Hardware Component Overview. Juniper JCS 1200
Publicitate
Publicitate
Chapter 2
Hardware Component Overview
This chapter describes the hot-swappable components for the JCS 1200 platform in the following topics:
■
■
■
■
■
■
■
■
■
■
Major Components of the JCS 1200 Platform on page 9
JCS 1200 Alarm Panel Module Overview on page 12
JCS 1200 Fan Module Overview on page 14
JCS 1200 Management Module Overview on page 15
JCS 1200 Media Tray Overview on page 18
JCS 1200 MUX Card Overview on page 20
JCS 1200 Power Module Overview on page 22
JCS 1200 Routing Engine Overview on page 24
JCS 1200 Switch Module Overview on page 27
JCS 1200 Power Connectors on page 30
Major Components of the JCS 1200 Platform
Figure 3 on page 10 and Figure 4 on page 11 show the locations of the major
components in the JCS 1200 platform. These modules supply common functions to the Routing Engines that are installed in the bays in the front of the JCS 1200 platform.
Major Components of the JCS 1200 Platform
■ 9
Juniper Control System (JCS) 1200 Platform Hardware Guide
Figure 3: Exploded Front View of Components in the JCS 1200 Platform
10 ■
Major Components of the JCS 1200 Platform
Chapter 2: Hardware Component Overview
Figure 4: Exploded Rear View of Components in the JCS 1200 Platform
NOTE: The JCS 1200 platform comes with two DC power boxes or two AC power boxes. The power boxes cannot be changed from the type that is already installed.
Related Topics
■
■
■
■
■
■
■
■
■
■
JCS 1200 Hardware Overview on page 4
JCS 1200 Alarm Panel Module Description on page 12
JCS 1200 Fan Module Description on page 14
JCS 1200 Management Module Description on page 15
JCS 1200 Media Tray Description on page 18
JCS 1200 MUX Card Description on page 21
JCS 1200 Power Module Description on page 22
JCS 1200 Routing Engine Description on page 24
JCS 1200 Switch Module Description on page 27
JCS 1200 Power Connectors on page 30
Major Components of the JCS 1200 Platform
■ 11
Juniper Control System (JCS) 1200 Platform Hardware Guide
JCS 1200 Alarm Panel Module Overview
Topics include:
■
■
JCS 1200 Alarm Panel Module Description on page 12
JCS 1200 Alarm Panel Module Connectors and LEDs on page 12
JCS 1200 Alarm Panel Module Description
The JCS 1200 platform comes with an alarm panel module that provides telecom relays and LED alarm status. You can also connect each Routing Engine to a console by connecting an external breakout cable to the serial port on the alarm panel module.
Related Topics
■
JCS 1200 Alarm Panel Module Connectors and LEDs on page 12
■
JCS 1200 Alarm Panel Module Interface Connector Electrical
■
■
■
■
Pinouts for the JCS 1200 Alarm Panel Interface Connector on page 213
JCS 1200 Alarm Panel Module Interface Connector Electrical
Replacing a JCS 1200 Alarm Panel Module or Module Filler on page 96
Locating the JCS 1200 Alarm Panel Serial Number on page 197
JCS 1200 Alarm Panel Module Connectors and LEDs
Figure 5 on page 12 shows the location of LEDs and connectors on the alarm panel
module.
Figure 5: JCS 1200 Alarm Panel Module LEDs and Connectors
12 ■
JCS 1200 Alarm Panel Module Overview
Chapter 2: Hardware Component Overview
The JCS 1200 alarm panel module consists of the following components:
■
■
Serial connector—This DB-60 connector provides direct access to the serial ports on each of the 12 Routing Engine bays. Use this connector to attach the optional serial port breakout cable and connect up to 12 local consoles.
Telco alarm connector—The alarm panel module provides one DB-15 connector
(male) for critical, major, and minor telco alarms. Each of the alarms has a relay that enables multiple system alarm indicators to be daisy-chained together.
■
LEDs—The alarm panel module contains seven LEDs. Table 8 on page 13
describes the function of each LED.
Table 8: JCS 1200 Alarm Panel Module LEDs
Name
Power-on
Location
Critical system fault
Major system fault
Minor system fault
Color
Green
–
State
On steadily
Off
Description
Power is present in the JCS 1200 platform.
The power subsystem, the power module, or the LED has failed.
CAUTION: If the power-on LED is off, it does not mean that no electrical current is present in the JCS 1200 platform. The LED might be defective. To remove all electrical current from the
JCS 1200 platform, you must disconnect all power cords from the rear power connectors.
Blue
Amber or red
NOTE: The color of this
LED can be set to amber or red through the management module.
On steadily or flashing
Indicates that the LED has been turned on by the system administrator, to aid in visually locating the JCS 1200 platform.
After the JCS 1200 platform has been located, you can have the system administrator turn off the location LED.
On steadily The JCS 1200 platform has a critical system fault. A critical system fault is an error or event that is detected by the system and that has a significant impact to the system. In this case, the system cannot continue to operate or is operating in a nonredundant power or cooling configuration.
Amber or red
NOTE: The color of this
LED can be set to amber or red through the management module.
On steadily
Amber On steadily
The JCS 1200 platform has a major system fault. The system can continue to operate but may lose some functionality and performance.
FRU ready for removal
Alarm panel module fault
Blue
Amber
On steadily
On steadily
The JCS 1200 platform has a minor system fault. The system can continue to operate, usually without noticeable loss of functionality or performance.
It is safe to remove the alarm panel module from the JCS 1200 platform.
Indicates that there is a fault on the alarm panel module. The system can continue to operate, usually without the use of the components on the alarm panel module.
JCS 1200 Alarm Panel Module Connectors and LEDs
■ 13
Juniper Control System (JCS) 1200 Platform Hardware Guide
Related Topics
■
■
■
■
■
■
JCS 1200 Alarm Panel Module Description on page 12
JCS 1200 Alarm Panel Module Connectors and LEDs on page 12
JCS 1200 Alarm Panel Module Interface Connector Electrical
Pinouts for the JCS 1200 Alarm Panel Interface Connector on page 213
Replacing a JCS 1200 Alarm Panel Module or Module Filler on page 96
Locating the JCS 1200 Alarm Panel Serial Number on page 197
JCS 1200 Fan Module Overview
Topics include:
■
■
JCS 1200 Fan Module Description on page 14
JCS 1200 Fan Module LED on page 14
JCS 1200 Fan Module Description
The JCS 1200 platform comes with four hot-swappable fan modules for cooling redundancy. The fan module speeds vary depending on the ambient air temperature within the JCS 1200 platform, which is reported by the media tray. If the ambient temperature is 77° F (25° C) or below, the JCS 1200 platform fan modules run at their minimum rotational speed. If the ambient temperature is above 77° F (25° C), the fan modules run faster, increasing their speed as required to control internal
JCS 1200 platform temperature. Each fan module contains two fans operating as a pair in a series. If one fan fails, the remaining fan runs at full speed and continues to cool the JCS 1200 platform. Replace a failed fan module as soon as possible to restore cooling redundancy.
NOTE: While the JCS 1200 is operating, remove only one fan module at a time.
Removing two fan modules might cause the JCS 1200 platform to overheat. If you remove two fan modules while the JCS 1200 platform is operating, the management module powers off all Routing Engines.
Related Topics
■
■
■
■
JCS 1200 Fan Module LED on page 14
Replacing a JCS 1200 Fan Module on page 116
Troubleshooting JCS 1200 Fan Module Problems on page 86
Locating the JCS 1200 Fan Module Serial Number on page 198
JCS 1200 Fan Module LED
Figure 6 on page 15 shows the location of the LED on the fan module.
14 ■
JCS 1200 Fan Module Overview
Chapter 2: Hardware Component Overview
Figure 6: JCS 1200 Fan Module
Table 9 on page 15 describes the function of the LED.
Table 9: JCS 1200 Fan Module LED
Name
Fan module error
Color
Amber
State
On steadily
Description
An error has been detected in the fan module or power to the fan module is not present. The system-error LEDs on the
JCS 1200 alarm panel are also lit.
Related Topics
■
■
■
■
JCS 1200 Fan Module Description on page 14
Replacing a JCS 1200 Fan Module on page 116
Troubleshooting JCS 1200 Fan Module Problems on page 86
Locating the JCS 1200 Fan Module Serial Number on page 198
JCS 1200 Management Module Overview
Topics include:
■
■
JCS 1200 Management Module Description on page 15
JCS 1200 Management Module Connectors and LEDs on page 16
JCS 1200 Management Module Description
The management module is a hot-swappable module that you use to configure and manage JCS 1200 components. See the JUNOS Protected System Domain Configuration
Guide for information about configuring the management module.
You can order the JCS 1200 platform with one or two hot-swappable management modules. Install the management modules in management module bay 1 and management module bay 2 to provide redundancy.
JCS 1200 Management Module Overview
■ 15
Juniper Control System (JCS) 1200 Platform Hardware Guide
NOTE: When you install a management module into the JCS 1200 platform, a management module interposer must be installed into the bay before installing the management module.
Related Topics
■
■
■
■
■
■
JCS 1200 Management Module Connectors and LEDs on page 16
Replacing a JCS 1200 Management Module Filler Tray on page 127
Replacing a JCS 1200 Management Module Interposer on page 128
Replacing a JCS 1200 Management Module or Module Filler on page 124
Troubleshooting JCS 1200 Management Module Problems on page 87
Locating the JCS 1200 Management Module Serial Number on page 199
JCS 1200 Management Module Connectors and LEDs
Figure 7 on page 16 shows the input and output connectors on the management
module.
Figure 7: JCS 1200 Management Module Input and Output Connectors
Figure 8 on page 17 shows the location of LEDs and controls on the management
module.
16 ■
JCS 1200 Management Module Connectors and LEDs
Chapter 2: Hardware Component Overview
Figure 8: JCS 1200 Management Module LEDs and Controls
The management module consists of the following components:
■
Serial connector—Use this connection to configure and manage the JCS 1200 components over a serial line through the management module CLI. This connector provides local access to the CLI and any Routing Engine. For example, you can connect a notebook computer to the serial connector and a terminal emulator program to configure the IP addresses, user accounts, and other management settings through the CLI user interface. See the JUNOS Protected
System Domain Configuration Guide for more information.
■
■
■
■
Video connector—The video connector is not supported.
Console (Ethernet) connector—Use this connector for a remote Ethernet connection to a network management station on the network.
Two USB ports for mouse and keyboard—The USB ports are not supported.
Reset button—When you press this button, the blowers operate at full speed while the management module is initializing.
■
The reset button provides the following functions:
■
Press and release the reset button to restart the management module.
■
Press and hold the reset button for 8 seconds to restore the management module to factory default settings.
LEDs—There are five LEDs on the management module that provide status information about the management module and remote management connection.
Table 10 on page 18 describes the functions of these LEDs (see
JCS 1200 Management Module Connectors and LEDs
■ 17
Juniper Control System (JCS) 1200 Platform Hardware Guide
Table 10: JCS 1200 Management Module LEDs
Name Color State Description
Power-on
Active
Management module error
Ethernet Link (LINK)
Green
Green
Amber
Green
On steadily
On steadily
On steadily
On steadily
The management module has power.
The management module is actively controlling the JCS 1200 platform. Only one management module actively controls the
JCS 1200 platform. If two management modules are installed in the JCS 1200 platform, this LED is lit on only one module.
An error has been detected in the management module. When this LED is lit, the JCS 1200 system error LED is also lit on the alarm panel.
There is an active connection through the Ethernet port to the network.
There is activity through the port over the network link.
Ethernet activity
(TX/RX)
Green Flashing
Related Topics
■
■
■
■
■
■
JCS 1200 Management Module Description on page 15
Replacing a JCS 1200 Management Module Filler Tray on page 127
Replacing a JCS 1200 Management Module Interposer on page 128
Replacing a JCS 1200 Management Module or Module Filler on page 124
Troubleshooting JCS 1200 Management Module Problems on page 87
Locating the JCS 1200 Management Module Serial Number on page 199
JCS 1200 Media Tray Overview
Topics include:
■
■
JCS 1200 Media Tray Description on page 18
JCS 1200 Media Tray Connectors and LEDs on page 19
JCS 1200 Media Tray Description
Figure 9 on page 19 shows the JCS 1200 media tray.
18 ■
JCS 1200 Media Tray Overview
Chapter 2: Hardware Component Overview
Figure 9: JCS 1200 Media Tray
The media tray is a hot-swappable module that provides two USB connectors for use by the Routing Engines, error LEDs, an ambient air temperature sensor and a pressure sensor for use by the management module, and two compact flash bays.
You can order the JCS 1200 platform with one or two hot-swappable media trays.
The media trays can be installed in media tray bay 1 and media tray bay 2 to provide redundancy.
Related Topics
■
JCS 1200 Media Tray Connectors and LEDs on page 19
■
Replacing a JCS 1200 Media Tray on page 128
■
■
Troubleshooting JCS 1200 Media Tray Problems on page 88
Locating the JCS 1200 Media Tray Serial Number on page 200
JCS 1200 Media Tray Connectors and LEDs
Figure 10 on page 19 shows the location of LEDs and connectors on the media tray.
Figure 10: JCS 1200 Media Tray Components
Each media tray consists of the following components:
■
■
USB connectors—Use these connectors to upgrade software on the Routing
Engines. The attached USB device must be compatible with USB v2.0, or earlier.
LED panel—The LEDs on the media tray provide status information for your
JCS 1200 platform. Table 11 on page 20 describes the functions of these LEDs.
JCS 1200 Media Tray Connectors and LEDs
■ 19
Juniper Control System (JCS) 1200 Platform Hardware Guide
Table 11: JCS 1200 Media Tray LEDs
Name
Power-on
Color
Green
–
Location Blue
State
On steadily
Off
Description
Power is present in the JCS 1200 platform.
The power subsystem, the power module, or the LED has failed.
CAUTION: If the power-on LED is off, it does not mean that electrical current is not present in the JCS 1200 platform. The
LED might be defective. To remove all electrical current from the JCS 1200 platform, you must disconnect all power cords from all power input connectors.
Flashing or on steadily
Indicates that this LED has been turned on by the system administrator to aid in visually locating the JCS 1200 platform.
NOTE: You can turn off the location LED through the management module.
Critical system fault (CRT)
Amber or red
NOTE: The color of this
LED can be set to amber or red through the management module.
On steadily
Major system fault (MJR)
Amber or red
NOTE: The color of this
LED can be set to amber or red through the management module.
On steadily
The JCS 1200 platform has a critical system fault. A critical system fault is an error or event that is detected by the system and that has a significant impact to the system. In this case, the system cannot continue to operate or is operating in a nonredundant power or cooling configuration.
The JCS 1200 platform has a major system fault. The system can continue to operate but might lose some function and performance.
Minor system fault (MNR)
Amber
Media tray fault Amber
On steadily
On steadily
The JCS 1200 platform has a minor system fault. The system can continue to operate, usually without noticeable loss of functionality or performance.
There is a fault on the media tray. The system can continue to operate, usually without the use of the components on the media tray.
Related Topics
■
■
■
■
JCS 1200 Media Tray Description on page 18
Replacing a JCS 1200 Media Tray on page 128
Troubleshooting JCS 1200 Media Tray Problems on page 88
Locating the JCS 1200 Media Tray Serial Number on page 200
JCS 1200 MUX Card Overview
Topics include:
■
■
JCS 1200 MUX Card Description on page 21
JCS 1200 MUX Card LEDs on page 21
20 ■
JCS 1200 MUX Card Overview
Chapter 2: Hardware Component Overview
JCS 1200 MUX Card Description
Related Topics
The JCS 1200 platform comes with two hot-swappable multiplexer (MUX) cards for redundancy. The MUX card controls the USB connectors, console redirection, and status LEDs on the JCS 1200 platform. Replace a MUX card as soon as possible, to restore redundancy.
■
JCS 1200 MUX Card LEDs on page 21
■
Replacing a JCS 1200 MUX Card on page 131
■
Locating the JCS 1200 MUX Card Serial Number on page 201
JCS 1200 MUX Card LEDs
Figure 11 on page 21 shows the location of the LEDs on the JCS 1200 MUX card.
Figure 11: JCS 1200 MUX Card LEDs
MUX card fault
The functions of the MUX card LEDs are described in Table 12 on page 21.
Table 12: JCS 1200 MUX Card LEDs
Name
FRU ready for removal
Color
Blue
State
On steadily
Amber On steadily
Description
Indicates that it is safe to remove the device from the
JCS 1200 platform.
There is a fault on the MUX card. The system can continue to operate, usually without the use of the components on the MUX card.
NOTE: When removing the MUX card, you must install another MUX card in its place to maintain proper cooling in the JCS 1200 platform.
Related Topics
■
■
JCS 1200 MUX Card Description on page 21
Replacing a JCS 1200 MUX Card on page 131
JCS 1200 MUX Card Description
■ 21
Juniper Control System (JCS) 1200 Platform Hardware Guide
■
Locating the JCS 1200 MUX Card Serial Number on page 201
JCS 1200 Power Module Overview
Topics include:
■
■
JCS 1200 Power Module Description on page 22
JCS 1200 Power Module LEDs on page 23
JCS 1200 Power Module Description
Figure 12 on page 22 shows the AC and DC power modules.
Figure 12: Top: AC Power Modules; Bottom: DC Power Modules
The JCS 1200 platform is configured with four hot-swappable power modules.
Power modules are required in bays 1 and 2. They supply power to Routing Engine bays 1 through 6, media trays 1 and 2, management module bays 1 and 2, and switch module bays 1 through 4.
Power modules are required in power module bays 3 and 4 if you install Routing
Engines in Routing Engine bays 7 through 12 or if you install switch modules in any of switch module bays 7 through 10.
22 ■
JCS 1200 Power Module Overview
Chapter 2: Hardware Component Overview
Each pair of power modules operates as a redundant pair. If either power module fails, the remaining power module continues to supply power, but there is no redundancy; the failed power module must be replaced as soon as possible.
Related Topics
■
JCS 1200 Power Module LEDs on page 23
■
■
■
■
Replacing a JCS 1200 Power Module on page 138
Replacing a JCS 1200 Power Box on page 134
Troubleshooting JCS 1200 Power Problems on page 89
Locating the JCS 1200 Power Module Serial Number on page 202
JCS 1200 Power Module LEDs
Figure 13 on page 23 shows the LEDs on each power module.
Figure 13: JCS 1200 Power Module LEDs
The LEDs on each power module indicate the condition of the power module and fan pack.
NOTE: The orientation of the power module that is shown in Figure 13 on page 23
is for one of the top power modules. Modules in the bottom power module bays are rotated 180°.
Power module error Amber
Fan error
Table 13 on page 23 describes the functions of the LEDs on the power modules.
Table 13: JCS 1200 Power Module LEDs
Name
Input power
Color
Green
State
On steadily
Amber
On steadily
On steadily
Description
The input from the external power source connected to the power module is present and within specifications. During typical operation, both the input power and output power LEDs are lit.
A power module failure has occurred, and the power module is not operating within specifications.
A fan pack has failed and is not operating within specifications.
JCS 1200 Power Module LEDs
■ 23
Juniper Control System (JCS) 1200 Platform Hardware Guide
Table 13: JCS 1200 Power Module LEDs (continued)
Name
Output power
Color
Green
State
On steadily
Description
The output from the power module to the other components and
Routing Engines is present and within specifications. During typical operation, both the input power and output power LEDs are lit.
Related Topics
■
■
■
■
■
JCS 1200 Power Module Description on page 22
Replacing a JCS 1200 Power Module on page 138
Replacing a JCS 1200 Power Box on page 134
Troubleshooting JCS 1200 Power Problems on page 89
Locating the JCS 1200 Power Module Serial Number on page 202
JCS 1200 Routing Engine Overview
Topics include:
■
■
JCS 1200 Routing Engine Description on page 24
JCS 1200 Routing Engine Control Panel Buttons and LEDs on page 25
JCS 1200 Routing Engine Description
Figure 14 on page 24 shows a JCS 1200 Routing Engine.
Figure 14: JCS 1200 Routing Engine
24 ■
JCS 1200 Routing Engine Overview
Chapter 2: Hardware Component Overview
The JCS 1200 platform provides 12 bays for Routing Engines. A Routing Engine is a hot-swappable independent server with its own processors, memory, storage, network controllers, operating system, and applications. The Routing Engine is installed in a bay in the JCS 1200 platform and shares power, fans, switches, and ports with other
Routing Engines.
NOTE: JCS 1200 Routing Engines can be used only on the JCS 1200 platform.
The Ethernet controllers on the Routing Engine communicate with the network through the Ethernet-compatible switch modules on the JCS 1200 platform. Network signals to and from the Routing Engine are automatically routed to a same-network-interface switch module through circuitry in the JCS 1200 platform.
Related Topics
■
JCS 1200 Routing Engine Control Panel Buttons and LEDs on page 25
■
Powering On a JCS 1200 Routing Engine on page 73
■
■
■
Powering Off a JCS 1200 Routing Engine on page 74
Replacing a JCS 1200 Routing Engine on page 140
Locating the JCS 1200 Routing Engine Serial Number on page 203
JCS 1200 Routing Engine Control Panel Buttons and LEDs
NOTE: The control panel door is shown in the closed position in Figure 15 on page 25.
To access the power control button, you must open the control panel door.
Figure 15: JCS 1200 Routing Engine Control Panel
KVM select button
Activity LED
Mastership LED
Information LED
Blade-error LED
Media-tray select button
Power-control button
Power-on LED
JCS 1200 Routing Engine Control Panel Buttons and LEDs
■ 25
Juniper Control System (JCS) 1200 Platform Hardware Guide
Each Routing Engine consists of the following components:
■
Keyboard/video/mouse (KVM) select button—This button is not supported.
■
Media tray select button—Press this button to associate the shared media tray
(removable media drives and front panel USB ports) with the Routing Engine.
The LED on the button flashes while the request is being processed and then is lit when ownership of the media tray has been transferred to the Routing Engine.
It can take approximately 20 seconds for the operating system in the Routing
Engine to recognize the media tray.
■
■
If there is no response when you press the media tray select button, you can use the management module to determine whether local control has been enabled on the Routing Engine.
Power-control button—Press this button to power on or power off the Routing
Engine.
LEDs—There are five LEDs that indicate the status of the Routing Engine.
Table 14 on page 26 describes the functions of these LEDs.
Table 14: JCS 1200 Routing Engine LEDs
Name
Activity
Mastership
Information
Blade-error
Power-on
Color
Green
Blue
Amber
Amber
Green
Green
Green
State
On steadily
On steadily
On steadily
On steadily
Flashing rapidly
Flashing slowly
On steadily
Description
There is activity on the hard disk drive or network.
Indicates mastership in a redundant Routing Engine pair.
A system error in the Routing Engine has been placed in the management module event log. The information LED can be turned off through the management module
A system error has occurred in the Routing Engine (blade). The blade-error LED turns off only after the error is corrected.
The service processor (BMC) on the Routing Engine is communicating with the management module.
The Routing Engine has power but is not turned on.
The Routing Engine has power and is turned on.
Related Topics
■
■
■
■
■
JCS 1200 Routing Engine Description on page 24
Powering On a JCS 1200 Routing Engine on page 73
Powering Off a JCS 1200 Routing Engine on page 74
Replacing a JCS 1200 Routing Engine on page 140
Locating the JCS 1200 Routing Engine Serial Number on page 203
26 ■
JCS 1200 Routing Engine Control Panel Buttons and LEDs
Chapter 2: Hardware Component Overview
JCS 1200 Switch Module Overview
Topics include:
■
■
JCS 1200 Switch Module Description on page 27
JCS 1200 Switch Module Components and LEDs on page 27
JCS 1200 Switch Module Description
Figure 16 on page 27 shows the JCS 1200 switch module.
Figure 16: JCS 1200 Switch Module
The JCS 1200 platform supports two hot-swappable switch module bays (see “JCS 1200
Hardware Overview” on page 4 for the location of the switch module bays). You
must install a switch module interposer into the bay before you install a switch module into the JCS 1200 platform.
NOTE: High-speed switch modules are not supported.
Related Topics
■
■
■
■
■
JCS 1200 Switch Module Components and LEDs on page 27
Replacing a JCS 1200 Switch Module Filler Tray on page 145
Replacing a JCS 1200 Switch Module Interposer on page 146
Replacing a JCS 1200 Switch Module or Module Filler on page 143
Locating the JCS 1200 Switch Module Serial Number on page 205
JCS 1200 Switch Module Components and LEDs
Figure 17 on page 28 shows the components on the switch module.
JCS 1200 Switch Module Overview
■ 27
Juniper Control System (JCS) 1200 Platform Hardware Guide
Figure 17: JCS 1200 Switch Module Components
The switch module consists of the following components:
■
■
■
One RS-232 console port that provides an additional means to install software and configure the switch module. This USB-style connector enables connection of a special serial cable to the switch module.
Six external copper 1000Base-T Ethernet ports for 10/100/1000 Mbps connections to the T-series routing platform. These ports are identified as EXT1, EXT2, EXT3,
EXT4, EXT5, and EXT6 in the switch configuration menus and are labeled
1 through
6
(from top to bottom) on the switch module. You can use RJ-45 ports labeled 1 through 3 to connect up to three T-series routing platforms running
JUNOS Release 9.2 to the JCS 1200 platform. The RJ-45 ports labeled 4 and 5 on the switch module are reserved for future use. You can use the RJ-45 port labeled
6 to manage the switch module.
Eight LEDs that indicate the status of the switch module and the network (see
28 ■
JCS 1200 Switch Module Components and LEDs
Figure 18: JCS 1200 Switch Module LEDs
Chapter 2: Hardware Component Overview
The functions of the switch module LEDs are described in Table 15 on page 29.
Table 15: JCS 1200 Switch Module LEDs
Name
OK
Gigabit Ethernet switch module error (fault) (!)
Amber
Ethernet link (LINK)
Ethernet activity
(Tx/Rx)
Color
Green
Green
Green
State
On steadily
On steadily
Description
The switch module has passed the power-on self-test
(POST) with no critical faults and is operational.
The switch module has failed the POST or detected an operational fault.
NOTE: When the Gigabit Ethernet switch module error
LED is lit, the system-error LED on the alarm panel is also lit
On steadily There is a connection (or link) to a device using that connector.
Flashing
NOTE: The flash frequency is proportional to the amount of traffic on the network link.
Data is being transmitted or received (that is, activity is occurring) between that port and another device on the network link.
Related Topics
■
■
■
■
■
JCS 1200 Switch Module Description on page 27
Replacing a JCS 1200 Switch Module Filler Tray on page 145
Replacing a JCS 1200 Switch Module Interposer on page 146
Replacing a JCS 1200 Switch Module or Module Filler on page 143
Locating the JCS 1200 Switch Module Serial Number on page 205
JCS 1200 Switch Module Components and LEDs
■ 29
Juniper Control System (JCS) 1200 Platform Hardware Guide
JCS 1200 Power Connectors
Connect a power cord from each power connector to an appropriate power source.
Related Topics
■
JCS 1200 AC Power Electrical Safety Guidelines and Warnings on page 174
■
■
■
Connecting the JCS 1200 AC Platform to AC Power on page 62
JCS 1200 DC Power Electrical Safety Guidelines on page 175
Connecting the JCS 1200 DC Platform to DC Power on page 63
30 ■
JCS 1200 Power Connectors
Part 2
Initial Installation
■
■
■
■
■
■
Preparing the Site for JCS 1200 Platform Installation on page 33
Unpacking the JCS 1200 Platform on page 39
Installing the JCS 1200 Mounting Hardware on page 43
Installing the JCS 1200 Platform on page 49
Connecting the JCS 1200 Platform on page 59
Configuration Guidelines on page 81
Initial Installation
■ 31
Juniper Control System (JCS) 1200 Platform Hardware Guide
32 ■
Initial Installation
Descarcă