CFW-11M Load Cell Center Winder Application


Add to my manuals
71 Pages

advertisement

CFW-11M Load Cell Center Winder Application | Manualzz

Parameters Description

tension setpoint, which is setpoint shown in the parameter P1012. It has the read or write function as configuration adjusted in parameter P1029.

P1029 – Web Tension Setpoint Source Selection

Adjustable

Range:

1 = Setpoint via Analog Input AI1

2 = Setpoint via Analog Input AI2

3 = Setpoint via Analog Input AI3

4 = Setpoint via Analog Input AI4

5 = Setpoint via HMI

6 = Setpoint via Electronic Potentiometer

7 = Setpoint via Communication Networks

Proprieties:

Factory Setting: P1023 = 0: 5

P1023 = 1: 5

P1023 = 2: 5

Access groups via HMI:

01 PARAMETER GROUPS

∟ 50 SoftPLC

.....

Description:

This parameter defines the source of web tension setpoint.

Table 5.6 – Description of the web tension setpoint source

P1029 Description

3

4

1

2

5

6

It defines that the setpoint source will be the value read via analog input AI1 and visualized in parameter P1011.

It defines that the setpoint source will be the value read via analog input AI2 and visualized in parameter P1011.

It defines that the setpoint source will be the value read via analog input AI3 and visualized in parameter P1011.

It defines that the setpoint source will be the value read via analog input AI4 and visualized in parameter P1011.

It defines that the setpoint source will be the value write in parameter P1011 via HMI.

It defines that the setpoint source will be via electronic potentiometer and visualized in parameter P1011.

7 It defines that the setpoint source will be the value write in parameter P1011 via communication networks.

5.15 LINE SPEED

This parameter group allows the user to configure the line speed.

P1015 – Line Speed

Factory Setting: -

Range:

Proprieties:

RW

Access groups via HMI:

01 PARAMETER GROUPS

∟ 50 SoftPLC

.....

Description:

This parameter shows the value of line speed used to control the center winder or unwinder when in torque limit mode or speed mode. It has the read or write function as configuration adjusted in parameter P1030.

Load Cell Center Winder | 53