS
Create Password?
Y/N_
Change Password?
Y/N_
ZONE
TRIG.
✔
✔
4204/
2-4204
✔
✔
ENTRY OPTIONS
[Y], [N]
[Y], [N]
DESCRIPTION
Passwords can be used to protect account and programming information.
If no password has been assigned, this prompt appears after pressing [N] at the "Program
Device?" prompt.
If a password is desired, press [Y] and go to
Prompt 6: "Enter Password."
If a password has already been assigned, this prompt appears after pressing [N] at the
"Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key when prompted for the new password and its confirmation.
6
7
Enter Password
Verify Password
✔
✔
✔
✔
[0-9, A-F, N,
S, T, X, Y]
[0-9, A-F, N,
S, T, X, Y]
This prompt is displayed if [Y] was pressed in
Prompt 4 or 5.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
Re-enter the password as confirmation.
If the password doesn't match the first entry, the following is displayed followed by the "Exit Prog.
Mode?" prompt:
8
Exit Prog. Mode?
Y/N_
✔ ✔
[Y], [N]
[ESC]
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is displayed directly.
Exits program mode.
Press [N] to go back to Prompt 3.
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode paragraph in this section.
9
Device Mode
(ECP)_
✔ ✔
• ECP
• Zone Trig.
• 4204 Emu
• Two 4204s
Press the [space] key to scroll through the modes of operation.
Press [ENTER] to select mode.
See Table 3 for ECP mode programming.
Important Information Regarding Multi-Mode
In Zone Trigger mode, the options for Multi-Mode are "Enabled" or "Disabled." If enabled, whenever a zone on the communication device is triggered, a corresponding email message is sent INSTEAD of normal central station reports.
Cover tamper will send email event 8. All communication device system events (such as power loss, etc.) are still sent to AlarmNet.
Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to events triggering the hardwired zones.
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central Station reporting of critical events (alarms, troubles, etc.).
NOTE: The Multi-Mode option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
10
Multi Mode
(Disabled)_
✔
• Enabled
• Disabled
Enable if you want system events sent by email to the user.
Disable for normal alarm processing and go to
Prompt 20: "Primary City ID".
3-11