This parameter defines the value read by analog input AI1, AI2, AI3 or AI4 configured in parameter P1032 for point 2 calibration of the roll diameter line equation corresponding to the diameter value set in parameter P1038.
5.17 TAPER FUNCTION
This parameter group allows the user to adjust the operation conditions of the Taper function.
NOTE!
In order that the Taper function works properly, pay close attention to the roll diameter value, if it is calculated as well as if it is measured.
P1041 – Taper Function Setpoint
Adjustable -100 to +100 %
Range:
Proprieties:
Factory Setting: 0 %
Access groups via HMI:
01 PARAMETER GROUPS
∟ 50 SoftPLC
.....
Description:
This parameter defines the setpoint value for the Taper function. It corresponds to the final value of the control setpoint when the roll diameter is equal or bigger than the final diameter (P1043).
NOTE!
Remember the Taper function concept. Therefore, a setpoint with positive value means decreasing the web tension as the roll diameter increases and negative setpoint means increasing it!
P1042 – Taper Function Initial Diameter
Adjustable 1 to 3000 mm
Range:
Proprieties:
Factory Setting: 150 mm
Access groups via HMI:
01 PARAMETER GROUPS
∟ 50 SoftPLC
.....
Description:
This parameter defines at what diameter the Taper function for the web tension setpoint will be initiated.
P1043 – Taper Function Final Diameter
Adjustable 1 to 3000 mm
Range:
Proprieties:
Access groups via HMI:
01 PARAMETER GROUPS
∟ 50 SoftPLC
.....
Factory Setting: 500 mm
Description:
This parameter defines the roll diameter to which the Taper function setpoint (P1041) applies; from this diameter onwards, the Taper function setpoint value for the control remains constant.
5.18 STALL MODE
This parameter group allows the user to adjust the parameters for Stall mode operation for the load cell center winder.
Load Cell Center Winder | 58
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: [email protected]
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 6 ABOUT THE MANUAL
- 6 ABBREVIATIONS AND DEFINITIONS
- 6 NUMERICAL REPRESENTATION
- 7 1. INTRODUCTION TO CENTER WINDERS
- 7 1.1 WINDING
- 7 1.2 CENTER WINDER CONCEPT
- 8 1.3 TERMS USED IN CENTER WINDERS
- 11 1.4 GENERAL CHARACTERISTICS OF THE CENTER WINDER APPLICATIVE
- 12 2 LOAD CELL CENTER WINDER
- 12 2.1 TORQUE LIMIT MODE
- 15 2.2 TORQUE MODE
- 18 2.3 SPEED MODE
- 21 3 WLP APPLICATIVE CONFIGURATION
- 33 4 WLP APPLICATIVE DOWNLOAD
- 34 5 PARAMETERS DESCRIPTION
- 34 5.1 CENTER WINDER CHARACTERISTICS
- 34 5.2 ORIGIN OF THE COMMANDS
- 35 5.3 RAMPS
- 35 5.4 SPEED LIMITS
- 36 5.5 DYNAMIC BRAKING
- 36 5.6 WINDER CONTROL CONFIGURATION
- 37 5.7 PID CONTROLLER
- 39 5.8 MOTOR TORQUE CURRENT REFERENCE
- 40 5.9 CONTROL WORD
- 41 5.10 DIGITAL INPUTS
- 45 5.11 DIGITAL OUTPUTS
- 46 5.12 ANALOG INPUTS
- 52 5.13 WEB TENSION VIA LOAD CELL
- 52 5.14 WEB TENSION SETPOINT
- 53 5.15 LINE SPEED
- 54 5.16 ROLL DIAMETER
- 58 5.17 TAPER FUNCTION
- 58 5.18 STALL MODE
- 59 5.19 WEB PRESENCE DETECTION IN WINDER
- 60 5.20 READING PARAMETERS
- 62 6 FAULT AND ALARM MESSAGES
- 63 7 MONITORING DIALOGS
- 67 8 TREND VARIABLES DIALOGS
- 69 9 PARAMETER VALUE DIALOGS
- 70 10 GENERAL NOTES