Figure 3-3. File and Folder Organization after Installation. National Instruments 320727B-01, NI-488.2TM
Add to my manuals
50 Pages
advertisement
Software Installation and Configuration Chapter 3
4.
Click on the Install button to install all of the NI-488.2 software. If you want to install only some of the files, click on the Custom Install button and select the items to install.
After installation of all of the software, the NI-488.2
folder should contain the items shown in Figure 3-3. If you are running System 7.0 or later, the NI-488 Config file is placed in the Control Panels folder, and the NI-488 INIT and NI -DMA/DSP files are placed in the Extensions folder. If you are running System 6 or earlier, the
NI-488 Config , NI-488 INIT , and NI -DMA/DSP files are installed in the
System Folder . NB -Boards , a control panel utility, appears with the files.
Figure 3-3. File and Folder Organization after Installation
Step 2. Run the NI-488 Config Control Panel
The NI-488 Config control panel is a configuration utility that you can use to examine and change the software settings for your GPIB-ENET.
1.
To activate the configuration utility, select Control Panels from the Apple menu and double-click on the NI-488 Config icon.
2.
Click on the Interface Type menu and select Ethernet box products as shown in
Figure 3-4.
3.
To choose a GPIB bus to use with your GPIB-ENET, check one of the bus selection boxes as shown in Figure 3-4. The configuration in Figure 3-4 shows gpib4 , with primary GPIB address 0 and secondary GPIB address disabled, as the connection to the GPIB-ENET at IP address 130.164.1.1.
GPIB-ENET for Macintosh 3-4 © National Instruments Corp.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 Limited Warranty
- 4 Copyright
- 4 Trademarks
- 4 WARNING REGARDING MEDICAL AND CLINICAL USE OF NATIONAL INSTRUMENTS PRODUCTS
- 5 FCC/DOC Radio Frequency Interference Compliance
- 5 Federal Communications Commission
- 5 Canadian Department of Communications
- 5 Instructions to Users
- 10 How to Use This Manual Set
- 11 Organization of This Manual
- 12 Conventions Used in This Manual
- 12 Related Documentation
- 13 Customer Communication
- 14 What You Need to Get Started
- 15 Optional Equipment
- 15 Multiple-Computer Software License
- 15 Software Description
- 16 Optional Programming Tools
- 16 Hardware Description
- 17 The Top Panel LEDs
- 18 The Side Panel Connectors
- 19 The Back Panel Switches
- 19 The Bottom Panel Identification Label
- 20 Configure the Hardware
- 20 Determine Network Addresses
- 21 Configure the DIP Switch
- 22 Select the Operating Mode
- 22 Select the Method for Configuring the IP Address
- 22 Set the Ethernet Port Configuration
- 23 Connect the Hardware
- 23 Step 1. Connect the Cables
- 24 Step 2. Switch on Your GPIB-ENET
- 25 NI-488.2 Software Components
- 26 Install the Software
- 26 Step 1. Install the NI-488.2 Files and Folders
- 28 Step 2. Run the NI-488 Config Control Panel
- 29 Step 3. Restart Your Macintosh
- 30 Configure the Software (Optional)
- 31 Troubleshooting Hardware Problems
- 31 Verify the Software Installation
- 32 Troubleshooting Software Problems
- 33 READY LED Signaling
- 33 Step 1. Count the Long Flashes
- 33 Step 2. Count the Short Flashes
- 34 Step 3. Record Your Status Code Number
- 34 Common Questions
- 37 Introduction to IBIC 488.2
- 37 General Programming Considerations
- 39 IPassign Utility
- 40 Update Utility
- 17 Figure 1-1. GPIB-ENET Top Panel
- 18 Figure 1-2. GPIB-ENET Side Panel
- 19 Figure 1-3. GPIB-ENET Back Panel
- 19 Figure 1-4. GPIB-ENET Identification Label
- 21 Figure 2-1. Default Mode Switch Settings (All Switches OFF)
- 23 Figure 2-2. Default Ethernet Port Configuration Switch Setting for Either Type of GPIB-ENET
- 23 Figure 2-3. AUI Ethernet Port Configuration Switch Setting for Either Type of GPIB-ENET
- 27 Figure 3-1. Settings Dialog Box
- 27 Figure 3-2. Installation Dialog Box
- 28 Figure 3-3. File and Folder Organization after Installation
- 29 Figure 3-4. NI-488 Config Control Panel
- 17 Table 1-1. LED Descriptions
- 21 Table 2-1. Configuration Parameters for the GPIB-ENET Switches
- 34 Table 4-1. Sample READY LED Signals and the Corresponding Status Code Numbers
- 38 Table A-1. Electrical Characteristics
- 38 Table A-2. Environmental Characteristics
- 38 Table A-3. Physical Characteristics