Initialization (Reset)/Functional Restriction Setting (FUNCTION)
You can return the settings to their factory-preset values and restrict operations.
1. Hold
SIZE
down until “F” appears in the upper left corner of the screen.
2. While “F” appears, press , , , in that order.
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C/LAN
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
OFF
UNLOCKED
ON 1
ON
LED
POWER BUTTON
EXTERNAL CONTROLLER INPUT
OFF
MONITOR
OK…[ENTER] END…[RETURN]
3. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press
ENTER
, select the resetting method, and then press
ENTER
.
ALL RESET1 ....Resets all the settings to the factory default settings.
ALL RESET2 ....Returns all settings to the factory default settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT,
BAUD RATE, NETWORK, MAIL,
SERVICE & SUPPORT, and SNMP (See page 34, and pages 57 to 60.)
* The wireless controller settings will not be reset.
ADJUSTMENT LOCK
You can disable operations on the monitor and the remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not even power on/off).
When POWER SAVE MODE is set to ON, ON 2 cannot be set.
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with
ADJUSTMENT LOCK.
REMOTE CONTROL ..... Prohibits remote control operation
MONITOR BUTTONS ... Prohibits monitor button operation
BOTH ............................. Prohibits remote control and monitor button operation
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN
(see pages 42 and 53).
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION screen cannot be hidden.
ON 1 .............. Shows all menus, modes and messages.
ON 2 .............. Hides messages automatically displayed by the display. Shows messages during operation.
OFF ............... Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
TEMPERATURE ALERT
Selects the notification method for an abnormal temperature.
OFF .............. Do not notify about an abnormal temperature.
OSD & LED .. When an abnormal temperature is detected, the power LED flashes in red and green alternately and the screen displays a message: TEMPERATURE.
LED............... When an abnormal temperature is detected, the power LED flashes in red and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF .............. Do not notify about the error.
OSD & LED .. When a hardware error is detected, the power LED flashes in red and the screen displays a message: STATUS [xxxx].
LED............... When a hardware error is detected, the power LED flashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears, change the setting accordingly.
EXTERNAL CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears, change the setting accordingly.
4. Press
RETURN
to return to the normal screen.
TIPS
• When both abnormal temperature and hardware error are detected, the hardware error notification overrides.
• If TEMPERATURE ALERT or STATUS ALERT is set to
OSD&LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
• If TEMPERATURE ALERT or STATUS ALERT is set to LED or OSD & LED, the LED lights even if the LED function is set to OFF.
41
E
advertisement
Key Features
- Touchscreen 177.8 cm (70") LCD
- 1920 x 1080 pixels
- 6 ms 3000:1
Related manuals
advertisement
Table of contents
- 3 IMPORTANT INFORMATION
- 4 DEAR SHARP CUSTOMER
- 4 SAFETY PRECAUTIONS
- 6 TIPS AND SAFETY INSTRUCTIONS
- 7 MOUNTING PRECAUTIONS
- 9 Supplied Components
- 9 System Requirements
- 10 Part Names
- 12 Connecting Peripheral Equipment
- 14 Connecting the Power Cord
- 14 Binding Cables
- 15 Preparing the Remote Control Unit
- 15 Installing the batteries
- 15 Remote control operation range
- 16 Removing the Handles
- 16 Mounting a web camera
- 17 Connecting the wireless adapter
- 17 Connecting the wireless token
- 18 Turning Power On/Off
- 18 Turning on the main power
- 18 Turning power on
- 19 Turning power off
- 20 Touch Panel / Touch Pen Preparations
- 20 Connecting the touch pen adapter
- 20 Touch Pen Preparations
- 20 Computer preparations
- 20 Calibration
- 21 Touch pen actions
- 21 Adding touch pens (pairing)
- 22 Touch action
- 22 Touch action
- 24 Other functions
- 24 Cautionary points
- 24 Eraser
- 25 Basic Operation
- 25 Using the touch menu
- 26 Using the remote control unit
- 29 Menu Items
- 29 Displaying the menu screen
- 30 Menu item details
- 40 Adjustments for PC screen display
- 41 Initialization (Reset)/Functional Restriction Setting (FUNCTION)
- 42 Controlling the Monitor with a PC (RS-232C)
- 42 PC connection
- 42 Communication conditions
- 42 Communication procedure
- 44 Setting of the GAMMA user data
- 45 RS-232C command table
- 53 Controlling the Monitor with a computer (LAN)
- 53 Settings to connect to a LAN
- 55 Controlling with a computer
- 61 [Advanced operation] Command-based control
- 62 Troubleshooting
- 64 Specifications
- 69 Mounting Precautions (For SHARP dealers and service engineers)