Chapter 3
SAFETY DEVICES
WARM AIR BLOWER BREAKDOWN
If the blower stops for any reason, the stove automatically shuts down to prevent overheating.
FUME EXHAUSTER BREAKDOWN
If the exhauster stops, the electronic unit immediately prevents pellet feeding.
PELLET FEED MOTOR BREAKDOWN
If the motor stops, the stove continues to operate until the minimum cooling level is reached.
IGNITION FAILURE
If a fl ame is not developed during the ignition phase, the appliance automatically attempts ignition again, this time without pellet feeding.
If no fl ame develops also in this case, the appliance will signal “IGNITION FAILURE” on the display. When trying to re-ignite the machine, it will indicate “WAIT FOR COOL.” on the display. This function reminds
that before performing ignition, it must be ensured that the pot is completely free and clean.
TEMPORARY POWER FAILURE
The appliance will re-light automatically after a brief power failure. When the power goes off , the stove may emit a minute quantity of smoke inside the house for a period of 3 to 5 minutes.
THIS DOES NOT POSE ANY SAFETY RISK.
ELECTRICAL SAFETY
The stove is protected against violent power swings by a master fuse on the rear of the stove (2A 250V delayed).
EXHAUST FUME SAFETY
If the exhaust system fails, an electronic pressure switch stops the stove and an alarm is signalled.
PELLET OVERHEATING SAFETY
In case of overheating inside the pellet hopper, this safety device blocks stove operation; resetting is manual and must be performed by an authorized technician.
SAFETY DEVICES
9
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 WARNINGS AND SAFETY DEVICES
- 8 WHAT ARE PELLETS?
- 8 PELLET STORAGE
- 8 PELLET LOAD
- 9 SAFETY DEVICES
- 9 WARM AIR BLOWER BREAKDOWN
- 9 FUME EXHAUSTER BREAKDOWN
- 9 PELLET FEED MOTOR BREAKDOWN
- 9 IGNITION FAILURE
- 9 TEMPORARY POWER FAILURE
- 9 ELECTRICAL SAFETY
- 9 EXHAUST FUME SAFETY
- 9 PELLET OVERHEATING SAFETY
- 10 ASSEMBLY AND INSTALLATION INSTRUCTIONS
- 10 GLOSSARY
- 11 INSTALLATION
- 11 ADMISSIBLE INSTALLATIONS
- 11 PROHIBITED INSTALLATIONS
- 12 CONNECTION TO THE EXHAUST VENTING SYSTEM
- 12 EXHAUST CHANNEL OR PIPE
- 13 CHIMNEY OR SINGLE FLUE
- 15 CONNECTION TO THE FLUE AND COMBUSTION PRODUCT EXHAUST VENTING
- 15 CHIMNEY CAP
- 16 CONNECTION TO EXTERNAL AIR INTAKES
- 16 INSULATION, TRIMS, FACINGS, AND SAFETY PRECAUTIONS
- 16 NATIONAL, REGIONAL, PROVINCIAL AND MUNICIPAL LAWS
- 17 PRODUCT FUNCTIONALITY
- 17 CONTROL BOARD
- 17 LANGUAGE SELECTION
- 18 CURRENT DATE AND TIME ADJUSTMENT
- 18 BASIC INSTRUCTIONS
- 19 IGNITION
- 19 STOVE FUNCTIONING
- 19 NORMAL FUNCTIONING
- 20 SWITCH-OFF
- 21 REMOTE CONTROL
- 22 ROOM THERMOSTAT
- 22 DIGITAL THERMOSTAT (AS PER STANDARD)
- 22 MECHANICAL THERMOSTAT (OPTIONAL)
- 22 MECHANICAL THERMOSTAT INSTALLATION (OPTIONAL)
- 22 MECHANICAL THERMOSTAT FUNCTIONING
- 23 ACTUATOR)
- 24 USER PARAMETERS
- 24 OVEN FUNCTIONING MODES
- 25 NORMAL FUNCTIONING (NO TIMER)
- 25 TIMED FUNCTIONING (WITH TIMER)
- 26 NORMAL FUNCTIONING (NO TIMER)
- 26 TIMED FUNCTIONING (WITH TIMER)
- 26 WEEKLY PROGRAMMER
- 29 DAY-NIGHT TEMPERATURE FUNCTION
- 30 PELLET FEED ADJUSTMENT
- 32 CLEANING
- 33 CONNECTION TO THE FLUE
- 34 POT DIVIDER
- 35 PRODUCT DISPLAY TABLES
- 39 WARRANT