Step 1 Your system must be in the Disarmed state to change user codes.

Step 2 Press [

U]-[5].

Step 3 Enter a “Master Arm/Disarm Code”.

NOTE: For partitioned systems, someone changing the code of another person must have access to all or more partitions than the user being changed.

Step 4 The ready light will flash.

Step 5 Enter the 2-digit “user number”. You must always enter 2 digits, such as [0] - [3] for user 3, or [1] - [2] for user 12.

Step 6 Enter the new four (4) or six (6) digit “user code”.

NOTE: To delete a user code, enter [ or [

U]-[U]-[U]-[U] for a 4-digit code,

U]-[U]-[U]-[U]-[U]-[U] for a 6-digit code.

[*]-[*]-[*]-[*]

Step 7 The ready light will flash indicating you are back at Step 4 above. If the code is rejected, the sounder will beep 3 times.

Step 8 If another “user code” needs to be programmed, return to Step 5.

Step 9 Press the [#] key while the ready light is flashing to exit the User

Code Programming Mode.

ASSIGNING USER CODE AUTHORITY LEVELS

Assign authority levels to users by following the steps below. Assign user codes before assigning authority levels.

Step 1 Press [

U]-[6].

Step 2 Enter a “Master Arm/Disarm Code”.

NOTE: Someone changing the authority of another person can only add or remove partition authorization for partitions to which they have access.

Step 3 The ready light will flash.

Step 4 Enter the 2-digit “user number” to be assigned authority (The ready

light is constant and the instant light will flash).

Step 5 Lights illuminated indicate the authority levels assigned to this code. An explanation of the lights is listed below. You may toggle

(turn on/off) the authority level by pressing the number for that authority level.

10

LIGHT

1

2

3

4

5

6

7

8

AUTHORITY LEVELS IF LIGHT 8 IS OFF

Reserved (Note: Do not change if on.)

Arm Only

Arm Only After Clos ing Time

Master Arm/Disarm (can program other codes)

Arm/Disarm

Bypass Zones

Open / Close Reporting

If this light is on, this code is programmed as a function code. Do not change! Press [#] - [#] to exit.

Step 6 Press the [

UU] key. The ready light will flash. This moves you to the partition enable. (The user has access in partitions that are illuminated.)

Step 7 The illuminated numbers indicate each partition where the user has access. To change any of the partitions where the user has access, press numbers corresponding to areas where you want to give the user access or deny access. (Example: If zone light #2 is lit, then the user is assigned access to partition #2. By pressing the

[2] key, the light will go off, denying access to partition #2. Refer to chart shown below.

LIGHT

1

2

PARTITIONS ASSIGNED

Partition 1

Partition 2

Step 8 When the partitions are assigned, press the [

U] key. This returns you to Step 3 previously mentioned. At this point you may enter another user number to assign authority level. Repeat Steps 4 - 8 until you have assigned authority levels to all user numbers.

Step 9 Press the [#] key to exit the Assigning Authority Level Program.