Stopping the Generator. Wacker Neuson GPi 1700


Add to my manuals
54 Pages

advertisement

Stopping the Generator. Wacker Neuson GPi 1700 | Manualzz

GPi 1700 Operation

Disconnecting the battery

When the battery is fully charged:

1. Disconnect the cable from the negative (-) terminals of the battery and the generator.

2. Disconnect the cable from the positive (+) terminals of the battery and the generator.

If the DC circuit breaker activates

The DC circuit breaker may activate while a battery is charging. This may occur for either of the following reasons:

„

„

Defective battery—check the battery before replacing the DC breaker

Excessive current draw from a large capacity battery or a totally discharged battery—use an AC battery charger to charge the battery instead of the generator.

2.16

Stopping the Generator

Before stopping

Check with other personnel on the jobsite and let them know that power is being turned off. Make sure that the power shutdown will not create any hazards by turning off devices such as pumps, heaters, or lights that may need to be kept on.

Stopping procedure

To stop the generator:

1. Switch off and disconnect all equipment from the generator.

2. Allow the generator to run at no load for approximately 3 minutes.

3. Turn the engine switch to the STOP position.

2.17

Emergency Shutdown Procedure

Procedure If a breakdown or accident occurs while the machine is operating, follow the procedure below:

1. Stop the engine.

2. Turn off the fuel supply.

3. Disconnect tools from the machine.

4. Allow the machine to cool.

5. Contact the rental yard or machine owner for further instructions.