GPi 1700 Operation
Disconnecting the battery
When the battery is fully charged:
1. Disconnect the cable from the negative (-) terminals of the battery and the generator.
2. Disconnect the cable from the positive (+) terminals of the battery and the generator.
If the DC circuit breaker activates
The DC circuit breaker may activate while a battery is charging. This may occur for either of the following reasons:
Defective battery—check the battery before replacing the DC breaker
Excessive current draw from a large capacity battery or a totally discharged battery—use an AC battery charger to charge the battery instead of the generator.
2.16
Stopping the Generator
Before stopping
Check with other personnel on the jobsite and let them know that power is being turned off. Make sure that the power shutdown will not create any hazards by turning off devices such as pumps, heaters, or lights that may need to be kept on.
Stopping procedure
To stop the generator:
1. Switch off and disconnect all equipment from the generator.
2. Allow the generator to run at no load for approximately 3 minutes.
3. Turn the engine switch to the STOP position.
2.17
Emergency Shutdown Procedure
Procedure If a breakdown or accident occurs while the machine is operating, follow the procedure below:
1. Stop the engine.
2. Turn off the fuel supply.
3. Disconnect tools from the machine.
4. Allow the machine to cool.
5. Contact the rental yard or machine owner for further instructions.
wc_tx001234gb.fm
31
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 7 Signal Words Found in this Manual
- 8 Machine Description and Intended Use
- 9 Safety Guidelines for Operating the Machine
- 11 Operator Safety While Using Internal Combustion Engines
- 12 Guidelines for Service Safety
- 13 Label Locations
- 14 Machine Labels
- 17 Overview
- 17 Preparing the Machine for First Use
- 18 Features and Components
- 19 Lifting and Transporting
- 19 Installation
- 20 Power Requirements
- 21 Use of Extension Cords
- 22 Control Panel
- 24 Customer Connections
- 25 Grounding the Generator
- 26 Fueling the Machine
- 27 Before Starting
- 28 Starting the Generator
- 29 Using AC Power
- 30 Using DC Power
- 31 Stopping the Generator
- 31 Emergency Shutdown Procedure
- 32 Periodic Maintenance Schedule
- 34 Cleaning and Checking the Spark Plug
- 35 Cleaning the Air Cleaner Assembly
- 36 Changing the Engine Oil
- 37 Cleaning the Spark Arrester
- 38 Cleaning the Fuel Filter
- 39 Storing the Generator
- 43 Schematic Components
- 45 Engine
- 46 Generator Data