Psion Teklogix PowerScan D8330 User manual
광고
광고
Psion Teklogix
PowerScan ® D8330/M8300
User Manual
April 22, 2008 Part No. 8100166.A
ISO 9001 Certified Quality
Management System
Copyright © 2008 Psion Teklogix Inc. Mississauga, Ontario
All rights reserved. This document is an unpublished work and the information it contains is the property of Psion Teklogix, or its licensors, is issued in strict confidence, and may not be reproduced or copied, in whole or in part, except with written consent from Psion Teklogix. Furthermore, this document is not to be used as a basis for design, manufacture, or subcontract, or in any manner detrimental to the interests of Psion or its licensors. Psion
®
, Teklogix
®
, and all Psion Teklogix products and brand names are trademarks of Psion Teklogix and its affiliates.
Windows® and the Windows Logo are trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
All trademarks are the property of their respective holders.
Return-To-Factory Warranty
Psion Teklogix Inc. provides a return to factory warranty on this product for a period of twelve (12) months in accordance with the statement of Warranty and Product Support provided at: www.psionteklogix.com/warranty
The warranty on Psion Teklogix manufactured equipment does not extend to any product that has been tampered with, altered, or repaired by any person other than an employee of an authorized Psion Teklogix service organization.
See Psion Teklogix terms and conditions of sale for full details.
Important: Psion Teklogix warranties take effect on the date of shipment.
Support Services And Worldwide Offices
Psion Teklogix provides a complete range of product support services to its customers worldwide. These services include technical support and product repairs.
Technical Support
For technical support in North America:
Call Toll free: +1 800 387 8898 Option 3, or
Direct Dial: +1 905 813 9900 Ext. 1999 Option 3
For technical support in EMEA (Europe, Middle East and Africa), please contact the local office listed in the website below: http://www.psionteklogix.com/EMEASupport
For technical support in Asia, please contact the local office listed in the website below: http://www.psionteklogix.com
Technical Support for Mobile Computing Products is provided via email through the Psion Teklogix customer and partner extranets. To reach the website, go to www.psionteklogix.com
, and click on the appropriate Teknet link on the home page. Then click on the “Login” button or the “Register” button, depending on whether you have previously registered for Teknet. Once you have logged in, search for the “Support Request Form”.
Product Repairs
For repair service in North America:
Call Toll free: +1 800 387 8898 Option 2, or
Direct Dial: +1 905 813 9900 Ext. 1999 Option 2
For repair service in EMEA (Europe, Middle East and Africa), please contact the local office listed in the website below: http://www.psionteklogix.com/EMEASupport
For repair service in Asia, please contact the local office listed in the website below: http://www.psionteklogix.com
Worldwide Offices
C OMPANY H EADQUARTERS
Psion Teklogix Inc.
2100 Meadowvale Blvd.
Mississauga, Ontario
Canada L5N 7J9
Tel: +1 905 813 9900
Fax: +1 905 812 6300
E-mail: [email protected]
C ANADIAN S ERVICE C ENTRE
Psion Teklogix Inc.
7170 West Credit Ave., Unit #1
Mississauga, Ontario
Canada L5N 7J9
Tel: +1 800 387 8898 Option 2 - or -
Direct: + 1 905 813 9900 Ext. 1999, Option 2
Fax: + 1 905 812 6304
E-mail: www.psionteklogix.com
N ORTH A MERICAN H EADQUARTERS A ND U.S. S ERVICE C ENTRE
Psion Teklogix Corp.
3000 Kustom Drive
Hebron, Kentucky
USA 41048
Tel: +1 859 371 6006
Fax: +1 859 371 6422
E-mail: [email protected]
I NTERNATIONAL S UBSIDIARIES ( see also www.psionteklogix.com/Subsidiaries )
Psion Teklogix S.A.
La Duranne, 135 Rue Rene Descartes
BP 421000
13591 Aix-En-Provence
Cedex 3; France
Tel:
Fax:
+33 4 42 90 88 09
+33 4 42 90 88 88
E-mail: [email protected]
Waste Electrical and Electronic Equipment (WEEE) Directive
2002/96/EC
This Product, and its accessories, comply with the requirements of the Waste
Electrical and Electronic Equipment (WEEE) Directive 2002/96/EC. If your end-of-life Psion Teklogix product or accessory carries a label as shown here, please contact your local country representative for details on how to arrange recycling. For a list of international subsidiaries, please go to: www.psionteklogix.com/EnvironmentalCompliance
Restriction On Hazardous Substances (RoHS) Directive
2002/95/EC
What is RoHS?
The European Union has mandated that high environmental standards be met in the design and manufacture of electronic and electrical products sold in
Europe, to reduce hazardous substances from entering the environment. The
“Restriction on Hazardous Substances Directive (RoHS)” prescribes the maximum trace levels of lead, cadmium, mercury, hexavalent chromium, and flame retardants PBB and PBDE that may be contained in a product.
Only products meeting these high environmental standards may be “placed on the market” in EU member states after July 1, 2006.
RoHS Logo
Although there is no legal requirement to mark RoHS-compliant products,
Psion Teklogix Inc. indicates its compliance with the directive as follows:
The RoHS logo located either on the back of the product or underneath the battery in the battery compartment (or on a related accessory such as the charger or docking station) signifies that the product is RoHS-compliant as per the EU directive. Other than as noted below, a Psion Teklogix product that does not have an accompanying RoHS logo signifies that it was placed on the EU market prior to July 1, 2006, and is thereby exempt from the directive.
Note: Not all accessories or peripherals will have a RoHS logo due to physical space limitations or as a result of their exempt status.
Disclaimer
Every effort has been made to make this material complete, accurate, and upto-date. In addition, changes are periodically added to the information herein; these changes will be incorporated into new editions of the publication.
Psion Teklogix Inc. reserves the right to make improvements and/or changes in the product(s) and/or the program(s) described in this document without notice, and shall not be responsible for any damages, including but not limited to consequential damages, caused by reliance on the material presented, including but not limited to typographical errors.
COMPLIANCE
This device must be opened by qualified personnel only.
The batteries must be removed before opening the device.
FCC COMPLIANCE
Modifications or changes to this equipment without the express written approval of Psion
Teklogix could void the authority to use the equipment.
This device complies with PART 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference which may cause undesired operation.
FCC ID U4F0015.
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Emissions Information For Canada
This Class B digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations. Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.
RADIO COMPLIANCE
Contact the competent authority responsible for the management of radio frequency devices of your country to verify any possible restrictions or licenses required.
Refer to the web site http://europa.eu.int/comm/enterprise/rtte/spectr.htm
for further information.
When used in a residential, commercial or light industrial environment the product and its approved UK and European peripherals fulfil all requirements for CE marking.
This equipment complies with the essential requirements of EU Directive 1999/5/EC
(Declaration available: www.psionteklogix.com).
Cet équipement est conforme aux principales caractéristiques définies dans la Directive européenne RTTE 1999/5/CE. (Déclaration disponible sur le site: www.psionteklogix.com).
Die Geräte erfüllen die grundlegenden Anforderungen der RTTE-Richtlinie (1999/5/EG). (Den
Wortlaut der Richtlinie finden Sie unter: www.psionteklogix.com).
Questa apparecchiatura è conforme ai requisiti essenziali della Direttiva Europea R&TTE
1999/5/CE. (Dichiarazione disponibile sul sito: www.psionteklogix.com).
Este equipo cumple los requisitos principales de la Directiva 1995/5/CE de la UE, “Equipos de
Terminales de Radio y Telecomunicaciones”. (Declaración disponible en: www.psionteklogix.com).
Este equipamento cumpre os requisitos essenciais da Directiva 1999/5/CE do Parlamento
Europeu e do Conselho (Directiva RTT). (Declaração disponível no endereço: www.psionteklogix.com).
Ο εξοπλισμός αυτός πληροί τις βασικές απαιτήσεις της κοινοτικής οδηγίας EU R&TTE
1999/5/EΚ. (Η δήλωση συμμόρφωσης διατίθεται στη διεύθυνση: www.psionteklogix.com)
Deze apparatuur voldoet aan de noodzakelijke vereisten van EU-richtlijn betreffende radioapparatuur en telecommunicatie-eindappa-ratuur 199/5/EG. (verklaring beschikbaar: www.psionteklogix.com).
Dette udstyr opfylder de Væsentlige krav i EU's direktiv 1999/5/EC om Radio- og teleterminaludstyr. (Erklæring findes på: www.psionteklogix.com).
Dette utstyret er i overensstemmelse med hovedkravene i R&TTE-direktivet (1999/5/EC) fra EU.
(Erklæring finnes på: www.psionteklogix.com).
Utrustningen uppfyller kraven för EU-direktivet 1999/5/EC om ansluten teleutrustning och
ömsesidigt erkännande av utrustningens överensstämmelse (R&TTE). (Förklaringen finns att läsa på: www.psionteklogix.com).
Tämä laite vastaa EU:n radio- ja telepäätelaitedirektiivin (EU R&TTE Directive 1999/5/EC) vaatimuksia. (Julkilausuma nähtävillä osoitteessa: www.psionteklogix.com).
Psion Teklogix tímto prohlašuje, že PowerScan M8300 je ve shodì se základními požadavky a dalšími pøíslušnými ustanoveními smìrnice 1995/5/ES (NV è. 426/2000 Sb.) a Prohlášení o shodì je k dispozici na www.psionteklogix.com.
Toto za řízení lze provozovat v České republice na základě generální licence č. GL-12/R/2000.
Psion Teklogix týmto vyhlasuje, že PowerScan M8300 spĺň a základné požiadavky a všetky príslušné ustanovenia Smernice 1995/5/ES (NV č. 443/2001 Z.z.) a Vyhlásenie o zhode je k dispozícii na www.psionteklogix.com.
Toto zariadenie je mo žné prevádzkovat’ v Slovenskej republike na základe Všeobecného povolenia č. VPR-01/2001.
LASER SAFETY COMPLIANCE
The laser scanner conforms to the applicable requirements of both CDRH 21 CFR 1040 and
EN60825-1 at the date of manufacture.
The laser light is visible to the human eye and is emitted from the output window c.
Laser warning and classification label d.
CAUTION
Use of controls or adjustments or performance of procedures other than those specified herein may result in exposure to hazardous visible laser light.
The laser scanner utilizes a low-power laser diode. Although staring directly at the laser beam momentarily causes no known biological damage, avoid staring at the beam as one would with any very strong light source, such as the sun. Avoid that the laser beam hits the eye of an observer, even through reflective surfaces such as mirrors, etc.
The following information is shown on the laser scanner device class label:
DO NOT STARE INTO BEAM
LASER RADIATION -
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT (IEC)
CLASS II LASER PRODUCT (CDRH)
MAX. OUTPUT RADIATION 1.4 mW
EMITTED WAVELENGTH 630~680 nm
EN60825-1: 2001
CAUTION - CLASS 2 LASER
LIGHT WHEN OPEN
AVOID EXPOSURE – LASER LIGHT
IS EMITTED FROM THIS APERTURE
This product complies with
21 CFR Subchapter J
ITALIANO DEUTSCH
Classe 2: LUCE LASER Klasse 2: LASERSTRAHLUNG
NON FISSARE IL RAGGIO
APPARECCHIO LASER DI CLASSE 2
NICHT IN DEN STRAHL
PRODUKT DER LASERKLASSE 2
FRANÇAIS ESPAÑOL
Classe 2: RAYON LASER
EVITER DE REGARDER LE RAYON
Clase 2: RAYO LÁSER
NO MIRAR FIJO EL RAYO
APPAREIL LASER DE CLASSE 2 APARATO LÁSER DE CLASE 2
LED CLASS
Class 1 LED product.
This product conforms to EN60825-1:2001.
IC (INDUSTRY CANADA)
Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
Psion Teklogix Inc.
2100 Meadowvale Boulevard,
Mississauga, Ontario, Canada L5N 7J9 http:\\www.psionteklogix.com
08 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el
PowerScan Mxxx; Cordless Bar code Reader e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente:
1999/5/EEC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con la siguientes normas:
ETSI EN 301 489-3 V 1.4.1, A UGUST 2002 : E LECTROMAGNETIC COMPATIBILITY AND R ADIO SPECTRUM M ATTERS
(ERM); E
LECTROMAGNETIC COMPATIBILITY
(EMC)
STANDARD FOR
RADIO EQUIPMENT AND SERVICES ; P ART 3: S PECIFIC CONDITIONS FOR
S HORT -R ANGE D EVICES (SRD) OPERATING ON FREQUENCIES BETWEEN
9
K
H
Z AND
40GH
Z
ETSI EN 300 220-3 V 1.1.1, S EPTEMBER 2000 : E LECTROMAGNETIC COMPATIBILITY AND R ADIO SPECTRUM M ATTERS
(ERM); S
HORT
R
ANGE
D
EVICES
(SRD); R
ADIO EQUIPMENT TO BE USED
EN 60950-1, D
ECEMBER
2001 :
IN THE 25MH Z TO 1000MH Z FREQUENCY RANGE WITH POWER LEVELS
RANGING UP TO 500 M W; P ART 3: H ARMONIZED EN COVERING
ESSENTIAL REQUIREMENTS UNDER ARTICLE
3.2
OF THE
R&TTE
D IRECTIVE
INFORMATION TECHNOLOGY EQUIPMENT S AFETY -
P
ART
1 : G
ENERAL
R
EQUIREMENTS
April 16, 2008
NOTES
CONTENTS
D8330 Interface Cable Connections ........................................ 2
BC-80X0 Interface Cable Connections ......................................................... 4
PEN Emulation Connection...........................................................................7
BC-8060 Network Connectors ...................................................................... 8
PowerScan ® M8300 Battery Maintenance .................................................. 11
Replacing PowerScan ® M8300 Batteries .................................................... 11
Mounting The BC-80X0 / C-8000 Cradle .................................................... 12
3 POWERSCAN ® M8300 SYSTEM AND NETWORK LAYOUTS.................. 18
Stand-Alone Layout with Multiple Readers ................................................. 18
Multidrop STAR-System™ Network Layouts .............................................. 21
Master BC-8060 Network Troubleshooting ................................................. 23
Reading Configuration Bar Codes .............................................................. 24
Using the Original Manufacturer’s Datalogic Aladdin™ .............................. 24
Sending Configuration Strings from Host.................................................... 25
D8330 Setup .......................................................................... 27
M8300/BC-80X0 Point-to-Point Setup ................................... 27
M8300/BC-80X0 Stand-Alone Setup ..................................... 28
Using Multiple M-Series Readers with Same Cradle .................................. 30
M8300/STAR-Modem™ in Stand-Alone Mode ...................... 31
iii
PowerScan ® M8300/STAR-System™ Setup .............................................. 32
BC-8060 STAR-System™ Network Setup .................................................. 34
Conversion to Code 39 and Code 128...................................................... 143
Slave Address Range First/Last................................................................ 145
Network Warning Message ....................................................................... 145
Reception Warning Message .................................................................... 146
Master Header/Terminator Selection ........................................................ 146
Header/Terminator Selection .................................................................... 146
5.4.2
Define Special Key Sequence................................................................... 148
Radio Parameters (M8300 Series Only) ................................................... 159
iv
Beeper Control for Radio Response ......................................................... 161
®
M8300 only) .......................................................... 163
Display Parameters (Some M8300 Models only) ...................................... 164
Configuration Editing Commands ............................................................. 165
Custom Default Configuration ................................................................... 166
Configuration Copying Commands ........................................................... 167
®
D8330 Series.............................................................. 167
M8300 Series ............................................................. 168
Default Parameters for POS Terminals..................................................... 170
6 MESSAGE FORMATTING ....................................................................... 172
Messages from Host to Reader ................................................................ 172
6.1.4
LED and Beeper Control........................................................................... 174
Messages from SCANNER Command Keys............................................. 175
7 TECHNICAL FEATURES ......................................................................... 177
D8330 .................................................................................. 177
System and Radio Features...................................................................... 180
7.5
Status Indicators ....................................................................................... 180
v
GENERAL VIEW
POWERSCAN
®
D8330/M8300 READERS
LEDs
POWERSCAN ® D8330
Cable Connector
POWERSCAN ® M8300
Battery Cover
Laser Output
Window
Trigger
Figure A – PowerScan ® D8330/M8300 Series Readers
LEDs
Keypad
Display vi
Laser Output Window
Figure B – PowerScan ® M8300 Series Readers with Display
BC-80X0 / C-8000 CRADLES
Scan Finder
Button
LEDs
Figure C – BC-8000
The label on the cradle contains LED indicators and a scan finder button. When the button is pressed, the cradle transmits a “broadcast” message. All properly configured scanners (Radio RX Timeout set to keep the radio “awake”) linked to that base (through a bind or a join sequence) and within radio range coverage will emit a beep sequence once every 2 seconds for 30 seconds. A scanner is considered to be linked when the last transmission ends properly.
The scan finder works only in stand-alone layout (point to point or multiple readers).
Figure D – C-8000
LEDs vii
INTRODUCTION
1 INTRODUCTION
Psion Teklogix renews its range of industrial laser scanners introducing the
PowerScan
®
family: PowerScan
®
D8330 and PowerScan
®
M8300. Robustness and ergonomics remain unsurpassed: clearly audible beeper and bright "good read" LEDs for areas where noise levels are normally high; the aim mode, which helps point to the right code, has now been extended to the whole PowerScan parts are completely suspended on shock absorbers and a careful choice of the body materials, such as the co-moulded rubber, protect the PowerScan due to "falls".
®
family. Optical
®
from damage
New enhanced architecture, based on an M16 high-speed microprocessor, enables exceptional performance for promptness and reading speed of standard codes as well as the ability to read poorly printed and damaged codes. Patented Puzzle Solver
Technology™ adds further strength to the PowerScan ® powerful engine.
In all applications where mobility is a value, the new PowerScan
®
M8300 represents the key to increase productivity and flexibility in the working area.
PowerScan
®
M8300 communicates through a low power, license-free radio in the
433 MHz band (910 MHz for USA version) and allows bi-directional communication between the base station and the host. PowerScan
®
M8300 also includes a display and a 3 push-button keypad. Thanks to these features, the operator can receive information from the host, interact with the central system and visualize the code read. The cordless system offers scalable solutions to solve simple applications and complex projects:
• Point to point: each reader is associated with its own base station;
• Multipoint: up to 32 readers transmit data to one base station;
• Network: to cover a wide area, connecting up to 16 bases and 512 readers simultaneously working in automatic roaming.
PowerScan
®
M8300 is 100% compatible with STAR-System™, the new Psion
Teklogix RF narrow band solution for mobile applications that provides the widest family of narrow band devices on the market.
Your PowerScan
®
reader is supplied with its own Quick Reference Guide, which provides connection, diagrams, reading diagrams, basic application parameter settings, default values, and specific technical features. You can use either the Quick
Reference Guide or this Manual for initial configuration in order to set the default values and select the interface for your application. This manual provides all the necessary information for complete mechanical installation and system software configuration.
1
POWERSCAN ® D8330/M8300
2 INSTALLATION
CAUTION
Connections should always be made with power OFF!
2.1 POWERSCAN ® D8330 INTERFACE CABLE CONNECTIONS
The PowerScan
®
D8330 reader incorporates a multi-standard interface, which can be connected to a Host by plugging the correct interface cable into the connector and closing the cable cover.
A. Rubber gasket
B. Plastic boot
C. Cable spacer
D. Cover
E. Strain relief
2
INSTALLATION
Follow the given procedure for correct cable insertion:
3
Align
2
1 5
6
Notch
4
7
Arrow
Tab c Slip the cover over the cable. d Push the plastic boot into the rubber gasket. Take care that the tab on the plastic boot is aligned with the notch in the rubber gasket. e Push the plastic boot and gasket into the handle. Ensure that the “Front” marking on the plastic boot is facing out, with the arrow pointing towards the front of the scanner. f Insert the cable into the socket of the plastic boot. g Insert the cable spacer into the cable wire and slide it towards the handle. h Push the cover along the cable towards the reader, and hook it over the yellow
“tooth”. i Insert the strain relief into the cover and tighten the screw to fix the whole assembly to the reader handle.
CAUTION
Connections should always be made with power OFF!
3
POWERSCAN ® D8330/M8300
2.2 BC-80X0 INTERFACE CABLE CONNECTIONS
Power
Interface Cable
BC-80X0 Connectors
The BC-80X0 incorporates a multi-standard interface, which can be connected to a
Host by simply plugging the correct interface cable into the Host connector, placed on the base of the cradle. In addition the cradle must be connected to an external power supply.
Disconnecting the BC-80X0 Cable
To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle.
Push down on the clip while unplugging the cable.
4
2.3 RS-232 CONNECTION
2.4 USB
(if required)
INSTALLATION
5
POWERSCAN ® D8330/M8300
2.5 IBM USB POS
(if required)
6
2.6 WEDGE CONNECTION
2.7 PEN EMULATION CONNECTION
INSTALLATION
7
POWERSCAN ® D8330/M8300
2.8 NETWORK CONNECTIONS
2.8.1 BC-8060 Network Connectors
The multidrop network is a bus system which is propagated from one BC-8060 cradle to another using individual cables. This is possible thanks to the RS-485 connector on the front panel of the cradle.
Power Supply
RS-485
(BC-8060only)
MULTI-INTERFACE
RS-232, USB, Wedge,
PEN Emulation
All cradles are connected together within the bus system through the Psion Teklogix
RS-485 splitter cable (CAB-428, part number 90A051950), which must be inserted in the RS-485 cradle connector.
Obviously cable length is to be kept to a minimum as with all bus systems.
8
INSTALLATION
2.8.2 Network Cabling
The Multidrop line is made using RJ45 connectors and a cable having the following specifications:
• twisted pair AWG 24 wires
• maximum network cable length 1200 meters
Pin Function
+
-
3 N.C.
–
–
6 N.C.
+
+
Data only
Pin 1
Cables
Data and
Power
Supply
RJ45 RJ45 RJ45
Twisted Pair - Power supply
VDC+
RJ45
VDC- 8 8
5 5 VDC-
RS-485- 5
RS-485-
5
2
RS-485+
2
2
RS-485+
2
1 1
1 1
Twisted Pair – RS-485 bus
Twisted Pair – RS-485 bus
When wiring the multidrop cables, note the following:
Pin 8 (or 7) can be connected only if the power has to be propagated from a cradle to a
STARGATE™ base station or STAR-Box™ converter via the cable.
Pins 5 (or 4) should always be connected as reference ground.
To avoid excessive voltage drop, it is recommended not to propagate power between
BC-8060 cradles when used as battery chargers but to supply each cradle individually. The total number of devices, which can be connected to a single power supply, depends on the power supply voltage, the wire length and resistance and therefore the voltage drop. Do NOT connect VDC+ between network devices that are individually powered.
9
POWERSCAN ® D8330/M8300
2.8.3 Network Termination
The first and last cradles of the chain (the two ends of the bus) must be properly terminated. The cradle has an internal terminator that can be selected via jumper.
For this selection you must open the device.
No Termination Static Dynamic
Terminator for Multidrop Network
Static termination works for all network configurations. However, the network is always under load even when no data transmission takes place.
Dynamic termination can be used for baud rates at or above 38400 and provides less load on the network when idle.
10
INSTALLATION
2.9 POWERSCAN ® M8300 BATTERY MAINTENANCE
2.9.1 Battery Charging
Once the system is connected and powered, you can place the PowerScan
®
M8300 into the cradle to charge the battery.
When the reader is correctly inserted in the cradle, the "Reader" red LED on the cradle goes on to indicate that the battery is charging. The "Reader" green LED on the cradle goes on when the battery is completely charged.
2.9.2 Replacing PowerScan ® M8300 Batteries
To change the batteries in your PowerScan
®
M8300 scanner, press the black button or unscrew the fixing screw on the handle cover and extract the battery pack from the reader handle.
1
2
NOTE
When the batteries are extracted from the scanner, the timer maintains the current hour and date for about 1 minute.
Replace the old battery pack with a new one by inserting it within the reader handle and pushing it until it clicks.
WARNING
Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
11
POWERSCAN ® D8330/M8300
2.10 MOUNTING THE BC-80X0 / C-8000 CRADLE
The cradle package contains the following items:
BC-80X0 / C-8000 Cradle
BC-80X0 Cradle Quick Reference Guide / C-8000 Cradle Quick Reference Guide
BC-8000 Antenna 2 wall-mounting lock hinges
2 adhesive strips
1 horizontal base
4 rubber feet
1 inclined base
The cradle (either BC-80X0 or C-8000) can be mounted for portable or fixed desktop usage, or it can be fixed to a wall. The horizontal base allows portable and fixed desktop usage, while the inclined base provides desktop and wall mounting guaranteeing a comfortable handling of the PowerScan
®
M8300 reader.
BC-80X0/C-8000 Cradle mounted on the Horizontal Base
12
BC-80X0/C-8000 Cradle mounted on the Inclined Base
INSTALLATION
2.10.1 Desktop Mounting
For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions, or on the inclined base for a more ergonomic taking out and insertion of the reader onto the cradle.
Horizontal base
Mounting
Tabs (4)
Rubber Foot
Seat (4)
Mounting
Holes (2)
Adhesive Strip
Seat (2)
Cable
Channels
Mounting
Tabs (4)
Top View Bottom View
Inclined base
Adhesive Strip
Seat (2)
Mounting
Holes (4)
Top View
Rubber Foot
Seat (4)
Bottom View
Cable
Channels
13
POWERSCAN ® D8330/M8300
Portable Desktop Use
1.
Correctly position the BC-80X0/C-8000 onto the base by sliding it along the mounting tabs until aligned.
1 1
2
2
2.
Carefully clean the rubber foot seats of the base to remove any impurities that could reduce adhesion.
3.
Remove the protective plastic from the rubber feet and stick them onto the bottom surface of the base.
4.
If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
Fixed Desktop Use
For fixed desktop installation, use the adhesive strips or fixing screws (not provided) according to your needs.
For mounting with adhesive strips:
1.
Position the cradle onto the base by sliding it along the mounting tabs until aligned.
2.
Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce adhesion.
3.
Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.
14
INSTALLATION
4.
Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels, as shown in the figures below:
Horizontal Base Inclined Base
5.
Remove the plastic from the other side of the strips and affix the base to the table.
6.
If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
For mounting with screws:
1.
Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels, as shown in the figures above.
2.
Position the base on the table and affix it by means of the screws (not provided).
3.
Position the cradle on the base by sliding it along the mounting tabs until aligned.
4.
If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
15
POWERSCAN ® D8330/M8300
2.10.2 Wall Mounting
1.
Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradle.
2.
Position the cables to be connected to the BC-80X0/C-8000 cradle along the dedicated channels (see figures on page 15).
16
INSTALLATION
If using the adhesive strips: If using the mounting screws: a. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce adhesion.
3.
Using the mounting holes on the base as a pattern, mark the wall where you desire to mount the BC-
80X0/C-8000. b. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.
4.
Drill the appropriate size holes and insert the threaded dowels (not provided) into the holes. c. Remove the plastic from the other side of the strips and affix the base to the wall as indicated in the figure below.
5.
Position the base on the wall as indicated in the figure below and affix it by means of the screws (not provided).
Inclined Base Wall-mounting
6.
Attach the cradle on the base by sliding it along the mounting tabs until aligned.
7.
If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
17
POWERSCAN ® D8330/M8300
3 POWERSCAN
®
LAYOUTS
M8300 SYSTEM AND NETWORK
There are two basic system layouts that can be employed: Stand-alone systems
(including Point-to-Point layouts) and Multidrop STAR-System™ Networks.
3.1 STAND-ALONE LAYOUTS
3.1.1 Point-to-Point Reader Layout
PowerScan
®
M8300
BIND
Host
BC-80X0
3.1.2 Stand-Alone Layout with Multiple Readers
PowerScan
®
M8300
JOIN
BIND
Host
BC-80X0
In stand-alone systems, each cradle is connected to a single Host.
18
POWERSCAN ® M8300 SYSTEM AND NETWORK LAYOUTS
3.1.3 Multiple Stand-Alone Layouts
Many stand-alone connections can operate in the same physical area without interference, provided all readers and cradles in the system have different addresses.
Host
PowerScan ® M8300
JOIN
BC-80X0
BIND
Host
PowerScan ®
M8300
BIND
JOIN
BC-80X0
PowerScan ® M8300
BIND
Host
BC-80X0
Multiple Stand-alone Systems in the Same Area
Since the cradles can communicate to multiple PowerScan ® M8300 readers, you might find it useful to employ one or more C-8000 battery chargers in addition to the
BC-80X0 cradle, so that the battery re-charging operation can be performed for several scanners at the same time.
19
POWERSCAN ® D8330/M8300
3.1.4 C-BOX Layout
PowerScan ® M8300
JOIN
Scanner
BIND
BC-80X0
C-Box
System cables to Host
In this layout the BC-80X0 cradle is connected by a dedicated cable using the RS-232 interface to a C-BOX connection box as part of a fixed scanner network. This allows the flexibility of a hand-held reading station integrated into a variety of fixed scanning applications so that all readers (both fixed and hand-held), in the system provide communications to the Host.
The various C-BOX models provide many interface types for the Host system such as
RS-232, RS-485, Profibus.
20
POWERSCAN ® M8300 SYSTEM AND NETWORK LAYOUTS
3.2 MULTIDROP STAR-SYSTEM™ NETWORK LAYOUTS
Even though many stand-alone systems can operate in the same physical area without interfering with each other, it may be desirable to bridge data from multiple base stations in a network to a single Host. PowerScan
®
M8300 readers are compatible with
STAR-System™ networks. These networks provide seamless active roaming for any
RF reading device in the system.
3.2.1 Host Master Layout
C
Internal
Termination
D
RS-485 + VDC
RS-485 Only
C
Internal
Termination
A
CAB-428 Splitter
B
RS-232
RS-485 + VDC
A. Host Master with STAR-Link™
B. STAR-Box™
C. BC-8060
D. STARGATE™ base stations
Example Multidrop STAR-System™ Network with Host as Master
In this layout the Host acts as the Master using STAR-Link™ software. The Host is connected in RS-232 to a STAR-Box™ converter, which is connected to the first slave in the RS-485 network. In this way the base stations provide communications between a single Host and all readers in the system. STARGATE™ base stations are used as slaves in this network. The Slaves at the ends of the network must be terminated (see
the STARGATE™ and STAR-Box™ Installation Manuals and section 2.8.3).
See sections 4.6 and 4.7 or the original manufacturer’s Datalogic Aladdin™ Help On-
Line for system configuration specifications.
21
POWERSCAN ® D8330/M8300
3.2.2 BC-8060 Master Layout
Internal
Termination
C
D
RS-485 + VDC
RS-485 Only C
A
Internal
Termination
B
CAB-428 Splitter
RS-485 Only
USB, or RS-232, or Wedge, or Pen Emulation
A. Host
B. BC-8060
Slave
D. STARGATE™ base station
Example Multidrop STAR-System™ Network with BC-8060 as Master
In this layout a BC-8060 cradle acts as the Master. The Host is connected to the
BC-8060 Master using any one of the multi-standard interfaces (RS-232, USB,
WEDGE, or PEN Emulation). The Master is then connected to the slaves in the RS-485 network. In this way the slave cradles provide communications between a single Host and all readers in the system. STARGATE™ base stations can also be used as slaves in this network. The devices at the ends of the network must be terminated (see section
See sections 4.6 and 4.7 or the original manufacturer’s Datalogic Aladdin™ Help On-
Line for system configuration specifications.
22
POWERSCAN ® M8300 SYSTEM AND NETWORK LAYOUTS
3.2.3 Master BC-8060 Network Troubleshooting
Two diagnostic strings can be sent via RS-232 from the Host to the Master cradle in order to have feedback about the network itself.
#+LSlave
Returns a list of all the Slaves recognized at boot up.
Example:
In a network where the Master cradle has address 0188 and one Slave cradle with address 0001, the response is:
188
1
#+Alive<xxxx>
Executes a continuous Alive request to the slave xxxx in order to monitor the performance of the connection. A diagnostic message is displayed on the Host.
Example:
If this command is sent for slave cradle with address 0032, the response is:
/*32: BC-80X0 SOFTWARE RELEASE 1.00 20/10/2006*/ if there are no communication errors
/*32: FAIL*/ if there are communication errors.
To exit from this command, reset the system by cycling power to the Master cradle.
23
POWERSCAN ® D8330/M8300
4 CONFIGURATION
4.1
4.1.1
CONFIGURATION METHODS
Reading Configuration Bar Codes
This manual can be used for complete setup and configuration of your reader by
following the setup procedures in this chapter (see section 4.2 for an overview).
If you wish to change the default settings, this manual provides complete configuration of your reader in an easy way.
To configure your reader:
1)
Open the folded page in Appendix C with the hex-numeric table and keep it
open during the device configuration.
2) Read the Enter Configuration code ONCE, available at the top of each page of configuration.
3) Modify the desired parameters in one or more sections following the procedures given for each group.
4) Read the Exit and Save Configuration code ONCE, available at the top of each page of configuration.
Reference notes describing the operation of the more complex parameters are given
4.1.2 Using the Original Manufacturer’s Datalogic
Aladdin™
The original manufacturer’s Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-friendly configuration method via the RS-232/USB-COM interface.
It also allows upgrading the software of the connected device (see the original manufacturer’s Datalogic Aladdin™ Help On-Line for more details).
24
CONFIGURATION
4.1.3 Copy Command
A previously configured device (Master), can be used to send its configuration directly to other devices of the same type (Slaves). The particular procedure for each device is
4.1.4 Sending Configuration Strings from Host
An alternative configuration method is provided in Appendix A using the RS-232
interface. This method is particularly useful when many devices need to be configured with the same settings. Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily.
4.2 SETUP PROCEDURES
For PowerScan
®
D8330 Series readers, follow the setup procedures in sections 4.3,
For PowerScan ® M8300 Series readers, the setup procedures depend on two basic applications, Stand-alone or STAR-System™.
Stand-alone applications allow communication with the Host by either the BC-80X0
cradle (section 4.5), or by the STAR-Modem™ radio modem (section 4.5.2).
STAR-System™ applications allow communication with the Host through an
RS-485 network by the STARGATE™ RF base station or by the BC-8000 cradle
Proceed as shown in the following diagram:
25
POWERSCAN ® D8330/M8300
Begin Setup by choosing the setup procedure for your PowerScan reader as indicated below.
®
STAR-System™ Network Applications
BC-8000
Par. 4.6
PowerScan
®
Par. 4.3
Par. 4.7
D8330
Stand Alone Applications
PowerScan
®
M8300/BC-80X0
Par. 4.4
Par. 4.7
Optional Par. 4.4.1 multiple readers per BC-8000
PowerScan
®
M8300/STAR-Modem™ in Stand Alone Mode
Par. 4.4.2
STAR-System™ Applications
PowerScan
®
M8300/STAR-System™
Par. 4.5
•
STARGATE™
•
BC-8000 Network
•
STAR-Modem™ in STAR-System™ Mode
End of Setup
Your reader is now ready to read barcodes using the default settings.
26
CONFIGURATION
4.3 POWERSCAN ® D8330 SETUP
1.
Read the restore default parameters code below.
Restore PowerScan ® D8330 Default
Ì$+$*oÎ
4.4
After reading the above code, go to section 4.8 Interface Selection.
POWERSCAN ® M8300/BC-80X0 POINT-TO-POINT SETUP
A rapid configuration procedure has been devised for point-to-point applications where a single reader is associated exclusively with its own BC-80X0 base station and where it is not necessary to set the Date and Time parameters.
A special pre-printed bind-address label provided in the BC-80X0 base station package can be used to bind the PowerScan
®
M8300 reader to the base station with the address coded on the label. The address is also written numerically on the label to be easily recognized. Valid addresses are in the range from 0000 to 1999. Make
sure that all cradles used in the same area have different addresses.
To rapidly configure your point-to-point application:
1.
Apply the bind-address label onto the BC-80X0 base station as indicated in the BC-80X0 Quick Reference Guide.
2.
When the BC-80X0 cradle is connected and powered, read the
Bind-Address label to pair the PowerScan
®
M8300 to the BC-80X0 cradle.
The green LED on the PowerScan
®
M8300 will blink: the reader is ready to be positioned onto the cradle.
3.
Firmly position the reader onto the cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan ® M8300, and the green LED on the reader will go off.
Green LED
If it ever becomes necessary to change the reader, just read the bind-address label applied to the cradle and position the new reader onto the cradle.
Do not use multiple readers with this configuration method.
4.
Configure the BC-80X0 Cradle, refer to the “BC-80X0 Cradle Quick
Reference Guide”.
END of procedure. YOUR READER IS NOW READY TO READ CODES.
27
POWERSCAN ® D8330/M8300
4.5
1.
2.
3.
4.
POWERSCAN ® M8300/BC-80X0 STAND-ALONE SETUP
Read the restore default parameters code below.
Restore PowerScan
®
M8300 Default
Ì$+$*oÎ
Follow the procedure below to set the radio address and bind PowerScan
®
M8300 to the BC-80X0 cradle.
Enter Configuration
Ì$+;Î
Set Date
ÌIA%Î
+ six digits for Day, Month and Year (DDMMYY)
Set Time
ÌIB'Î
+ four digits for Hour and Minutes (HHMM)
28
CONFIGURATION
5.
Set Radio Address
ÌRA0RFHÎ
four digits for the PowerScan
+
®
M8300 Address (from 0000 to 1999).
All readers used in the same area must have different addresses.
6. Exit and Save Configuration
Ì$-?Î
7.
Read the Bind code to pair the PowerScan
® M8300 to the BC-80X0 cradle.
The reader is dedicated to the cradle. Any previously bound reader will be excluded.
To connect several readers to the same cradle see section 4.5.1, ‘Using
Multiple M8300 Series Readers with Same Cradle'.
Bind
Ì$+RN0$-IÎ
The green LED on the PowerScan ®
M8300 will blink; the reader is ready to be inserted into the cradle.
8. Firmly insert the reader into the BC-80X0 cradle within 10 seconds, a beep will be emitted, signaling that the BC-80X0 cradle has been paired to the
PowerScan
®
M8300, and the green LED on the reader will go off. green LED
29
POWERSCAN ® D8330/M8300
9.
Read the BC-80X0 restore default code:
Restore BC-80X0 Default
Ì$+RX0$-qÎ
Go to section 4.8 Interface Selection.
4.5.1 Using Multiple M-Series Readers with Same Cradle
If you want to use several M-Series readers with the same BC-80X0 cradle, you must first Bind the cradle with one of the readers (see previously described configuration procedure).
Successive readers can be associated with the same cradle by following the configuration procedure substituting the Bind command with Join (step 7).
7.
Join
Ì$+RN1$-NÎ
The green LED on the PowerScan
®
M8300 will blink: the reader is ready to be positioned onto the cradle. Complete step 8.
END of procedure.
CAUTION
All readers associated with the same cradle must have different addresses.
YOUR READER IS NOW READY TO READ BAR CODES.
To change the defaults see section 4.10.
30
CONFIGURATION
4.5.2 PowerScan ® M8300/STAR-Modem™ in Stand-Alone Mode
To configure a PowerScan
®
M8300 reader to communicate with STAR-Modem™ in
Stand-alone Mode, follow the procedure in section 4.5 substituting steps 6 and 7 with
those below:
6. STAR-Modem™ Address
ÌRSRÎ
Read the code above and the four-digit address of the STAR-Modem™.
7.
Exit and Save configuration
Ì$-?Î
END of procedure.
YOUR READER IS NOW READY TO READ BAR CODES.
To change the defaults see section 4.10.
31
POWERSCAN ® D8330/M8300
4.6 POWERSCAN ® M8300/STAR-SYSTEM™ SETUP
The following procedure allows configuring a PowerScan
®
M8300 reader to communicate with various STAR-System™ devices such as STARGATE™ RF base stations.
1.
Restore PowerScan ® M8300 Default
Ì$+$*oÎ
2.
Enter Configuration
Ì$+;Î
3.
Set Date
ÌIA%Î
+ six digits for Day, Month and Year (DDMMYY)
4.
Set Time
5.
ÌIB'Î
+ four digits for Hour and Minutes (HHMM)
Set the connection according to the length of the codes to be read:
Code Length ≤240 Characters
ÌRA1aÎ
Code Length >240 Characters
(not for systems with BC-8000 as Master)
ÌRA2dÎ
32
CONFIGURATION
6.
7.
8.
Set Radio Address
ÌRF8Î
+ four digits from the Numeric Table in the range 0000-1999.
All readers must have different addresses.
First STAR-System™ Address
ÌRSRÎ
Read the code above and the four-digit address of the First STAR-System™ device in the system.
Set Last STAR-System™ Address
ÌRTTÎ
Read the code above and the four-digit address of the Last STAR-System™ device in the system.
NOTE
Whenever the system is composed of a single base station, the first and last base station addresses (steps 7 and 8) must have the same value.
9.
Exit and Save Configuration
Ì$-?Î
END of procedure.
YOUR READER IS NOW READY TO READ BAR CODES.
To change the defaults see section 4.10.
33
POWERSCAN ® D8330/M8300
4.7 BC-8060 STAR-SYSTEM™ NETWORK SETUP
When the BC-8060 cradle model is used in an RS-485 network, it must be initially configured. To do this using configuration bar codes, follow the procedure below using any PowerScan
®
M8300 reader.
1.
Set BC-8060 Address
Ì$+RF4Î
+ four digits for the BC-8060 Address (from 0000 to 1999).
All cradles used in the network must have different addresses.
2.
Exit and Save configuration
Ì$-?Î
3.
Read the Bind code to pair the PowerScan configuration.
Bind
®
M8300 to the BC-8060 cradle for
Ì$+RN0$-IÎ
The green LED on the PowerScan ® M8300 will blink; the reader is ready to be inserted into the cradle.
4.
Firmly insert the reader into the BC-8060 cradle within 10 seconds, a beep will be emitted, signaling that the BC-8060 cradle has been paired to the
PowerScan
®
M8300, and the green LED on the reader will go off.
green LED
34
CONFIGURATION
5.
Read the BC-8060 restore default code:
Restore BC-8060 Default
Ì$+RX0$-qÎ
6.
Read the desired Enable Network code.
Enable RS-485 Master
Ì$+RZ2$-ÇÎ
Enable RS-485 Slave
Ì$+RZ1$-~Î
END of procedure.
For Host Master Network Layouts (see section 3.2), The network configuration
parameters can be changed through STAR-Link™ software running on the PC.
Star-Link™ software can be downloaded for free from the original Manufacturer’s web site: www.scanning.datalogic.com.
For BC-8060 Master Network Layouts (see section 3.2), The network configuration
parameters can be changed either through the original manufacturer’s Datalogic
Aladdin™ configuration software running on the PC or by reading the bar code
selections in the Network section of this manual starting on page 65. If using
configuration bar codes, it is advised to completely configure the cradles before reconfiguring the PowerScan
®
M8300 reader (see below).
NOTE
After completing the BC-8060 cradle configuration and connections in the network, you must reconfigure the
PowerScan
®
M8300 reader using the STAR-System™ procedure
35
POWERSCAN ® D8330/M8300
4.8 INTERFACE SELECTION
Read the interface selection code for your application.
RS-232
Standard
Ì$+CP0$-$Î
POS TERMINALS
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
ICL Mode
Ì$+CM0$-ÃÎ
For POS terminal default settings refer to section 5.15.
Ì$+CM1$-ÈÎ
PEN
Ì$+CP6$-BÎ
36
CONFIGURATION
WEDGE
IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
IBM XT
Ì$+CP503$-vÎ
PC Notebook
Ì$+CP505$-ÈÎ
IBM SURE1
Ì$+CP506$-$Î
IBM Terminal 3153
Ì$+CP504$-}Î
IBM Terminals 31xx, 32xx, 34xx, 37xx:
To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code.
Select the KEYBOARD TYPE if necessary (default = advanced keyboard).
KEY TRANSMISSION MODE make-only keyboard
Ì$+CP502$-oÎ
make-break keyboard
KEYBOARD TYPE
Ì$+CP501$-hÎ
advanced keyboard
Ì$+FK1$-ÉÎ
typewriter keyboard
Ì$+FK0$-ÄÎ
37
POWERSCAN ® D8330/M8300
WEDGE (CONTINUED)
ALT MODE
The ALT-mode selection allows bar codes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used. You do not need to make a
Keyboard Nationality selection.
(default = Num Lock Unchanged). Make sure the Num Lock key on your keyboard is ON.
IBM AT - ALT mode
Ì$+CP507$-+Î
PC Notebook - ALT mode
Ì$+CP508$-2Î
WYSE TERMINALS
ANSI Keyboard
Ì$+CP509$-9Î
PC Keyboard
Ì$+CP510$-gÎ
ASCII Keyboard
Ì$+CP511$-nÎ
VT220 style Keyboard
Ì$+CP514$-ÇÎ
DIGITAL TERMINALS
VT2xx/VT3xx/VT4xx
Ì$+CP512$-uÎ
38
CONFIGURATION
4.9 USB READER CONFIGURATION
The USB interface is available for PowerScan
®
D8330, BC-80X0 and C-8000 devices and is compatible with the following Operating Systems:
Windows ® 98 (and later) IBM ® POS for Windows
Mac
®
OS 8.0 (and later)
USB Start-up
4690 Operating System
As with all USB devices, upon connection, the Host performs several checks by communicating with the device. During this phase normal operations are suspended
(the LED on the PowerScan ® D8330 reader blinks). Two basic conditions must be met before the device is ready, the correct USB driver must be loaded and sufficient power must be supplied to the reader. c For all systems, the correct USB driver for the default USB-KBD interface is included in the Host
Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only).
1
First Start-Up
Connect device to
Host reader LED blinks
Normally the Host supplies sufficient power to the device and the start-up phase ends correctly. (The reader's LED stops blinking and the reader emits the beep OK signal).
Load drivers
(if requested) reader LED off - BEEP OK
2
Select desired USB interface code
(USB-KBD is default)
In rare cases, if the Host does not supply sufficient power to the device, a dialog box will appear on the Host and the device will be blocked (the reader's LED continues blinking). In this case, disconnect the USB device cable at the
Host (the reader's LED stops blinking), and then try a different USB port as indicated by the
Operating System message. (The device emits the beep OK signal. You can now read codes).
Load drivers
(if requested)
Read test codes.
Device is READY d At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the
USB-COM interface, the relevant files and drivers must be installed from the USB
Device Installation software, which can be downloaded from the original
Manufacturer’s web page at http://www.scanning.datalogic.com.
The device is ready. Successive start-ups will automatically recognize the previously loaded drivers.
39
POWERSCAN ® D8330/M8300
USB
USB-KBD
Ì$+UA03$-:Î
USB-KBD-ALT-MODE
Ì$+UA04$-@Î
USB-KBD-APPLE
Ì$+UA05$-FÎ
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Table Top
Ì$+UA00$-(Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
* When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software, which can be downloaded from the original
Manufacturer’s web site at http://www.scanning.datalogic.com.
40
CONFIGURATION
4.10 CHANGING DEFAULT SETTINGS
Once your reader is setup, you can change the default parameters to meet your application needs. Refer to the preceding paragraphs for initial configuration in order to set the default values and select the interface for your application.
In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group.
The first four groups are for Standard Interface parameter configuration for all
PowerScan
®
D8330 series readers and PowerScan
®
M8300/BC-80X0 Stand-alone configurations only:
RS-232
USB
WEDGE
PEN EMULATION
NETWORK PARAMETERS are available only for BC-8060 Network configurations.
The following parameter groups are common to all interface applications:
DATA FORMAT parameters regard the messages sent to the Host system for all interfaces except Pen Emulation.
POWER SAVE manages overall current consumption in the reading device.
READING PARAMETERS control various operating modes and indicator status functioning.
DECODING PARAMETERS maintain correct bar code decoding in certain special reading conditions.
CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options.
ADVANCED FORMATTING PARAMETERS allow code concatenation and advanced formatting of messages towards the Host. It cannot be used with Pen
Emulation connections.
RADIO PARAMETERS (M8300 series only) allow configuration of radio control parameters.
DISPLAY PARAMETERS (some M8300 series models only) allow configuration of reader display parameters.
41
RS-232 PARAMETERS
All PowerScan
®
D8330 Series readers
+
PowerScan
®
M8300/BC-80X0 configurations only
~
~
~
~
~
~
~
~
~
B AUD R ATE
P ARITY
D ATA B ITS
S TOP B ITS
H ANDSHAKING
A CK /N ACK P ROTOCOL
F IFO
I NTER CHARACTER D ELAY
R X T IMEOUT
~
~
~
~
~
~
~
~
~
~ ~ S ERIAL T RIGGER L OCK
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
42
Enter Configuration
Ì$+;Î
300 baud
ÌCD1XÎ
1200 baud
ÌCD3^Î
4800 baud
ÌCD5dÎ
19200 baud
ÌCD7jÎ
none
ÌCC0SÎ
odd parity
ÌCC2YÎ
RS-232
B AUD R ATE
P ARITY
Exit and Save Configuration
Ì$-?Î
600 baud
ÌCD2[Î
2400 baud
ÌCD4aÎ
9600 baud
ÌCD6gÎ
38400 baud
ÌCD8mÎ
even parity
ÌCC1VÎ
43
Enter Configuration
Ì$+;Î
7 bits
ÌCA0OÎ
9 bits
ÌCA2UÎ
1 stop bit
ÌCB0QÎ
disable
ÌCE0WÎ
software (XON/XOFF)
ÌCE2]Î
RS-232
D ATA B ITS
Exit and Save Configuration
Ì$-?Î
8 bits
ÌCA1RÎ
S TOP B ITS
2 stop bits
ÌCB1TÎ
H ANDSHAKING hardware (RTS/CTS)
ÌCE1ZÎ
See section 5.1.1 for details.
RTS always ON
ÌCE3`Î
44
Enter Configuration
Ì$+;Î
RS-232
A CK /N ACK P ROTOCOL
disable
ÌER0sÎ
enable
ÌER1vÎ
See section 5.1.2 for details, particularly on implementing this parameter with PowerScan
M8300.
®
FIFO
Exit and Save Configuration
Ì$-?Î
disable
ÌEC0UÎ
enable
ÌEC1XÎ
See section 5.1.3 for details.
I NTER CHARACTER D ELAY delay between characters transmitted to Host
ÌCK3Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
45
Enter Configuration
Ì$+;Î
RS-232
R X T IMEOUT timeout control in reception from Host
ÌCL5Î
Read 2 numbers from the table where:
00 = TIMEOUT disabled
01-99 = TIMEOUT from .1 to 9.9 seconds
rx timeout 5 seconds
See section 5.1.4 for details.
Exit and Save Configuration
Ì$-?Î
S ERIAL T RIGGER L OCK
disabled
ÌCR0qÎ
enable and select characters
ÌCR1tÎ
Read 2 characters from the Hex/Numeric table in the range 00-FE where:
− First Character enables device trigger
− Second Character inhibits device trigger until the first character is received again.
46
USB PARAMETERS
~ USB-COM
Handshaking, Ack/Nack protocol, FIFO,
Inter-character delay, Rx timeout, Serial trigger lock
~
~ USB-KBD
Keyboard nationality, FIFO, Inter-character delay, Inter-code delay, USB keyboard speed
~
~ ~ USB-IBM
No parameter selection required.
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
47
Enter Configuration
Ì$+;Î
USB-COM
Exit and Save Configuration
Ì$-?Î
H ANDSHAKING
disable
ÌCE0WÎ
hardware (RTS/CTS)
ÌCE1ZÎ
software (XON/XOFF)
ÌCE2]Î
RTS always ON
ÌCE3`Î
See section 5.1.1 for details.
A CK /N ACK P ROTOCOL
disable
ÌER0sÎ
enable
ÌER1vÎ
See section 5.1.2 for details, particularly on implementing this parameter with PowerScan
M8300.
®
FIFO disable
ÌEC0UÎ
enable
ÌEC1XÎ
See section 5.1.3 for details.
48
Enter Configuration
Ì$+;Î
USB-COM
I NTER CHARACTER D ELAY delay between characters transmitted to Host
ÌCK3Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
Exit and Save Configuration
Ì$-?Î
R X T IMEOUT timeout control in reception from Host
ÌCL5Î
Read 2 numbers from the table where:
00 = TIMEOUT disabled
01-99 = TIMEOUT from .1 to 9.9 seconds
rx timeout 5 seconds
See section 5.1.4 for details.
S ERIAL T RIGGER L OCK
disabled
ÌCR0qÎ
enable and select characters
ÌCR1tÎ
Read 2 characters from the Hex/Numeric table in the range 00-FE where:
− First Character enables device trigger
− Second Character inhibits device trigger until the first character is received again.
49
Enter Configuration
Ì$+;Î
USB-KBD
Exit and Save Configuration
Ì$-?Î
K EYBOARD N ATIONALITY
Not Available for USB-KBD-ALT-MODE Interface
This parameter default value is restored through the Interface Selection code and not Restore
Default.
Belgian
ÌFJ7yÎ
English (UK)
ÌFJ4pÎ
French
ÌFJ2jÎ
German
ÌFJ3mÎ
Italian
ÌFJ1gÎ
Spanish
ÌFJ6vÎ
Swedish
ÌFJ5sÎ
USA
ÌFJ0dÎ
50
Enter Configuration Exit and Save Configuration
Ì$+;Î
USB-KBD
Ì$-?Î
The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs.
Japanese
ÌFJ8|Î
Russian (Latin)
ÌFJ9ÃÎ
Russian (Cyrillic)
ÌFJA0Î
Hungarian
ÌFJB3Î
Slovenian, Croatian,
Serbian (Latin)
ÌFJC6Î
Romanian
ÌFJD9Î
Czech Republic
ÌFJE<Î
FIFO disable
ÌEC0UÎ
enable
ÌEC1XÎ
See section 5.1.3 for details.
51
Enter Configuration
Ì$+;Î
USB-KBD
I NTER CHARACTER D ELAY delay between characters transmitted to Host
ÌCK3Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
Exit and Save Configuration
Ì$-?Î
I NTER CODE D ELAY delay between codes transmitted to Host
ÌFG.Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 seconds
delay disabled
Normal
ÌUT10cÎ
USB K EYBOARD S PEED
Fast
ÌUT01dÎ
52
WEDGE PARAMETERS
All PowerScan
®
D8330 Series readers
+
PowerScan
®
M8300/BC-80X0 configurations only
~
~
~
~
~
~
~
K EYBOARD N ATIONALITY
C APS L OCK
C APS L OCK
A UTO RECOGNITION
N UM L OCK
I NTER CHARACTER D ELAY
I NTER CODE D ELAY
K EYBOARD S ETTING
~
~
~
~
~
~
~
~
W
EDGE
C
ONTROL
C
HARACTER
E
MULATION
~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
53
Enter Configuration
Ì$+;Î
Belgian
ÌFJ7yÎ
WEDGE
K EYBOARD N ATIONALITY
French
ÌFJ2jÎ
Italian
ÌFJ1gÎ
Swedish
ÌFJ5sÎ
Exit and Save Configuration
Ì$-?Î
English (UK)
ÌFJ4pÎ
German
ÌFJ3mÎ
Spanish
ÌFJ6vÎ
USA
ÌFJ0dÎ
54
Enter Configuration Exit and Save Configuration
Ì$+;Î
WEDGE
Ì$-?Î
The Japanese and Eastern Block Keyboard Nationality selections are valid only for IBM AT compatible PCs.
Japanese
ÌFJ8|Î
Russian (Latin)
ÌFJ9ÃÎ
Russian (Cyrillic)
ÌFJA0Î
Hungarian
ÌFJB3Î
Slovenian, Croatian,
Serbian (Latin)
ÌFJC6Î
Romanian
ÌFJD9Î
Czech Republic
ÌFJE<Î
C APS L OCK
caps lock OFF
ÌFE0ZÎ
caps lock ON
ÌFE1]Î
Select the appropriate code to match your keyboard caps lock status.
Note: Caps lock manual configuration is ignored when Caps Lock Auto-Recognition is enabled.
For PC Notebook interface selections, the caps lock status is automatically recognized; therefore this command is not necessary.
55
Enter Configuration
Ì$+;Î
WEDGE
Exit and Save Configuration
Ì$-?Î
C APS L OCK A UTO -R ECOGNITION (IBM AT COMPATIBLE ONLY ) disable
ÌFP0pÎ
enable
ÌFP1sÎ
N UM L OCK toggle num lock
ÌFL1kÎ
num lock unchanged
ÌFL0hÎ
This selection is used together with the Alt Mode interface selection for AT or Notebook PCs.
It changes the way the Alt Mode procedure is executed; therefore it should be set as follows:
• if your keyboard Num Lock is normally on use num lock unchanged
• if your keyboard Num Lock is normally off use toggle num lock
In this way the device will execute the Alt Mode procedure correctly for your application.
I NTER CHARACTER D ELAY delay between characters transmitted to Host
ÌCK3Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 milliseconds
delay disabled
56
Enter Configuration
Ì$+;Î
WEDGE
Exit and Save Configuration
Ì$-?Î
I NTER CODE D ELAY delay between codes transmitted to Host
ÌFG.Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from 1 to 99 seconds
delay disabled
K EYBOARD S ETTING
ALPHANUMERIC KEYBOARD SETTING
The device (reader or cradle) can be used with terminals or PCs with various keyboard types and nationalities through a simple keyboard setting procedure.
The type of computer or terminal must be selected before activating the keyboard setting command.
Keyboard setting consists of communicating to the device how to send data corresponding to the keyboard used in the application. The keys must be set in a specific order.
Press and release a key to set it.
Some characters may require more than one key pressed simultaneously during normal use
(refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the reader in this case pressing and releasing the different keys.
Example:
If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4".
Each pressed and released key must generate an acoustic signal on the device; otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard.
Press "Backspace" to correct a wrong key entry. In this case the device emits 2 beeps.
Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS
LOCK". setting the alphanumeric keyboard
ÌFB0TÎ
Read the code above.
Press the keys shown in the following table according to their numerical order.
57
WEDGE
Some ASCII characters may be missing as this depends on the type of keyboard: these are generally particular characters relative to the various national symbologies. In this case:
• The first 4 characters (Shift, Alt, Ctrl, and Backspace) can only be substituted with keys not used, or substituted with each other.
• characters can be substituted with other single symbols (e.g. "SPACE") even if not included in the bar code set used.
• characters can be substituted with others corresponding to your keyboard.
The device signals the end of the procedure with 2 beeps indicating the keys have been registered.
01 : Shift
02 : Alt
03 : Ctrl
04 : Backspace
CAUTION
Do not place the reader onto the BC-80X0 cradle during this procedure.
Otherwise, the battery charging will occur modifying the LEDs functioning.
58
Enter Configuration
Ì$+;Î
Ctrl + Shift + Key
ÌFO0nÎ
WEDGE
C ONTROL C HARACTER E MULATION
Exit and Save Configuration
Ì$-?Î
Ctrl + Key
ÌFO1qÎ
59
PEN EMULATION
All PowerScan
®
D8330 Series readers
+
PowerScan
®
M8300/BC-80X0 configurations only
~
~
~
~
~
~
O PERATING M ODE
M INIMUM O UTPUT P ULSE
C ONVERSION TO C ODE 39
O VERFLOW
O UTPUT L EVEL
I DLE L EVEL
~
~
~
~
~
~
~ I NTER -B LOCK D ELAY ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
60
PEN EMULATION
The operating mode parameters are complete commands and do not require reading the
Enter and Exit configuration codes.
O PERATING M ODE
interpret mode
Ì$]8Î
Interprets commands without sending them to the decoder. transparent mode
Ì$[4Î
Sends commands to the decoder without interpreting them.
61
Enter Configuration
Ì$+;Î
200 μs
ÌDG0\Î
PEN EMULATION
M INIMUM O UTPUT P ULSE high resolution code emulation
Exit and Save Configuration
Ì$-?Î
400 μs
ÌDG1_Î
600 μs
ÌDG2bÎ
800 μs
ÌDG3eÎ
1 ms
ÌDG4hÎ
1.2 ms
ÌDG5kÎ
low resolution code emulation
See section 5.2.1 for details.
62
Enter Configuration
Ì$+;Î
PEN EMULATION
Exit and Save Configuration
Ì$-?Î
C ONVERSION TO C ODE 39 (D8330 S ERIES O NLY )
disable conversion to Code 39
ÌDA0PÎ
Transmits codes in their original format. enable conversion to Code 39
ÌDA1SÎ
Converts codes read into
Code 39 format.
See section 5.2.2 for details.
C ONVERSION TO C ODE 39 AND C ODE 128 (M8300 S ERIES O NLY )
enable conversion to Code 39
ÌDA1SÎ
Converts codes read into Code
39 format. enable conversion to Code 128
ÌDA0PÎ
Converts codes read into Code
128 format.
See section 5.2.2 for details.
O VERFLOW narrow
ÌDH0^Î
medium
ÌDH1aÎ
wide
ÌDH2dÎ
See section 5.2.3 for details.
63
Enter Configuration
Ì$+;Î
normal
ÌDD0VÎ
(white = logic level 0)
PEN EMULATION
O UTPUT L EVEL
Exit and Save Configuration
Ì$-?Î
inverted
ÌDD1YÎ
(white = logic level 1)
See section 5.2.4 for details.
normal
ÌDE0XÎ
(black level)
I DLE L EVEL inverted
ÌDE1[Î
(white level)
See section 5.2.4 for details.
I NTER -B LOCK D ELAY delay between character blocks transmitted to Host
ÌCK3Î
Read 2 numbers from the table where:
00 = DELAY disabled
01-99 = DELAY from .1 to 9.9 seconds
delay disabled
See section 5.2.5 for details.
64
NETWORK PARAMETERS
BC-8060 model configurations only
~
~
~
~
~
~
RS-485 N ETWORK
N ETWORK B AUD R ATE
S LAVE A DDRESS R ANGE
N ETWORK W ARNING M ESSAGE
R ECEPTION W ARNING
M ESSAGE
M ASTER C RADLE H EADER
~
~
~
~
~
~
~ M ASTER C RADLE T ERMINATOR ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
65
Enter Configuration
Ì$+;Î
NETWORK PARAMETERS
Exit and Save Configuration
Ì$-?Î
RS-485 N ETWORK
disable RS-485 network
ÌRZ0)Î
enable RS-485 master
ÌRZ2/Î
NOTE
enable RS-485 slave
ÌRZ1,Î
If a BC-8060 cradle is errantly configured as a Slave but not connected to a network, it may not be able to receive further commands from the reader. In this case it can be reconfigured by executing the bind procedure, which returns the cradle to Stand-alone configuration.
N ETWORK B AUD R ATE
9600
ÌJE0^Î
19200
ÌJE1aÎ
38400
ÌJE2dÎ
66
Enter Configuration
Ì$+;Î
NETWORK PARAMETERS
Exit and Save Configuration
Ì$-?Î
S LAVE A DDRESS R ANGE
First Address
ÌJB(Î
Read the code above and the four-digit address of the First Slave device in the system.
Last Address
ÌJC*Î
Read the code above and the four-digit address of the Last Slave device in the system.
See section 5.3.1 for details.
N ETWORK W ARNING M ESSAGE
network warning message not transmitted
ÌJG0bÎ
network warning message transmitted
ÌJG1eÎ
See section 5.3.2 for details.
R ECEPTION W ARNING M ESSAGE reception warning message not transmitted
ÌJH0dÎ
reception warning message transmitted
ÌJH1gÎ
See section 5.3.3 for details.
67
Enter Configuration
Ì$+;Î
NETWORK PARAMETERS
Exit and Save Configuration
Ì$-?Î
M ASTER C RADLE H EADER
no header
ÌJA00/Î
one character header two character header
ÌJA013Î
ÌJA027Î
three character header four character header
ÌJA03;Î
ÌJA04?Î
five character header six character header
ÌJA05CÎ
ÌJA06GÎ
seven character header eight character header
ÌJA07KÎ
ÌJA08OÎ
After selecting one of the desired Header codes, read the character(s) from the HEX table.
Valid characters are in the range: 00-FE
Example:
four character header
+ 41 + 42 + 43 + 44 = Header ABCD
For more details about default and WEDGE Interface Extended Keyboard values, see
sections 5.3.4, 5.4.1 and 5.4.2.
68
Enter Configuration
Ì$+;Î
NETWORK PARAMETERS
Exit and Save Configuration
Ì$-?Î
M ASTER C RADLE T ERMINATOR
no terminator
ÌJA102Î
one character terminator two character terminator
ÌJA116Î
ÌJA12:Î
three character terminator four character terminator
ÌJA13>Î
ÌJA14BÎ
five character terminator six character terminator
ÌJA16JÎ
ÌJA15FÎ
seven character terminator eight character terminator
ÌJA17NÎ
ÌJA18RÎ
After selecting one of the desired Terminator codes, read the character(s) from the HEX table.
Valid characters are in the range: 00-FE
Example: two character terminator
+ 0D + 0A = Terminator CR LF
For more details about default and WEDGE Interface Extended Keyboard values, see
sections 5.3.4, 5.4.1 and 5.4.2.
69
DATA FORMAT
NOT FOR PEN INTERFACES
~
~
~
~
~
~
~
~
~
~
~
~
C ODE I DENTIFIER
C USTOM C ODE I DENTIFIER
H EADER
T ERMINATOR
S PECIAL K EYS
F IELD A DJUSTMENT
F IELD A DJ .
C HARACTER
C ODE L ENGTH T X
C HARACTER R EPLACEMENT
A DDRESS S TAMPING
A DDRESS D ELIMITER
T IME S TAMPING
~
~
~
~
~
~
~
~
~
~
~
~
~ ~ T IME D ELIMITER
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
70
2/5 interleaved
2/5 industrial
2/5 normal 5 bars
2/5 matrix 3 bars
EAN 8
EAN 13
UPC A
UPC E
EAN 8 with 2 ADD ON
EAN 8 with 5 ADD ON
EAN 13 with 2 ADD ON
EAN 13 with 5 ADD ON
UPC A with 2 ADD ON
UPC A with 5 ADD ON
UPC E with 2 ADD ON
UPC E with 5 ADD ON
Code 39
Code 39 Full ASCII
ABC CODABAR
Code 128
EAN 128
ISBT 128
Code 93
DATA FORMAT
CODE IDENTIFIER TABLE
Custom
STANDARD STANDARD
] E 5
] E 6
] E 1
] E 2
] X y
] X y
] X y
] X y
] A y
] A y
] I y N
] X y P
] S y
] X y
O
Q
] E 4
] E 0
] X y
] X y
A
B
C
D
J
K
L
M
F
G
H
I
V
W
] X y
] C y
] C y
] C4
] G y
S
T k f
U
Code 32 ] X y X
Code 11
Code 16K
Code 49
GS1 DataBar™ Expanded Linear and Stacked
] H y
] K 0
] T y
] e 0 b p q t
GS1 DataBar Limited
GS1 DataBar 14 Linear and Stacked
] e 0
] e 0 v u
• AIM standard identifiers are not defined for all codes: the X identifier is assigned to the code for which the standard is not defined. The y value depends on the selected options
(check digit tested or not, check digit tx or not, etc.).
• When customizing the Manufacturer Standard code identifiers, 1 or 2 identifier characters can be defined for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled).
• The code identifier can be singly disabled for any code by simply selecting FF as the first identifier character.
• Write in the Custom character identifiers in the table above for your records.
71
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
C ODE I DENTIFIER
disable
ÌEB0SÎ
Manufacturer Standard
ÌEB1VÎ
AIM standard
ÌEB2YÎ
custom
ÌEB3\Î
C USTOM C ODE I DENTIFIER define custom code identifier(s)
ÌEH/Î
c Read the above code.
(Code Identifiers default to Manufacturer Standard, see table on previous page). d Select the code type from the code table in Appendix
for the identifier you want to change. e You can define 1 or 2 identifier characters for each code type. If only 1 identifier character is required, the second character must be selected as FF (disabled). Read the hexadecimal value corresponding to the character(s) you want to define as identifiers for the code selected in step d: valid characters are in the range 00-FD.
Example: To define Code 39 Code Identifier = @
Read define custom code identifier(s) Code 39
ÌEH/Î
+
ÌVWÎ
+
40 + FF
72
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
H EADER no header
ÌEA00*Î
one character header two character header
ÌEA01.Î
ÌEA022Î
three character header four character header
ÌEA036Î
ÌEA04:Î
five character header six character header
ÌEA05>Î
ÌEA06BÎ
seven character header eight character header
ÌEA07FÎ
ÌEA08JÎ
After selecting one of the desired Header codes, read the character(s) from the HEX table.
Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible
to read the Special Key(s) on page 75.
Example:
four character header
+ 41 + 42 + 43 + 44 = Header ABCD
For more details see sections 5.4.1 and 5.4.2.
73
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
T ERMINATOR no terminator
ÌEA10-Î
one character terminator two character terminator
ÌEA125Î
four character terminator
ÌEA111Î
three character terminator
ÌEA139Î
ÌEA14=Î
five character terminator six character terminator
ÌEA15AÎ
ÌEA16EÎ
seven character terminator eight character terminator
ÌEA17IÎ
ÌEA18MÎ
After selecting one of the desired Header codes, read the character(s) from the HEX table.
Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible
to read the Special Key(s) on page 75.
Example: two character terminator
+ 0D + 0A = Terminator CR LF
For more details see sections 5.4.1 and 5.4.2.
74
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
S PECIAL K EYS
Available only for Wedge IBM AT-PS/2 and USB-KBD Interfaces
NOTE
It is necessary to define each Special Key by following the procedure given in
Select one or more of the following Special Keys according to your needs.
Special Key 1
Ì9CÄÎ
Special Key 2
Ì9DÆÎ
Special Key 3
Ì9EÈÎ
Special Key 4
Ì9FÊÎ
Special Key 5
ÌA0bÎ
75
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
F IELD A DJUSTMENT
disable field adjustment
ÌEF0[Î
Field adjustment allows a number of characters n, to be added to or subtracted from the bar code read. The adjustment can be different for each enabled code type. To define the field adjustment: c Read the enable field adjustment code: enable field adjustment
ÌEF+Î
d Select the code type from the Code Identifier Table in Appendix
e Select the type of adjustment to perform: right addition
Ì01Î
right deletion
Ì23Î
left addition
Ì12Î
left deletion
Ì34Î
f Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete:
Conditions:
• Adjustment is only performed on the bar code data, the Code Identifier and Code Length
Transmission fields are not modified by the field adjustment parameter.
• If the field setting would subtract more characters than exist in the bar code, the subtraction will take place only to code length 0.
• You can set up to a maximum of 10 different field adjustments on the same bar code family or on different bar code families.
Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment Code 39 right addition
Read
ÌEF+Î
+
ÌVWÎ
+
Ì01Î
+ 04
76
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
F IELD A DJUSTMENT C HARACTER c Read the field adjustment character code: field adjustment character
ÌEG-Î
d Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it
is also possible to read the Special Key(s) on page 75.
Example:
To define the field adjustment character = A: field adjustment character
Read + 41
C ODE L ENGTH T X
code length not transmitted
ÌEE0YÎ
code length transmitted in variable-digit format
ÌEE1\Î
code length transmitted in fixed 4-digit format
ÌEE2_Î
The code length is transmitted in the message after the Headers and Code Identifier characters.
The code length is calculated after performing any field adjustment operations.
77
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
C HARACTER R EPLACEMENT
disable character replacement
ÌEO0mÎ
This parameter allows up to three characters to be replaced from the bar code read. These substitutions are stored in memory. To define each character replacement: c Read one of the following character replacement codes:
ÌEO1pÎ
second character replacement
ÌEO2sÎ
ÌEO3vÎ
d From the Code Identifier Table in Appendix
B , read the Code Identifier for the desired
code family.
0 = character replacement will be effective for all code families. e From the Hex/Numeric Table read two characters corresponding to the Hex value
(00-FE), which identifies the character to be replaced. For Wedge and USB-KBD
interfaces, it is also possible to read the Special Key(s) on page 75.
f From the Hex/Numeric Table read two characters corresponding to the Hex value
(00-FE), which identifies the new character to replace. For Wedge and USB-KBD
interfaces, it is also possible to read the Special Key(s) on page 75.
FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.
78
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
Example:
The following strings define:
1. First Character Replacement: substitution in Code 39 bar codes of all occurrences of the
0 character with the 1 character.
2. Second Character Replacement: substitution in Code 39 bar codes of all occurrences of the A character with the B character. first character replacement Code 39
ASCII characters corresponding to the HEX value for character 0
ASCII characters corresponding to the HEX value for character 1
30 + 31
For Code 39 codes containing the string "0123", the contents transmitted will be "1123". second character replacement
Code 39
ASCII characters corresponding to the HEX value for character A
ASCII characters corresponding to the HEX value for character B
41 + 42
For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".
79
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
A DDRESS S TAMPING (M8300 S ERIES O NLY )
disable reader address stamping
ÌRU0ÊÎ
disable cradle address stamping
ÌRW0#Î
enable reader address stamping
ÌRU1"Î
enable cradle address stamping
ÌRW1&Î
See section 5.4.3 for details.
A DDRESS D ELIMITER (M8300 S ERIES O NLY )
disable reader address delimiter
ÌRV0!Î
enable reader address delimiter and select characters
disable cradle address delimiter
ÌRY0'Î
ÌRV1$Î
enable cradle address delimiter and select characters
ÌRY1*Î
Read 2 HEX characters in the range 00-FE. Read 2 HEX characters in the range 00-FE.
See section 5.4.4 for details.
80
Enter Configuration
Ì$+;Î
DATA FORMAT
Exit and Save Configuration
Ì$-?Î
T IME S TAMPING (M8300 S ERIES O NLY )
disable
ÌIL0kÎ
hour/minutes/seconds month/day/year
ÌIL1nÎ
hour/minutes/seconds day/month/year
ÌIL2qÎ
hour/minutes/seconds
ÌIL3tÎ
month/day/year
ÌIL4wÎ
day/month/year
ÌIL5zÎ
See section 5.4.5 for details.
T IME S TAMPING D ELIMITER (M8300 S ERIES O NLY )
disable
ÌIM0mÎ
select delimiter
ÌIM1pÎ
Read 2 HEX characters in the range 00-FE.
See section 5.4.6 for details.
81
~
POWER SAVE
S LEEP S TATE ~
~ ~ E NTER S LEEP T IMEOUT
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
82
Enter Configuration
Ì$+;Î
POWER SAVE
Exit and Save Configuration
Ì$-?Î
S LEEP S TATE
disable
ÌBQ0nÎ
enable
ÌBQ1qÎ
See section 5.5.1 for details.
For M8300 series readers, sleep state is entered immediately after reading a code and is not configurable.
E NTER S LEEP T IMEOUT enter sleep timeout
ÌBR@Î
Read 2 numbers in the range 00-99:
00 = Enter Sleep state immediately
01-99 = corresponds to a max. 9.9 sec. delay before entering the
Sleep state.
enter sleep timeout = 0.6 sec.
See section 5.5.2 for details.
83
READING PARAMETERS
~ T RIGGER T YPE ~
~
~
~
~
~
~
~
~
~
~
~
~
T RIGGER S IGNAL
T RIGGER C LICK
T RIGGER OFF T IMEOUT
F LASH M ODE
R EADS PER C YCLE
S AFETY T IME
B EEPER I NTENSITY
B EEPER T ONE
B EEPER T YPE
B EEPER L ENGTH
G OOD R EAD S POT D URATION
A IMING S YSTEM
~
~
~
~
~
~
~
~
~
~
~
~
~ C RADLE B EEPER I NTENSITY ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
84
Enter Configuration
Ì$+;Î
READING PARAMETERS
T RIGGER T YPE
hardware trigger
ÌBK1eÎ
Restores TRIGGER MODE
Exit and Save Configuration
Ì$-?Î
software trigger
ÌBK0bÎ
Enables FLASH MODE always on
ÌBK3kÎ
T RIGGER S IGNAL
trigger active level
ÌBA0NÎ
trigger active pulse
ÌBA1QÎ
See section 5.6.1 for details.
T RIGGER C LICK
disable
ÌBc0+Î
enable
ÌBc1.Î
See section 5.6.2 for details.
85
Enter Configuration
Ì$+;Î
READING PARAMETERS
T RIGGER OFF T IMEOUT
Exit and Save Configuration
Ì$-?Î
trigger-off timeout
ÌBD$Î
Read 2 numbers in the range 00-99:
00 = disables the trigger-off timeout
01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically.
trigger-off timeout disabled
See section 5.6.3 for details.
F LASH M ODE
"FLASH" ON duration
ÌBB0PÎ
"FLASH" OFF duration
ÌBB1SÎ
Read 2 numbers in the range 01-99:
01 to 99 = from .1 to 9.9 seconds.
Flash-ON = 1 sec. Flash-OFF = 0.6 sec
R EADS PER C YCLE
one read per cycle
ÌBC0RÎ
multiple reads per cycle
ÌBC1UÎ
See section 5.6.4 for details.
86
Enter Configuration
Ì$+;Î
READING PARAMETERS
Exit and Save Configuration
Ì$-?Î
S AFETY T IME safety time
ÌBE&Î
Limits same code consecutive reading.
Read 2 numbers in the range 00-99: no same code consecutive reading until reader is removed (no decoding) for at least 400 ms.
01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code.
safety time = 0.5 sec
See section 5.6.5 for details.
B EEPER I NTENSITY
* very low intensity
ÌBG0ZÎ
low intensity
ÌBG1]Î
medium intensity
ÌBG2`Î
high intensity
ÌBG3cÎ
* This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating
conditions described in section 7.5.
87
Enter Configuration
Ì$+;Î
READING PARAMETERS
B EEPER T ONE tone 1
ÌBH0\Î
tone 3
ÌBH2bÎ
B EEPER T YPE
monotone
ÌBJ0`Î
B EEPER L ENGTH long
ÌBI0^Î
Exit and Save Configuration
Ì$-?Î
tone 2
ÌBH1_Î
tone 4
ÌBH3eÎ
bitonal
ÌBJ1cÎ
short
ÌBI1aÎ
88
Enter Configuration
Ì$+;Î
READING PARAMETERS
G OOD R EAD S POT D URATION
Exit and Save Configuration
Ì$-?Î
disable
ÌBV0xÎ
short
ÌBV1{Î
medium
ÌBV2~Î
long
ÌBV3ÅÎ
A IMING S YSTEM
disabled
ÌBj09Î
enabled
ÌBj1<Î
disable
ÌJI0fÎ
C RADLE B EEPER I NTENSITY low intensity
ÌJI1iÎ
medium intensity
ÌJI2lÎ
high intensity
ÌJI3oÎ
89
DECODING PARAMETERS
~ I NK S PREAD ~
~
~
~
~
O VERFLOW C ONTROL
I NTERDIGIT C ONTROL
D ECODING S AFETY
P UZZLE S OLVER ™
~
~
~
~
CAUTION
Before changing these parameter values read the descriptions in
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
90
Enter Configuration
Ì$+;Î
DECODING PARAMETERS
I NK S PREAD disable
ÌAX0{Î
See section 5.7.1 for details.
O VERFLOW C ONTROL disable
ÌAW1|Î
See section 5.7.2 for details.
I NTERDIGIT C ONTROL disable
ÌAV0wÎ
See section 5.7.3 for details.
Exit and Save Configuration
Ì$-?Î
enable
ÌAX1~Î
enable
ÌAW0yÎ
enable
ÌAV1zÎ
91
Enter Configuration
Ì$+;Î
DECODING PARAMETERS
Exit and Save Configuration
Ì$-?Î
D ECODING S AFETY
one read
ÌED0WÎ
(decoding safety disabled) two reads
ÌED1ZÎ
three reads
ÌED2]Î
four reads
ÌED3`Î
Required number of good reads before accepting code.
P UZZLE S OLVER ™
disable
ÌAU0uÎ
enable
ÌAU1xÎ
In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of the single code to reconstruct it.
To read codes using this technology, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
Conditions:
• This parameter is only valid for the following codes:
EAN 8 without Add-on
Code 128
EAN 13 without Add-on
Code 39
UPC A without Add-on
• For Code 39, Check digit control is forced.
• PuzzleSolver ™ is not valid for ISBT 128 code.
92
CODE SELECTION
~ A UTO CONFIGURATION ~
~
~
~
~
~
~
~
~
~
~
EAN/UPC F AMILY
2/5 F AMILY
C ODE 39 F AMILY
C ODE 128 F AMILY
C ODABAR F AMILY
C ODE 93
MSI
C ODE 11
C ODE 16K
C ODE 49
~
~
~
~
~
~
~
~
~
~
~ ~ GS1 DATABAR C ODES
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
93
Code selections may be performed according to two different procedures:
- Auto-configuration, allowing an automatic recognition and selection of the code families to be read;
- Manual configuration, requiring configuration and selection of each code family to be read.
A UTO CONFIGURATION
The following codes do not require reading the Enter and Exit configuration codes.
In auto-configuration mode the reader enters a particular state, during which it reads, recognizes and saves all information received from the decoding of an existing code (with the exception of MSI, Code 49 and Code 16k code types). In this way, the code families will be automatically configured.
It is possible to configure up to 10 code types, whose length is variable and check digit ignored.
If reading different codes belonging to the same family, information about the last code will overwrite the information about the previous one.
Follow the given procedure to auto-configure the desired code families:
CAUTION
If no code is read during the auto-configuration procedure (step d ), the configuration will be empty and therefore the reader will be unable to read codes. c Read the following code to enter the auto-configuration mode: auto-configuration
Ì#+AUTOWÎ
d Read an existing code belonging to the code families that you need to configure. e Read the following code to save the configuration automatically and return to the reader's normal functioning: save auto-configuration
Ì$-?Î
If you need to change the configuration, repeat the auto-configuration procedure, follow the manual configuration by setting the parameters for each single code family or read the "Restore
Default" code on page 165. Be careful that in the latter case all reader parameters will be
restored.
94
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
DISABLE ALL CODE FAMILIES
ÌAZ0ÃÎ
The reader allows up to 10 code selections. This does not limit the number of
CODES enabled to 10, as it depends on the code family.
NOTE
SINGLE
SELECTIONS =
Example
• ONE combination code from the EAN family
• ONE code from the 2/5 family
5 code selections: 1. 2/5 Interleaved
2. 2/5 Industrial
3. Code 128 + EAN 128
4. Code 39 Full ASCII + Code 32
5. UPC A/UPC E
6. etc.
In this section all SINGLE code selections are underlined and in bold.
95
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
EAN/UPC F AMILY disable the family
ÌAA0MÎ
c Read the desired family code
Note:
Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable another selection, first disable the family.
EAN 8/EAN 13/UPC A/UPC E with and without ADD ON
ÌAA8eÎ
WITHOUT ADD ON
EAN 8/EAN 13/UPC A/UPC E
ÌAA1PÎ
EAN 8/EAN 13
ÌAA3VÎ
UPC A/UPC E
ÌAA4YÎ
EAN 8/EAN 13/UPC A/UPC E
ÌAA5\Î
WITH ADD ON 2 AND 5
EAN 8/EAN 13
ÌAA6_Î
UPC A/UPC E
ÌAA7bÎ
96
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
WITH ADD ON 2 ONLY
EAN 8/EAN 13
ÌAAK7Î
UPC A/UPC E
ÌAAM=Î
WITH ADD ON 5 ONLY
EAN 8/EAN 13
ÌAAL:Î
UPC A/UPC E
ÌAAN@Î
WITH AND WITHOUT ADD ON
EAN/UPC with and without ADD ON no
Autodiscrimination
ÌAA8Ad03Î
EAN/UPC Autodiscrimination ADD ON by
Prefix
ÌAA8Ad19Î
By setting the EAN/UPC Autodiscrimination ADD ON by Prefix, the desired prefixes must be selected by reading the corresponding codes given in the following section, since no prefix is configured by default.
97
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
SELECT EAN/UPC PREFIXES
NOTE
When scanning the following codes, bar codes starting with the selected prefixes will be read and transmitted only if the ADD ON is present. If no ADD
ON is found, the bar code will not be read. Bar codes starting with different characters are read regardless of ADD ON presence and transmitted always without ADD ON.
Cancel All Selections
ÌET0wÎ
OR select one or more of the following prefixes:
378/379
ÌET1378ET2379PÎ
434/439
ÌET3434ET4439ÉÎ
414/419
ÌET5414ET6419}Î
977
ÌET7977QÎ
978
ÌET8978ZÎ
979
ÌET9979cÎ
The commands above are not mutually exclusive. They can be used to configure more than one set of prefixes simultaneously.
98
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
Example:
The following string allows reading and transmitting with ADD ON all EAN/UPC starting with the
434/439, 977 and 978 prefixes:
1. EAN/UPC Autodiscrimination ADD ON by Prefix.
2. 434/439: enables reading and transmission with ADD ON of all EAN/UPC bar codes starting with 434/439 prefixes.
3. 977: enables reading and transmission with ADD ON of all EAN/UPC bar codes starting with 977 prefix.
4. 978: enables reading and transmission with ADD ON of all EAN/UPC bar codes starting with 978 prefix.
EAN/UPC Autodiscrimination ADD ON by
Prefix
434/439
ÌAA8Ad19Î
+
ÌET3434ET4439ÉÎ
+
977 978
+
ÌET7977QÎ
+
ÌET8978ZÎ
To clear the current prefix selections:
1. Cancel all Selections
Cancel All Selections
ÌET0wÎ
99
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
EAN/UPC CHECK DIGIT TX SELECTIONS
For each code type in this family you can choose to transmit the check digit or not
CHECK DIGIT TRANSMISSION
EAN 8
NO CHECK DIGIT
TRANSMISSION
ÌAAG1oÎ
EAN 8
ÌAAG0kÎ
EAN 13
ÌAAH1rÎ
EAN 13
ÌAAH0nÎ
UPC A
ÌAAI1uÎ
UPC A
ÌAAI0qÎ
UPC E
ÌAAJ1xÎ
UPC E
ÌAAJ0tÎ
100
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
UPC E to UPC A conversion
ÌAAAÄÎ
UPC A to EAN 13 conversion
ÌAACÊÎ
CONVERSION OPTIONS
UPC E to EAN 13 conversion
ÌAABÇÎ
EAN 8 to EAN 13 conversion
ÌAAD"Î
Enable only ISBN conversion
ÌAP1nÎ
Enable only ISSN conversion
ÌAP2qÎ
Enable both ISBN and ISSN conversion
ÌAP3tÎ
Disable both ISBN and ISSN conversion
ÌAP0kÎ
101
Enter Configuration
Ì$+;Î
c Read the desired family code
Interleaved 2/5
ÌAC1TÎ
Normal 2/5 (5 Bars)
ÌAC2WÎ
CODE SELECTION
2/5 F AMILY disable the family
ÌAC0QÎ
Exit and Save Configuration
Ì$-?Î
d Read a check digit selection
CHECK DIGIT TABLE no check digit control
Ì12Î
Industrial 2/5 (IATA)
ÌAC3ZÎ
Matrix 2/5 (3 Bars)
ÌAC4]Î
The pharmaceutical code below is part of the 2/5 family but has no check digit or code length selections.
Code CIP/HR
ÌAC5`Î
French pharmaceutical code
check digit control and transmission
Ì23Î
check digit control without transmission
Ì34Î
e Read 4 numbers for the code length where:
− First 2 digits = minimum code length.
− Second 2 digits = maximum code length.
The maximum code length is
99 characters.
The minimum code length must always be less than or equal to the maximum.
Examples:
0199 = variable from 1 to 99 digits in the code.
1010 = 10 digit code length only.
102
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
C ODE 39 F AMILY disables the family
ÌAB0OÎ
c Read the desired family code
Standard Code 39
ÌAB1RÎ
d Read a check digit selection
CHECK DIGIT TABLE
no check digit control
Ì12Î
Full ASCII Code 39
ÌAB2UÎ
check digit control and transmission
Ì23Î
check digit control without transmission
Ì34Î
The pharmaceutical codes below are part of the Code 39 family but have no check digit selections.
Code CIP39
ÌAB3XÎ
French pharmaceutical code
Code 32
ÌAB4[Î
Italian pharmaceutical code
CODE LENGTH (optional)
The code length selection is valid for the entire Code 39 family
Read the code + 4 numbers for the code length where:
First 2 digits = minimum code length.
Second 2 digits = maximum code length. set code length
ÌAB*=Î
The maximum code length is 99 characters.
The minimum code length must always be less than or equal to the maximum.
Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.
103
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
C ODE 128 F AMILY c Read the desired family code
Code 128
ÌAI11=Î
control without transmission of check digit
EAN 128
ÌAI21@Î
control without transmission of check digit disable the family
ÌAI0]Î
ISBT 128
ÌAI31CÎ
enabling ISBT 128 automatically disables Puzzle Solver™.
Transmit GS Before Code
Code EAN 128 uses the ASCII <GS> character to separate a variable length code field from the next code field. This character can also be transmitted before the code.
disable
ÌEQ0qÎ
enable
ÌEQ1tÎ
If the <GS> character has been modified in the Character Replacement parameter, the new character is affected by this command.
CODE LENGTH (optional)
The code length selection is valid for the entire Code 128 family and is calculated on the output string.
Read the code + 4 numbers for the code length where: set code length
First 2 digits = minimum code length.
ÌAILJÎ
Second 2 digits = maximum code length.
The maximum code length is 99 characters.
The minimum code length must always be less than or equal to the maximum.
Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.
104
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
C ODE 93
disable the code
ÌAK0aÎ
Code 93
ÌAK1dÎ
control without transmission of check digit
C ODABAR F AMILY
disable the family
ÌAD0SÎ
c Read the desired equality control code d Read a start/stop transmission selection
START/STOP CHARACTER
TRANSMISSION
Standard Codabar
ÌAD113Î
no start/stop character equality control no transmission
Ì12Î
Standard Codabar
ÌAD127Î
start/stop character equality control transmission
Ì23Î
105
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
The Codabar ABC code below uses a fixed start/stop character transmission selection.
Codabar ABC
ÌAD212)Î
no start/stop character equality control but transmission.
Codabar ABC Forced Concatenation enable Codabar ABC with forced concatenation
ÌAD2321Î
non start/stop character equality control but transmission
CODE LENGTH (optional)
The code length selection is valid for the entire Codabar family
Read the code + 4 numbers for the code length where:
First 2 digits = minimum code length.
Second 2 digits = maximum code length. set code length
ÌAD*AÎ
The maximum code length is 99 characters.
The minimum code length must always be less than or equal to the maximum.
Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.
START/STOP CHARACTER CASE IN TRANSMISSION
The start/stop character case selections below are valid for the entire Codabar family: transmit start/stop characters in lower case
ÌADA0_Î
transmit start/stop characters in upper case
ÌADA1cÎ
106
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
MSI
disable the family
ÌAE0UÎ
Enable the code by selecting one of the check digit selections. no check digit control
ÌAE1XÎ
MOD10 check digit control no check digit transmission
ÌAE2[Î
MOD10 check digit control check digit transmission
ÌAE3^Î
MOD11 - MOD10 check digit control no check digit transmission
ÌAE4aÎ
MOD11 - MOD10 check digit control check digit transmission
ÌAE5dÎ
MOD10 - MOD10 check digit control no check digit transmission
ÌAE6gÎ
MOD10 - MOD10 check digit control check digit transmission
ÌAE7jÎ
107
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
C ODE 11
disable the family
ÌAG0YÎ
Enable the code by selecting one of the check digit selections.
Type C check digit control check digit transmitted
ÌAG21<Î
Type K check digit control check digit transmitted
ÌAG31?Î
no check digit control
ÌAG1\Î
Type C check digit control check digit not transmitted
ÌAG22@Î
Type K check digit control check digit not transmitted
ÌAG32CÎ
Type C and Type K check digit control check digits transmitted
ÌAG41BÎ
Type C and Type K check digit control check digits not transmitted
ÌAG42FÎ
108
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
C ODE 16K
disable the code
ÌAJ0_Î
Code 16K
ÌAJ1bÎ
To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
C ODE 49
disable the code
ÌAM0eÎ
Code 49
ÌAM1hÎ
To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
109
Enter Configuration
Ì$+;Î
CODE SELECTION
Exit and Save Configuration
Ì$-?Î
GS1 D ATA B AR ™ C ODES
ÌAQ0mÎ
DISABLE CODE disable GS1 DataBar Expanded Linear and
Stacked
ÌAQ10IÎ
disable the family
ENABLE CODE enable GS1 DataBar Expanded Linear and
Stacked
ÌAQ11MÎ
disable GS1 DataBar Limited
ÌAQ20LÎ
disable GS1 DataBar 14 Linear and Stacked
ÌAQ30OÎ
enable GS1 DataBar Limited
ÌAQ21PÎ
enable GS1 DataBar 14 Linear and Stacked
ÌAQ31SÎ
To read stacked codes, simply move the reader over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
110
ADVANCED FORMATTING
NOT FOR PEN INTERFACES
~
~
C ONCATENATION
A DVANCED F ORMATTING
~
~
NOTE
Please follow the setup procedure carefully for these parameters.
The Advanced Formatting parameters may not be compatible with the
IBM USB POS interface selection.
NOTE
1.
Read the Enter Configuration code ONCE, available at the top of page.
2.
Read configuration codes precisely following the numbered procedure given.
= Read the code and follow the procedure given
= Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of page.
111
Enter Configuration
Ì$+;Î
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
C ONCATENATION
disable
ÌEI0aÎ
enable
ÌEI1dÎ
Permits the concatenation of two codes defined by code type and length. It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires.
The order of transmission is CODE 1-CODE 2.
Define Concatenation
1 Code 1 code ID
ÌEK0eÎ
Read the code type from the Code Identifier Table beginning in Appendix
code length
ÌEL0gÎ
Read a number in the range 01-99 from the Hex/Numeric Table.
112
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
2 Code 2 code ID
ÌEK1hÎ
Read the code type from the Code Identifier Table beginning in Appendix
code length
ÌEL1jÎ
Read a number in the range 01-99 from the Hex/Numeric Table.
Concatenation Result Code ID 3 use code 1 ID
ÌEN0kÎ
use code 2 ID
ÌEN1nÎ
Since you can concatenate codes from different families, you must select the Code ID character of the resulting code. The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection (Manufacturer, AIM, or Custom).
Concatenation Timeout 4 timeout
ÌEJ3Î
Read two numbers in the range 00 to 99
00= no timeout
01-99 = timeout from 1 to 99 seconds
Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection. (HHDII)
113
5
ADVANCED FORMATTING
Transmission after Timeout no code transmitted after timeout
ÌEM0iÎ
Exit and Save Configuration
Ì$-?Î
only code 1 transmitted
(if read) after timeout
ÌEM1lÎ
only code 2 transmitted
(if read) after timeout
ÌEM2oÎ
either code 1 or code 2 transmitted after timeout
ÌEM3rÎ
114
ADVANCED FORMATTING
A DVANCED F ORMATTING
Advanced formatting has been designed to offer you complete flexibility in changing the format of bar code data before transmitting it to the host system. This formatting will be performed when the bar code data meets certain criteria, which you will define in the following procedure.
Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure:
YES
Read the Enter
Configuration Command
Step 1
Begin Format Definition
1, 2, 3, or 4
Steps 2 - 4
Define Match Code Conditions
Step 5
Divide Code into Fields
Step 6
Define Code Fields
Steps 7 - 8
Add up to 2 Additional Fields
Step 9
Define Field Transmission
Step 10
Apply or Not
Standard Message Formatting
Step 11
End Format Definition
1, 2, 3, or 4
Define another?
NO
Enable Advanced Formats
1, 2, 3, 4
Define No Match Result
Read the Exit and Save
Configuration Command
115
Enter Configuration
Ì$+;Î
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
1 Begin Format Definition begin Format 1 definition
ÌHA0TÎ
begin Format 2 definition
ÌHA1WÎ
begin Format 3 definition
ÌHA2ZÎ
begin Format 4 definition
ÌHA3]Î
match code type
ÌHB&Î
Read the above code + the code type to match from the Code Identifier Table in Appendix
OR any code type
ÌHB0VÎ
match code length
ÌHC(Î
Read the above code + two numbers in the range 01 to 99 for the exact code length.
OR any code length
ÌHC001Î
116
ADVANCED FORMATTING
Match with Predefined Characters
Exit and Save Configuration
Ì$-?Î
4 no match
ÌHD0HE00ÄÎ
OR match with 1 character
ÌHD1]Î
match with a 2-character string
ÌHD2`Î
match with a 3-character string
ÌHD3cÎ
match with a 4-character string
ÌHD4fÎ
After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 00-FE.
Example:
Match code with the 2-character predefined string = "@@".
Match with a 2-character string
Read + 40 + 40
AND position of first character in predefined string
ÌHE,Î
Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found.
Read 00 if the match string can be found in any character position.
See section 5.8.1 for details.
117
ADVANCED FORMATTING
5 Divide Code into Fields divide code into fields
ÌHF.Î
Read one number in the range 1 to 5 to divide the code into fields.
Exit and Save Configuration
Ì$-?Î
6 Define Code Fields define code fields
Each code field length can be set by either:
a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field.
OR BY
b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match.
OR BY
c) specifying a specific character length up to the maximum of 99 characters.
OR BY
d) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will not be transmitted.
118
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
DEFINE FIELD 1 BY:
EITHER field separator a)
ÌHG0`Î
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator
Ì01Î
include separator
Ì12Î
OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE.
OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length.
OR this is the last field (variable length)
ÌHG2fÎ
d)
AND
Field 1 Terminators no field terminators
ÌHH0bÎ
1 field terminator 2 field terminators
ÌHH1eÎ ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special
119
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
DEFINE FIELD 2 BY:
EITHER field separator a)
ÌHG0`Î
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator
Ì01Î
include separator
Ì12Î
OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE.
OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length.
OR this is the last field (variable length)
ÌHG2fÎ
d)
AND
Field 2 Terminators no field terminators
ÌHH0bÎ
1 field terminator 2 field terminators
ÌHH1eÎ ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special
120
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
DEFINE FIELD 3 BY:
EITHER field separator a)
ÌHG0`Î
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator
Ì01Î
include separator
Ì12Î
OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE.
OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length.
OR this is the last field (variable length)
ÌHG2fÎ
d)
AND
Field 3 Terminators no field terminators
ÌHH0bÎ
1 field terminator 2 field terminators
ÌHH1eÎ ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special
121
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
DEFINE FIELD 4 BY:
EITHER field separator a)
ÌHG0`Î
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator
Ì01Î
include separator
Ì12Î
OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE.
OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length.
OR this is the last field (variable length)
ÌHG2fÎ
d)
AND
Field 4 Terminators no field terminators
ÌHH0bÎ
1 field terminator 2 field terminators
ÌHH1eÎ ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special
122
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
DEFINE FIELD 5 BY:
EITHER field separator a)
ÌHG0`Î
Read the field separator character from the HEX table. Range of characters = 00-FE. discard separator
Ì01Î
include separator
Ì12Î
OR match character b)
ÌHG3iÎ
Read the match character from the HEX table. Range of characters = 00-FE.
OR field length c)
ÌHG1cÎ
Read two numbers in the range 01 to 99 to define the field length.
OR this is the last field (variable length)
ÌHG2fÎ
d)
AND
Field 5 Terminators no field terminators
ÌHH0bÎ
1 field terminator 2 field terminators
ÌHH1eÎ ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 00-FE. For Wedge and USB-KBD interface, it is also possible to read the Special
123
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
First Additional Fixed Field 7 no fixed field
ÌHI0dÎ
1 character fixed field
ÌHI1gÎ
2 character fixed field
ÌHI2jÎ
3 character fixed field
ÌHI3mÎ
4 character fixed field
ÌHI4pÎ
5 character fixed field
ÌHI5sÎ
6 character fixed field
ÌHI6vÎ
After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 00-FE. For Wedge and USB-KBD interface, it is also
possible to read the Special Key(s) on page 75.
Example:
4 Character Fixed Field
+ 4D + 41 + 49 + 4E = MAIN
124
8
ADVANCED FORMATTING
Second Additional Fixed Field
Exit and Save Configuration
Ì$-?Î
no fixed field
ÌHJ0fÎ
1 character fixed field
ÌHJ1iÎ
2 character fixed field
ÌHJ2lÎ
3 character fixed field
ÌHJ3oÎ
4 character fixed field
ÌHJ4rÎ
5 character fixed field
ÌHJ5uÎ
6 character fixed field
ÌHJ6xÎ
After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 00-FE. For Wedge and USB-KBD interface, it is also
possible to read the Special Key(s) on page 75.
Example:
3 Character Fixed Field
+ 53 + 45 + 54 = SET
125
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
9 Field Transmission number of fields to transmit
ÌHK8Î
Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted.
Field Order Transmission
Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1
Ì12Î
field 2
Ì23Î
field 3
Ì34Î
field 4
Ì45Î
field 5
Ì56Î
additional field 1
Ì67Î
additional field 2
Ì78Î
Example:
The bar code is divided into 3 defined fields plus 1 additional fixed field.
Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2.
Number of Fields to Transmit Field 2 Additional Field 1 Field 1
+ 4 + + + +
Field 2
126
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
10 Standard Formatting do not apply standard formatting
ÌHL0jÎ
apply standard formatting
ÌHL1mÎ
POWERSCAN ® D8330: After performing Advanced Formatting on the bar code read, Standard
Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted.
POWERSCAN ® M8300: After performing Advanced Formatting on the bar code read, Standard
Formatting (Code Length, Code ID) can be applied to the message to be transmitted.
End Format Definition 11 end Format 1 definition
ÌHM0lÎ
end Format 2 definition
ÌHM1oÎ
end Format 3 definition
ÌHM2rÎ
end Format 4 definition
ÌHM3uÎ
127
Enter Configuration
Ì$+;Î
ADVANCED FORMATTING enable
ÌHN11NÎ
enable
ÌHN21QÎ
enable
ÌHN31TÎ
enable
ÌHN41WÎ
Enable Advanced Format
no Advanced Formats enabled
ÌHN0nÎ
Advanced Format 1
Advanced Format 2
Advanced Format 3
Advanced Format 4
Exit and Save Configuration
Ì$-?Î
disable
ÌHN10JÎ
disable
ÌHN20MÎ
disable
ÌHN30PÎ
disable
ÌHN40SÎ
128
Enter Configuration
Ì$+;Î
ADVANCED FORMATTING
Exit and Save Configuration
Ì$-?Î
No Match Result clear data - no transmission
ÌHO0pÎ
transmit data using standard format
ÌHO1sÎ
This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match).
• Codes not matching can be ignored, cleared from memory and not transmitted.
• Codes not matching can be transmitted using the Standard formatting (Headers, Code
Length, Code ID, Terminators).
129
RADIO PARAMETERS
PowerScan
®
M8300 Series readers only
~
~
~
~
~
~
~
R ADIO P ROTOCOL T IMEOUT
R ADIO RX T IMEOUT
P OWER -O FF T IMEOUT
T RANSMISSION M ODE
B
EEPER
C
ONTROL FOR
R
ADIO
R
ESPONSE
S INGLE S TORE
B ATCH M ODE
~
~
~
~
~
~
~
~ F IND M E ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
130
Enter Configuration
Ì$+;Î
disable
RADIO PARAMETERS
R ADIO P ROTOCOL T IMEOUT radio protocol timeout
ÌRH<Î
Exit and Save Configuration
Ì$-?Î
Read a number from the table where:
02-19 = timeout from 2 to 19 seconds
2 seconds
See section 5.9.1 for details.
R ADIO RX T IMEOUT radio RX timeout always on
Specify timeout
Read 2 numbers in the range 05-99:
05-99 = Radio RX timeout range from 05 to 99 seconds.
NOTE
This functionality is available only for stand-alone layout.
See section 5.9.2 for details.
131
Enter Configuration
Ì$+;Î
RADIO PARAMETERS
P OWER -O FF T IMEOUT power-off timeout
ÌRPLÎ
Exit and Save Configuration
Ì$-?Î
Read 2 numbers in the range 00-99:
00 = Power-off disabled; reader always ready
01-99 = corresponds to a max. 99 hour delay before power-off.
power-off after 4 hours.
T RANSMISSION M ODE
One Way
ÌRI0nÎ
Two-ways
ÌRI1qÎ
See section 5.9.4 for details.
132
Enter Configuration
Ì$+;Î
RADIO PARAMETERS
Exit and Save Configuration
Ì$-?Î
B EEPER C ONTROL FOR R ADIO R ESPONSE
normal
ÌBF0XÎ
only good reception
ÌBF2^Î
only good decode
ÌBF1[Î
off
ÌBF3aÎ
See section 5.9.5 for details.
133
Enter Configuration
Ì$+;Î
disable
ÌRO0zÎ
RADIO PARAMETERS
S INGLE S TORE two attempts
ÌRO2ÄÎ
four attempts
ÌRO4ÊÎ
six attempts
ÌRO6%Î
Exit and Save Configuration
Ì$-?Î
one attempt
ÌRO1}Î
three attempts
ÌRO3ÇÎ
five attempts
ÌRO5"Î
seven attempts
ÌRO7(Î
eight attempts
ÌRO8+Î
nine attempts
ÌRO9.Î
134
Enter Configuration
Ì$+;Î
RADIO PARAMETERS
Exit and Save Configuration
Ì$-?Î
disable batch
ÌBZ0ÄÎ
enable automatic batch
ÌBZ2ÊÎ
B ATCH M ODE enable normal batch
ÌBZ1ÇÎ
See section 5.9.7 for details.
The following batch management parameters are complete commands and do not
require reading the Enter and Exit configuration codes. start normal batch transmission
Ì#+BFlush]Î
#+BFlush delete batch data
Ì#+BReset\Î
#+BReset
F IND M E disable
ÌBk0;Î
enable
ÌBk1>Î
See section 5.9.8 for details.
135
DISPLAY PARAMETERS
PowerScan
®
M8300 Series readers only
~
~
~
~
~
D ATE AND T IME
C ONTRAST
F ONT S IZE
B ACKLIGHT
D ISPLAY O FF T IMEOUT
~
~
~
~
~
~ D ISPLAY M ODE ~
~ K EYPAD ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
136
Enter Configuration
Ì$+;Î
DISPLAY PARAMETERS
D ATE AND T IME
Read 6 numbers for DDMMYY
ÌIA%Î
Exit and Save Configuration
Ì$-?Î
set time
ÌIB'Î
Read 4 numbers for HHMM
C ONTRAST lighter
ÌIC0YÎ
darker
Read the code until the desired contrast is reached.
ÌIC1\Î
small
ÌID0[Î
large
ÌID2aÎ
F ONT S IZE medium
ÌID1^Î
B ACKLIGHT
backlight off
ÌIE0]Î
backlight on
ÌIE1`Î
137
Enter Configuration
Ì$+;Î
DISPLAY PARAMETERS
D ISPLAY -O FF T IMEOUT timeout
ÌIF/Î
Read 2 numbers in the range 00-99:
00 = disables display timeout (always on)
01 to 99 = timeout from 1 to 99 seconds.
display-off after 8 seconds.
delay disabled
D ISPLAY M ODE normal
ÌIG0aÎ
Exit and Save Configuration
Ì$-?Î
clear display after decode
ÌIG2gÎ
See section 5.10.1 for details.
local echo
ÌIG1dÎ
138
Enter Configuration
Ì$+;Î
DISPLAY PARAMETERS
Exit and Save Configuration
Ì$-?Î
K EYPAD disable reader keypad
ÌIK0iÎ
enable reader keypad and select characters
ÌIK1lÎ
Read 3 HEX characters in the range 00-FE, corresponding to the left, center and right keys respectively.
FF = KeyID disabled
left = '<'
center = '='
right = '>'
139
POWERSCAN ® D8330/M8300
5 REFERENCES
5.1 RS-232 PARAMETERS
5.1.1 Handshaking
Hardware handshaking: (RTS/CTS)
The RTS line is activated by the decoder before transmitting a character.
Transmission is possible only if the CTS line (controlled by the Host) is active.
Signals at
EIA levels
RTS
TX
Transmitted data Transmitted data
CTS Host busy
RTS/CTS handshaking
Software handshaking: (XON/XOFF)
During transmission, if the Host sends the XOFF character (13 Hex), the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character (11 Hex) is received.
Transmitted data Transmitted data
TX
RX
XOFF
Host busy
XON
Host ready
XON/XOFF handshaking
140
REFERENCES
5.1.2 ACK/NACK Protocol
PowerScan
®
D8330 Readers
This parameter sets a transmission protocol in which the Host responds to the reader after every code transmitted. The Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. data
PowerScan ® D8330 cable
Host
ACK or NACK
ACK/NACK enabled
If the reader does not receive an ACK or NACK, transmission is ended after the
RX Timeout (see section 5.1.4).
When ACK/NACK protocol is enabled, FIFO must be disabled manually, see section
PowerScan ® M8300 Readers
The transmission protocol takes place between reader, cradle and Host. The reader passes its data (code read) to the cradle, which sends it to the Host. The management of responses (from Host or cradle) depends on the Transmission Mode
In the following descriptions the completed transmission is indicated by the Beeper
Control for Radio Response parameter with its default setting to Normal, see section
When ACK/NACK is disabled (in One-Way tx mode), there is no control from cradle to Host transmission, the reader responds with the good reception tone.
Transmission Mode = One-Way data data
PowerScan ®
M8300 good RX beep
BC-80X0 cable
Host
ACK/NACK disabled
141
POWERSCAN ® D8330/M8300
Transmission Mode = Two-Ways data data
PowerScan
M8300
® BC-80X0 cable
NACK
Host good RX beep data
ACK
ACK/NACK enabled
When ACK/NACK is enabled (in Two-Way tx mode), the Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting re-transmission, in the case of bad reception. Only after the ACK character is received by the BC-80X0 does the reader respond with the good reception tone.
If the BC-80X0 does not receive an ACK or NACK, transmission is ended after the
RX Timeout, see section 5.1.4. See also Radio Protocol Timeout, section 5.9.1.
When ACK/NACK protocol is enabled, FIFO must be disabled manually, see section
5.1.3 FIFO
PowerScan
®
D8330 Readers
This parameter determines whether data (bar codes) are buffered on a First In First
Out basis allowing faster data collection in certain cases for example when using slow baud rates and/or hardware handshaking.
If the FIFO buffering is enabled, codes are collected and sent out on the serial line in the order of acquisition. About 800 characters can be collected (buffer full), after which the reader signals an error and discards any further codes until the transmission is restored.
If the FIFO buffering is disabled, each code must be transmitted before another one can be read.
PowerScan
®
M8300 Readers
If enabled, the BC-80X0 collects all messages sent by PowerScan
®
M8300 and sends them in order of acquisition to the connected Host.
If disabled, PowerScan
®
M8300 blocks message transmission until the BC-80X0 has completed transmission towards the Host.
142
REFERENCES
5.1.4 RX Timeout
When the RS-232 interface is selected, the Host can be used to configure the device
by sending it command strings (see Appendix A).
This parameter can be used to automatically end data reception from the Host after the specified period of time.
If no character is received from the Host, after the timeout expires, any incomplete string (any string not terminated by <CR>) is flushed from the device buffer.
5.2 PEN PARAMETERS
5.2.1 Minimum Output Pulse
This parameter sets the duration of the output pulse corresponding to the narrowest element in the bar code. In this way the code resolution is controlled by the signal sent to the decoder, independently of the physical resolution of the code read.
The shortest pulse (200 μs) corresponds to a high-resolution code emulation and therefore a shorter transfer speed to the decoder (for decoders able to work on high resolution codes). Likewise, longer pulses correspond to low-resolution code emulation and therefore a longer transfer time to the decoder.
5.2.2 Conversion to Code 39 and Code 128
PowerScan
®
D8330 Series Readers
When using these readers it is possible to convert all codes to Code 39. By disabling this option the decoded codes will be transmitted in their original format, except for the following codes, which are ALWAYS converted into Code 39 format:
MSI, Code 11, Code 16K, Code 49, GS1 DataBar™.
PowerScan ® M8300 Series Readers
When using these readers it is possible to choose between converting the decoded codes into either Code 39 format or Code 128 format. It is not possible to disable conversion.
143
POWERSCAN ® D8330/M8300
5.2.3 Overflow
This parameter generates a white space before the first bar and after the last bar of the code. The selections are as follows: narrow = space 10 times the minimum output pulse. medium = space 20 times the minimum output pulse. wide = space 30 times the minimum output pulse.
5.2.4 Output and Idle Levels
The following state diagrams describe the different output and idle level combinations for Pen emulation: idle bar
OUTPUT: Normal black space
IDLE: Normal white barcode output bar
OUTPUT: Normal black idle space
IDLE: Inverted white barcode output space
OUTPUT: Inverted
IDLE: Normal idle bar barcode output white black
OUTPUT: Inverted
IDLE: Inverted idle space bar barcode output white black
Output and Idle Levels
144
REFERENCES
5.2.5 Inter-Block Delay
For the PEN Emulation interface, data are sent to the Host in fixed size blocks of 20 characters each. The inter-block delay parameter allows setting a delay between each block sent to the Host.
5.3 NETWORK PARAMETERS
5.3.1 Slave Address Range First/Last
These parameters define the valid addresses for the Slave cradles on the network.
Valid values are in the range 0 to 1999. However, the maximum number of cradles in a single network is 16, (including the Master if present). All cradles in the system must have different addresses.
To reduce system boot time, it is recommended to number the Slaves consecutively, while it is not necessary that the Master cradle address is contained in the range.
The network addresses correspond to the radio addresses, see section 4.7.
At system power-up, the Master searches for and initializes all the Slaves found in the valid address range. During this phase the yellow LED on the Master cradle blinks. The time to complete the start up procedure varies depending on the complexity of the network but is typically between a few seconds to a few minutes.
Start up cannot be interrupted. At the end of this procedure the system will be operative and can collect data from all devices.
CAUTION
All Slaves must be powered up either before or together with the
Master. Slaves successively powered will not be recognized by the system even if their address is in the specified range.
5.3.2 Network Warning Message
The Master cradle can transmit warning messages to the Host regarding some network errors.
/*Slave xxxx not responding*/: when the Master can no longer communicate with the specified Slave previously identified at start up.
/*Frame out of sequence for terminal xxxx*/: if a reader is sending data packets out of sequence. This can happen if there are transmission problems on the network (either connection or communication), or if the reader has correctly transmitted data to a device not on the network (reader configuration error).
145
POWERSCAN ® D8330/M8300
The message is sent in the following format:
"Message" CR LF
5.3.3 Reception Warning Message
The Master cradle can transmit warning messages to the Host regarding wrong reception of data. Example:
/*Two-Ways Out of Sequence!(.....)*/
This message is transmitted to the Host by the Master cradle when the
Master cradle receives a closing string from the Host for a Two-way tx communication, but this was either not open or already closed, therefore the
data will be lost. See section 5.9.4.
5.3.4 Master Header/Terminator Selection
In addition to the standard header/terminator selection, the Master cradle can add its own header/terminator to the entire message sent to the Host.
In the STAR-System™ network headers and terminators for all RF Devices are disabled by default.
The Master header and terminator default values are as follows depending on the interface selection towards the Host:
RS-232: no header, terminator CR-LF
WEDGE: no header, terminator ENTER
.
5.4 DATA FORMAT
For an overview of Message Formatting see Chapter 6.
5.4.1 Header/Terminator Selection
The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection:
RS-232: no header, terminator CR-LF
WEDGE: no header, terminator ENTER
146
REFERENCES
These default values are always restored through the reading of RS-232 or WEDGE
interface selection code, see chapter 2.
For the WEDGE interface, the following extended keyboard values can also be configured:
EXTENDED KEYBOARD TO HEX CONVERSION TABLE
IBM AT
IBM 3153
APPLE ADB
IBM XT IBM 31xx, 32xx,
34xx, 37xx
Wyse
Digital
91
92
93
94
95
8C
8D
8E
8F
90
87
88
89
8A
8B
83
84
85
86
96
97
98
99
9A
9B
TAB TAB TAB TAB
F1 F1 F1 F1
F2 F2 F2 F2
F3 F3 F3 F3
F4 F4 F4 F4
F5 F5 F5 F5
F6 F6 F6 F6
F7 F7 F7 F7
F8 F8 F8 F8
F9 F9 F9 F9
F10 F10 F10 F10
F11 ESC F11 F11
F12 BACKSPACE F12 F12
HOME HOME ENTER F13
PG UP
PG DOWN
↑
↓
PG UP
PG DOWN
↑
↓
INSERT
DELETE
FIELD -
FIELD +
F15
F16
UP
DOWN
←
→
←
→
ENTER (Paddle) LEFT
PRINT RIGHT
ESC ESC ESC
CTRL (Right) CTRL (Right) CTRL (Right)
Euro Space Space Space
For all devices using IBM AT (compatible) Wedge or USB-KBD interfaces, all values from 9C to
FE send the relative simulated keypress when available or else the relative ALT-Mode
sequence. See the Hex to Character Conversion Table in Appendix C
.
For all devices using other Wedge interfaces, all values from 9C to FE send the Space character.
147
Enter Configuration Exit and Save Configuration
Ì$+;Î
5.4.2 Define Special Key Sequence
Ì$-?Î
The Special Key(s) for Wedge IBM AT-PS/2 and USB-KBD interface users can be associated with a sequence of keyboard keys that otherwise could not be selected, i.e. ALT + F6, SHIFT + F1. These Special Keys can be used for:
- Headers/Terminators
- Custom Code ID
- Advanced Formatting – Define Field
- Advanced Formatting – Additional Fixed Field
Follow the procedure to define the desired Special Key sequence:
1. Read the Enter Configuration code above and select the Special Key to define
(one at a time):
Define Special Key 1
ÌFQ9C2>Î
Define Special Key 2
ÌFQ9D2BÎ
Define Special Key 3
ÌFQ9E2FÎ
Define Special Key 4
ÌFQ9F2JÎ
Define Special Key 5
ÌFQA02qÎ
148
REFERENCES
2. Read only one code to be associated with the special key sequence:
SHIFT
Ì12Î
OR
CTRL
Ì23Î
OR
ALT
Ì45Î
OR
CTRL + SHIFT
Ì34Î
OR
ALT + SHIFT
Ì56Î
OR
CTRL + ALT
Ì67Î
149
POWERSCAN® D8330/M8300
3. Select the character to be associated with the Special Key sequence by
reading the codes corresponding to the 3 character values from Appendix C.
Then, read the Exit and Save Configuration code above to complete the
Special Key sequence.
The character values having the S and A symbols require SHIFT or ALT keys or key combinations in step 2, in particular:
S
A
= the character is obtained in combination with SHIFT
= the character is obtained in combination with ALT
The following character values change according to the keyboard nationality.
KEYB
CHAR
ITA USA FR BE DE UK ES SW JP
!
"
#
$
%
&
'
(
)
*
+
,
016
S
01E S
052 A
025
S
02E
S
036 S
016
026
S
S
04A 03E 016
S
026 026 01E S
05D 05D 026
05B 05B 025
S
A
016 016 036 S
04E 052 025 025 05D
S
052 04E 05D 03D
S
03E
S
046
S
02E 02E 03E
04E 04E 046
S
S
05B S 03E 05B S 05B 03E S 05B S
05B 055
S
04A 055
S
05B 04E 04C
S
041 041 03A 03A 041 041 041 041 041
-
.
/
0
1
2
3
4
5
6
7
8
9
04A 04E 036 055 04A 04E 04A 04A 04E
049 049 041
S
03D
S
04A 049
S
045 045 045
S
049
S
04A 03D
S S
04A
016 016 016 S
01E 01E 01E
S
026 026 026
S
025 025 025
S
02E 02E 02E S
036 036 036
S
03D 03D 03D
S
03E 03E 03E S
046 046 046
S
150
REFERENCES
KEYB
CHAR c
ITA USA FR BE DE UK ES SW JP
:
;
<
=
>
?
@
[
\
]
^
_
049
S
049 049 049
S
041 S
04C 041 041 041
S 04C 041 S
061
045
S
041
S
061 061 061 041
055 055 04A 045
S
055
S
061 061 041
S
045
S
061 S
04E
04C
A
054
A
04A
S
054 02E
A
00E 05D 03E A
054
A
04C 00E A A 051
05B
A
05B 04E
A
055
S
04A
S
054
03E 055 04A
S
05B
A
S
054
S
055
S
A
05D
04A
S
’ (accent) - 00E A 05D S 00E 054 055 S 054 a 01C 01C 015 015 01C 01C 01C 01C 01C b 032 032 032 032 032 032 032 032 032
021 021 021 021 021 021 021 021 021 d 023 023 023 023 023 023 023 023 023 e 024 024 024 024 024 024 024 024 024 f 02B 02B 02B 02B 02B 02B 02B 02B 02B g 034 034 034 034 034 034 034 034 034 h 033 033 033 033 033 033 033 033 033 i 043 043 043 043 043 043 043 043 043 j 03B 03B 03B 03B 03B 03B 03B 03B 03B k 042 042 042 042 042 042 042 042 042 l 04B 04B 04B 04B 04B 04B 04B 04B 04B m 03A 03A 04C 04C 03A 03A 03A 03A 03A n 031 031 031 031 031 031 031 031 031 o 044 044 044 044 044 044 044 044 044 p 04D 04D 04D 04D 04D 04D 04D 04D 04D q 015 015 01C 01C 015 015 015 015 015 r 02D 02D 02D 02D 02D 02D 02D 02D 02D s 01B 01B 01B 01B 01B 01B 01B 01B 01B t 02C 02C 02C 02C 02C 02C 02C 02C 02C u 03C 03C 03C 03C 03C 03C 03C 03C 03C v 02A 02A 02A 02A 02A 02A 02A 02A 02A
151
POWERSCAN ® D8330/M8300
{
|
}
~ x y z
KEYB
CHAR w
ITA USA FR BE DE UK ES SW JP
01D 01D 01A 01A 01D 01D 01D 01D 01D
022 022 022 022 022 022 022 022 022
035 035 035 035 01A 035 035 035 035
01A 01A 01D 01D 035 01A 01A 01A 01A
- 054 S 046 054 S 052
00E
S
-
-
05B
00E
S
S
016 061
S
016
A
061
A
06A
045 05B
S
05D
04A 05D
S
- 05B
A
To use upper case letters, it is necessary to read one of the
SHIFT commands from step 2 before the value corresponding to the lower case letters.
NOTE
The following key values are common to all the keyboard nationalities.
KEY
KEYB
ITA USA FR BE DE UK ES SW JP
ENTER 05A 05A 05A 05A 05A 05A 05A 05A 05A
TAB 00D 00D 00D 00D 00D 00D 00D 00D 00D
F1 005 005 005 005 005 005 005 005 005
F2 006 006 006 006 006 006 006 006 006
F3 004 004 004 004 004 004 004 004 004
F4 00C 00C 00C 00C 00C 00C 00C 00C 00C
F5 003 003 003 003 003 003 003 003 003
F6 00B 00B 00B 00B 00B 00B 00B 00B 00B
F7 083 083 083 083 083 083 083 083 083
F8 00A 00A 00A 00A 00A 00A 00A 00A 00A
F9 001 001 001 001 001 001 001 001 001
F10 009 009 009 009 009 009 009 009 009
F11 078 078 078 078 078 078 078 078 078
F12 007 007 007 007 007 007 007 007 007
Home 26C 26C 26C 26C 26C 26C 26C 26C 26C
End 269 269 269 269 269 269 269 269 269
PG UP 27D 27D 27D 27D 27D 27D 27D 27D 27D
PG down 27A 27A 27A 27A 27A 27A 27A 27A 27A
152
REFERENCES
KEYB
CHAR
ITA USA FR BE DE UK ES SW JP
Up arrow 275 275 275 275 275 275 275 275 275
Down arrow 272 272 272 272 272 272 272 272 272
Left arrow 26B 26B 26B 26B 26B 26B 26B 26B 26B
Right arrow 274 274 274 274 274 274 274 274 274
Esc 076 076 076 076 076 076 076 076 076
Ctrl right
€
214 214 214 214 214 214 214 214 214
02E
A
SPACE 029 029 029 029 029 029
NOTE
If Caps Lock Auto-Recognition is disabled, it is necessary to verify that the keyboard caps lock status matches the reader one.
EXAMPLES
- Defining Special Key Sequences -
1. the following example allows defining Special Key 1 as SHIFT + F5: enter configuration define Special Key 1 SHIFT
Read
Ì$+;Î
+
ÌFQ9C2>Î
+
Ì12Î
+
codes from Appendix C corresponding
to the character value for F5 exit & save configuration
+ 003 +
Ì$-?Î
153
POWERSCAN ® D8330/M8300
2. the following example allows defining Special Key 2 as CTRL + S (upper case): enter configuration define Special Key 2 CTRL + SHIFT
Read
Ì$+;Î
+
ÌFQ9D2BÎ
+
Ì34Î
+
codes from Appendix C corresponding to
the character value for s (lower case) exit & save configuration
+
Read
01B +
Ì$-?Î
3. the following example allows defining Special Key 3 as Alt + F6: enter configuration define Special Key 3 ALT
Ì$+;Î
+
ÌFQ9E2FÎ
+
Ì45Î
+
codes from Appendix C corresponding
to the character value for F6 exit & save configuration
+ 00B +
Ì$-?Î
4. the following example allows defining Special Key 4 as Alt + Shift + F1: enter configuration define Special Key 4 ALT + SHIFT
Read
Ì$+;Î
+
ÌFQ9F2JÎ
+
Ì56Î
+
Read
codes from Appendix C corresponding
to the character value for F1 exit & save configuration
+ 005 +
Ì$-?Î
- Integrating Special Keys in Headers/Terminators -
1. the following example allows setting Special Key 1 (defined in example 1 above) as terminator: enter configuration one character terminator special key 1 exit & save configuration
Ì$+;Î
+
ÌEA111Î
+
Ì9CÄÎ
+
Ì$-?Î
154
REFERENCES
2. the following example allows setting Special Key 2 (defined in example 2 above) as header: enter configuration one character header special key 2 exit & save configuration
Read
Ì$+;Î
+
ÌEA01.Î
+
Ì9DÆÎ
+
Ì$-?Î
3. the following example allows setting Special Key 3 (defined in example 3 above) as header:
Read enter configuration one character header
Ì$+;Î
+
ÌEA01.Î
+ special key 3
Ì9EÈÎ
+ exit & save configuration
Ì$-?Î
4. the following example allows setting Special Key 4 (defined in example 4 above) and ENTER character as terminators: enter configuration two character terminator special key 4
ASCII characters corresponding to the
HEX value for character
ENTER
Read
Ì$+;Î
+
ÌEA125Î
+
Ì9FÊÎ
+ 83 + exit & save configuration
+
Ì$-?Î
5.4.3 Address Stamping
It is possible to include the reader address in the message sent to the host. The
Reader Address Stamping and the Cradle Address Stamping parameters consist of a
4-digit number in the range 0000 to 1999.
For message output format, refer to chapter 6.
5.4.4 Address Delimiter
The Address Delimiter allows a character to be included to separate the reader
Address stamping field from the next field in the message. Any character can be included in the hexadecimal range from 00 to FE.
For message output format, refer to chapter 6.
155
POWERSCAN ® D8330/M8300
5.4.5 Time Stamping Format
The Time Stamping parameter sets the format for hour and date information. It consists of 1 or 2 groups of numbers, each one made up of 6 decimal digits.
For example, setting the Hour/Minutes/Seconds/Month/Day/Year format, the information 17:03:16 on June 12, 2002 will be formatted as 170316061202.
5.4.6 Time Stamping Delimiter
The Time Stamping Delimiter allows a character to be included to separate the Time
Stamping field from the next field in the message. Any character can be included in the hexadecimal range from 00 to FE.
5.5 POWER SAVE
5.5.1 Sleep State
When using interfaces other than USB, this mode allows the μP in the reader to enter a “Sleep” state for minimum power consumption. For D-series readers, this command is only valid when hardware trigger type is selected.
Before entering Sleep mode, the following are verified:
• no commands coming from Host
• no data being transmitted to Host
• Enter Sleep Timeout ended (see section 5.5.2)
To exit Sleep mode press the trigger.
For M8300 series readers, sleep state is entered immediately after reading a code and is not configurable. To exit Sleep mode press the trigger.
When using the USB interface, this mode allows the device to manage Selective
Suspend conditions generated by the Host Operating System in which optimizing low power consumption (ex. Windows Stand-by). It is possible to exit the Suspend mode either from the Host (ex. moving the mouse during Stand-by) or through the bar code reader. The latter, called Remote Wakeup, makes the device wake up the Host restoring the communication. Remote Wakeup is possible by pressing the trigger.
156
REFERENCES
5.5.2 Enter Sleep Timeout
For readers that have the Sleep state enabled, this timeout determines when the reader will enter this state.
5.6 READING PARAMETERS
5.6.1 Trigger Signal
This mode determines how the reading phase is controlled when the hardware trigger operating mode is selected:
• trigger active level: the reader goes ON when the trigger is pressed and goes
OFF when it is released
• trigger active pulse: the reader goes ON at the first trigger press and goes OFF only at a second press
5.6.2 Trigger Click
When enabled, it activates a "click" sound upon each trigger pressure.
5.6.3 Trigger-Off Timeout
When this timeout is selected, the reader turns OFF automatically after the desired period of time.
5.6.4 Reads per Cycle
In general, a reading cycle corresponds to the ON + OFF times of a device.
The resulting effects of this parameter on code reading depend on other related configuration conditions. Here are the definitions of ON and OFF times.
• For readers using the software trigger parameter (FLASH MODE), a reading cycle corresponds to the flash on + flash off times. Code reading takes place during the flash on time.
• For readers using the hardware trigger parameter, a reading cycle corresponds to a trigger press (ON) + one of the following OFF events: trigger release (for trigger active level) a second trigger press (for trigger active pulse)
trigger-off timeout (see section 5.6.3).
157
POWERSCAN ® D8330/M8300
When one read per cycle is selected, the device decodes only one code during the
ON period and immediately turns the reader OFF. It is only possible to read another code when the next ON time occurs.
In multiple reads per cycle, the ON period is extended so that the device can continue decoding codes until an OFF event occurs. For software trigger mode, the
flash on period is immediately reset after each read and therefore extended. If another code is decoded before the reset flash on period expires, it is again reset and the effect is that the device remains ON, decoding codes until the flash on or
timeout period expires.
The Safety Time parameter should be used in this case to avoid unwanted multiple
reading of the same code, see section 5.6.5.
5.6.5 Safety Time
Safety time prevents the device from immediately decoding the same code more than once. Same code consecutive reading can be disabled requiring the reader to be removed from the code (no decoding) for at least 400 ms, or a timeout can be set up to 9.9 seconds before the decoder will accept the same code. Reading is immediate if the code changes.
The safety time parameter is not applicable when reading stacked codes or when setting one read per cycle in hardware trigger operating mode, since these settings require voluntary action by the user.
5.7 DECODING PARAMETERS
CAUTION
These parameters are intended to enhance the decoding capability of the reader for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error.
5.7.1 Ink-Spread
The ink-spread parameter allows the decoding of codes, which are not perfectly printed because the page texture tends to absorb the ink.
5.7.2 Overflow Control
The overflow control parameter can be disabled when decoding codes printed on small surfaces, which do not allow the use of an overflow space.
This command does not affect code families 2/5, Code 128 and Code 93.
158
REFERENCES
5.7.3 Interdigit Control
The interdigit control parameter verifies the interdigit spacing for code families
Code 39 and Codabar.
5.8 ADVANCED FORMATTING
5.8.1 Match Conditions
Selecting an Advanced Formatting and specifying a Match restriction (Code Type,
Code Length, Predefined Characters) the code will be transmitted according to the order of the defined formats.
For example, defining 2 formats where:
• Format 1: Match Code type = Code128
• Format 2: Match Code length = 15 and Match with Predefined Characters
“DATA” a Code128 “DATA:12345ABCDE” with code length 15 will be formatted following the
Format 1.
To send the same code with the Format 2 it is necessary to invert the format order as follows:
• Format 1: Match Code length = 15 and Match with Predefined Characters
“DATA”
• Format 2: Match Code type = Code128
5.9 RADIO PARAMETERS (M8300 SERIES ONLY)
5.9.1 Radio Protocol Timeout
This parameter sets the valid time to wait before transmission between the M8300 series reader and BC-80X0 cradle is considered failed.
This parameter should be set taking into consideration the radio traffic (number of readers in the same area).
If the RS-232 interface is used with ACK/NACK enabled, this parameter should be at least equal to the RX Timeout parameter for low traffic environments. It should be increased if there are many readers in the same area.
It can be set between 2 and 19 seconds.
159
POWERSCAN ® D8330/M8300
5.9.2 Radio RX Timeout
When the scanner is used in a standalone layout (point-to-point or with multiple readers) it can be configured to receive “asynchronous” messages from the host at any time.
There are two modes which can enable the scanner to receive messages from the host:
1) Enable “2 way” Communication Protocol – After the transmission of each bar code, the scanner waits for an acknowledgement from the host
message can be sent by the host accompanying this acknowledgement, or in place of it, to display something on the screen or execute a command
(such as sound a beep sequence, turn an LED on or off, etc.). If no acknowledgement or message is received from the host within a programmable timeout duration, the radio will be switched off and an “error transmission” beep will be sounded.
2) Independent of the Selected Protocol – The scanner can be configured to keep the radio receiver “awake” for a defined period of time following each transmission. Any message coming from the host1 before expiration of the timeout is accepted. The parameter “Radio RX Timeout” is used for specifying how long the scanner have to wait for a message after receiving each code transmission.
In this mode, the radio can also be “awakened” by pressing the trigger.
The scanner can receive a message only if it is linked to the Base (i.e. the scanner has been joined to the Base and has had at last one “valid” transmission after the last power-on). Setting the “Radio RX timeout” value to “00” specifies that the radio never goes into sleep mode (always awake
Æ the scanner can receive a message at any time). Choosing this setting will, of course, consume battery life more quickly.
1
See Section 6.1 for Host to Scanner message formatting.
5.9.3 Power-Off Timeout
If this command is enabled, after the desired timeout in hours, the PowerScan ® batteries are disconnected and all power consumption ceases. To restore power, press the trigger once. The reader will now be ready to read codes.
Power-off does not affect configuration parameters.
160
REFERENCES
5.9.4 Transmission Mode
This parameter determines whether the reader receives responses or messages from the Host or not. In One-Way tx mode, neither Host nor cradle responds to the reader.
In Two-Way tx mode, the reader must receive a response from either the cradle or the Host.
The cradle responds (empty message) to the reader, only after good transmission to
the Host, for the following conditions: ACK/NACK enabled, see section 5.1.2;
WEDGE or PEN interface. For these conditions, it is suggested to prolong the Radio
Protocol Timeout, see section 5.9.1.
Enabling Two-Way tx mode temporarily disables FIFO buffering see section 5.1.3.
With ACK/NACK disabled, the Host responds to the reader (through the cradle) with an answer message (message to reader display or command to reader), see section
Transmission Mode = Two-Ways data data cable
PowerScan ®
M8300
Host answer message
BC-80X0
Host answer message
Host
5.9.5 Beeper Control for Radio Response
For M8300 series readers, the data entry good read tone normally results in two beeps; the first indicates that the reader has decoded the code; the second indicates whether BC-80X0 has received the data.
This can be changed according to the following selections:
♦ Normal: both good decode and good receptions are signaled (two beeps).
♦ Only Good Decode: only the first beep indicating a good read is signaled.
♦ Only Good Reception: only the second beep indicating a good reception is signaled.
♦ Off: Neither good read nor good reception beeps are signaled.
For all configurations, any transmission errors will always be signaled.
161
POWERSCAN ® D8330/M8300
5.9.6 Single Store
When single store mode is enabled, if the PowerScan ® M8300 fails to transmit a code to the cradle, it enters a special operating mode that prevents the user from reading bar codes. When such operating mode is entered, the trigger no longer enables bar code reading but is used to retry transmission itself for the number of attempts selected in configuration. Once the transmission is successful the reader returns to the standard mode. If transmission is not successful after the number of configured attempts, the code is discarded.
Single store may be useful if you often read codes at the limit of the coverage area and there is a chance that code transmission can fail. In such case single store allows you to move to a more favorable position or location (i.e. closer to the cradle) and retry transmission without the necessity of re-reading the code since it is already stored in the reader.
Conversely, if single store is disabled, and the user wants to retry transmission, the code must be read again, and therefore the attempt must be made from basically the same location. If the user gives up, he does not know if the transaction was successful. (Actually the transmission could have been successful but the cradle may have been unable to acknowledge the message). There are applications in which there is no risk of transmission failure. In such cases it may be better to disable single store so that the user perceives a more consistent behavior of the trigger in that it always corresponds to code reading.
5.9.7 Batch Mode
This Operating Mode allows storing read codes in the internal reader RAM memory.
The stored codes are transmitted to the base station at a later time according to the type of batch mode selected.
Batch mode can be enabled either manually (normal batch mode) or automatically.
Normal batch mode temporarily suspends radio communication between reader and base station allowing codes to be stored in the reader on a FIFO basis. This can be useful for example, if codes must be read from a location where there is no radio network. Upon returning to the system working area, this mode requires reading the
Start Normal Batch Transmission bar code to successively transmit the list of stored codes to the base station. The FIFO management assures that the first code read will be the first code to be transmitted to the base station.
The Delete Batch Data bar code allows canceling all bar code data stored in the reader.
Automatic batch mode allows codes to be stored in the reader on a FIFO basis whenever the reader is out of radio range. In this case radio communication is not suspended and transmission is attempted after each code read. If transmission
162
REFERENCES cannot be successfully completed, then the code is added to the list. When the reader returns in range, transmission of the codes to the base station resumes automatically, according to the selected communication protocol, upon simply pressing and releasing the trigger or by successfully reading a new code.
Each code is listed on the reader display together with its identifying position number and its total number of characters. The three keys under the display have the following function in batch mode:
Key Function
▲ (left) Key
ENTER (center) Key
Scroll up in list
Delete highlighted code
▼ (right) Key Scroll down in list
In batch mode, the selected Transmission Mode determines the behavior of the reader at the time the list of codes is transmitted. If One-way mode is enabled, the codes are transmitted one after the other without interruption. In Two-way mode, after transmitting each code, the reader waits for the Host answer message to be shown on the display. Therefore, in Two-way transmission mode and normal batch mode, the Start Normal Batch Transmission bar code must be read after each code to continue, whereas with automatic batch mode just pull and release the trigger after each code.
The code, which has a transmission pending, is shown on the display in reverse video indicating that it cannot be deleted.
5.9.8 Find Me (PowerScan ® M8300 only)
If enabled, after a timeout of a few minutes in which PowerScan ® M8300 is not used, it enters stand-by mode and its green LED starts blinking in order to signal its location.
163
POWERSCAN ® D8330/M8300
5.10 DISPLAY PARAMETERS (SOME M8300 MODELS ONLY)
5.10.1 Display Mode
The user can control the reader display behavior according to the following selections:
Normal mode: When a bar code is read with the reader:
• The code is sent to the Host.
• The reader display is not cleared. Therefore if any previous data was displayed on the reader screen it remains.
• There is no Local Echo to the reader display.
Clear Display After Decode mode: When a bar code is read with the reader:
• The code is sent to the Host.
• The reader display is cleared. Therefore if any previous data was displayed on the reader screen it is cancelled and the screen remains blank.
• There is no Local Echo of the code to the reader display.
Local Echo mode: When a bar code is read with the reader:
• The code is sent to the Host.
• The reader display is cleared.
• The code is also sent to the reader display (Local Echo).
• The cursor is positioned after the last printed character on the reader display.
Host messages sent to the reader are always written to the reader display.
164
REFERENCES
5.11 CONFIGURATION EDITING COMMANDS
The following commands carry out their specific function and then exit the configuration environment.
Command Description
Ì$+$*oÎ
Restore PowerScan
®
reader default configuration (see the relative Quick Reference
Guide for default settings)
Ì$+$!KÎ
Transmit the PowerScan
®
PowerScan
®
D8330 or
M8300 software release
Ì$+$&_Î
Transmit PowerScan
®
ASCII format.
reader configuration in
This command is not effective with Pen emulation interface.
Ì$+RX0$-qÎ
Restore BC-80X0 default configuration (see the relative Quick Reference Guide for default settings)
Ì$+RX1$-vÎ
Transmit the BC-80X0 Software release.
Ì$+RX2$-{Î
Transmit BC-80X0 configuration in ASCII format.
This command is not effective with Pen emulation interface.
165
POWERSCAN ® D8330/M8300
5.12 CUSTOM DEFAULT CONFIGURATION
Read the following code to set the reader user-defined configuration as custom default configuration:
Save User-defined Configuration as Custom Default
Ì$+$0ÂÎ
Read the following code whenever you need to restore the custom default configuration:
Restore Custom Default Configuration
Ì$+$1$Î
5.13 CODE TYPE RECOGNITION
This procedure allows the reader to enter a particular state during which it reads and transmits to the Host information about the family type of codes unknown to the user
(with the exception of MSI, Code 49 and Code 16k code types). It is also possible to read and transmit configuration strings without interpreting them.
All codes are read ignoring the check digit.
Follow the given procedure: c Read the following code to enter the code type recognition mode: code type recognition
Ì#+CODEÂÎ
d Read existing codes whose family type you need to check. e Read the following code to return to the reader's normal functioning: exit code type recognition mode
Ì$-?Î
166
REFERENCES
5.14 CONFIGURATION COPYING COMMANDS
5.14.1 Copy PowerScan ® D8330 Series
Procedure: c Connect the master (correctly configured reader) and the slave (reader to be configured) together through two RS-232 serial interface cables and external power supply. Accessory cables and power supply are available from your
Psion Teklogix distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG5 d Using the slave reader, read the Restore Default bar code and then the RS-232
interface bar code from chapter 4 of this manual or from the Quick Reference
Guide. e With the master reader, read the Configuration Copy bar code below.
Copy Configuration
Ì$+ZZ0$-*Î
The configuration will be copied from the master to the slave reader. The slave reader signals the end of the procedure with a series of beeps.
Note: The master reader can be configured for any interface.
167
POWERSCAN ® D8330/M8300
5.14.2 Copy PowerScan ® M8300 Series
Procedure: c Using the slave reader and its BC-80X0 cradle, follow the initialization
procedure in chapter 4 of this manual or from the Quick Reference Guide.
d With the master PowerScan
®
M8300 (correctly configured reader), read the
Copy Configuration bar code below. Then place it onto an BC-80X0 cradle within 10 seconds. The reader will beep indicating the configuration has been copied.
The configuration will be simultaneously sent over the RS-232 interface of the
BC-80X0. If this causes undesired effects disconnect the RS-232 cable between the PC and BC-80X0 during this process.
Copy Configuration
Ì$+ZZ0$-*Î
e With the slave PowerScan
®
M8300, read the Get Configuration bar code below.
Then place it onto the same BC-80X0 cradle used in the step above. The slave reader's address will not be changed.
Get Configuration
Ì$+ZZ2$-4Î
The configuration will be copied from the master to the slave PowerScan
®
The slave PowerScan ®
M8300.
M8300 signals the end of the procedure with a series of beeps. It is now ready to be used with its own BC-80X0 cradle. f Repeat the procedure above to configure other slave readers. The
BC-80X0 can continue to configure slave readers until it receives another command or data.
168
REFERENCES
5.14.3 Copy BC-80X0
Procedure: c Using the slave reader and its BC-80X0 cradle, read the Restore Default bar code, set the radio address, and then read the RS-232 interface bar code from
chapter 4 of this manual or from the Quick Reference Guide.
d Connect the master BC-80X0 and the slave BC-80X0 (cradle to be configured) together through two RS-232 serial interface cables and external power supply.
Accessory cables and power supply are available from your Psion Teklogix distributor to provide this connection.
RS-232 Cables: CAB471 & CAB472
Power Supply: PG12 e Read the Configuration Copy bar code below with a reader. Then place it onto the master BC-80X0 cradle.
Copy Configuration
Ì$+ZZ3$-9Î
The configuration will be copied from the master BC-80X0 to the slave
BC-80X0. The reader signals the end of the procedure with a series of beeps. f Repeat the procedure above to configure other slave cradles.
Note: The master BC-80X0 can be configured for any interface.
169
POWERSCAN ® D8330/M8300
5.15 DEFAULT PARAMETERS FOR POS TERMINALS
The default values of the RS-232 and Data Format parameters for POS terminals are listed in the following table:
RS-232 Group
Baud Rate
Data Bits
Stop Bits
Handshaking
ACK/NACK Protocol
Inter-Character Delay
RX Timeout
Serial Trigger Lock
Data Format Group
Code Identifier
Header
9600
8
1
Hardware (RTS/CTS)
Disabled
Disabled
9.9 sec
Disabled
Custom
No Header
9600
8
1
None
Disabled
Disabled
2 sec
Disabled
Custom
No Header
9600
8
1
RTS always ON
Disabled
Disabled
9.9 sec
Disabled
Custom
No Header
Field Adjustment
Code Length TX
Character Replacement
Address Stamping
Address Delimiter
Time Stamping
Time Delimiter
Disabled
Not Transmitted
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Not Transmitted
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
Not Transmitted
Disabled
Disabled
Disabled
Disabled
Disabled
The table below lists all the Code Identifiers available for the POS terminals:
Code 39
Code 128
Interleaved 2 of 5
Code 93
Industrial 2 of 5
UCC/EAN 128
GS1 DATABAR™
170
M
K
I
L
H
P
E
None
None
None
None
None
None
None
C [code length]
L [code length]
I [code length]
None
H [code length]
L [code length]
None
REFERENCES
5.16 FIRMWARE UPGRADE
Device firmware upgrades can be performed using the Downloader utility tool
(downloadable from the original manufacturer’s web site: http://www.scanning.datalogic.com
) from your PC through the USB communication.
Procedure: c Launch the Downloader tool on your PC. d Connect the device to the PC via USB interface. e Read the code given below and position the reader onto the cradle: prepare device for firmware upgrade
Ì$+RN2$-SÎ
OR
Press the cradle button if present (to only update the cradle).
The device will automatically be reset. f Proceed with the firmware upgrade (see the Downloader utility help on-line for details).
CAUTION
Do not interrupt firmware upgrade downloading for any reason.
171
POWERSCAN ® D8330/M8300
6 MESSAGE FORMATTING
The system always provides scanner to host data communication using the following message formatting:
Output Message from PowerScan
®
D8330 or PowerScan
®
M8300 Stand-alone
Towards Host
[Header] [Scanner_Addr] [Scanner_Addr_delimiter] ] [Cradle_Addr] [Cradle_Addr_delimiter]
[Time stamp] [Ts_delimiter] [Code ID] [Code Length] CODE [Terminator]
[Items in square brackets are optional.]
Output Message from PowerScan
®
M8300 STAR-System™ Towards Host
[Time stamp] [Ts_delimiter] [Header] [Code ID] [Code Length] CODE [Terminator]
[Items in square brackets are optional.]
For PowerScan ® M8300 models with display, if the RS-232 interface is selected for communication between the Host and the BC-80X0 cradle, then the following additional communications between Host and Scanner can occur:
• The Host can send messages to any scanner associated with that cradle to control the Scanner’s display, LEDs and beeper.
• The Scanner can send up to 3 user-defined characters to the Host using the 3 command keys on the Scanner.
These communications and their relative message formatting are detailed in the following paragraphs.
6.1 MESSAGES FROM HOST TO READER
The general format to enable the Scanner for a 2 way communication is:
[Scanner_Addr] [Scanner_Addr_delimiter] MESSAGE [CR]
NOTE:
• If you have enabled the Scanner Address Stamping or the Scanner Address
Delimiter, you must specify them in every message.
172
MESSAGE FORMATTING
The general format for other asynchronous messages is:
[Scanner_Addr] [Scanner_Addr_delimiter] [DC2] MESSAGE [CR]
where DC2 is ASCII 0x12 (^R) character.
• If you have not enabled the Scanner Address Stamping or the Scanner Address
Delimiter, you must not specify them. In this case all messages will be implicitly addressed to the 'binded' Scanner of the cradle directly connected to the serial line.
• The Scanner can only receive messages if two-way mode is enabled. (See
section 5.9.4, “Transmission Mode”, command is on page 160).
• Messages cannot start with '$+' because they would be interpreted as a configuration command.
• You can send a message to the Scanner only while it is on. This happens when it has sent a message to the host and the radio timeout has not yet expired. (See
section 5.9.1, "Radio Protocol Timeout"; command is on page 131).
• If you want to control the Scanner's beeper from the host, you will also probably want to disable the good transmission beep that is emitted when the code is
received from the cradle. (See command on page 87).
The message field can store plain text and escape sequences.
• Escape sequences are interpreted as commands.
• Plain text is directly printed on the display. If writing beyond the end of line, the display does not wrap automatically. Extra characters are ignored. Control characters are not interpreted (i.e. LF, FF, etc.).
6.1.1 Cursor Control
ESC [
ESC [
ESC [
ESC [ n A n B n C n
ESC [ G
D
ESC [ r ; c H
Up n rows, no scroll
Down
Right
Left
CR n n
rows, no scroll
columns n columns
Move to row r , column c
(ESC[1;1H is the upper left character position of the display)
ESC D
ESC E
ESC M
Down 1 row, with scroll
CR and cursor down 1 row with scroll
Up 1 row and scroll
NOTES:
• Since CR is used as the message terminator, you must use ESC [ G or ESC E to print a CR.
173
POWERSCAN ® D8330/M8300
• The cursor row position is not affected by the currently selected font. The display always has 4 rows, so when writing with the large font, actually two rows are written to: the current one and the one below it. You will need two ESC E commands to step from one row to the next when using the large font.
• The cursor column position is affected by the currently selected font. Therefore, column 6 is 36 pixels from the left border only if you last selected the 6x8 font; otherwise it could be 48 or 72 pixels from the left border.
6.1.2 Font Selection
ESC [ 0 m
ESC [ 7 m
ESC # 4
Normal mode
Reverse mode
Large font: subsequent characters are written on the current row and the row below it using the 12x16 font which allows for two rows of eight characters on the display.
ESC # 5 Normal font: subsequent characters are written using the 6x8 font, which allows for four rows of sixteen characters on the display.
ESC # 7 Medium font: subsequent characters are written using the 8x8 font, which allows for four rows of twelve characters on the display.
6.1.3 Clearing Display
ESC [ 0 K
ESC [ 1 K
ESC [ 2 K
ESC [ 0 J
ESC [ 1 J
ESC [ 2 J
From cursor position to end of line inclusive
From beginning of line to cursor position (not inclusive)
Entire line
From cursor position to end of display inclusive
From beginning of display to cursor position (not inclusive)
Entire display; moves cursor to upper left corner on display
6.1.4 LED and Beeper Control
ESC [ 0 q
ESC [ 1 q
ESC [ 2 q
ESC [ 3 q
ESC [ 4 q
ESC [ 5 q
ESC [ 6 q
ESC [ 7 q
ESC [ 8 q
ESC [ 9 q
Emit short High tone + short delay
Emit short Low tone + short delay
Emit long Low tone + short delay
Emit good read tone
Emit bad tx tone
Wait 100 ms
Turn on the green LED
Turn off the green LED
Turn on the red LED
Turn off the red LED
174
MESSAGE FORMATTING
The LED control escape sequences are intended to activate the LEDs for short periods of time and can be used in combination with the Beeper. The LED and
Beeper will be controlled by the system after the entire command sequence is interpreted.
Example:
ESC [ 6 q ESC [ 3 q ESC [ 7 q Turns on the green LED, emits a good read tone, and turns off the green LED.
ESC [ 6 q ESC [ 5 q ESC [ 7 q Turns on the green LED for 100 ms and then turns off the green LED.
6.1.5 Setting RTC
ESC [ 0 p d d m m y y
ESC [ 1 p h h m m
Set date to day, month, year
Set time to hours, minutes; seconds are automatically set to 00.
6.2 MESSAGES FROM SCANNER COMMAND KEYS
The PowerScan ® M8300 series scanners with display have 3 command keys that can each be associated with a character to send to the host.
By pressing the keys on the scanner, the associated character with its relative message formatting is sent to the Host. For example, keys can be used to select items from a menu sent to the scanner display by the application program.
The general format is:
[Header] [Scanner_Addr] [Scanner_Addr_delimiter] ] [Cradle_Addr] [Cradle_Addr_delimiter]
[Time stamp] [Ts_delimiter] [Code ID] [Code Length] KeyID [Terminator]
[Items in square brackets are optional.]
The messages are handled by the system as if they were bar codes, that's why
KeyID can have so many fields appended to it. If in your application there is some chance of reading a 1-char bar code identical to KeyID, the way you can distinguish between the two is to enable the Code ID: The KeyID is the only 1-character long
EAN 8 code.
Refer to section 5.3 for a compete description of the optional message fields in
square brackets.
175
POWERSCAN ® D8330/M8300
The default characters associated with each key (KeyID) are shown in the following table:
Default Key Identifiers
Key KeyID
▲ (left) Key
ENTER (center) Key
'<'
'='
'>'
176
TECHNICAL FEATURES
7 TECHNICAL FEATURES
7.1 POWERSCAN ® D8330
Electrical Features
Power Supply
Max. Consumption
@ 4V
@ 5V
@ 30 V
Sleep Mode
Reading Indicators
Host Interfaces
RS-232
PowerScan® D8330 PowerScan® D8330 AR
4 to 30 VDC
420 mA
310 mA
62 mA
4 mA
500 mA
370 mA
70 mA
4 mA
Good Read LED (green)
Good Read Spot (green), Beeper
300 to 38400 baud
WEDGE
PEN Emulation
USB
IBM AT or PS/2, XT, PC Notebook, IBM SURE1, IBM 3153, 31xx, 32xx,
34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB
Bus supported
Selectable minimum pulse from 200 μ S to 1.2 mS
USB-KBD, USB-KBD-ALT-MODE, USB-KBD APPLE, USB-COM, USB-
IBM-Table Top, USB-IBM-Hand Held
Laser Features
Light Source
Scan Rate
Power (max) in mW
Scan Angle
PCS minimum
(Manufacturer’s Test Chart)
Maximum Resolution
Reading Field Width
Laser Safety Class
Environmental Features
Working Temperature
Storage Temperature
Humidity
Drop resistance (on concrete)
Protection class
Mechanical Features
Weight (without cable)
Dimensions
Cable length
Material
VLD between 630~680 nm
35 ± 5 scans/sec
0.9 mW
42°
1.3 mW
13.5° ± 0.7
15% 25%
0.076 mm (3 mils) 0.19 mm (7.5 mils)
see reading diagrams (section 7.6)
Class 2 EN 60825-1/CDRH
-30° to +50 °C / -22° to +122 °F
-30° to +70 °C / -22° to +158 °F
90% non condensing
IEC 68-2-32 Test ED 2 m
IP65 about 295 g (10.4 oz)
205 x 114 x 69 mm (8.07 x 4.49 x 2.72 in)
2 m (6 ft 6 in)
Polycarbonate molded with rubber
177
POWERSCAN ® D8330/M8300
7.2 POWERSCAN ® M8300
Electrical and General Features
Battery Type
Recharge Time
Operating autonomy
(continuous reading)
Display
(Only available with some models)
Indicators
Laser Features
Light Source
Scan Rate
Power (max) in mW
Scan Angle
PCS minimum
(Manufacturer’s Test Chart)
Maximum Resolution
Reading Field Width
Laser Safety Class
Environmental Features
Working Temperature
Storage Temperature
Humidity
Drop resistance (on concrete)
IEC 68-2-32 Test ED
Protection Class
Mechanical Features
Weight (with batteries)
Dimensions
Material
2150 Li-Ion battery pack max. 4 hours with external power supply max 10 hours with Host power
60,000 reads (typical)
LCD 4 lines x 16 chars
Programmable font and backlight
Good Read LED (green)
Good Read Spot (green), Beeper
VLD between 630~680 nm
35 ± 5 scans/sec
0.9 mW
42°
1.3 mW
13.5° ± 0.7
15% 25%
0.076 mm (3 mils) 0.19 mm (7.5 mils)
see reading diagrams (section 7.6)
CLASS 2 EN 60825-1 / CDRH
-20° to +50 °C / -4° to +122 °F
-20° to +70 °C / -4° to +158 °F
90% non condensing
2 m
IP65 (IP64 for models with display) about 400 g (14.10 oz)
212 x 109 x 71 mm (8.34 x 4.49 x 2.79 in)
Polycarbonate molded with rubber
178
TECHNICAL FEATURES
7.3 BC-80X0 / C-8000
Electrical and General Features
Supply Voltage
External Power
Host Power
BC-80X0 C-8000
10 to 30 VDC
5 VDC ±10%
Power Consumption
External Power max. 10 W (charging)*
Host Power
Indicators max. 500 mA (charging)
Ext. Power /Data yellow LED
Host Power/Data yellow LED
Reader batt. state green/red LED
Aux. batt. state green/red LED (BC-8000/C-8000 only) beeper
Recharge Time
External Power
Host Power max. 4 hours with 2150 mAh Li-Ion battery
Host Interfaces
RS-232
WEDGE
PEN Emulation
USB max. 10 hours with 2150 mAh Li-Ion battery
300 to 38400 baud
IBM AT or PS/2, XT, PC Notebook, IBM
SURE1, IBM 3153, 31xx, 32xx, 34xx, 37xx terminals, Wyse terminals, Digital VT terminals, Apple ADB Bus supported
Selectable minimum pulse from
200 μ S to 1.2 mS
USB-KBD, USB-KBD-ALT-MODE, USB-
KBD APPLE, USB-COM, USB-IBM-Table
Top, USB-IBM-Hand Held
9600 baud
Not supported
Not supported
USB-COM
Environmental Features
Working Temperature
Storage Temperature
Humidity
-20° to +50 °C / -4° to +122 °F**
-20° to +70 C / -4° to +158° F
90% non condensing
Protection IP40
Mechanical Features
Weight without cable
Dimensions (without antenna) about 380 g / 13.4 oz
204 x 108 x 95 mm / 9.44 x 4.25 x 3.74 in
Material ABS
* Having a switching regulator inside, the BC-80X0 and C-8000 draw the same power, regardless of the supply voltage. i.e. as the input voltage increases the current drawn decreases.
** Batteries must be charged at a temperature ranging from 0° to +40 °C / +32° to +104 °F.
179
POWERSCAN ® D8330/M8300
7.4 SYSTEM AND RADIO FEATURES
Radio Features
Radio Frequency
Bit Rate
Range (in open air)
European Models
433.92 MHz
19200
50 m
USA Models
910 MHz
36800
30 m
System Configurations
Maximum number of devices per base station
Maximum number of devices in the same reading area
Maximum number of base stations in network
BC-8000 model only
32 255
2000
STARGATE™
16 (including cradle Master)
7.5 STATUS INDICATORS
The scanner has two indicator LEDs and a Beeper. The BC-8000 and C-8000 cradles have four LED indicators (three for BC-8010 model) and a Beeper. They signal several operating conditions, which are described in the tables below.
L = low tone
POWERSCAN
H = high tone
®
D8330/M8300 READER START-UP
Beeper ¹
L L L L
Meaning
Parameters loaded correctly
H H H H long tones
Parameter loading error, reading or writing error in the non volatile memory
H L H L Hardware error in EEPROM
POWERSCAN
®
D8330/M8300 READER CONFIGURATION
Beeper ¹ Meaning
H H H H
L
L L L
Correct entry or exit from Configuration mode
Good read of a command
Command read error
180
TECHNICAL FEATURES
POWERSCAN
®
D8330/M8300 READER DATA ENTRY
Beeper ¹ one beep²
H L long
ON ON Correct read of a code in normal mode
TX buffer full (when FIFO is enabled) or
TX error between PowerScan
®
M8300 and BC-8000
H long
H H H
ON ON Successful advanced format concatenation
Timeout expired – operation not completed
Error in advanced data formatting H H long
OFF OFF Ready to read a code
¹ Only the Beeper Intensity command can modify these signals.
² The data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameters section.
For M-series readers, normally this results in two beeps; the first indicates that the reader has decoded the code, the second indicates whether BC-80X0 has received
the data. See also section 5.9.5.
POWERSCAN ® M8300 POWER
Beeper LED Meaning
10 short H 10 short blinks Low Battery
H M L Power off
H = high tone
M = medium tone
L = low tone
POWERSCAN
®
M8300 BIND, JOIN, COPY COMMANDS
Beeper ¹ LED Meaning
Blinking Command accepted; reader ready to be inserted into the cradle
H L long tones Failure
181
POWERSCAN ® D8330/M8300
BC-80X0/C-8000 POWER/COMMUNICATION
Aux LED Host LED
Meaning
Yellow Yellow
ON Power applied through an external power supply
Power applied through the Host ON
Flashing Flashing Transmission over the Host port
BC-80X0/C-8000 CHARGE STATUS
Reader LED
Red Green Beeper
Meaning
OFF
ON
OFF
ON
Flashing orange
Alternating red/green single beep
No reader battery inserted
Reader battery in charge
Reader battery completely charged
Reader battery fault repetitive beep Charging out of temperature range, overcurrent or over-voltage conditions
Alternating red/green every 30 seconds
Alternating red/green every 30 seconds beep every 30 seconds
Reader not correctly inserted onto cradle, no charging takes place
Spare LED (not for BC-8010)
Red Green Beeper
Meaning
OFF
ON
OFF No Spare battery inserted in the SBS-3000 slot
Spare battery in charge
ON
Flashing orange
Alternating red/green
Spare battery completely charged
Spare battery fault repetitive beep Charging out of temperature range, overcurrent or over-voltage conditions beep every 30 seconds
Spare battery not correctly inserted into SBS-
3000, no charging takes place
182
TECHNICAL FEATURES
7.6 READING DIAGRAMS
POWERSCAN
®
D8330/M8300
48 60 72 84 96 108 cm
36
24
12
0
12
24
36 cm
0.13 mm
( 5 mils)
0.19 mm
( 7.5 mils)
(
0.25 mm
10 mils) 0.33 mm
( 13 mils)
0.38 mm
( 15 mils)
0.50 mm
( 20 mils)
1.00 mm
( 40 mils) 1.38 mm
( 55 mils)
POWERSCAN
®
D8330/M8300 AR models
100 200 300 400 500 600 700 800 900 1000 cm
300
200
1.75 mm *
( 70 mils)
2.50 mm *
( 100 mils)
100
0
100
200
1.00 mm
( 40 mils)
1.38 mm
( 55 mils)
300 cm
*on reflective labels.
NOTE: Typical performance at 20ºC / 68ºF on high quality bar codes
183
POWERSCAN ® D8330/M8300
A HOST CONFIGURATION STRINGS
In this section we provide a description of how to modify the device configuration using serial strings sent from the Host.
This method requires the RS-232 interface.
The device configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following:
$+ Command $CR
Carriage return character (0D Hex.)
Exit and Save configuration
Character sequence in following tables
Enter configuration environment
Example:
$+ BG1
Multiple command programming sequence:
BH0 AC410132 $CR
Carriage return character (0D Hex.)
Exit and save new configuration
Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters
Beeper tone 1
Beeper low intensity
Enter configuration environment
Each configuration parameter setting removes the condition previously active for that parameter.
The device buffer can contain about 400 characters. If your programming string goes over this value, you must split it into separate groups and send each group after a delay of at least 3 seconds to give the reader time to empty the buffer and interpret the commands.
NOTE
184
HOST CONFIGURATION STRINGS
SERIAL CONFIGURATION STRINGS
SPECIAL CONFIGURATION COMMANDS
DESCRIPTION STRING
Enter Configuration
Exit and Save Configuration
$+
$-
Restore Default
Transmit Software Release (not for PEN emulation)
Transmit Device Configuration in ASCII (not for PEN emulation)
Set Custom Default
Restore Custom Default
$+$*
$+$!
$+$&
$+$0
$+$1
These commands do not require $-.
INTERFACE SELECTION
DESCRIPTION STRING
RS-232 Standard CP0
Fujitsu for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard
CM0
CM1
CM2EC0
CP500
CP501
CP502
32xx, 34xx, 37xx advanced for IBM Terminal 3153 for IBM PC Notebook for IBM AT - ALT mode for IBM PC Notebook - ALT mode for Wyse Terminal - ANSI Keyboard for Wyse Terminal - PC Keyboard for Wyse Terminal - ASCII Keyboard for Wyse Terminal - VT220 style Keyboard for Digital Terminals VT2xx/3xx/4xx
PEN EMULATION
USB USB-KBD
USB-KBD-ALT-MODE
USB-KBD-APPLE
USB-COM
FK1
CP503
CP504
CP505
CP506
CP507
CP508
CP509
CP510
CP511
CP514
CP512
CP6
UA03
UA04
UA05
UA02
UA00
UA01
185
POWERSCAN ® D8330/M8300
RS-232
DESCRIPTION STRING
Baud Rate 300
600
CD1
CD2
1200
2400
4800
9600
CD3
CD4
CD5
CD6
19200
38400
Parity none
even
odd
CD7
CD8
CC0
CC1
CC2
Data Bits 7
8
9
Stop Bits 1
2
Handshaking disable
RTS/CTS
XON/XOFF
CA0
CA1
CA2
CB0
CB1
CE0
CE1
CE2
ACK/NACK Protocol disable
enable
FIFO disable
enable
CE3
ER0
ER1
EC0
EC1
Inter-character Delay (ms)
RX Timeout (100 ms)
Serial Trigger Lock disable enable and select characters
CK00 - CK99
CL00 - CL99
CR0
CR1 ab
a = Hex values representing an ASCII character from 00 to FE enabling the device trigger.
b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.
186
HOST CONFIGURATION STRINGS
USB
DESCRIPTION STRING
USB-COM
Handshaking disable CE0
RTS/CTS
XON/XOFF
CE1
CE2
RTS CE3
ACK/NACK Protocol
Inter-character Delay (ms)
RX Timeout (100 ms)
Serial Trigger Lock
USB-KBD
Keyboard Nationality
(not for USB-KBD-ALT-MODE) disable
enable
FIFO disable
enable disable
enable
Belgian
English (UK)
French
German
Italian
Spanish
Swedish
USA
Keyboard Nationality
(IBM AT compatible only)
Japanese
Russian (Latin)
ER0
ER1
EC0
EC1
CK00 - CK99
CL00 - CL99
CR0
CR1 ab
FJ7
FJ4
FJ2
FJ3
FJ1
FJ6
FJ5
FJ0
FJ8
FJ9
Hungarian
Slovenian, Croatian, Serbian (Latin)
FIFO disable
enable
FJB
FJC
Romanian FJD
Czech FJE
EC0
EC1
CK00 - CK99
FG00 - FG99
USB Keyboard Speed normal
fast
UT10
UT01
a = Hex values representing an ASCII character from 00 to FE enabling the device trigger.
b = HEX values representing an ASCII character from 00 to FE inhibiting the device trigger.
187
POWERSCAN ® D8330/M8300
WEDGE
DESCRIPTION STRING
Keyboard Nationality Belgian FJ7
French FJ2
German FJ3
Italian FJ1
Spanish FJ6
Swedish FJ5
USA FJ0
Keyboard Nationality
(IBM AT compatible only)
Japanese
Russian (Latin)
FJ8
FJ9
Russian FJA
Slovenian, Croatian, Serbian (Latin) FJC
Caps Lock caps Lock ON FE1
Caps Lock Auto-Recognition
(IBM AT compatible only)
Num Lock
Delays disable enable toggle num lock num lock unchanged
Inter-Character (ms)
Inter-Code (s)
Ctrl + Shift + Key
Ctrl + Key
FP0
FP1
FL1
FL0
CK00 - CK99
FG00 - FG99
FO0
FO1
Control Character Emulation
PEN
DESCRIPTION STRING
Operating Mode
Minimum Output Pulse interpret (does not require $+ or $-) transparent (does not require $+ or $-)
200 μ s
400 μ s
600 μ s
800 μ s
$]
$[
DG0
DG1
DG2
DG3
DG4
DG5
DA0 Conversion to Code 39 and
Code 128 disable conversion to Code 39
(D series only) enable conversion to Code 39 enable conversion to Code 128
(M series only)
Output Level normal
inverted
DA1
DA2
DD0
DD1
188
HOST CONFIGURATION STRINGS
PEN (continued)
DESCRIPTION STRING
Idle Level normal
inverted
DE0
DE1
DH0
Inter-block Delay (100 ms) CK00-CK99
NETWORK
DESCRIPTION STRING
RS-485 Network Disable Network RZ0
Slave Address Range Minimum Address JB0000-1999
x =
Network Baud Rate 9600
19200
38400
Network Warning Message not transmitted
transmitted
Transmission Warning not transmitted
JE0
JE1
JE2
JG0
JG1
JH0
Message transmitted
Master Header no header
JH1
JA00
JA01 x
JA02 xx
JA03 xxx
JA04 xxxx
JA05 xxxxx
JA06 xxxxxx
seven xxxxxxx
eight xxxxxxxx
Master Terminator no terminator JA10
JA11 x
JA12 xx
JA13 xxx
JA14 xxxx
Five JA15 xxxxx
six JA16 xxxxxx
seven xxxxxxx
eight xxxxxxxx
Hex value from 00 to FE representing an ASCII character
189
POWERSCAN ® D8330/M8300
DATA FORMAT
NOT FOR PEN EMULATION INTERFACES
DESCRIPTION STRING
Code Identifier disable EB0
custom
Custom Code Identifier
EB2
EB3
EH abc
EA00
EA01 x
EA02 xx
three EA03 xxx
EA04 xxxx
EA05 xxxxx
EA06 xxxxxx
seven xxxxxxx
eight xxxxxxxx
EA10
EA11 x
EA12 xx
three EA13 xxx
EA14 xxxx
EA15 xxxxx
EA16 xxxxxx
seven xxxxxxx
eight xxxxxxxx
a = ASCII character.
b, c, x = HEX values representing an ASCII character.
a = ASCII character of the MANUFACTURER STANDARD Code Identifier from the table on
b = Hex value of the first Custom Code Identifier character from 00 to FD;
FF = disable Code Identifier
c = Hex value of the second Custom Code Identifier character from 00 to FD;
FF = disable second character of Custom Code Identifier
x = Hex value from 00 to FE
190
HOST CONFIGURATION STRINGS
DATA FORMAT (continued)
NOT FOR PEN EMULATION INTERFACES
DESCRIPTION STRING
Code Length Tx
Field Adjustment not transmitted transmitted in variable-digit format transmitted in fixed 4-digit format disable left deletion
EE0
EE1
EE2
EF0
EF a0d
EF a1d
EF a2d
EF a3d
Field Adjustment Character
Character Replacement disable character replacement second character replacement
EG e
EO0
EO1 afg
EO2 afg
Address Stamping
Address Delimiter
Time Stamping disable reader address stamping enable reader address stamping disable cradle address stamping enable cradle address stamping disable reader address delimiter enable reader address delimiter and select character disable cradle address delimiter enable cradle address delimiter and select character disable
RU0
RU1
RW0
RW1
RV0
RV1 h
RY0
RY1 h
IL0
hour/minutes/seconds IL3
month/day/year
day/month/year
Time Stamping Delimiter disable time stamping delimiter enable time stamping delimiter and select character
IL4
IL5
IM0
IM1 h
a = ASCII character.
d = a number from the Hex/Numeric Table
e, f, g, h = HEX values representing an ASCII character
a = ASCII character of the MANUFACTURER STANDARD Code Identifier from the table on
d = a number in the range 01-32 from the Hex/Numeric Table
e = Hex value from 00 to FE
f = Hex value of the character to be replaced from 00 to FE
g = Hex value of the new character to insert from 00 to FE
FF = replace with no new character (remove character)
h = a HEX value in the range from 00 - FE representing the ASCII character.
191
POWERSCAN ® D8330/M8300
POWER SAVE
DESCRIPTION STRING
Sleep State
(only for D8330 series) disable enable
BQ0
BQ1
Enter Sleep Timeout (100 ms) BR00-BR99
READING PARAMETERS
DESCRIPTION STRING
Trigger Type software trigger BK0
Trigger Signal trigger active level
BK3
BA0
Trigger Click disable
enable
Trigger-off Timeout (s)
FLASH ON (100 ms)
FLASH OFF (100 ms)
Reads per Cycle one read
Bc0
Bc1
BD00 - BD99
BB001 - BB099
BB101 - BB199
BC0
Safety Time (100 ms)
Beeper Intensity very low intensity
BE00 - BE99
BG0
Beeper Tone tone 1
Beeper Type monotone
bitonal
Beeper Length long
short
Good Read Spot Duration disable
short
medium
long
BV0
BV1
BV2
BV3
Aiming System disabled
enabled
Bj0
Bj1
Cradle Beeper Intensity disable JI0
low JI1
BH0
BH1
BH2
BH3
BJ0
BJ1
BI0
BI1
192
HOST CONFIGURATION STRINGS
DECODING PARAMETERS
DESCRIPTION STRING
Ink-spread disable
enable
AX0
AX1
Overflow Control
enable
Interdigit Control
enable
Puzzle Solver TM disable disable
disable
enable
Decoding Safety one read
AW1
AW0
AV0
AV1
AU0
AU1
ED0
ED1
ED2
ED3
CODE SELECTION
DESCRIPTION STRING
DISABLE ALL FAMILY CODES AZ0
EAN 8/EAN 13/UPC A/UPC E without ADD ON with ADD ON
EAN 8/EAN 13
UPC A/UPC E with and without ADD ON without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5 without ADD ON with ADD ON 2 ONLY with ADD ON 5 ONLY with ADD ON 2 AND 5
EAN/UPC with and without Add On no Autodiscrimination
EAN/UPC Autodiscrimination Add On by Prefix
Select Prefixes cancel all selections
378/379
434/439
414/419
977
978
979
EAN 8 check digit transmission disable enable
EAN 13 check digit transmission disable enable
AA0
AA1
AA5
AA8
AA3
AAK
AAL
AA6
AA4
AAM
AAN
AA7
AA8Ad0
AA8Ad1
ET0
ET1378ET2379
ET3434ET4439
ET5414ET6419
ET7977
ET8978
ET9979
AAG0
AAG1
AAH0
AAH1
CODE SELECTION (continued)
193
POWERSCAN ® D8330/M8300
DESCRIPTION STRING
UPC A check digit transmission disable AAI0
UPC E check digit transmission conversions enable disable enable
UPC E to UPC A
UPC E to EAN 13
UPC A to EAN 13
AAI1
AAJ0
AAJ1
AAA
AAB
AAC
ISBN Conversion codes
EAN 8 to EAN 13 enable ISBN
AAD
AP1 enable ISSN AP2 enable ISBN and ISSN disable ISBN and ISSN
Code 39 disable Code 39 family
Standard no check digit control
Full ASCII check digit control and transmission check digit control without transmission no check digit control check digit control and transmission check digit control without transmission
2/5 disable Code 2/5 family
Interleaved 2/5
Normal 2/5 5 bars no check digit control check digit control and transmission check digit control without transmission
Industrial 2/5 (IATA) no check digit control
Matrix 2/5 3 bars
CIP/HR no check digit control check digit control and transmission check digit control without transmission check digit control and transmission check digit control without transmission no check digit control check digit control and transmission check digit control without transmission
xxxx = ASCII numbers that define the code length where:
AP3
AP0
AB0
AB11
AB12
AB13
AB21
AB22
AB23
AB3
AB4
AB* xxxx
AC0
AC11 xxxx
AC12 xxxx
AC13 xxxx
AC21 xxxx
AC22 xxxx
AC23 xxxx
AC31 xxxx
AC32 xxxx
AC33 xxxx
AC41 xxxx
AC42 xxxx
AC43 xxxx
AC5
•
•
First 2 digits = minimum acceptable code length.
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
Examples:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
194
HOST CONFIGURATION STRINGS
CODE SELECTION (continued)
DESCRIPTION STRING
AD0
AD111 Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission
ABC Codabar start/stop character equality control and transmission no start/stop character equality control but transmission
Codabar ABC forced concatenation start/stop character case in transmission lower case
AD112
AD121
AD122
AD212
AD232
AD* xxxx
ADA0
Code 128 disable Code 128 family enable Code 128 - control without transmission of check digit enable EAN 128 - control without transmission of check digit
AI0
AI11
AI21
Code
ISBT 128 enable enable ISBT 128
Code 93 disable Code 93 family enable Code 93 - control without transmission of check digit
EQ1
AI31
AIL xxxx
AK0
AK1
AE0
AE1
AE2
AE3
AE4
AE5
AE6
AE7
xxxx = ASCII numbers that define the code length where:
•
•
First 2 digits = minimum acceptable code length.
Second 2 digits = maximum acceptable code length.
The minimum code length must always be less than or equal to the maximum.
The maximum code length for all codes is 99 characters:
EXAMPLES:
0132 = variable length from 1 to 32 digits in the code.
1010 = 10 digit code length only.
195
POWERSCAN ® D8330/M8300
CODE SELECTION (continued)
DESCRIPTION STRING
Code 11 disable the family
Type C with tx
Type C no tx
Type C and K with tx
Type C and K no tx
AG0
AG1
AG21
AG22
AG31
AG32
AG41
AG42
Code 16K disable
enable
Code 49 disable
enable disable the family GS1 DataBar™
Codes disable GS1 DataBar Expanded Linear and Stacked enable GS1 DataBar Expanded Linear and Stacked disable GS1 DataBar Linear and Stacked enable GS1 DataBar Linear and Stacked
AJ0
AJ1
AM0
AM1
AQ0
AQ10
AQ11
AQ20
AQ21
AQ30
AQ31
RADIO PARAMETERS
DESCRIPTION STRING
Radio Protocol Timeout
Radio RX Timeout enable (seconds) RH02-RH19
RR00-RR99
Power-Off Timeout
Transmission Mode
Beeper Control For Radio Response one-way two-way normal only good decode
RP00-RP99
RI0
RI1
BF0
Single Store only good reception off disable
BF1
BF2
BF3
RO0 one attempt two attempts
RO1
RO2 three attempts four attempts five attempts six attempts
RO3
RO4
RO5
RO6
Find Me seven attempts eight attempts nine attempts disable enable
RO7
RO8
RO9
Bk0
Bk1
196
HOST CONFIGURATION STRINGS
DISPLAY PARAMETERS
DESCRIPTION STRING
Date
Time
Contrast
Font Size
Backlight lighter darker small medium large off
IA ddmmyy
IB hhmm
IC0
IC1
ID0
ID1
ID2
Display-Off Timeout
Display Mode on normal local echo clear display after decode
IE0
IE1
IF a
IG0
IG1
IG2
Keypad disabled keys enable and select KeyID characters
IK0
IK1 bbb
ddmmyy = numbers from the Hex/Numeric Table representing day, month, year
hhmm = numbers from the Hex/Numeric Table representing hour, minutes
a = a number from the Hex/Numeric Table
b = HEX values representing an ASCII character
a = a number in the range 00-99 (sec.) from the Hex/Numeric Table
00 = Timeout disabled (always on).
b = 3 Hex values from 00 to FE representing the left, center and right keys.
FF = KeyID disabled.
197
POWERSCAN ® D8330/M8300
B CODE IDENTIFIER TABLE
2/5 Interleaved
ÌNOÎ
2/5 Industrial
ÌPQÎ
2/5 normal 5 bars
ÌOPÎ
2/5 matrix 3 bars
ÌQRÎ
EAN 8
ÌABÎ
EAN 13
ÌBCÎ
UPC A
ÌCDÎ
UPC E
ÌDEÎ
EAN 8 with 2 ADD ON
ÌJKÎ
EAN 8 with 5 ADD ON
ÌKLÎ
EAN 13 with 2 ADD ON
ÌLMÎ
EAN 13 with 5 ADD ON
ÌMNÎ
198
UPC A with 2 ADD ON
ÌFGÎ
UPC A with 5 ADD ON
ÌGHÎ
UPC E with 5 ADD ON
ÌIJÎ
Code 39 Full ASCII
ÌWXÎ
ABC CODABAR
ÌSTÎ
EAN 128
ÌklÎ
CIP/39
ÌYZÎ
Code 32
ÌXYÎ
CODE IDENTIFIER TABLE
UPC E with 2 ADD ON
ÌHIÎ
Code 39
ÌVWÎ
CODABAR
ÌRSÎ
Code 128
ÌTUÎ
Code 93
ÌUVÎ
CIP/HR
ÌefÎ
ISBT 128
ÌfgÎ
199
POWERSCAN ® D8330/M8300
MSI
ÌZ[Î
Code 11
ÌbcÎ
GS1 DATABAR Expanded Linear and
Stacked
ÌtuÎ
GS1 DATABAR 14 Linear and Stacked
ÌuvÎ
Code 16K
ÌpqÎ
Code 49
ÌqrÎ
GS1 DATABAR Limited
ÌvwÎ
200
C HEX AND NUMERIC TABLE
CHARACTER TO HEX CONVERSION TABLE char hex
SPACE
!
"
#
$
(
)
%
&
'
SYN
ETB
CAN
EM
SUB
ESC
FS
GS
RS
US
FF
CR
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HT
LF
VT
25
26
27
28
29
20
21
22
23
24
1B
1C
1D
1E
1F
16
17
18
19
1A
11
12
13
14
15
0C
0D
0E
0F
10
07
08
09
0A
0B
00
01
02
03
04
05
06
4F
50
51
52
53
54
4A
4B
4C
4D
4E
45
46
47
48
49
40
41
42
43
44
3B
3C
3D
3E
3F
36
37
38
39
3A
31
32
33
34
35
2A
2B
2C
2D
2E
2F
30 char hex char
R
S
T
O
P
Q
J
K
L
M
N
E
F
G
H
I
@
A
B
C
D
;
<
=
>
?
6
7
8
9
:
1
2
3
4
5
*
+
,
-
.
/
0 z
{
|
}
~
DEL u v w x y p q r s t k l m n o f g h i j a b c d e
\
]
^
_
`
U
V
W
X
Y
Z
[
7A
7B
7C
7D
7E
7F
75
76
77
78
79
70
71
72
73
74
6B
6C
6D
6E
6F
66
67
68
69
6A
61
62
63
64
65
5C
5D
5E
5F
60
55
56
57
58
59
5A
5B
HEX AND NUMERIC TABLE
CHARACTER TO HEX CONVERSION TABLE char hex
F10
F11
F12
HOME
END
Pg UP
Pg Down
Ç
È
Å
Æ
ESC
CTRL(Right)
€
€
‚
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
¨
©
¤
¥
¦
§
œ ž
Ÿ
NBSP
¡
¢
£
93
94
95
96
97
98
99
8B
8C
8D
8E
8F
90
91
92
80
81
82
83
84
85
86
87
88
89
8A
A2
A3
A4
A5
A6
A7
A8
A9
9A
9B
9C
9D
9E
9F
A0
A1 char hex
BD
BE
BF
C0
C1
C2
C3
B5
B6
B7
B8
B9
BA
BB
BC
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
CC
CD
CE
CF
D0
D1
D2
D3
C4
C5
C6
C7
C8
C9
CA
CB
D4
Â
Ã
Ä
Å
¾
¿
À
Á
º
»
¼
½
¸
¹
¶
·
³
´
µ
¯
°
±
²
ª
«
¬
-
®
Ò
Ó
Ô
Î
Ï
Ð
Ñ
Ê
Ë
Ì
Í
Æ
Ç
È
É char hex
E8
E9
EA
EB
EC
ED
EE
E0
E1
E2
E3
E4
E5
E6
E7
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
F7
F8
F9
FA
FB
FC
FD
FE
EF
F0
F1
F2
F3
F4
F5
F6
FF
í
î
ï
ð
é
ê
ë
ì
å
æ
ç
è
á
â
ã
ä
Þ
ß
à
Ú
Û
Ü
Ý
Õ
Ö
×
Ø
Ù
õ
ö
÷
ø
ñ
ò
ó
ô
ù
ú
û
ü
ý
Reserved
Reserved
Ì01Î
0
Ì23Î
2
Ì45Î
4
Ì67Î
6
Ì89Î
8
ÌABÎ
A
ÌCDÎ
C
ÌEFÎ
E
HEX / NUMERIC TABLE
Backspace
Ì$%/Î
Cancels an incomplete configuration sequence
Ì12Î
1
Ì34Î
3
Ì56Î
5
Ì78Î
7
Ì9:Î
9
ÌBCÎ
B
ÌDEÎ
D
ÌFGÎ
F
HEX AND NUMERIC TABLE
CHARACTER TO HEX CONVERSION TABLE char hex
F10
F11
F12
HOME
END
Pg UP
Pg Down
Ç
È
Å
Æ
ESC
CTRL(Right)
€
€
‚
ENTER
TAB
F1
F2
F3
F4
F5
F6
F7
F8
F9
¨
©
¤
¥
¦
§
œ ž
Ÿ
NBSP
¡
¢
£
93
94
95
96
97
98
99
8B
8C
8D
8E
8F
90
91
92
80
81
82
83
84
85
86
87
88
89
8A
A2
A3
A4
A5
A6
A7
A8
A9
9A
9B
9C
9D
9E
9F
A0
A1 char hex
BD
BE
BF
C0
C1
C2
C3
B5
B6
B7
B8
B9
BA
BB
BC
AA
AB
AC
AD
AE
AF
B0
B1
B2
B3
B4
CC
CD
CE
CF
D0
D1
D2
D3
C4
C5
C6
C7
C8
C9
CA
CB
D4
Â
Ã
Ä
Å
¾
¿
À
Á
º
»
¼
½
¸
¹
¶
·
³
´
µ
¯
°
±
²
ª
«
¬
-
®
Ò
Ó
Ô
Î
Ï
Ð
Ñ
Ê
Ë
Ì
Í
Æ
Ç
È
É char hex
E8
E9
EA
EB
EC
ED
EE
E0
E1
E2
E3
E4
E5
E6
E7
D5
D6
D7
D8
D9
DA
DB
DC
DD
DE
DF
F7
F8
F9
FA
FB
FC
FD
FE
EF
F0
F1
F2
F3
F4
F5
F6
FF
í
î
ï
ð
é
ê
ë
ì
å
æ
ç
è
á
â
ã
ä
Þ
ß
à
Ú
Û
Ü
Ý
Õ
Ö
×
Ø
Ù
õ
ö
÷
ø
ñ
ò
ó
ô
ù
ú
û
ü
ý
Reserved
Reserved
Ì01Î
0
Ì23Î
2
Ì45Î
4
Ì67Î
6
Ì89Î
8
ÌABÎ
A
ÌCDÎ
C
ÌEFÎ
E
HEX / NUMERIC TABLE
Backspace
Ì$%/Î
Cancels an incomplete configuration sequence
Ì12Î
1
Ì34Î
3
Ì56Î
5
Ì78Î
7
Ì9:Î
9
ÌBCÎ
B
ÌDEÎ
D
ÌFGÎ
F
다운로드
광고