VTrak M-Class Product Manual

Replace Cooling Unit Fan – M300f/i/p and M200f/i/p

Cautions

• The Cooling Unit is NOT a hot-swappable device. Powerdown the VTrak before removing it.

• If power service has failed, do not remove the cooling unit if

the Controller’s Dirty Cache LED is flashing. See “Unsaved

Data in the Controller Cache” on page 289.

The blowers (scroll fans) in the cooling units are replaced as individual parts.

There are two fans in each cooling unit. No tools are required for this procedure.

Fan 1 LED Fan 2 LED

To replace a fan, do the following:

1.

Verify that the Fan LED is amber or red and note whether it is Fan 1 or 2.

See the diagram above.

2.

Power down the VTrak.

3.

Grasp the cooling unit handle and pull it toward you, as shown above.

4.

Pull the cooling unit out of the VTrak enclosure.

220

Chapter 6: Maintenance

An example of a VTrak cooling unit appears above.

Loosen the thumbscrew

Loosen the thumbscrew

5.

Loosen the thumbscrews (above). Retainers keep the thumbscrews in place.

6.

Grasp the top of the cooling unit near the thumbscrews and lift it away from the bottom.

221

VTrak M-Class Product Manual

7.

Separate the cooling unit sections to access the blowers.

Fan 2

Fan 1

Viewed from the inside (battery) end on the cooling unit, the left blower is

Fan 1, the right blower is Fan 2. From the LEDs (see the diagram on

page 215), you know which fan to replace.

8.

Lift the blower off the mounting pins and detach the electrical connector.

9.

Attach the electrical connector of the new blower and set it in place.

Be sure you set the blower on the mounting pins, as shown above.

222

Chapter 6: Maintenance

Be sure the blowers point outward, towards the handle, as shown above.

10. Place the top section of the cooling unit onto the bottom section.

11. Tighten the thumbscrews.

12. Carefully slide the cooling unit into the enclosure.

13. Press on the screen to seat the cooling unit (above). The handle will swing in as the cooling unit is properly seated.

14. Boot the VTrak and verify that the Fan LEDs are green.

This completes the fan replacement procedure.

223

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • High-performance, enterprise-class storage solution
  • Support for both Fibre Channel and iSCSI connectivity
  • Advanced features, such as RAID protection, snapshot capabilities, and thin provisioning

Related manuals

Frequently Answers and Questions

What is the Promise Technology VTrak M200i?
The Promise Technology VTrak M200i is a high-performance, enterprise-class storage solution that offers a range of features to meet the demanding needs of businesses of all sizes.
What types of connectivity does the VTrak M200i support?
The VTrak M200i supports both Fibre Channel and iSCSI connectivity.
What are some of the advanced features of the VTrak M200i?
The VTrak M200i includes a number of advanced features, such as RAID protection, snapshot capabilities, and thin provisioning.
What is the maximum storage capacity of the VTrak M200i?
The storage capacity of the VTrak M200i depends on the number of disk drives that are installed.
What types of disk drives can be used with the VTrak M200i?
The VTrak M200i supports a variety of disk drive types, including SATA, SAS, and SSD.

advertisement

Table of contents