4. Junior User Guidebook sensitivity.
Vertical offset back to 0 shortcut key
Turn the VERTICAL POSITION knob to change the vertical display position of channel and press the position knob to set the vertical display position back to 0 as a shortcut key, this is especially helpful when the trace position is far out of the screen and want it to get back to the screen center immediately.
2. Change the Vertical Setting and Observe the Consequent State Information
Change.
With the information displayed in the status bar at the bottom of the waveform window, you can determine any changes in the channel vertical scale factor. z Turn the vertical “VOLTS/DIV” knob and change the “Vertical Scale Factor
(Voltage Division)”, it can be found that the scale factor of the channel corresponding to the status bar has been changed accordingly. z Press buttons of “CH1 MENU”, “CH2 MENU” and “Math”, the operation menu, symbols, waveforms and scale factor status information of the corresponding channel will be displayed in the screen.
Introduction to the Horizontal System
Shown as Fig.4-10, there are a button and two knobs in the “HORIZONTAL
CONTROLS”. The following practices will gradually direct you to be familiar with the setting of horizontal time base.
Fig. 4-13 Horizontal Control Zone
1. Use the horizontal “SEC/DIV” knob to change the horizontal time base setting and observe the consequent status information change. Rotate the horizontal
“SEC/DIV” knob to change the horizontal time base, and it can be found that the
“Horizontal Time Base” display in the status bar changes accordingly.
2. Use the “HORIZONTAL POSITION” knob to adjust the horizontal position of
17
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 11 Introduction to the Structure of the Oscilloscope
- 11 Front panel
- 12 Left side panel
- 12 Right side panel
- 13 Rear Panel
- 14 Control (key and knob) area
- 15 User interface introduction
- 17 How to implement the General Inspection
- 17 How to implement the Function Inspection
- 18 How to Implement the Probe Compensation
- 19 How to Set the Probe Attenuation Coefficient
- 20 How to Use the Probe Safely
- 21 How to Implement Auto-calibration
- 21 Introduction to the Vertical System
- 22 Introduction to the Horizontal System
- 23 Introduction to the Trigger System
- 26 How to Set the Vertical System
- 30 Implementation of Mathematical Manipulation Function
- 32 Using FFT function
- 36 Application of VERTICAL POSITION and VOLTS/DIV Knobs
- 36 How to Set the Horizontal System
- 39 How to set the Trigger System
- 39 Single trigger
- 43 Alternate trigger
- 47 How to Operate the Function Menu
- 47 How to Implement Sampling Setup
- 49 How to Set the Display System
- 54 How to Save and Recall a Waveform
- 56 How to Record/Playback Waveforms
- 59 How to Implement the Auxiliary System Function Setting
- 64 How to Measure Automatically
- 67 How to measure with cursors
- 72 How to use Autoscale
- 74 How to Use Executive Buttons
- 76 Example 1: Measurement of Simple Signals
- 77 Example 2:Gain of the Amplifier in the Metering Circuit
- 78 Example 3: Capture the Single Signal
- 80 Example 4: Analyze the Details of a Signal
- 82 Example 5: Application of X-Y Function
- 83 Example 6: Video Signal Trigger
- 92 General Technical Specifications
- 93 Appendix A: Enclosure
- 93 Appendix B: Maintenance, Cleaning and Repairing
- 94 Appendix C: Battery Using Guide