Serial Port Setup. Bay Technical Associates BayTech DS71-MD4, DS72


Add to my manuals
38 Pages

advertisement

Serial Port Setup. Bay Technical Associates BayTech DS71-MD4, DS72 | Manualzz

DS72 Host Module

22. Select the ‘Gateway Address’ option and type the assigned Gateway address and press

‘Enter’.

23. Press ‘Enter’ until you are asked to ‘Accept Changes’. Type ‘Y’ to accept changes.

24. Press ‘Enter’ until you get the Network Access Menu, (Figure 1).

25. Select ‘Unit reset’ to update the external connections. Once the reset is completed (1 minute) connect the Baytech device to your network using an Ethernet cable.

At this point you have setup enough basic configurations to operate this Baytech unit.

Serial Port Setup

• Connect the 9FRJ45PC-4 adapter to the user’s computer

• Connect the Host Module’s EIA-232 port to the adapter via the RJ08X007 rolled flat ribbon cable.

• Default configuration is 9600 bps, 8 data bits, 1 stop bit and no parity.

NOTE: At any time during the session you need to go to another menu, use the Attention

Character = semi-colon (;). Press the attention character key 5 consecutive times to get back to the main status menu.

NOTE: Depending on the DS-Series model, the menus will vary according to the number of DS74 modules installed in the unit. If this is not an initial set-up and Password has already been enabled, you are prompted to login. After logging in successfully, invoke the main menu by sending the attention character five times (;;;;;).

NOTE: Password feature is case sensitive. (Default is user/password is root/baytech)

Main Menu

The following Menu appears or similar:

Figure 1

Module: 2

Attention Character: ;

Device A ................1

Device B ................2

Device C ................3

Device D ................4

DS-RPC ................5 Status of outlets

Status..........................S Current Setup Configuration

Unit Reset......................RU Resets the DS-Unit, terminates internal,

Logout..........................T

Select option ‘C’ for the configuration menu. Select the DS72 module option and the following menu is displayed:

8

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Key Features

  • Ethernet host module for network connectivity
  • EIA-232 serial connection for compatibility with serial devices
  • External modem connection for remote communication
  • Advanced configuration options for customization
  • Compact design for space-saving installation
  • User-friendly interface for easy setup and management

Related manuals

Frequently Answers and Questions

How do I connect my computer to the DS71-MD4?
You can connect your computer to the DS71-MD4 using the 10/100 Base-T Ethernet port or the EIA-232 serial port.
How do I configure the serial port settings?
You can configure the serial port settings in the Configuration Menu of the DS71-MD4.
How do I set up login credentials?