SECTION 6: Network Diagnostics. Honeywell AlarmNet 7847i-E, AlarmNet 7847i
विज्ञापन
विज्ञापन
7847i/7847i-E Installation and Setup Guide
Important Information Regarding Private LAN mode (7847i-E only).
1. Prompts 12-18 apply only if Private LAN was selected in Prompt 11.
2. Prompts 14-16 apply only if Prompt 14: Alarm Delivery is set to “Fail to CS IP2".
11
12
13
14
15
16
17
18
PROMPTS
En.Priv.LAN: Y/N
(N)
CS IP:
255.255.255.255
CS Port:
(80)
Alarm Delivery:
Only One CS IP_
Secondary CS IP:
255.255.255.255
Second CS Port:
(80)
IP2 Supervision
30 Day_
Installation Key:
**********_
ZONE
TRIG.
✔
✔
✔
✔
✔
✔
✔
✔
4204/
2-4204
✔
✔
✔
✔
✔
✔
✔
✔
ENTRY OPTIONS DESCRIPTION
[Y], [N]
Applies only to 7847i-E. Press [Y] to enable alarm delivery via a Private LAN to a 7810iR-ent receiver.
Press [N] to enable alarm delivery through
AlarmNet and go to Prompt 20: Primary City ID. digit: Enter the 4-part primary CS IP address of the xxx.xxx.xxx.xxx
7810iR-ent receiver at the reporting center to which this device will report. The four parts of the address must be separated by spaces.
NOTE: This entry CANNOT be left as
“255.255.255.255”. It MUST be programmed with a valid IP address.
[80]
[Only One CS
IP]
[Fail to CS
IP2]
Enter the Central Station Port Number.
NOTE: The CS Port number must match the
"Listening Port" question of the 7810iR-ent.
Select the "Only One CS IP" option, if only one
Central Station IP address is desired and go to
Prompt 18: "Installation Key".
Select the "Fail to CS IP2" option, if a secondary
Central Station IP address is desired. digit: Enter the 4-part secondary CS IP address of the xxx.xxx.xxx.xxx
7810iR-ent receiver at the reporting center to which this device will report. The 4-parts of the address must be separated by spaces.
NOTE: This entry CANNOT be left as
“255.255.255.255” if using the Secondary CS IP.
It MUST be programmed with a valid IP address.
[80] Enter the Central Station Port Number.
• 30 Day
• Daily
• Full Rate
•
None
[0-9]
NOTE: The CS Port number must match the
"Listening Port" question of the 7810iR-ent.
If 30 Day or Daily is selected, the 7847i-E will send a test alarm to the second CS IP within that interval.
If Full Rate is selected, a status message is sent to the second CS IP at the same rate as the regular Supervision Interval (Prompt 27).
NOTE: The second 7810iR-ent must be programmed to supervise subscribers in order to generate the communication failure.
Press the [space] key to scroll through the choices.
Enter the 10-digit Installation Key necessary for communication with 7810iR-ent. If the key entry is invalid, the prompt is repeated. See the
Installation Key paragraph in Section 1 for more information.
3-12
Section 3: Programming the 7847i/7847i-E
19
PROMPTS
Verify Inst. Key:
**********_
ZONE
TRIG.
✔
4204/
2-4204
✔
ENTRY OPTIONS DESCRIPTION
[0-9]
Re-enter the 10-digit Installation Key to verify key.
If verification fails, “Verify NOT OK” will be displayed for one second and the display will return to the entry of the installation key.
21
22
23
Important Information Regarding Primary (Questions 20-22)
Account information is provided by the central station administrator.
20
Primary City ID
(??)_
Primary CS ID
(??)
Primary Sub ID
(????)
Device Address
(12)_
✔
✔
✔
✔
✔
✔
✔
[01-99]
[01-FE]
[0001-9999]
[01-15]
Enter the 2-digit primary city ID, 01-99 (decimal).
Enter the 2-digit primary central station ID number, 01-FE (HEX).
Enter the 4-digit subscriber account number, 0001-
9999 (decimal).
The 7847i/
7847i-
E communicates with the control panel as a 4204 relay module. Enter the appropriate address. For VISTA-10P, and
FA130CP Series control panels, this must be address 12. For other controls, see the control panel’s Installation and Setup Guide.
NOTES:
1. The 4204 protocol limits address range to 01-15.
If using 2-4204 mode, the 7847i/7847i-E assigns the second 4204 to the next higher device address (e.g., if entering address 12 for the first
4204, then address 13 is automatically assigned to the second 4204 module). Program the control panel accordingly.
2. The device address(es) must be unique from the
"Keypad Address" entered in Prompt 26 and any other address used on the control panel.
NOTE: The Remote Access option is not available, and will not be displayed, when Private LAN is enabled on the 7847i-E.
24
25
Remote Access Y/N
(N)_
Direct Wire Y/N
(N)_
✔
✔
[Y], [N]
[Y], [N]
Press [Y] to allow the end user to access their system via a website. Availability of this service is controlled by the dealer via the web-based programming tool on the AlarmNet Direct website.
Applies only to VISTA-128BP/250BP and FBP
Series controls, and FA1600C and FA1700C series controls.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 24: Remote Access is disabled, skip to Prompt 27: "Supervision."
3-13
7847i/7847i-E Installation and Setup Guide
26
PROMPTS
Keypad Address
(28)_
ZONE
TRIG.
4204/
2-4204
✔
27
28
Supervision
(24 Hours)_
Old Alarm Time
10 Minutes_
✔
✔
✔
✔
ENTRY OPTIONS DESCRIPTION
[01-30]
Must be programmed if using either the Remote
Access feature or Direct Wire downloading.
Enter the appropriate device address.
NOTES:
1. This address must also be programmed as an alpha keypad in the control panel. If a full enhanced graphic interface to the system is desired, the keypad must also be enabled as an
AUI (Advanced User Interface) device. DO NOT connect to an actual keypad (or any other device) assigned to this address.
2. If using a compatible LynxR-I series control
(when available), this address must be set to
“1.”
3. This address must be unique from the "Device
Address" entered in Prompt 23, and cannot equal that device address plus 1 (one) if using
2-4204 mode.
• 24 Hours
• 1 Hour
• US UL Line
6 Min
• CN UL Line
Lvl 3 (3 Min)
• US UL Line
90 Sec
• CN UL Line
Lvl 4 (90 Sec)
• CN UL Line
Lvl 5 (75 Sec)
• None
• 30 Day
•10 Min.
• 15 Min.
• 30 Min.
• 1 Hr
• 2 Hrs
• 4 Hrs
• 8 Hrs
• 12 Hrs
• 24 Hrs
The AlarmNet network or the 7810iR-ent if
Private LAN is enabled on the 7847i-E, must hear at least one supervisory message from the module during this supervision period; otherwise,
AlarmNet or the 7810iR-ent if Private LAN is enabled on the 7847i-E, notifies the central station that a communication failure has occurred. If the supervision period is changed after registration, you must re-register the module.
Press the [space] key to scroll through choices.
Sets how long an undeliverable alarm is retried for delivery to the central station. If the message is not validated, it is retried until the old alarm time is reached or the message is validated.
Press the [space] key to scroll through choices.
UL NOTE: Must be 10 minutes.
3-14
Section 3: Programming the 7847i/7847i-E
29
30
31
32
PROMPTS
IP Flt Time
(60 mins)_
Flt Rel ON Y/N
(N)_
Tamper Rpt Y/N
(Y)_
Lynx Panic Y/N
(N)_
ZONE
TRIG.
✔
4204/
2-4204
✔
✔
✔
✔
✔
✔
ENTRY OPTIONS
[00-99]
[Y], [N]
[Y], [N]
[Y], [N]
DESCRIPTION
Enter the time delay (01-99) in minutes before the
7847i/7847i-E notifies the control panel that there is loss of contact with the network, or enter 00 if you do not want the unit to alert the control panel of loss of contact with the network. The unit will alert the control panel of the loss of contact via a dedicated status message.
NOTE: Cannot be less than two (02) minutes if
Private LAN is enabled on the 7847i-E and the
Supervision interval is greater than 90 seconds.
UL NOTE: Must be one (01) minute.
If enabled, the fault open collector output is normally energized to ground, and de-energizes
(open circuit) in the event of a module fault.
Set to [Y] if fail-safe mode is desired.
NOTE: If used, the fault relay will trip when the following conditions occur: tamper*, loss of network connectivity*, message communication failure, the device is not registered and the device is remotely disabled by AlarmNet.
* Alarm reporting for the noted condition must be enabled for it to trigger the fault relay.
UL NOTE: Must be set to "Y."
Sends a tamper report on zone 8 when the module detects a tamper condition. A tamper restore is automatically sent when the tamper condition clears.
Applies only if used with a Lynx, LynxR or
LynxR-EN control LRR trigger connected to the module's zone terminal.
Reports a Panic alarm on zone 3 when the module detects a single pulse on zone 1.
No restores are generated for a Panic alarm.
Important Information Regarding Zone Input Options
If desired, 4204 mode supports two optional hardwire zone input triggers by making connections to the module’s zone
6 and/or zone 7 terminals and programming the appropriate zone trigger options below.
NOTE: These triggers are not available when using 2-4204 mode.
Zone Trigger Mode provides six hardwire zone input triggers by making connections to the module’s zone terminals and programming the appropriate zone trigger options below. Zones are numbered 1-7, with zone 2 serving as a reporting zone only (see Bell Output Zone below).
Bell Output Zone 1 (and 2): The zone 1 and 2 terminal can detect both pulsed and steady signals. If connecting the bell output to the 7847i/
7847i-E
zone causes a bell fault on the control panel, enable the "Trip Inputs 1or2" option. The
7847i/7847i-E reports an alarm on zone 1 (fire) when it detects a pulsed signal and an alarm on zone 2 (burglary) when it detects a steady signal.
Telco Zone and Open/Close Zone: Dedicated zones can be assigned as the telco fault zone and/or an open/close
(arm/disarm) reporting zone. When triggered, these zones report a telco line fault or open/close report respectively, in
ADEMCO High-Speed format. Connect the appropriate trigger from the control to the selected zone input for each of these options.
Input Trigger Types: Triggering of each zone input can be programmed to cause an alarm under one of the following conditions:
• (V+), where a positive voltage causes an alarm for normally low connections (voltage trigger, NO, NC)
• (V–), where a ground trigger causes an alarm for normally high connections (open collector, NO, NC)
• (EOLR) End of Line Resistor, where the input is supervised by a 2K EOL resistor. The zone can be triggered by
3-15
7847i/7847i-E Installation and Setup Guide
open collector, voltage trigger, NO, NC.
Inverted Trigger: Zones can be programmed for inverted trigger, where the alarm and normal states of the zones are inverted; this can serve a fail-safe supervisory purpose for certain installations.
Restore and Delayed Reports: Zone inputs can be programmed for restore reporting, and for delayed reporting
(allowing time for the user to abort false alarms).
UL NOTE: Zone restoral must be enabled.
Report Only if Armed option: To help eliminate redundant reports, zone alarms can be restricted to report only if a conditional zone is triggered (armed). If this feature is desired, the conditional zone is automatically used as the
“arming” zone. Connect the appropriate control panel trigger to the conditional (arming) zone. The trigger must be programmed as necessary in the control panel.
The conditional (arming) zone on the module is a different dedicated zone for each programming mode, as follows:
Mode Conditional (Arming) Zone
Zone Trigger 7
4204 4
2-4204 8
IMPORTANT: If any zone (zones 1-6 in zone trigger mode, zones 1-3 in 4204 mode, zones 1-7 in 2-4204 mode) is set for
Report Only if Armed, the conditional (arming) zone becomes unavailable for reporting (as it is reserved for the
“arming” trigger connection).
33
PROMPTS
Trip Inputs 1or2 w/Bell Out (N)_
ZONE
TRIG.
4204/
2-4204
ENTRY OPTIONS
[Y], [N]
DESCRIPTION
34
Telco Zone
(0)_
✔ ✔
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
Use if the zone 1 and 2 connection to the control's bell output causes a bell fault on the control panel.
NOTES:
1. If used, EOLR trigger type is not available for zones 1, 2 and 3.
2. Do not use with Lynx controls.
See Important Information Regarding Zone Input
Options on previous page.
Enter the zone number to be used for telco line fault reports. This zone assignment must be unique from the Open/Close Zone selected in
Prompt 35.
Zone Trigger Mode: If any zone is programmed for "report only if armed," zone 7 cannot be used.
If Lynx Panic is enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for "report only if armed," zone 4 cannot be used.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled, zone 8 cannot be used.
NOTE: Connect the telco line fault output (or relay output programmed for "telco line fault") to the telco zone.
3-16
Section 3: Programming the 7847i/7847i-E
35
PROMPTS
Open/Close Zone
(0)_
ZONE
TRIG.
✔
4204/
2-4204
✔
ENTRY OPTIONS
Zone Trig:
[3-7]
4204: [1-4]
2-4204: [1-8]
[0] = not used
DESCRIPTION
Enter the zone number to be used for open/close
(arm/disarm) reports.
This zone assignment must be unique from the
Telco Zone selected in Prompt 34.
Zone Trigger Mode: If any zone is programmed for "report only if armed," zone 7 cannot be used as an open/close zone. If Lynx Panic is enabled, zone 3 cannot be used.
4204 Mode: If any zone is programmed for "report only if armed," zone 4 cannot be used as an open/close zone.
2-4204 Mode: If any zone is programmed for
"report only if armed," or if tamper is enabled, zone 8 cannot be used as an open/close zone.
NOTE: Connect an open/close (arm/disarm) trigger (or relay output) from the control panel to the open/close zone.
36
Zn1 Trigger Type
(V+)_
✔
• (EOLR)
• (V+)
• (V–)
[Y], [N]
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
37
38
39
40
41
42
Invert Zn1 Y/N
(N)_
Restore Zn1 Y/N
(Y)_
Delay Zn1 (secs)
(00)_
Rpt Zn1 ONLY if
Armed (N)_
Invert Zn2 Y/N
(N)_
Restore Zn2 Y/N
(Y)_
✔
✔
✔
✔
✔
✔
✔
✔
[Y], [N]
[01-15]
[00]=no delay
[Y], [N]
[Y], [N]
[Y], [N]
Inverts the alarm and normal states of the zone 1 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 1.
Defines the reporting delay in seconds for zone 1.
Report alarms on zone 1 ONLY if the conditional zone (zone 7 in zone trigger mode; zone 4 in 4204 mode; or zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 1.
Inverts the alarm and normal states of the zone 2 trigger; otherwise uses normal input signal.
Enables restore reporting for zone 2.
43
Delay Zn2 (secs)
(00)_
✔ ✔ [01-15] Defines the reporting delay in seconds for zone 2.
[00]=no delay
44
Rpt Zn2 ONLY if
Armed (N)_
✔ ✔
[Y], [N] Reports alarms on zone 2 ONLY if the conditional zone (zone 7 in zone trigger mode; zone 4 in 4204 mode; zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 2.
If Lynx Panic is enabled, then skip to Prompt 49: "Rpt Zn3 ONLY if Armed."
45
Zn3 Trigger Type
(V+)_
✔
• (EOLR)
• (V+)
• (V–)
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
46
Invert Zn3 Y/N
(N)_
✔
[Y], [N] Inverts the alarm and normal states of the zone 3 trigger; otherwise uses normal input signal.
3-17
7847i/7847i-E Installation and Setup Guide
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
PROMPTS
Restore Zn3 Y/N
(Y)_
Delay Zn3 (secs)
(00)
Rpt Zn3 ONLY if
Armed (N)_
Zn4 Trigger Type
(V+)_
Invert Zn4 Y/N
(N)_
Restore Zn4 Y/N
(Y)_
Delay Zn4 (secs)
(00)
Rpt Zn4 ONLY if
Armed (N)_
Zn5 Trigger Type
(V+)_
Invert Zn5 Y/N
(N)_
Restore Zn5 Y/N
(Y)_
Delay Zn5 (secs)
(00)_
Rpt Zn5 ONLY if
Armed (N)_
Enable Zn6 Y/N
(N)_
Zn6 Trigger Type
(V+)_
Invert Zn6 Y/N
(N)_
✔
✔
✔
ZONE
TRIG.
✔
✔
4204/
2-4204
✔
✔
ENTRY OPTIONS
[Y], [N]
DESCRIPTION
Enables restore reporting for zone 3.
✔
✔
✔
[01-15] Defines the reporting delay in seconds for zone 3.
[00] = no delay
[Y], [N]
• (EOLR)
• (V+)
• (V–)
[Y], [N]
Reports alarms on zone 3 ONLY if the conditional zone (zone 7 in zone trigger mode; zone 4 in 4204 mode; zone 8 in 2-4204 mode) is triggered
(armed).
If [N], always reports alarms on zone 3.
4204 mode: If any zone is programmed to "Report
Only if Armed," skip to Prompt 60: "Enable Zn6."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 4 trigger; otherwise uses normal input signal.
✔
✔
[Y], [N] Enables restore reporting for zone 4.
✔
✔
✔
✔
2-
4204 only
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 4.
[Y], [N]
• (EOLR)
• (V+)
• (V–)
[Y], [N]
Reports alarms on zone 4 ONLY if the conditional zone (zone 7 in zone trigger mode; zone 8 in 2-
4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 5 trigger; otherwise uses normal input signal.
[Y], [N] Enables restore reporting for zone 5.
✔
✔
✔
✔
2-
4204 only
2-
4204 only
2-
4204 only
4204 only
4204 only
4204 only
[01-15]
[00] = no delay
Defines the reporting delay in seconds for zone 5.
[Y], [N]
[Y], [N]
• (EOLR)
• (V+)
• (V–)
[Y], [N]
Reports alarms on zone 5 ONLY if the conditional zone (zone 7 in zone trigger mode; zone 8 in 2-
4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
Enables alarm reporting for zone 6.
If [N], skip to Prompt 66: "Enable Zn7."
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone 6 trigger; otherwise uses normal input signal.
3-18
Section 3: Programming the 7847i/7847i-E
63
64
65
66
67
68
69
70
71
72
73
74
75
76
PROMPTS
Restore Zn6 Y/N
(Y)_
Delay Zn6 (secs)
(00)_
Rpt Zn6 ONLY if
Armed (N)_
Enable Zn7 Y/N
(N)_
Zn7 Trigger Type
(V+)_
Invert Zn7 Y/N
(N)_
Restore Zn7 Y/N
(Y)_
Delay Zn7 (secs)
(00)_
Rpt Zn7 ONLY if
Armed (N)_
Delay Zn8 (secs)
(00)_
Use DHCP Y/N
(Y)_
NIC IP Address:
255.255.255.255_
Subnet Mask:
255.255.255.255_
Gateway IP Addr:
255.255.255.255_
ZONE
TRIG.
✔
✔
4204/
2-4204
✔
✔
ENTRY OPTIONS
[Y], [N]
DESCRIPTION
Enables restore reporting for zone 6.
✔
✔
✔
✔
✔
✔
✔
✔
✔
✔
4204 only
4204 only
4204 only
✔
✔
✔
2-
4204 only
✔
✔
✔
✔
[01-15]
[00] = no delay
[Y], [N]
[Y], [N]
Defines the reporting delay in seconds for zone 6.
Reports alarms on zone 6 ONLY if the conditional zone (zone 7 in zone trigger mode; zone 4 in 4204 mode; zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 6.
Enables alarm reporting for zone 7.
If [N], skip to Prompt 73: "Use DHCP."
• (EOLR)
• (V+)
• (V–)
[Y], [N]
Selects the triggering method for this zone input.
Press the [space] key to scroll through choices.
Inverts the alarm and normal states of the zone
7 trigger; otherwise uses normal input signal.
[Y], [N]
[01-15]
[00] = no delay
[Y], [N]
[01-15]
[00] = no delay
Enables restore reporting for zone 7.
Zone Trigger mode: This question will only be displayed if zone 7 is not used as the conditional
(arming) trigger zone.
Defines the reporting delay in seconds for zone 7.
Zone Trigger mode: This question will only be displayed if zone 7 is not used as the conditional
(arming) trigger zone.
Reports alarms on zone 7 ONLY if the conditional zone (zone 4 in 4204 mode; zone 8 in
2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 7.
2-4204 mode: If any zone is programmed to
"Report Only if Armed," or if tamper is enabled, skip to Prompt 73: "Use DHCP."
Defines the reporting delay in seconds for zone 8.
[Y], [N]
12 digit: xxx.xxx.xxx.xxx
12 digit: xxx.xxx.xxx.xxx
12 digit: xxx.xxx.xxx.xxx
[0.0.0.0.] = not used
Dynamically allocates the IP addresses
(recommended).
If Private LAN is enabled, skip to Prompt 79:
"Review." Otherwise, skip to Prompt 78: "Enable
Pwr Save."
If [N], uses fixed IP addresses.
Enter the 4-part address for this device. The four parts of the address must be separated by spaces
(displayed as periods in Review mode).
Enter the 32-bit address mask used to indicate the portion (bits) of the IP address that is being used for the subnet address. The four parts of the address must be separated by spaces
(displayed as periods in Review mode).
Enter the 4-part address assigned to the
Gateway. The four parts of the address must be separated by spaces (displayed as periods in
Review mode).
3-19
7847i/7847i-E Installation and Setup Guide
77
PROMPTS
DNS Serv IP Addr:
255.255.255.255_
ZONE
TRIG.
✔
4204/
2-4204
✔
ENTRY OPTIONS
12 digit: xxx.xxx.xxx.xxx
[0.0.0.0.] = not used
DESCRIPTION
Enter the 4-part IP address assigned to the DNS
(Domain Name System) server. The four parts of the address must be separated by spaces
(displayed as periods in Review mode).
NOTE: The "Enable Pwr Save" option is not available, and is not displayed, if Private LAN is enabled on the 7847i-E.
78
Enable Pwr Save
(Y)_
79
Review? Y/N
✔
✔
✔
✔
[Y], [N]
[Y] = review
[N] = exit
For 24 hour UL Battery Backup requirement, this feature must be enabled, or the unit must be powered by an appropriate UL listed UPS. If connectivity problems occur with certain routers or switches disable this option.
This option is forced to [N] when Private LAN is enabled.
Reviewing Programming Mode Entries
To review the programming options (to ensure that the correct entries have been made), press
[Y]. The programming questions are displayed again. Use the up/down arrow keys to scroll through the program fields without changing any of the values. If a value requires change, simply type in the correct value. When the last field is displayed, the “REVIEW?” question again appears.
To exit the programming mode, press [N] in response to the "REVIEW?" question, and refer to Exiting Programming Mode below.
Exiting Programming Mode
To exit the programming mode, press [N] in response to the "REVIEW?" question. Then press [Y] to the "Exit Prog Mode?" question. Upon exiting, the root file is updated to log the changes made. A message is displayed telling the user that this step is being executed.
When complete, the message "DONE" is displayed to indicate the file was successfully uploaded.
If critical configuration changes were made, such as the mode of operation, the 7847i/7847i-E will reset to ensure that the programmed features are enabled.
Setting Factory Defaults
To reset the programming options to factory-default values, press [ESC] at the "Exit Prog
Mode?" prompt.
Set Default?
Y/N_
Press [Y] to reset factory default values.
Press [N] to cancel this function.
If you press [Y], all programmed values are reset to the original factory settings. PLEASE
NOTE THAT THIS WILL ERASE ANY PASSWORD THAT MAY HAVE BEEN ENTERED.
After pressing [Y], the Create Password prompt appears (see Prompt 4).
3-20
S E C T I O N 4
Registration
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
Registering the 7847i/7847i-E
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Registering the 7847i/7847i-E
Once you have initialized and programmed the 7847i/7847i-E, it must be registered to enable the account. An unregistered unit is indicated on the Status Display LEDs as: Status lit,
Message slow blinking, and Fault not lit. The Internet Link may be lit or blinking. Refer to
Appendix A for a detailed discussion of LED operation.
STATUS, GREEN
MESSAGE, YELLOW
FAULT, RED
Figure 9. Unregistered 7847i/7847i-E Status Display In Normal Operation
Throughout this document, the following key is used to describe LED state:
ON OFF FAST BLINK SLOW BLINK
Figure 10. LED Key
To complete the registration process, a 7847i/7847i-E transmits a registration message and receives a registration validation indicating that the account is now enabled.
You can register the 7847i/7847i-E by one of the following methods:
• Through the AlarmNet Direct website
• Through use of the Tamper Switch
• Through use of a 7720P Programming Tool
• By phone.
Registering through AlarmNet Direct Website (does not apply if using Private LAN)
If you have programmed the module through AlarmNet Direct, you must then transfer the data to the module, and register the module.
To do this, please go to: https://services.alarmnet.com/AlarmNetDirect/userlogin.aspx
.
Log in and follow the on-screen prompts.
Please have the following information available when programming the device:
1. Primary City ID (two-digit number)
2. Primary Central Station ID (two-digit hexadecimal number)
3. Primary Subscriber ID (four-digit number)
4. MAC ID and MAC CRC number (located on outside of box and on label inside module)
5. Once module is registered, you may log out of the AlarmNet Direct website.
4-1
7847i/7847i-E Installation and Setup Guide
Using the Tamper Switch
Initiate the registration sequence by clicking the Tamper Switch three times.
You can monitor the registration process by viewing the Status Display. The Message
(yellow) LED and the Status (green) LED will blink slowly in unison while the registration is in progress.
Once the registration has been completed successfully, the 7847i/7847i-E enters normal operating mode; the Status (green) LED goes out and the Message (yellow) LED is lit to indicate that the power-on / reset message is waiting to be sent. This message will appear at the receiving station as “E339 8xx”, where “xx” is the ECP device address.
The description may read “Trouble – Exp. Mod. Reset”. If registration is not validated within 90 seconds, the unit times out, and the (green) LED will be lit (solid).
If repeated registration attempts time out, check your Internet connection and verify that
7847i/7847i-E account information has been entered correctly.
The power-on/reset message will be sent in Ademco High-Speed format if the module is programmed for zone trigger, 4204 or 2x4204 modes.
Using the Programming Tool
The interactive registration feature allows the installer to register the 7847i/7847i-E through a series of keyboard commands on the 7720P Programming Tool. This method of registration lets the installer monitor the registration process.
Registering …
Once the installation is complete, press the [
↑] key on the 7720P. The registration message is sent and the unit waits for the acknowledgment.
Registration
SUCCESS
If this is a new installation and the city, central station, and customer numbers have been correctly entered, the
7847i/7847i-E is registered and this message is displayed. The unit is now in full service and available for alarm reporting to the central station.
Possible Errors When Configured for Private LAN
Function
Unavailable
The Installation Key MUST be programmed in order to initiate the Registration process.
No Registration
Account Disabled
This message will be displayed if the key is invalid.
Account was disabled at the 7810iR-ent prior to the registration attempt or while registration was in progress.
Registration BAD
Timed Out
Registration BAD
Account Exists!
If the Registration Key entered is invalid, this message is displayed.
This prompt is displayed if the account number programmed in the 7847i-E is already being used for a different 7847i-E in the system. If a replacement is desired, enable Substitution Mode in the 7810iR-ent.
Registration BAD
CS Database FULL
Registration BAD
This prompt is displayed if the 7810iR-ent receiver has reached its maximum capacity for accounts. Its database is limited to 300 subscribers.
This prompt is displayed if a general problem occurred when the 7847i-E tried to register with the 7810iR-ent.
4-2
Section 4: Registration
Possible Errors When Configured for AlarmNet-i
Displayed if no response to the registration request is
Registration BAD
Timed Out received.
Registration BAD
Pri Sub ID BAD
Indicates the city, central station, or customer number for the Primary account(s) is not accepted. The ID information was either entered in error, or the central station failed to pre-authorize programmed ID numbers with AlarmNet customer service.
Registration BAD
2nd Sub ID BAD
Indicates the city, central station, or customer number for the Secondary account is not accepted. The ID information was either entered in error, or the central station failed to pre-authorize programmed ID numbers with AlarmNet customer service.
Registration BAD
Pri&Sec
IDs BAD
Displayed when both Primary and Secondary subscriber
IDs are invalid.
Registration BAD
Pri ID – Need PIN
Displayed if this is a repair/replacement, or an error was made in programming the Primary account information of 7847i/7847i-E for an existing account. This prompt appears for 2 seconds. See the Replacing an existing
module section below for further displays.
Registration BAD
2nd ID – Need PIN
Displayed if this is a repair/replacement, or an error was made in programming the Secondary account information of 7847i/7847i-E for an existing account.
This prompt appears for 2 seconds. See the Replacing
an existing module section below for further displays.
Registration BAD
Pri&2nd – Need PIN
Displayed if this is a repair/replacement, or an error was made in programming BOTH the Primary and
Secondary account information of 7847i/7847i-E for an existing account. This prompt appears for 2 seconds.
See the Replacing an existing module section below for further displays.
Replacing an existing module using the programming tool
Enter PIN#
This prompt appears after pressing the down arrow [
↓↓↓↓] on the 7720P.
NOTE: If it is necessary to exit registration mode, press
ESC from the 7720P programming tool.
Registering …
Registration
SUCCESS
Enter a 4-digit alphanumeric PIN number provided by an authorized AlarmNet representative.
Press the [ENTER] key.
The registration message is sent and the unit waits for acknowledgement.
If the PIN is valid, the new 7847i/7847i-E is registered and the old unit unregistered. Additionally, AlarmNet sends a substitution alarm to the central station.
4-3
7847i/7847i-E Installation and Setup Guide
Registration BAD
If you entered an invalid PIN, the appropriate message is displayed depending on which account number is being replaced (see above for exact wording). The registration process is repeated.
NOTE: Each attempt causes a substitution alarm to be
sent to the central station.
Register by Phone
You can register the module by calling the AlarmNet Technical Assistance Center (TAC) at
1-800-222-6525.
You will need the following information:
• MAC number (found on the label).
• Subscriber information (provided by the central station), including a city code, CSID, and a subscriber ID.
• When instructed to do so, triple-click the tamper switch to complete the registration.
4-4
S E C T I O N 5
Programmer Keyboard Commands
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Programmer Keyboard Commands
Programmer keyboard commands can be used to quickly view your Internet connectivity settings and options. Most commands require you to press the [shift] key and then the designated command key. (See the keys designated in red on the 7720P Programming Tool.)
[A]
7847i-e x.x.xx mm/dd/yy
[B]
[C]
[D]
MAC xxxxxxxxxxxx
MAC CRC xxxx
Mon 23 Jul 2007
03:45:23 am
Physical Link:
GOOD
Software Revision
Depending on unit being programmed, either "7847i" or
"7847i-e" will be displayed.
"x.x.xx" indicates the installed software Revision.
Mm/dd/yy indicates month, day and year of the revision.
MAC Address
“xxxxxxxxxxxx” indicates the 7847i/7847i-E's unique identification number.
"xxxx" indicates the MAC CRC number. This number is also found on the label on the module, as well as the label on the box.
Time
Retrieves the current date and time from the AlarmNet network in Greenwich Mean Time (GMT). This display confirms that the module is in sync with network.
Network Diagnostics Display
NIC IP Address: xxx.xxx.xxx.xxx
Subnet Mask: xxx.xxx.xxx.xxx
Gateway IP Address: xxx.xxx.xxx.xxx
DNS Server IP: xxx.xxx.xxx.xxx
Encryption Test:
AES Passed!
Indicates whether device has detected a physical connection to the internet.
Press the [space] key to go to the next field.
IP Information Display
Displays the IP address assigned to this device.
Press the [space] key to go to the next field.
Displays the 32-bit address mask used to indicate the portion (bits) of the IP address that is being used for the subnet address.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Displays the IP address assigned to the Gateway.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Displays the IP address assigned to the DNS (Domain
Name System) server.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Performs a self-test of the chosen encryption algorithm.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
5-1
7847i/7847i-E Installation and Setup Guide
[F]
DHCP
OK/BAD
Testing Gateway
DHCP (Dynamic Host Configuration Protocol) indicates server is performing satisfactorily.
Press the [space] key to go to the Physical Link display.
Run Network Diagnostic Test
Performs a set of network diagnostics that tests the integrity of the links between the unit and the various connection points (Redirs) to AlarmNet. Refer to
Section 6: Network Diagnostics.
System Status Displays
[S]
ECP 67 Tm Flt
xx 5 OK
1234 67 Tm Flt
5555 xx 5 OK
12345678 Tm Flt
5555555x 5 OK
1234567 Tm Flt
5555555 5 OK
[T]
Test Msg Sent
ECP Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
4204 Emulation Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Two-4204 Emulation Mode
Displays the zone and system fault status.
Press the [space] key to go to the next field.
Press the [backspace] key to go to the previous field.
Zone Trigger Mode
The status of the unit can be viewed on the 7720P. The status display includes:
• Zone input status (1234567) - the numbers 1-7 represent the 7 mappings of the zone input, and follow Honeywell's
ADEMCO high-speed format codes:
1 = New Event
5 = Normal
X = Not Enabled
• Tm – Tamper status follows high-speed format codes above.
• Flt – Represents radio faults:
OK = Normal ; No fault
I – No network connectivity over IP and
fault time has expired
i – No network connectivity over IP and
fault time has NOT yet expired.
NOTE: The 7720P will not operate if the power line
voltage is removed.
Test Alarm
Sends a test alarm to AlarmNet only if Private LAN is not enabled; otherwise, it is sent the Primary CS IP and the Secondary if it is enabled.
5-2
Section 5: Programmer Keyboard Commands
[X]
[
↑↑↑↑]
(UP arrow)
[
↓↓↓↓]
(DN arrow)
[0]
[ENTER]
Reset CPU Y/N
Registering …
Enter PIN#
Force Server Update?
Y/N_
Strt Prog Mode?
Y/N_
Reset the 7847i/7847i-E
Pressing [N] returns to diagnostic mode (blank screen = enter next command or escape).
Pressing [Y] resets the module (blank screen = reset complete).
Registration
Registers a programmed 7847i-E with the 7810iR-ent if it is configured to report on the Private LAN. If it is configured to report to AlarmNet, the 7847i/7847i-E will register with AlarmNet. Refer to Section 4:
Registration.
Registration with PIN for Replacement Module
Registers a replacement unit with AlarmNet, once programmed, using the existing PIN #.
If Private LAN is enabled, down arrow is not applicable.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configuration file to the server.
Pressing [N] cancels the operation.
NOTE: If Private LAN is enabled, "Function
Unavailable" is displayed.
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].
5-3
7847i/7847i-E Installation and Setup Guide
5-4
S E C T I O N 6
Network Diagnostics
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
In This Section
♦
Running Network Diagnostics on the
7847i/7847i-E using AlarmNet
♦
Running Network Diagnostics on the 7847i-E using a Private LAN
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Running Network Diagnostics on the 7847i/7847i-E using AlarmNet
The network diagnostic process tests the integrity of the links between the unit and the various connection points of AlarmNet Control that are known as "Redirects" (Redirs or
RDR).
To initiate the network diagnostics, press the [F] key on the 7720P.
NOTE: The test is performed ONLY if a physical link is detected. If no physical link is detected,
the test is aborted and the following is displayed:
No Physical Link
If a physical link is detected, the diagnostics are performed. The following shows the progression of the test:
Testing Redir 1
Testing Redir 1
Reached Redir 1
Reached Redir 1
Testing Service
Redir 1
Service OK
Testing Redir 2
Testing Redir 2
Reached Redir 2
Reached Redir 2
Testing Service
The first step of the test traces the connection to Redir 1 at AlarmNet Control.
A successful trace to Redir 1 is indicated here. See below for possible errors that may occur at this stage of testing.
After a successful trace to Redir 1, a test of the service at
Redir 1 is performed. That is, the first test determines if a message can reach AlarmNet Control; this test determines if the connection point (Redir) at AlarmNet
Control knows what to do with the message once it receives it.
The service at AlarmNet Control on Redir 1 is functioning. See below for possible errors that may occur at this stage of testing.
The first step of the test traces the connection to Redir 2 at AlarmNet Control.
A successful trace to Redir 2 is indicated here. See below for possible errors that may occur at this stage of testing.
After a successful trace to Redir 2, a test of the service at
Redir 2 is performed. That is, the first test determines if a message can reach AlarmNet Control; this test determines if the connection point (Redir) at AlarmNet
Control knows what to do with the message once it receives it.
6-1
7847i/7847i-E Installation and Setup Guide
Redir 2
Service OK
Testing Redir 3
Testing Redir 3
Reached Redir 3
Reached Redir 3
Testing Service
Redir 3
Service OK
RDR1 RDR2 RDR3
OK OK OK
The service at AlarmNet Control on Redir 2 is functioning. See below for possible errors that may occur at this stage of testing.
The first step of the test traces the connection to Redir 3 at AlarmNet Control.
A successful trace to Redir 3 is indicated here. See below for possible errors that may occur at this stage of testing.
After a successful trace to Redir 3, a test of the service at
Redir 1 is performed. That is, the first test determines if a message can reach AlarmNet Control; this test determines if the connection point (Redir) at AlarmNet
Control knows what to do with the message once it receives it.
The service at AlarmNet Control on Redir 3 is functioning. See below for possible errors that may occur at this stage of testing.
A summary of the tests is displayed after Redir 3 is tested. The example shows that the tests of all three connection points, or Redirs, were successful. If an error occurred at any point, the summary will display “FAIL” under the faulty Redir.
Possible Errors Running Network Diagnostics
Errors may occur at either while tracing the connection to a given Redir or while testing the service at a given Redir. The following list highlights the most common errors. Please contact the AlarmNet Technical Assistance Center (TAC) for help regarding any errors NOT listed below:
Possible Errors
Testing Redir x
FAIL before Gtwy
Testing Redir x
FAIL at Gtwy
Testing Redir x
FAIL at Pvt IP
Testing Redir x
FAIL on IP Addr
Redir x
ERR:Proxy 18
While tracing the connection to Redir x, the trace fails before ever reaching the local gateway (router).
While tracing the connection to Redir x, the trace fails after reaching the local gateway (router).
While tracing the connection to Redir x, the trace fails after reaching the private IP.
While tracing the connection to Redir x, the trace fails after reaching the public IP.
After a successful trace to Redir x, the test of the service timed out without a response.
6-2
Section 6: Network Diagnostics
Running Network Diagnostics on the 7847i-E using a Private LAN
The network diagnostic process tests the integrity of the links between the 7847i-E and the
7810iR-ent to which it should report.
To initiate the network diagnostics, press the [F] key on the 7720P.
NOTE: The test is performed ONLY if a physical link is detected. If no physical link is detected,
the test is aborted and the following is displayed:
No Physical Link
If a physical link is detected, the diagnostics are performed. The following shows the progression of the test:
Testing CSIP 1
Testing CSIP 1
Reached CSIP 1
Reached CSIP 1
Testing Service
CSIP 1
Service OK
Testing CSIP 2
Testing CSIP 2
Reached CSIP 2
Reached CSIP 2
Testing Service
CSIP 2
Service OK
Testing CSIP 3
Testing CSIP 3
Reached CSIP 3
The first step of the test traces the connection to CS IP
1.
A successful trace to CS IP 1 is indicated here. See below for possible errors that may occur at this stage of testing.
After a successful trace to CS IP 1, a test of the service
at CS IP 1 is performed. That is, the first test determines if a message can reach 7810iR-ent; this test determines if the connection point (CSIP) at the 7810iRent knows what to do with the message once it receives it.
The service at the 7810iR-ent on CS IP 1 is functioning.
See below for possible errors that may occur at this stage of testing.
The first step of the test traces the connection to CS IP 2 at the 7810iR-ent.
A successful trace to CS IP 2 is indicated here. See below for possible errors that may occur at this stage of testing.
After a successful trace to CS IP 2, a test of the service
at CS IP 2 is performed. That is, the first test determines if a message can reach the 7810iR-ent; this test determines if the connection point (CSIP) at the
7810iR-ent knows what to do with the message once it receives it.
The service at the 7810iR-ent on CS IP 2 is functioning.
See below for possible errors that may occur at this stage of testing.
The first step of the test traces the connection to CS IP 3 at the 7810iR-ent.
A successful trace to CS IP 3 is indicated here. See below for possible errors that may occur at this stage of testing.
6-3
7847i/7847i-E Installation and Setup Guide
Reached CSIP 3
Testing Service
After a successful trace to CS IP 3, a test of the service
at CS IP 1 is performed. That is, the first test determines if a message can reach the 7810iR-ent; this test determines if the connection point (CSIP) at the
7810iR-ent knows what to do with the message once it receives it.
CSIP 3
Service OK
The service at the 7810iR-ent on CS IP 3 is functioning.
See below for possible errors that may occur at this stage of testing.
Testing CSIP 2
If CS IP 2 and/or CS IP 3 are not programmed, display will read.
Does Not Exist
CIP1 CIP2 CIP3
OK/Fail N/A N/A
A summary of the tests is displayed after CS IP 3 is tested. The example shows that CS IP 2 and/or CS IP 3 are not programmed.
Possible Errors Running Network Diagnostics using a Private LAN
Errors may occur at either while tracing the connection to a given 7810iR-ent or while testing the service at a given 7810iR-ent. The following list highlights the most common errors. Please contact the AlarmNet Technical Assistance Center (TAC) for help regarding any errors NOT listed below:
Possible Errors
Testing CSIP x
FAIL before Gtwy
Testing CSIP x
FAIL at Gtwy
Testing CSIP x
FAIL on IP Addr
While tracing the connection to CS IP x, the trace fails before ever reaching the local gateway (router).
While tracing the connection to CS IP x, the trace fails after reaching the local gateway (router).
While tracing the connection to CS IP x, the trace fails after reaching the CS IP.
6-4
Appendices
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
Appendix A: Summary of LED Operation
Status Display Operation
The 7847i/7847i-E Status Display has three LEDs used to indicate message and device status: red
GREEN
(STATUS)
YELLOW
(MESSAGE)
RED
(FAULT)
7847i-E-025-V0
Figure 11. 7847i/7847i-E Status Display LEDs with Front Cover Installed
Each LED can have four different states - ON, OFF, FAST BLINK and SLOW BLINK.
Throughout this document, the following key is used to describe LED state:
ON OFF FAST BLINK
Figure 12. LED Key
SLOW BLINK
7847i-E-033-V0
A-1
7847i/7847i-E Installation and Setup Guide
LED COLOR
YELLOW
RED
Table 6. Status Display Operation
LED LABEL
MESSAGE
FAULT
DESCRIPTION
7847i-E
is NOT registered with AlarmNet or
7810iR-ent if Private LAN is enabled.
OFF – 7847i/
7847i-E
is registered with AlarmNet or 7810iR-ent if
Private LAN is enabled.
FAST BLINK – Download session with Compass in progress.
SLOW BLINK – In unison with yellow LED – registration in progress.
ON – Message transmission pending.
QUICK PERIODIC BLINK – Normal.
FAST BLINK – Message waiting for network ACK.
SLOW BLINK – Idle, power abnormal.
– In unison with green LED – registration in progress.
ON – No contact with the network.
OFF– Normal.
SLOW BLINK – Loss of communication with the panel (ECP fault).
FAST BLINK – No network contact AND loss of communication with the panel.
A B
STATUS, GREEN STATUS, GREEN
MESSAGE, YELLOW MESSAGE, YELLOW
FAULT, RED FAULT, RED
Figure 13. A Registered 7847i/7847i-E Status Display (A) and an Unregistered 7847i/7847i-E Status Display in Normal Operating State(B)
The sequence below illustrates LED operation when 7847i/7847i-E transmits a message.
1 2 3 4
STATUS, GREEN
MESSAGE, YELLOW
FAULT, RED
Figure 14. LED Sequence for a Registered 7847i/7847i-E Message Transmission
A-2
Appendices
Network Connectivity Display
The Network Connectivity display can only be viewed with the cover removed. It is used as a visual indication of 7847i/7847i-E network activity.
NETWORK COLLISION (YEL)
LINK SPEED (GRN)
ETHERNET LINK/ACTIVITY (GRN)
NETWORK CONNECTIVITY
LED DISPLAY
7847i-E-032-V0
Figure 15. 7847i/7847i-E Network Connectivity Display
The Network Connectivity Display consists of three LEDs. They function as follows:
LED COLOR LED LABEL
DESCRIPTION
1
ST
GREEN
2
ND
GREEN
COLLISION
LINK SPEED ON – 100 MB/S link to Internet.
OFF – 10 MB/S link to Internet.
ETHERNET
LINK /
ACTIVITY
OFF – Normal.
ON – Ethernet link detected.
OFF – No Ethernet link detected.
FAST BLINK – Transmitting/Receiving data.
NOTE: When "Enable Pwr Save" is enabled, LED status is displayed once every 15 seconds.
A-3
7847i/7847i-E Installation and Setup Guide
Mode and Status LED Display
The Mode and Status LED Display consists of 4 LEDs. LED 1 (red LED on the left) will be off, LED 2 and 3 (yellow LEDs) indicate operation mode. LED 4 (1 st
green LED) displays Web connection status; LEDs 5 and 6 are not used.
Mode and Status Indicator Switch
Press and hold the Mode and Status Indicator Switch to change the LED functions in order to view the mode of operation and network carrier status. When the switch is held down,
LED 1 (red LED on the left) will be off, and the LEDs from left to right have the following meanings:
Table 7. LED Functions with Mode and Status Indicator Switch Depressed
LED 1
(red)
LED 2
(1
st
yellow)
with LED 3
LED 3
(2
nd
yellow)
with LED 2
(1
LED 4
st
green)
Web
Connection
Table 7a. Operation Modes
OPERATION
MODE
ECP
Zone
4204
2 – 4204
LED 2
(1
st
yellow)
LED 3
(2
nd
yellow)
OFF OFF
ON OFF
OFF ON
ON ON
Table 7b. Status Indications
STATUS
LED 4
(1
st
green)
SLOW BLINK
NORMAL BLINK
FAST BLINK
Trying to connect
–
Web communication
A-4
Appendix B: Central Station Messages
The following messages are sent by the 7847i/7847i-E module for the conditions listed below.
Table 8. Central Station Messages
Alarm Condition
ECP Mode
Alarm Code
ECP Mode
Restore Code
Zone and 4204
Modes
Alarm Code
Zone and 4204
Modes
Restore Code
Power On Reset
Tamper
E339 C08xx* 5551 5555 6
E341 C08xx* R341C 08xx* 5555 5551 7 5555 5553 7
ECP Supervision
E355 C0000
Primary CS IP Supervision
(7847i-E, Private LAN ONLY) E954 C0951
Secondary CS IP
Supervision
(7847i-E, Private LAN ONLY) E954 C0952
Swinger Suppression
Telco
Open/Close
Test
* xx = 7847i/7847i-E Device Address
5555 5555 9
R355 C0000
R954 C0951
R954 C0952
5555 5515 5
5555 5551 5
5555 5551 1
0D00 0005 0
5555 5155 6
2 sent in selected zone
5555 5555 9
The control panel sends its own general code (E353) for a trouble condition.
5555 5535 5
5555 5553 5
5555 5553 1
5555 5355 6
4 sent in selected zone
B-1
7847i/7847i-E Installation and Setup Guide
B-2
Appendix C: IP Downloading
General Information
The 7847i/7847i-E can be used to provide high-speed up/downloading to Honeywell VISTA and LynxR-I control panels. This allows site maintenance independent of central station monitoring, and modification to sites through an Intranet or globally via the Internet.
Residential panels that support IP downloading (e.g., Vista-20P and LynxR-I) are connected to the unit through the ECP bus. Currently, commercial controls such as VISTA-128BP and
FBP support IP downloading through use of a Direct Wire connection (using the trigger cable).
UL
Downloading may only be performed if a technician is at the site.
Direct Wire Setup
To perform IP up/downloading using Direct Wire, the unit requires that Direct Wire downloading over IP programming is enabled (Direct Wire Y/N), and that the ECP Device
Address on which the unit communicates with the control panel as a keypad is entered
(Keypad Address). Additionally, the 7847i/7847i-E must be connected by cable as shown below to the panels listed.
NOTES:
1. For Direct Wire IP downloading on Commercial Fire panels (e.g. VISTA-128FBP,
FA1700C), Program Field 3*19 Enable J2 Header Printer Port must be set to "1".
2. This feature is not available if device is set for zone trigger mode.
VISTA-128BP/250BP
FA1660C
J8 CONNECTOR
7847i / 7847i-E
PROGRAMMER
PORT
1 2 3 4 5 6 7 8 9
WHITE
NU
BLUE
K4668WH
RJ 11 CABLE
IN 2
PRINTER DTR
IN 3
GR
OUND
OUT 5 OUT 6
GR
OUND
GR
OUND
4142 TR CABLE
TB 1
1
2
3
8
9
10
11
4
5
6
7
1
PARTS SUPPLIED WITH DOWNLOADER KIT P/N VBPCOMKIT
VISTA-128FBP/250FBP
FA1670C /FA1700C
J2 CONNECTOR
2 3 4 5 6 7 8 9
TO
AUX PWR 1
OUTPUT
OUT 4 OUT 7 OUT 3 OUT 6 OUT 2 OUT 5 OUT 1
GR
OUND
INPUT 1
4142 TR CABLE
+ (TO TERM 11)
- (TO TERM 12)
4100SM
3
2
1
8
7
6
5
4
+ PWR
- (GND)
RXD not used not used
TXD not used not used
RED BLUE WHITE
PROGRAMMER
PORT
TB 1
1
2
3
4
10
11
7
8
9
5
6
7847i-E-026-V0
7847i / 7847i-E
PARTS SUPPLIED WITH DOWNLOADER KIT P/N VFBPCOMKIT
K14394LF 25-PIN TO RJ11 CABLE
7847i-E-027-V0
Figure 16. Cable Connections for IP Downloading
C-1
7847i/7847i-E Installation and Setup Guide
Prior to IP up/downloading over an Intranet (Private LAN), setup of the Honeywell Compass
Connect Server and Honeywell Compass downloader is required. Refer to the Compass
Connect Server Installation and Setup Guide (K10178V1) and the Compass IP Downloading
Supplement (K10441V1) for setup instructions.
The figures below show data flow depending on whether the system is set up for use with the
Internet or Intranet.
VISTA PANEL COMPASS
INTERNET
7847i / 7847i-E
VISTA
PANELS
ALARMNET
ROUTING CENTER
Figure 17. Internet Flow Diagram
7810iR-ent
COMPASS
7847i-E
CONTROL
SERVER
DATA
SERVER
Figure 18. Private LAN (Intranet) Flow Diagram
C-2
Appendix D: Glossary
AES – Advanced Encryption Standard
DHCP – Dynamic Host Configuration Protocol. Provides a mechanism for allocating IP addresses dynamically so that addresses can be reused when hosts no longer need them.
DNS – Domain Name System. A distributed hierarchical naming system used to resolve domain names (e.g., www.yahoo.com) into numerical IP addresses (e.g., 204.17.25.1.).
DSL – Digital Subscriber Line
Gateway IP Address – A gateway (sometimes called a router) is a computer and/or software used to connect two or more networks (including incompatible networks) and translates information from one network to the other. The Gateway IP address is the IP address for the gateway.
IP – Internet Protocol
IP Address – A unique number consisting of four parts separated by periods, sometimes called a "dotted quad.," for example: 204.17.29.11, assigned to every computer/workstation connected to the Internet. IP numbers can be "static" (assigned and unchanging) or
"dynamic," assigned via DHCP at each and every startup.
ISP – Internet Service Provider
LAN – Local Area Network
MAC Address – The hardware address of a device connected to a network.
NAT – Network Address Translation
PPP – Point-to-Point Protocol
PPPoE – Point-to-Point Protocol over Ethernet
Subnet Mask – A Subnet is a portion of a network that shares a network address with other portions of the network, and is distinguished by a subnet number. The Subnet Mask is a 32bit address mask used in IP to indicate the bits of an IP address that are being used for the subnet address.
TCP/IP – Transmission Control Protocol / Internet protocol
D-1
7847i/7847i-E Installation and Setup Guide
D-2
NOTES:
7847i/7847i-E Installation and Setup Guide
NOTES:
NOTES:
7847i/7847i-E Installation and Setup Guide
NOTES:
NOTES:
7847i/7847i-E Installation and Setup Guide
NOTES:
7847i/ 7847i-E
Summary of Connections
STATUS LED
MESSAGE LED
FAULT LED
7720P PROGRAMMER PORT/
PANEL DOWNLOAD PORT
NOT USED
NOT USED
12V DC IN
GND
ZONE INPUT Z1/Z2 or ECP INPUT
ZONE INPUT Z3 or ECP OUTPUT
ZONE INPUT Z4 or NOT USED
ZONE INPUT Z5 or NOT USED
ZONE INPUT Z6 or NOT USED
ZONE INPUT Z7 or NOT USED
OPEN COLLECTOR FAULT OUTPUT
MOUNTING HOLE
CONNECTOR FOR USE
WITH DCID ONLY
TB 1
1
2
3
4
5
9
10
11
6
7
8
1
TAMPER
SWITCH
RJ45
ETHERNET
PORT
NETWORK
CONNECTIVITY
LED DISPLAY
MODE AND
STATUS
LED DISPLAY
MODE AND
STATUS
INDICATOR
SWITCH
7847i-E-015-V0
TB1 Wiring for 7847i/7847i-E Internet/Intranet Communication Module
TB1
5
6
7
1
2
3
4
8
9
10
11
2 x 4204
Mode
4204
Mode
Zone
Mode
ECP
Mode
WIRE
COLOR
--- --- --- ---
--- --- --- ---
ECP IN
ECP OUT
NOT USED
NOT USED
FLT OUT
ECP IN
ECP OUT
NOT USED
NOT USED
FLT OUT
Z1/Z2
Z3
Z4
Z5
FLT OUT
ECP IN YEL
ECP OUT
NOT USED
GRN
NOT USED
FLT OUT
LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 2 Corporate Center Drive, Melville, NY,
11747, warrants its product(s) to be in conformance with its own plans and specifications and to be free from defects in materials and workmanship under normal use and service for 24 months from the date stamp control on the product(s) or, for product(s) not having a manufacturer’s date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply. Seller's obligation shall be limited to repairing or replacing, at its option, free of charge for materials or labor, any product(s) which is proved not in compliance with Seller's specifications or proves defective in materials or workmanship under normal use and service. Seller shall have no obligation under this Limited Warranty or otherwise if the product(s) is altered or improperly repaired or serviced by anyone other than Honeywell factory service. Connection of any device(s) to a communicating bus of a Honeywell security system (e.g., keypad bus, polling loop) other than those manufactured or approved by Honeywell shall void this warranty. For warranty service, return product(s) transportation prepaid, to your local authorized Honeywell representative.
THERE ARE NO WARRANTIES, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO CASE SHALL SELLER BE LIABLE TO
ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS
OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE
SELLER'S OWN NEGLIGENCE OR FAULT.
Seller does not represent that the product(s) it sells may not be compromised or circumvented; that the product(s) will prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product(s) will in all cases provide adequate warning or protection.
Customer understands that a properly installed and maintained alarm system may only reduce the risk of a burglary, robbery, fire, or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY
DAMAGE OR OTHER LOSS BASED ON A CLAIM THAT THE PRODUCT(S) FAILED TO GIVE WARNING. HOWEVER, IF SELLER IS HELD
LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR
OTHERWISE, REGARDLESS OF CAUSE OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE
PURCHASE PRICE OF THE PRODUCT(S), WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER.
This warranty replaces any previous warranties and is the only warranty made by Seller on this product(s). No increase or alteration, written or verbal, of the obligations of this Limited Warranty is authorized.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright
2007 Honeywell International Inc. www.honeywell.com/security.com
ÊK14175CŠ
K14175 11/07
डाउनलोड
विज्ञापन