Prochem CHPH 10075260 Operating instructions

Add to My manuals
56 Pages

advertisement

Prochem CHPH 10075260 Operating instructions | Manualzz

Operating Instructions (ENG)

MODELS: C2

10075170

10075210

C2H

10075190

10075220 10075260

Read instructions before operating the machine.

T

86038850 07/17/09

PRV NO. 98925

MACHINE DATA LOG/OVERVIEW

MODEL _______________________________________

DATE OF PURCHASE __________________________

SERIAL NUMBER ______________________________

SALES REPRESENTATIVE # _____________________

DEALER NAME ________________________________

OPERATIONS GUIDE NUMBER ___________________

PUBLISHED __________________________________________

YOUR DEALER

Name: __________________________________________________________________________________________________

Address: _______________________________________________________________________________________________

For the name and address of your dealer contact: Windsor Industries

Phone Number: _________________________________________________________________________________________

2 CHEYENNE 86038850 03/08/07

Machine Data Log/Overview.........................2

Table of Contents..........................................3

HOW TO USE THIS MANUAL

How to use this Manual.................................1-1

SAFETY

Important Safety Instructions ........................2-1

Hazard Intensity Level. .................................2-2

Grounding Instructions..................................2-3

OPERATIONS

Technical Specifications. ..............................3-1

Controls.........................................................3-2

Machine Operation........................................3-3

Pre-Run Machine Inspection......................3-3

Equipment Set-up ......................................3-3

Cleaning & Emptying Tanks.......................3-3

Shut Down and Storage.............................3-4

MAINTENANCE

Maintenance .................................................4-1

Daily Maintenance. ....................................4-1

Periodic Maintenance. ...............................4-1

Monthly Maintenance.................................4-1

Semi-Annually............................................4-1

Lubrication .................................................4-1

Storage. .....................................................4-1

Solution Pump Replacement. .......................4-2

Vacuum Motor Replacement ........................4-2

Vacuum Carbon Brush Replacement. ..........4-2

Pump Replacement Parts. ............................4-3

Pressure Regulator. ......................................4-4

Machine Troubleshooting..............................4-5

CHEYENNE 86038850 03/08/07

TABLE OF CONTENTS

GROUP PARTS LIST

Base Group................................................... 5-1

Solution Tank Group................................... .5-3

Pump Group 100 PSI

No Heat 2 St Vac ...................................... 5-5

Pump Group 100 PSI

No Heat 3 St Vac ....................................... 5-7

Pump Group 100 PSI

With Heat 2 St Vac .................................... 5-9

Pump Group 200 PSI

No Heat 3 St Vac. .................................... 5-11

Pump Group 200 PSI

With Heat 7.2 3 St Vac. ........................... 5-13

Recovery Tank Group-2 St. ........................ 5-15

Recovery Tank Group-3 St. ........................ 5-17

Recovery Tank Group- 2 St With Heat ....... 5-19

Recovery Tank Group-3 St With Heat ........ 5-21

Vacuum Group-2 St .................................... 5-23

Vacuum Group-3 St .................................... 5-25

Vacuum Group-7.2-3 St.............................. 5-27

Heater Group…………………………………5-29

Tank & Lid Group........................................ 5-31

Label and Strap Group ............................... 5-33

Wiring Group 100-PSI 2 St Vac .................. 5-35

Wiring Group 100-PSI 3 St Vac .................. 5-36

Wiring Group 200 PSI 3 St Vac .................. 5-37

Wiring Group 200 PSI-7.2-3 St Vac............ 5-38

Wiring Group Heater................................... 5-39

Notes .......................................................... 5-40

Warranty ........................................... ……...5-41

3

This manual contains the following sections:

- HOW TO USE THIS MANUAL

- SAFETY

- OPERATIONS

- MAINTENANCE

- PARTS LIST

The HOW TO USE THIS MANUAL section will tell you how to find important information for ordering correct repair parts.

Parts may be ordered from authorized dealers.

When placing an order for parts, the machine model and machine serial number are important. Refer to the MACHINE DATA box which is filled out during the installation of your machine. The MACHINE

DATA box is located on the inside of the front cover of this manual.

MODEL _____________________________________

DATE OF PURCHASE ________________________

SERIAL NUMBER ____________________________

SALES REPRESENTATIVE # ___________________

DEALER NAME ______________________________

OPERATIONS GUIDE NUMBER __________________

PUBLISHED ________________________________

The model and serial number of your machine is located on the inner wall of solution tank, above the pump.

1-1 CHEYENNE 86038850 03/08/07

HOW TO USE THIS MANUAL

The SAFETY section contains important information regarding hazard or unsafe practices of the machine. Levels of hazards is identified that could result in product or personal injury, or severe injury resulting in death.

The OPERATIONS section is to familiarize the operator with the operation and function of the machine.

The MAINTENANCE section contains preventive maintenance to keep the machine and its components in good working condition.

The PARTS LIST section contains assembled parts illustrations and corresponding parts list. The parts lists include a number of columns of information:

- REF – column refers to the reference number on the parts illustration.

- PART NO. – column lists the part number for the part.

- PRV NO. – reference number.

- QTY – column lists the quantity of the part used in that area of the machine.

- DESCRIPTION – column is a brief description of the part.

- SERIAL NO. FROM – column indicates the first machine the part number is applicable to. When the machine design has changed, this column will indicate serial number of applicable machine.

The main illustration shows the most current design of the machine. The boxed illustrations show older designs. If column has an asterisk (*), call manufacturer for serial number.

- NOTES – column for information not noted by the other columns.

NOTE: If a service or option kit is installed on your machine, be sure to keep the KIT INSTRUCTIONS which came with the kit. It contains replacement

parts numbers needed for ordering future parts.

IMPORTANT SAFETY INSTRUCTIONS

When using an electrical appliance, basic precaution must always be followed, including the following:

READ ALL INSTRUCTIONS BEFORE USING THIS MACHINE.

!

WARNING:

To reduce the risk of fire, electric shock, or injury:

Use only indoors. Do not use outdoors or expose to rain.

Use only as described in this manual. Use only manufacturer’s recommended components and attachments.

If the machine is not working properly, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center.

Do not operate the machine with any openings blocked. Keep openings free of debris that may reduce airflow.

This machine is not suitable for picking up hazardous dust.

Machine can cause a fire when operating near flammable vapors or materials. Do not operate this machine near flammable fluids, dust or vapors.

This machine is suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices for more than normal housekeeping purposes.

Maintenance and repairs must be done by qualified personnel.

During operation, attention shall be paid to other persons, especially children.

When leaving unattended, secure against unintentional movement.

The machine shall only be operated by instructed and authorized persons.

When leaving unattended, switch off or lock the main power switch to prevent unauthorized use.

Do not handle the plug or machine with wet hands.

Do not unplug machine by pulling on cord. To unplug, grasp the plug, not the cord.

Do not use with damaged cord or plug. Follow all instructions in this manual concerning grounding the machine.

Do not pull or carry by cord, use cord as a handle, close a door on cord, or pull cord around sharp edges or corners.

Do not pull/run machine over cord. Keep cord away from heated surfaces.

Connect to a properly grounded outlet. See Grounding Instructions.

SAVE THESE INSTRUCTIONS

CHEYENNE 86038850 03/08/07 2-1

HAZARD INTENSITY LEVEL

The following symbols are used throughout this guide as indicated in their descriptions:

HAZARD INTENSITY LEVEL

There are three levels of hazard intensity identified by signal words -WARNING and CAUTION and FOR

SAFETY. The level of hazard intensity is determined by the following definitions:

!

WARNING

WARNING - Hazards or unsafe practices which COULD result in severe personal injury or death.

!

CAUTION

CAUTION - Hazards or unsafe practices which could result in minor personal injury or product or property damage.

FOR SAFETY: To Identify actions which must be followed for safe operation of equipment.

Report machine damage or faulty operation immediately. Do not use the machine if it is not in proper operating condition. Following is information that signals some potentially dangerous conditions to the operator or the equipment. Read this information carefully. Know when these conditions can exist. Locate all safety devices on the machine. Please take the necessary steps to train the machine operating personnel.

FOR SAFETY:

DO NOT OPERATE MACHINE:

Unless Trained and Authorized.

Unless Operation Guide is Read and understood.

In Flammable or Explosive areas.

In areas with possible falling objects.

WHEN SERVICING MACHINE:

Avoid moving parts. Do not wear loose clothing; jackets, shirts, or sleeves when working on the machine. Use manufacturer approved replacement parts.

2-2 CHEYENNE 86038850 03/08/07

GROUNDING INSTRUCTIONS

THIS PRODUCT IS FOR COMMERCIAL USE

ONLY.

ELECTRICAL:

In the USA this machine operates on a standard 15 amp 115V, 60 hz, A.C. power circuit . The amp, hertz, and voltage are listed on the data label found on each machine.

Using voltages above or below those indicated on the data label will cause serious damage to the motors.

EXTENSION CORDS:

If an extension cord is used, the wire size must be at least one size larger than the power cord on the machine, and must be limited to 50 feet

(15.5m) in length.

GROUNDING INSTRUCTIONS:

This appliance must be grounded. If it should malfunction or break down, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This appliance is equipped with a cord having an equipment-grounding conductor and grounding plug. The plug must be inserted into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

This appliance is for use on a nominal 120-volt circuit, and has a grounded plug that looks like the plug in “Fig. A”. A temporary adaptor that looks like the adaptor in “Fig . C” may be used to connect this plug to a 2-pole receptacle as shown in “Fig. B”, if a properly grounded outlet is not available. The temporary adaptor should be used only until a properly grounded outlet

(Fig. A) can be installed by a qualified electrician. The green colored rigid ear, lug, or wire extending from the adaptor must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adaptor is used, it must be held in place by a metal screw.

CHEYENNE 86038850 03/08/07

Improper connection of the equipmentgrounding conductor can result in a risk of electric shock. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the appliance - if it will not fit the outlet, have a proper outlet installed by a qualified

electrician.

2-3

TECHNICAL SPECIFICATIONS

ITEM DIMENSION/CAPACITY

Electrical 115V 60Hz

Electric Vacuum Motor DUAL 2 STAGE (C2, C2H)

DUAL 3 STAGE (C3, C3HP, CHPH)

Solution Pump

Solution Capacity

Recovery Capacity

100PSI (C2, C3, C2H)

200PSI (C3HP, CHPH)

16 gal. (60.6L)

16 gal. (60.6L)

Dimensions – Weight (Empty)

Dimensions - Length

Dimensions - Height

Dimensions - Width

Power Cable

98 lbs. (44.5kgs)

29 in. (73.6cm)

36 in. (91.4cm)

21 in. (53.3cm)

25 ft. (7.6m)

3-1

10/29/01

CHEYENNE 86038850 03/08/07

Vacuum Inlet

Solution Outlet

Solution Tank

Heat Models

ONLY

Mounted next to valve control on manifold plate, located to rear of machine.

Solution and Vacuum

Tank Lid

CONTROLS

Water Pump

Vacuum

Cheyenne HP

ONLY

Vacuum #2

Water Pump

Vacuum #1

Vacuum Tank

Heater

(Optional Accessory)

Optional Equipment:

86000600 – PRV NO. 89226 Deluxe Professional Wand

86260790 – PRV NO. 39604 Hose Asm, 2” Vac/Sol 25ft

CHEYENNE 86038850 03/08/07

Base Assembly

3-2

MACHINE OPERATIONS

PRE-RUN INSPECTION

1. Check all fittings and connectors for proper assembly.

2. Check all hoses for leaks. Repair or replace any damaged hoses.

3. Check power cord(s) for any damage. If damaged, replace.

EQUIPMENT SET-UP

1. Plug power cord from machine into properly grounded wall outlet.

2. Turn vacuum motor switch on and off to make sure there is electrical power at machine.

3. Connect vac hose to machine. Slide the swivel cuff over the outlet on the tank.

4. Connect the hose to your machine and wand. Pull back the knurled collar on the quick

disconnect coupler and push onto the connection

on the chassis. To avoid leaks, check to be that

a positive connection was made.

5. Pour clean, hot water into the solution tank.

To avoid possible tank distortion, water

temperature must not exceed 140 F (60C).

6. Add a non-foaming cleaning solution concentrate, for use in hot water extractors at the proportions noted on the container (See list below), into solution tank.

7. Turn pump and vacuum switch(s) to the on position.

8. Start cleaning.

! WARNING

To prevent possible disease hazard, before attempting to clean bodily fluids spills, you must kill any viruses, germs or bacteria present in the bodily fluid.

SUITABLE INCOMPATIBLE

CHEMICALS CHEMICALS

Clorox II Bleach*

Detergents Carbon

Hydroxides Clorox*

Oxygen Bleaches Chlorinated Bleaches

Sta-Puf Fabric

Aromatic Hydrocarbons

D-Limonene

CLEANING & EMPTYING TANKS

!

WARNING

Always use defoamer if foaming occurs. Foam will suspend large particles which may damage vacuum as well as allow liquid into the vacuum

motor without activating the float shutoff.

1. Before proceeding, make certain that the nozzle is functioning properly. a. To check, hold the wand about one foot above the surface to be cleaned and open the wand valve. A full spray should be observed from the nozzle. b. If the nozzle is not showing a full spray pattern, adjust nozzle for proper pattern, clean, or replace nozzle.

2. Normally, chemical is applied on the push stroke while vacuuming is done on the pull stroke. For heavily soiled carpets the hand tool may be used in the scrubbing manner, applying chemical in both the push and pull stroke.

A LWAYS FINISH UP AN AREA WITH A VACUUM PULL

STROKE .

3. When cleaning, keep the working opening

(wand mouth) flat on the surface being cleaned.

Keep the wand moving when the valve is open.

4. The shutoff float inside the recovery tank will impede the vacuum flow when the tank is full.

When this occurs, empty the recovery tank. Do this by opening the dump valve located at the back of the machine. NOTE: Dispose of waste in a proper manner which would not violate any

Local, State or Federal law.

5. Once the recovery tank has been emptied, you may once again proceed with cleaning

!

CAUTION

Operating Vacuum after shutoff has activated could draw water directly into the vac motor. This will cause damage to the motor, therefore voiding your warranty.

!

CAUTION

A LWAYS TEST CARPET FOR COLOR FASTNESS IN AN

INCONSPICUOUS PLACE . Also, to avoid prolonged drying times, do not spray too much solution in any one area.

!

WARNING

Perchlorethylene (perc)

Phenols

Trichlorethylene

*Registered Trademark

3-3 CHEYENNE 86038850 03/08/07

Before making any adjustments or performing any maintenance to your machine, disconnect

the power cord from the electrical source.

SHUT DOWN AND STORAGE

1. Turn Switch OFF. Empty recovery tank completely and rinse several times to remove any dirt or debris that may be left behind.

2. Drain any unused cleaning solution from solution tank and rinse with clean water to remove any suds left behind by the cleaning chemicals.

NOTE: Dispose of waste in a proper manner which would not violate any Local, State or

Federal law

3. Run a small amount of clean water through pump if chemicals were used. This will help insure the life of your pump.

4. Check the spray jet on the cleaning tool for full spray pattern and inspect vac head for any obstructions.

5. Remove as much moisture from system before storing in cold climates. Excess water may freeze during storage and crack internal components, causing damage to the unit.

MACHINE OPERATIONS

CHEYENNE 86038850 03/08/07 3-4

MAINTENANCE

DAILY MAINTENANCE

Unplug power cord(s) before servicing or making any repairs.

1. Flush the entire system, including floor tool, hand tool, etc., with 1 to 3 gallons of clean, hot water.

2. Vacuum out the solution tank.

3. Rinse tank with fresh water. Periodically inspect the recovery tank and decontaminate if necessary, using a Hospital Grade Virucide or a

1-10 bleach to water solution. Wastewater should be disposed of properly.

4. Occasionally check filter screen at the bottom of the solution tank and rinse clean with hot water if necessary.

5. Inspect hoses for wear. Frayed or cracked hoses should be replaced to avoid vacuum or solution pressure loss.

6. Inspect power cord for wear or damage. This cable will lie on wet carpet. To prevent electrical shock replace cords that are frayed or have cracked insulation immediately.

7. Clean all dirt and obstructions from drain valve and gaskets to prevent possible leakage and premature wear.

8. Run clean water through solution pump when work is complete.

9. Empty both tanks and rinse, run vacuum (s) for at least one minute to dry motor(s).

10. Store with access covers removed to allow tanks to dry.

PERIODIC MAINTENANCE

1. Twice a month, flush a white vinegar solution

(one quart vinegar to two gallons water) or antibrowning solution (mixed as directed) through the extractor. This will prevent build-up of alkaline residue in the system.

2. If spray jet becomes clogged, remove the spray tip, wash it thoroughly, and blow dry. NOTE: D O

NOT USE PINS , WIRE , ETC . TO CLEAN NOZZLE AS

THIS COULD DESTROY THE SPRAY PATTERN .

3. Apply silicone lubricant to solution nipple.

4. Periodically inspect all hoses, electrical cable and connections on your machine. Frayed or cracked hoses should be repaired or replaced to eliminate vacuum or solution pressure loss. If the cable insulation on the power cord is broken or frayed, repair or replace immediately. Don’t take chances with electrical fire or shock.

5. Clean outside of all tanks and check for damage.

4-1

CHEYENNE 86038850 03/08/07

MONTHLY MAINTENANCE

1. Check all bearings for noise and wear.

2. Check all gaskets for wear and leakage.

3. Check pump pressure; observe spray pattern and check gauge if necessary.

4. Check overall performance of machine.

SEMI-ANNUALLY

1. Check vacuum motor brushes.

LUBRICATION

For hose fitting lubrication, use a light silicone lubricant which will not damage o-rings.

STORAGE

Thoroughly clean machine if it is to be stored.

Protect this machine from freezing while in storage.

MAINTENANCE

Only qualified maintenance personnel are to perform the following repairs.

SOLUTION PUMP REPLACEMENT

1. Turn off all switches and unplug the machine.

2. Tip recovery tank to gain access to solution tank.

3. Remove solution hoses from fittings on pump.

Disconnect wires.

4. Remove the screws that fasten the pump to the frame.

5. Reverse process to install new replacement pump.

VACUUM MOTOR REPLACEMENT

1. Turn off all switches and unplug machine.

2. Tip recovery tank to expose vacuum (s).

3. Locate the proper vacuum motor wires and disconnect.

4. Unfasten screws holding vacuum to vac plate.

Remove the vacuum motor.

5. Reverse process to install vacuum motor replacement.

Vacuum Motor Carbon Brushes Replacement (Windsor)

End Cap

Carbon

Brushes

WARNING: The green ground wire must be attached for safe operation.

See wiring diagram.

Vacuum Motor Carbon Brushes Replacement (Ametek)

End Cap

Carbon

Brushes

WARNING: The green ground wire must be attached for safe operation.

See wiring diagram.

Note: When replacing carbon brushes loosen wire terminal

BEFORE removing screws on bracket.

Wire

Terminal

Note:

Place stop in groove.

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Wire Terminal

If armature commutator is grooved, extremely pitted or not concentric, the motor will need to be replaced or sent to a qualified service center.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

Important:

These brushes wear quicker as the length shortens due to increased heat. Spring inside brush housing will damage motor if brushes are allowed to wear away completely.

3/8 (9.5mm)

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

3

8

[9.5mm]

Periodically check the length of the carbon brushes. Replace both carbon brushes when either is less than 3/8" (9.5mm) long.

CHEYENNE 86038850 03/08/07 4-2

MAINTENANCE

PUMP REPLACEMENT PARTS FOR SHURFLO 100 PSI (250-64A)

86161980 – PRV NO. 250-67

Switch Asm

Pump Head Replacement

86251040

PRV NO. 65187

Bypass Valve Asm

86258830

PRV NO. 84161

Diaphragm

86235100

PRV NO. 29206

PUMP REPLACEMENT PARTS FOR FLOJET 100 PSI 86251110 – PRV NO. (65219)

DIAPHRAGM

86235120

PRV NO. 29219

86258860

PRV NO. 84166

86251090

PRV NO. 65204

PUMP HEAD

VALVE ASM

PUMP REPLACEMENT KITS

200 PSI PUMPTEC

CAM & BEARING KIT

86201170

PRV NO. 250-79G

86247360

PRV NO. 53245

MOTOR

VALVE & O-RINGS KIT

86201160

PRV NO. 250-79F

PLUNGER & SEALS KIT

86201150

PRV NO. 250-79E

4-3 CHEYENNE 86038850 03/08/07

MAINTENANCE

PRESSURE REGULATOR

For best results with the pressure regulator, we recommend that you clean and lubricate the piston and u-cup with Superlube lubricant monthly or when pressure drop seems excessive.

1. Turn unit off before lubricating.

2. Remove cap, spring and spring retainer plate.

3. With fingertips remove piston and u-cup.

4. Wipe piston and u-cup clean of any film or scale.

5. Lubricate the piston and u-cup with Superlube.

7. With pump ON, re-adjust pressure regulator for normal operation.

LUBRICATE U-CUP WITH SUPERLUBE MONTHLY.

U-CUP

SPRING RETAINER PLATE

OUT

IN PISTON

SPRING

(GOLD - 125 PSI)

(GREEN - 200 PSI)

CAP

CHEYENNE 86038850 03/08/07 4-4

TROUBLESHOOTING

PROBLEM CAUSE SOLUTION

Loss of Power

Dead electrical circuit

Faulty power cord

Check building circuit breaker or fuse box.

Replace

Equipment not grounding Follow grounding instructions exactly

Electrical shock

Vac motor speed varies or doesn’t run

Receptacle not grounded Contact an electrician to check building’s wiring

Internal wiring problem

Have a trained service technician check machine’s wiring

Worn motor brushes

Motor worn out

Faulty switch

Loose vacuum dome

Replace

Replace

Replace

Center and seal dome over tank

Loss of vacuum

Crack in dome of poor joint Replace or repair using acrylic plastic cement only

Lint or dirt clogging

With power off clean screen vacuum screen

Loose cuffs on vacuum hose

Vac motor seals leaking

Tighten cuffs turning counterclockwise

Replace

Floor tool vac chamber clogged

Vac motor, hose, or dome gasket

Wash out with hose. Pick lint out with a wire

Replace

Pump inlet screen plugged Clean inlet screen

Press trigger to open valve on cleaning wand to

Pump air locked relieve air

Pump runs no solution

Pump runs, loss of pressure

Pump will not run

Solution hose fitting hard to connect

Carpet not getting clean

Carpet too wet

Carpet browning

Solution not flowing properly

Internal or external solution line damaged and leaking

Internal pump components wearing out

Check BPR for particles or cuts in seals

Unit not plugged in

Loose wiring

Corrosion on fittings.

Severe soil conditions

Replace

Replace, see pump kit components (Pg 4-3)

Take piston from BPR and lubricate with Superlube.

If problem still exists change BPR.

Connect unit to 3 prong grounded outlet

See dealer

Clean with steel wool. Soak in acetic acid (white vinegar). Lubricate lightly with silicone base lubricant.

Make several passes at right angles to each other.

Use a pre-spray.

Over saturation

Leaving carpet too wet

Too much chemical

Light carpet with no brown prevention

Check solution wand. Make several passes without spray

Check for loss of vac pressure

Check label for correct solution concentration

Go over carpet with browning prevent only

Solution hose connection Check for positive connection

Faulty pump Repair or replace

Faulty floor tool valve

Faulty pump switch

Repair or replace

Repair

4-5 CHEYENNE 86038850 03/08/07

THIS PAGE LEFT BLANK INTENTIONALLY

CHEYENNE 86038850 03/08/07 4-6

BASE GROUP PARTS

9

7

5

6

8

8

6

7

1

6

4

5

3

2

5-1 CHEYENNE 86038850 03/08/07

BASE PARTS LIST

REF PART NO. PRV NO. QTY DESCRIPTION

1 86010710 87080

2 86103460 57196

3 86202250 040-06

4 86010760 87142

5 86279130 87083

6 86006760 70305

7 86199430 040-03

8 86270830 57023

2

2

2

2

6

4

2

2

WASHER, .5 X 1.25 FLAT GR8 PLT

NUT, 1/2 PUSH-ON DOME CAP

WHEEL 8” BLK CENTERED HUB

WASHER, .344 X .69 X .066 FLAT PLT

WASHER, 5/16 SPLIT LOCK PLTD

SCR, 5/16-18 X 3/4 HHCS

CASTER SWIVEL 4”

NUT, 5/16-18 HEX NYLOCK SS

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-2

SOLUTION TANK GROUP

17

16

15

14

13

18

19

12

11

10

9

1

2

3

4

5

6

7

5-3 CHEYENNE 86038850 03/08/07

SOLUTION TANK PARTS LIST

REF PART NO. PRV NO.

2 86005720 57106 2 NUT, 8-32 W/ STAR WASHER PLTD

3 86042400 56-502126 1 NIPPLE ASSEMBLY, QD MOUNT

4 86197370 31017

5 86161650 39598

1

1

ELBOW, 1/4 FPT X 1/4 FPT

HOSE, HP 42. 1/4MPT X 1/4MPT

9 86192840 290-08

10 86197940 40027

11 86197940 70744

12 86199970 120-08

13 86279610 87190

14 86005810 57245

15 86005580 56012

16 86020650 70051

QTY DESCRIPTION

1

1

4

1

4

4

1

2

STRAINER, 1/4 NPT 50 MESH

HOSEBARB, 3/8MPT X 1/2 90D DL

SCR, 1/4-20 X 1 PFH BLK SS

HANDLE, MACHINE BLACK

WASHER, SEAL 5/8 OD NEOPRENE

NUT, 1/4-20 HEX NYLOCK SS

NIPPLE, 1/4 FPT QD

SCR, 8-32 X 1/2 PPHMS NP

17 86161800 46-802531 1 LATCH, CONCEALED KEEPER

18 86161960 70222 3 SCR, #8 X 1/2 PPHST BLK

19 86279190 87095 3 WASHER, #10 FLAT PLTD

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07

5-4

PUMP GROUP

100 PSI NO HEAT

2 ST VAC

20

13

24A

24B

17

17

18

12

2 1

2 2

2 3

1 1

1 0

9

13

16

8

1

2

3

4

5

6

7

3

TO SOLUTION

TANK UPPER SPIN

FITTING (86197630,

PRV NO. 40042)

15

14

13

TO SOLUTION

TANK (86197550,

PRV NO. 40014)

5-5

CHEYENNE 86038850 03/08/07

PUMP PARTS LIST

100 PSI NO HEAT

2 ST VAC

2

3

4

5

6

7

8

11

12

13

14

15

16

17

18

20

21

86272730

86002750

86000950

86199540

86256240

86199310

86005670

86005700

86164130

86222770

86280970

86270990

86278980

86001550

86276240

86280800

86197560

66017

70088

70532

060-04A

73505

110-14

57040

57104

82859

20042

39233

57090

87014

40043

70614

39031

40015

2

1

2

1

1 STRAIN RELIEF, 1/2 NPT TRUMPET

1 CAP PLUG 7/8”

1

2

1

6

1

2

2

2

2

1

1

PLUG, 1/4 BASS PIPE

SCR, 10-32 X 1/2 PPHMS SS

SCR, 10-32 X 1/2 PPHMS BLK

CORD ASM, 14/3 SJT X 25’ BLK

NUT, 1/2 NPT CONDUIT

NUT, 10-32 W/STAR WASHER PLTD

HOSE, 1/2 NYLOBRAID 20”

CLAMP, 3/8 HOSE (D-SLOT)

HOSE 3/8 RUBBER X 17”

NUT, 10-32 NYLOCK SS

WASHER, #8 INT. STAR

HOSEBARB, 3/8MPT X 3/8 90D

SCR, 10-32 X 1 1/8 PPHMS SS

HOSE, 3/8 RUBBER X 24”

HOSEBARB, 1/4FPT X 3/8

23 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T

24A 86201430 250-64A 1 SHURFLO 100 PSI PUMP DEMAND

24B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)

SERIAL NO.

FROM

NOTES:

1000132734

CHEYENNE 86038850 03/08/07 5-6

PUMP GROUP

100 PSI NO HEAT

3 ST VAC

19

12

16

23A

23B

16

11

20

10

9

21

12

17

15

22

8

1

7

2

3

5

4

TO SOLUTION TANK

UPPER SPIN FITTING

(86197630, PRV NO. 40042)

4

6

14

13

12

TO SOLUTION TANK

(86197550, PRV NO.

40014)

5-7 CHEYENNE 86038850 03/08/07

PUMP PARTS LIST

100 PSI NO HEAT

3 ST VAC

2

3

4

5

6

7

10

11

12

13

14

15

16

17

19

20

86272730

86002750

86006950

86199540

86256240

86005670

86005700

86282720

86222770

86280970

86270990

86278980

86001550

86276240

86280800

86197560

66017

70088

70532

060-04A

73505

57040

57104

82859

20042

39233

57090

87014

40043

70614

39031

40015

2

1

4

2

2

2

2

1

6

1

2

2

2

2

1

1

PLUG, 1/4 BASS PIPE

SCR, 10-32 X 1/2 PPHMS SS

SCR, 10-32 X 1/2 PPHMS BLK

CORD ASM, 14/3 SJT X 25’ BLK

STRAIN RELIEF, 1/2 NPT TRUMPET

NUT, 1/2 NPT CONDUIT

NUT, 10-32 W/STAR WASHER PLTD

HOSE, 1/2 NYLOBRAID 20”

CLAMP, 3/8 HOSE (D-SLOT)

HOSE 3/8 RUBBER X 17”

NUT, 10-32 NYLOCK SS

WASHER, #8 INT. STAR

HOSEBARB, 3/8MPT X 3/8 90D

SCR, 10-32 X 1 1/8 PPHMS SS

HOSE, 3/8 RUBBER X 24”

HOSEBARB, 1/4FPT X 3/8

22 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T

23A 86201430 250-64A 1 SHURFLO 100 PSI PUMP DEMAND

23B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)

SERIAL NO.

FROM

NOTES:

1000132734

CHEYENNE 86038850 03/08/07 5-8

PUMP GROUP

100 PSI WITH HEAT

2 ST VAC

22

21

14

18

25A

25B

18

19

17

13

12

11

14

23

10

9

1

2

3

5

4

8

7

5

6

TO SOLUTION

TANK UPPER SPIN

FITTING (86197630 -

PRV NO. 40042)

16

15

14

TO SOLUTION

TANK (86197550 -

PRV NO. 40014)

5-9 CHEYENNE 86038850 03/08/07

PUMP PARTS LIST

100 PSI WITH HEAT

2 ST VAC

2

3

5

6 86199540 060-04A 1 CORD ASM, 14/3 SJT X 25’ BLK

7 86256240 73505

8

9

12

13

14

15

16

17

18

19

21

22

86005590

86005580

86006950

86199310

86005670

86005700

86164130

86222770

86280970

86270990

86278980

86001550

86276240

86280800

86157620

56014

56012

70532

110-14

57040

57104

82859

20042

39233

57090

87014

40043

70614

39031

40015

2

2

4

1

1

1

2

1

6

1

2

2

2

2

1

1

NIPPLE, 1/4 CLOSE

NIPPLE, 1/4 FPT QD

SCR, 10-32 X 1/2 PPHMS BLK

STRAIN RELIEF, 1/2 NPT TRUMPET

CAP PLUG 7/8”

NUT, 1/2 NPT CONDUIT

NUT, 10-32 W/STAR WASHER PLTD

HOSE, 1/2 NYLOBRAID 20”

CLAMP, 3/8 HOSE (D-SLOT)

HOSE 3/8 RUBBER X 17”

NUT, 10-32 NYLOCK SS

WASHER, #8 INT. STAR

HOSEBARB, 3/8MPT X 3/8 90D

SCR, 10-32 X 1 1/8 PPHMS SS

HOSE, 3/8 RUBBER X 24”

HOSEBARB, 1/4FPT X 3/8

24 86279530 87173 1 WASHER, .765 ID X 1.31 OD X .09 T

25A 86201430 250-64A 1 SHURFLO 100PSI PUMP DEMAND

25B 86251110 65219 1 PUMP, 115V 100PSI BYPASS W/SW (FLOJET)

SERIAL NO.

FROM

NOTES:

1000132734

CHEYENNE 86038850 03/08/07

5-10

PUMP GROUP

200 PSI NO HEAT

3 ST VAC

ITEM 10

20

23

1

2

25

4

3

5

24

12

13

11

14

SOLUTION

TANK

28

18

17

13

9

15

22

21

8

4

16

(TO SOLUTION TANK STRAINER)

7

6

18

19

5-11

27

CHEYENNE 86038850 03/08/07

PUMP PARTS LIST

200 PSI NO HEAT

3 ST VAC

2

3

4

5

6

8

9

10

11

26

27

28

86272730

86006590

86006950

86199540

86256240

86197370

86005670

86286040

86005700

86279530

86270990

86162070

66017

70088

70532

060-04A

73505

31017

57040

84182

57104

87173

57090

84198

2

1

2

2

2

1

2

1

2

ELBOW, 1/4FPT X 1/4FPT

NUT, 1/2 NPT CONDUIT

VALVE BPR 200 PSI

NUT, 10-32 W/STAR WASHER PLTD

13 86233150 20042

14 86282720 82859

15 86161640 39597

16 86280810 39032

4 CLAMP, 3/8 HOSE (D-SLOT)

1 HOSE, 1/2 NYLOBRAID X 20”

1 HOSE, HP 15.0 1/4MPT X 1/4MPT

1 HOSE, 3/8 RUBBER X 15”

17 86197220 40014

18 86199640 030-16

1 HOSEBARB, 1/4 MPT X 3/8 DL

2 ELBOW, 1/4 NPT STREET LONG 90D

19 86200150 151-38D 1 HOSE, PULSE 27.0 1/4 MPTX1/4MPT

20 86272730 66017 1 PLUG, 1/4 BRASS PIPE

21 86010650 87018

22 86276240 70614

23 86201130 250-79

24 86197350 22014

2 WASHER, #10 X 9/16 OD

2 SCR, 10-32 X 1 1/8 PPHMS SS

1 PUMPTEC 200PSI PUMP & MOTOR

1 COUPLER, 1/4F HEX

1

2

1

PLUG, 1/4 BRASS PIPE

SCR, 10-32 X 1/2 PPHMS SS

SCR, 10-32 X 1/2 PPHMS BLK NP

CORD ASM, 14/3 SJT X 25’ BLK

STRAIN RELIEF, 1/2 NPT TRUMPET

WASHER, .765ID X 1.31OD X .09T SS

NUT, 10-32 HEX NYLOCK SS

VALVE, BPR 200 PSI BRASS

SERIAL NO.

FROM

NOTES:

INCLUDES

62967

CHEYENNE 86038850 03/08/07 5-12

PUMP GROUP

200 PSI WITH HEAT

7.2 3 ST VAC

ITEM 11

22

1

2

3 4

28

27

5

6

8

26

29

25

10

8

9

13 12

14

30

SOLUTION

TANK

15 17

18

24

23

16

14

19

(TO SOLUTION TANK STRAINER)

7

17

21

5-13

20

CHEYENNE 86038850 03/08/07

PUMP PARTS LIST

200 PSI WITH HEAT

7.2 3 ST VAC

REF PART NO.

2

3

4

5

6

8

9

10

11

28

29

30

86005590

86005580

86161770

86199310

86199530

86006950

86197370

86005670

86286040

86279530

86256240

86162070

PRV NO. QTY DESCRIPTION

56014

56012

500452

110-14

060-04

70532

31017

57040

84182

87173

73505

84198

2

2

1

1

1

4

1

1

1

13 86005700 57104

14 86233150 20042

15 86222770 82859

16 86161640 39597

2

4

1

1

NUT, 10-32 W/STAR WASHER PLTD

CLAMP, 3/8 HOSE (D-SLOT)

HOSE, 1/2 NYLOBRAID X 20”

HOSE, HP 15.0 1/4MPT X 1/4MPT

17 86199640 030-16 2

ELBOW, 1/4 NPT STREET LONG

90D

18 86156850 40014

19 86280810 39032

1 HOSEBARB, 1/4MPT X 3/8 DL

1 HOSE, 3/8 RUBBER X 15”

20 86270990 57090 2 NUT, 10-32 HEX NYLOCK SS

21 86200150 151-38D 1

HOSE, PULSE 27.0 1/4MPT X

1/4MPT

22 86272730 66017

23 86010650 87018

24 86276240 70614

25 86201130 250-79

26 86197350 22014

1 PLUG, 1/4 BRASS PIPE

2 WASHER, #10 X 9/16 OD

2 SCR, 10-32 X 1 1/8 PPHMS SS

1 PUMPTEC 200PSI PUMP & MOTOR

1 COUPLER, 1/4F HEX

1

1

1

NIPPLE, 1/4 CLOSE

NIPPLE, 1/4 FPT QD

LABEL HEATER

CAP PLUG 7/8”

CORD ASM, 12/ SJT X 25’ BLK

SCR, 10-32 X 1/2 PPHMS BLK NP

ELBOW, 1/4FPT X 1/4FPT

NUT, 1/2 NPT CONDUIT

VALVE, BPR 200 PSI

WASHER, .765ID X 1.31OD X .09T

STRAIN RELIEF, 1/2 NPT TRUMPET

VALVE, BPR 200 PSI BRASS

SERIAL NO.

FROM

NOTES:

INCLUDES 62967

CHEYENNE 86038850 03/08/07 5-14

RECOVERY TANK-2 STAGE GROUP

10

13

11

12

2

1

11

3

4

9

8

5

7

6

5-15 CHEYENNE 86038850 03/08/07

RECOVERY TANK-2 STAGE PARTS LIST

REF PART NO. PRV NO. QTY DESCRIPTION

1 86161910 48-941382 1 PLATE, SWITCH MODEL 2

2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER

3 86043410 56-502173 1 ASSY, EXH DCT FLNG PRT405

4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK

5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40

6 86161460 15-808123 1 DUMP VALVE, 2’

7 86237770 35256

8 86033320 78474

1

1

GASKET, DUMP VALVE

VAC STACK ASM, 6 GAL PORTABLE

9 86161510 43-807109 1 GASKET, VAC TANK

10 86161820 56-502156 1 LID, VACUUM TANK

11 86161960 70222

12 86199840 090-12A

6

1

SCR, #8 X 1/2 PPHST BLK

FLOAT CAGE ASSY COMPLETE

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-16

RECOVERY TANK-3 STAGE GROUP

10

13

11

12

2

1

11

3

4

9

8

5

7

6

5-17 CHEYENNE 86038850 03/08/07

RECOVERY TANK-3 STAGE PARTS LIST

REF PART NO. PART NO. QTY DESCRIPTION

1 86161920 48-941383 1 PLATE, SWITCH MODEL 2

2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER

3 86042360 56-502143 1 BRKT, CORD WRAP NO HEATER

4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK

5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40

6 86161460 15-808123 1 DUMP VALVE, 2’

7 86237770 35256

8 86033320 78474

1

1

GASKET, DUMP VALVE

VAC STACK ASM, 6 GAL PORTABLE

9 86161510 43-807109 1 GASKET, VAC TANK

10 86161820 56-502156 1 LID, VACUUM TANK

11 86161960 70222

12 86199840 090-12A

6

1

SCR, #8 X 1/2 PPHST BLK

FLOAT CAGE ASSY COMPLETE

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-18

RECOVERY TANK- 2 STAGE WITH HEAT GROUP

10

13

11

12

2 1

11

3

4

9

8

5

7

6

5-19 CHEYENNE 86038850 03/08/07

RECOVERY TANK-2 STAGE-WITH HEAT PARTS LIST

REF PART NO. PART NO. QTY DESCRIPTION

1 86161910 48-941382 1 PLATE, SWITCH MODEL 2

2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER

3 86042340 50-501882 1 BRKT, HEATER MOUNT

4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK

5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40

6 86161460 15-808123 1 DUMP VALVE, 2’

7 86237770 35256

8 86033320 78474

1

1

GASKET, DUMP VALVE

VAC STACK ASM, 6 GAL PORTABLE

9 86161510 43-807109 1 GASKET, VAC TANK

10 86161820 56-502156 1 LID, VACUUM TANK

11 86161960 70222

12 86199840 090-12A

6

1

SCR, #8 X 1/2 PPHST BLK

FLOAT CAGE ASSY COMPLETE

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-20

RECOVERY TANK- 3 STAGE WITH HEAT GROUP

10

13

11

12

2 1

11

3

4

9

8

5

7

6

5-21 CHEYENNE 86038850 03/08/07

RECOVERY TANK-3 STAGE-WITH HEAT PARTS LIST

2 86162010 32-900195 3 SWITCH, DPST, LIGHTED ROCKER

3 86042340 50-501882 1 BRKT, HEATER MOUNT

4 86275210 70384 4 SCR, 1/4-20 X 1/2 PHTR BLK

5 86161470 11-800444 1 ELBOW, 2” 45D PVC SCH40

6 86161460 15-808123 1 DUMP VALVE, 2’

7 86237770 35256 1 GASKET, DUMP VALVE

8 86033320 78474 1 VAC STACK ASM, 6 GAL PORTABLE

9 86161510 43-807109 1 GASKET, VAC TANK

10 86161820 56-502156 1 LID, VACUUM TANK

11 86161960 70222 6 SCR, #8 X 1/2 PPHST BLK

12 86199840 090-12A 1 FLOAT CAGE ASSY COMPLETE

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-22

VACUUM GROUP (2 STAGE)

5-23

8

9

6

3

12

2

6

11

7

4

1

2

3

10

4

6

5

CHEYENNE 86038850 03/08/07

VACUUM GROUP-2 STAGE PARTS LIST

REF PART NO.

1

2

3

4

-

-

86005810

86003760

86201970

86202040

86202070

86135320

PRV NO.

57245

35166

065-92

360-04A

360-04B

140687

QTY DESCRIPTION

SERIAL NO.

FROM

NOTES:

3 NUT, 1/4-20 HEX NYLOCK SS

2 GASKET, VAC MTR

6

2

VAC SPACER 2 1/4 II STAGE

VAC MOTOR, 120V 5.7 2ST TD

- BRUSHES, VAC FOR 116392-00 SERVICE ONLY

- BRUSH SET, 120V VAC WINDSOR 1000121568 SERVICE ONLY

5 86007010 70663

6 86010630 87013

3 SCR, 1/4-20 X 3 1/4 HHCS PLT

9 WASHER, 1/4 ID X 5/8 OD SS

7 86005710 57105 3 NUT, 1/4-20 HEX W/ STAR WASHER

8 86042350 56-502084 1 BRKT, VAC MOUNT, DUAL 2 STG

9 86161520 43-807517 1 GASKET, VAC MTG.

10 86027140 75377 1 TANK, RECOVERY, CHEYENNE

11 86256480 70813

12 86273750 70011

3

3

STUD, 1/4-20 X 3.5 SS

SCR, 1/4-20 X 5/8 HHCS SS

CHEYENNE 86038850 03/08/07 5-24

VACUUM GROUP – 3 STAGE

5-25

8

9

6

11

2

7

12

6

3

4

10

1

2

3

4

6

5

CHEYENNE 86038850 03/08/07

VACUUM GROUP-3 STAGE PARTS LIST

REF PART NO. PRV NO. QTY DESCRIPTION

1 86005810

2 86003760

57245

35166

3 86201950 065-24E

4 86124130 53130

- 86135320

- 86135300

140687

140676

3 NUT, 1/4-20 HEX NYLOCK SS

2 GASKET, VAC MTR

6 VAC SPACER 3 1/8

2 VAC MOTOR, 120V 5.7 3ST W/O TB

- BRUSH SET, 120V VAC WINDSOR

- BRUSH SET, 120V 3ST VAC AMETEK

5 86216610

6 86010630

70062

87013

3 SCR, 1/4-20 X 4 HHCS GR5 PLTD

9 WASHER, 1/4 ID X 5/8 OD SS

7 86005710 57105 3 NUT, 1/4-20 HEX W/ STAR WASHER

8 86042320 56-502091 1

BRACKET, VACUUM MOUNT, 3

STAGE

9 86161520 43-807517

10 86027140 75377

11 86256490

12 86273750

70814

70011

1 GASKET, VAC MTG.

1 TANK, RECOVERY, CHEYENNE

3 STUD, 1/4-20 X 4.5 SS

3 SCR, 1/4-20 X 5/8 HHCS SS

SERIAL NO.

FROM

NOTES:

*

* SERVICE

ONLY

SERVICE

ONLY

CHEYENNE 86038850 03/08/07 5-26

VACUUM GROUP

SINGLE 7.2 3-STAGE

9

3

8

7

6

1

2

10

3

4

5

5-27 CHEYENNE 86038850 03/08/07

VACUUM GROUP-3 STAGE (7.2) PARTS LIST

REF PART NO. PRV NO. QTY DESCRIPTION

1 86005810 57245

2 86201940 065-24C

3 86010630 87013

4 86020710 70062

3 NUT, 1/4-20 HEX NYLOCK SS

3 VAC SPACER 2 1/2

18 WASHER, 1/4 ID X 5/8 OD SS

3 SCR, 1/4-20 X 4 HHCS GR5 PLTD

5 86202050 360-05A

6 86003760 35166

1 VAC, 117507-13 110V 3 ST 7.2

1 GASKET, VAC MTR

7 86042330 56-502092 1 BRACKET, VACUUM MOUNTING 7.2

8 86273750 70011 6 SCR, 1/4-20 X 5/8 HHCS SS

9 86161520 43-807517 1 GASKET, VAC MTG.

10 86027140 75377 1 TANK, RECOVERY CHEYENNE

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-28

HEATER GROUP

23

24

22

26

25

21

20

18

16

19

4

23

24

22

4

1 19

21

20

4

5

14

15

4

4

17

2

3

29

6

28

5-29

I

O

11

9

27

29

13

28

12

8

7

10

CHEYENNE 86038850 05/02/09

REF

21

22

23

24

17

18

19

20

25

26

27

28

29

13

14

15

16

9

10

11

12

5

6

7

8

1

2

3

4

HEATER GROUP Parts List

PART NO. PART NO. QTY DESCRIPTION

86161750 48-941396 LABEL, HEATER WARNING PROCHEM

86241010 41504 HOUSING, CAP OUTLET END NU

86245650 50776 LABEL, FOR SAFETY

86006790 70351 SCR, 10-32 X 3/8 HHTR W/STAR

86005700 57104 NUT, 10-32 W/STAR WASHER PLTD

86241470 41513 INSULATION, HEATER

86201790 130-14C 1 THERMOSTAT RESET 302

86201800 130-14 HEATER ELEMENT 110V

86162010 32-900195 SWITCH, DPST, LGHTD RCKR GRN

86246490 51041 LIGHT, 115V NEON INDICATOR

86171080 41503 HOUSING, CAP SWITCH END NU

86233480 22046 CLIP, NEON LAMP

86006180 66095 PLUG, 1/8 MPT HEX BRASS

86201810 130-14I THERMOSTAT W/SPADE LEADS

86264110 41514 INSULATION PAPER

86268800 88623 WIRE, 4” G/Y/14 76010 X 76010

86092890 41502 HOUSING ASM, HEATER PORT NU

86005670 57040 NUT, ½ NPT CONDUIT

86175890 11-800039 BUSH, ¼ x 1/8 BR

86180360 12-800040 ELL, 1/8P X 1/4T BR

86008920 80889 BOOT, RUBBER TERM. ISOLATOR

86183990 10-805393 HOS, 3/16 X 14-1/4(1/4FT) BS

86180340 12-800031 ELL, 1/4P X 1/4T BR

86002450 22015 COUPLER, ¼ QD

86256240 73505 STRAIN RELIEF, ½ NPT TRUMPET

86199530 060-04 CORD ASM, 12/ SJT X 25’ BLK

86326680 - HEATER CART, CASE WELDED

86200870 300-06A PAN HD SH MTL SCREW 6 X 3/16 B

86010650 87018 WASHER, #10 X 9/16 OD

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 06/09/09 5-30

TANK & LID PARTS

2

1

3

4

7

(86161800, PRV

NO. 46-802531)

Keeper)

6

3

5

5-31

CHEYENNE 86038850 03/08/07

TANK & LID PARTS LIST

REF PART NO. PART NO. QTY DESCRIPTION

2 86161960 70222

3 86006950 70532

4 SCR, #8 X 1/2 PPHST BLK

12 SCR, 10-32 X 1/2 PPHMS BLK NP

4 86161570 46-802530 2 HINGE, SOUTHCO C6-34

5 86161590 46-802540 2 HINGE, SOL. VAC TANK

6 86005720 57106

7 86020650 70051

2 NUT, 8-32 W/ STAR WASHER PLTD

2 SCR, 8-32 X 1/2 PPHMS NP

SERIAL NO.

FROM

NOTES:

CHEYENNE 86038850 03/08/07 5-32

LABEL & STRAP GROUP

3

1AB

2

5-33

CHEYENNE 86038850 03/08/07

REF

PART

NO.

PRV

NO.

QTY DESCRIPTION

500531 2

LABEL, PROCHEM

LOGO 6 X 1.75

500567 1

LABEL, CHEYENNE

MAIN

LABEL & STRAP PARTS LIST

SERIAL

NO.

NOTES:

10075210, PRV NO. C3, AND

10075220, C3HP ONLY

CHEYENNE 86038850 03/08/07 5-34

WIRE GROUP

100 PSI

2ST VAC

5-35 CHEYENNE 86038850 03/08/07

WIRE GROUP

100 PSI

3 ST VAC

CHEYENNE 86038850 03/08/07 5-36

WIRE GROUP

200 PSI

3 ST VAC

5-37

CHEYENNE 86038850 03/08/07

WIRE GROUP

200 PSI

7.2 3 ST VAC

CHEYENNE 86038850 03/08/07 5-38

WIRE GROUP - HEATER

INSULATION 86282790

PRV NO. 730129

WHITE WIRE 5"

BLACK WIRE 5"

GREEN WIRE 5"

86266250

PRV NO. 76064L

ON HTR

CORE

86266030

PRV NO. 76031

86266250

PRV NO. 76064L

5"

1

2

POWER SWITCH

4

5

86268800

PRV NO. 88623

86267560

PRV NO. 880300

THERMAL

SWITCH

ON HTR

CANISTER (130-14 I)

(130-14C)

86266030

SAFETY

SWITCH

86267560

86282800

PRV NO. 880300 PRV NO. 730314

4"

PRV NO. 76031

86266250

PRV NO. 76064L

T

E

R

H

E

A

5"

86282790

PRV NO. 730129

LIGHT

M

E

N

T

E

L

E

86282790

PRV NO. 730129

5"

5-39 CHEYENNE 86038850 03/08/07

advertisement