Psion BC-80X0 cradle, PowerScan M8300, D8330 bar code readers Quick Reference Guide
Psion Teklogix PowerScan M8300 is an extraordinary reader that provides many possibilities. With its help, you can easily collect, decode, and transmit bar-coded data. It is a cordless reader that can be paired with BC-80X0 cradles to create a Cordless Reading System. Thanks to its advanced features, it is perfectly suited for single-cradle point-to-point layouts, and it can also be integrated into a fixed scanner application. It has a scan finder button which allows you to verify which scanners are linked to a certain base station and detect a scanner forgotten somewhere.
Annonce
Annonce
BC-80X0 CRADLE
QUICK
REFERENCE
GUIDE
August 23, 2011
PN 8000170.B
ISO 9001 Certified
Quality Management System
Patents
This product is covered by US Pat. 7,948,214 B2.
Additional Patents pending.
©Copyright 2011 by Psion Inc.
2100 Meadowvale Boulevard
Mississauga, Ontario, Canada L5N 7J9 http://www.psion.com
This document and the information it contains is the property of Psion
Inc. This document is not to be used, reproduced or copied, in whole or in part, except for the sole purpose of assisting in proper use of Psion manufactured goods and services by their rightful owners and users.
Any other use of this document is prohibited.
Disclaimer
Every effort has been made to make this material complete, accurate, and up-to-date. In addition, changes are periodically incorporated into new editions of the publication.
Psion Inc. reserves the right to make improvements and/or changes in the product(s) and/or the program(s) described in this document without notice, and shall not be responsible for any damages including, but not limited to, consequential damages, caused by reliance on the material presented.
Psion, the Psion logo, and the names of other products and services provided by Psion are trademarks of Psion Inc.
Windows
™
and the Windows Logo are trademarks or registered trademarks of Microsoft Corporation in the United States and/or other countries.
All trademarks used herein are the property of their respective owners.
Return to Factory Warranty
Psion provides a return to factory warranty on this product for a period of twelve (12) months in accordance with the statement of
Warranty and Product Support provided at: http://www.psion.com/warranty
The warranty on Psion manufactured equipment does not extend to any product that has been tampered with, altered, or repaired by any person other than an employee of an authorized Psion service organization. See Psion terms and conditions of sale for full details.
Important: Psion warranties take effect on the date of shipment.
Updates And Language Availability
Canada/UK/US
The latest drivers and documentation updates for this product are available on the Internet. Log on to: www.psion.com
I
Su Internet sono disponibili le versioni aggiornate di driver e documentazione di questo prodotto. Questo manuale è disponibile anche nella versione italiana. Collegarsi a: www.psion.com
F
Les versions mises à jour de drivers et documentation de ce produit sont disponibles sur Internet. Ce manuel est aussi disponible en version française. Cliquez sur: www.psion.com
D
Im Internet finden Sie die aktuellsten Versionen der Treiber und
Dokumentation für dieses Produkt. Die deutschsprachige Version dieses Handbuches ist auch verfügbar. Adresse: www.psion.com
E
En Internet están disponibles las versiones actualizadas de los drivers y documentación de este producto. También está disponible la versión en español de este manual. Dirección Internet : www.psion.com
Waste Electrical and Electronic
Equipment (WEEE) Directive
2002/96/EC & Waste Batteries Directive
2006/66/EC
This Product, and its accessories, comply with the requirements of the
Waste Electrical and Electronic Equipment (WEEE) Directive 2002/96/
EC. The batteries used in this Product comply with the requirements of
Directive 2006/66/EC.
If your end-of-life Psion product, battery or accessory carries a label as shown here, please contact your local country representative for details on how to arrange recycling. For a list of international subsidiaries, please go to: http://www.psion.com/environmental-compliance.htm
Restriction on Hazardous Substances (RoHS)
Directive 2002/95/EC
What is RoHS?
The European Union has mandated that high environmental standards be met in the design and manufacture of electronic and electrical products sold in Europe, to reduce hazardous substances from entering the environment. The “Restriction on Hazardous Substances Directive (RoHS)” prescribes the maximum trace levels of lead, cadmium, mercury, hexavalent chromium, and flame retardants
PBB and PBDE that may be contained in a product. Only products meeting these high environmental standards may be “placed on the market” in EU member states after July 1, 2006.
RoHS Logo
Although there is no legal requirement to mark RoHS-compliant products, Psion Inc. indicates its compliance with the directive as follows:
The RoHS logo located either on the back of the product or underneath the battery in the battery compartment (or on a related accessory such as the charger or docking station) signifies that the product is RoHS-compliant as per the EU directive. Other than as noted below, a Psion product that does not have an accompanying
RoHS logo signifies that it was placed on the EU market prior to
July 1, 2006, and is thereby exempt from the directive.
Note: Not all accessories or peripherals will have a RoHS logo due to physical space limitations or as a result of their exempt status.
Support Services and Worldwide Offices
Psion provides a complete range of product support services to its customers worldwide. These services include technical support and product repairs.
Technical Support
For technical support in North America:
Call Toll free: +1 800 387 8898 Option 3, or
Direct Dial: +1 905 813 9900 Ext. 1999 Option 3.
For technical support outside of North America, please follow the link for your region on the Psion Community Support website at: http://community.psion.com/support
Product Repairs
For repair service in North America:
Call Toll free: +1 800 387 8898 Option 2, or
Direct Dial: +1 905 813 9900 Ext. 1999 Option 2.
For repair service outside of North America, please contact your local office listed in the following document: http://www.psion.com/documents/com/quickReferenceGuides/
Help_Desk_Contact_Numbers_A4.pdf
Worldwide Offices
Company Headquarters
Psion Inc.
2100 Meadowvale Boulevard
Mississauga, Ontario, Canada L5N 7J9
Tel: +1 905 813 9900
Fax: +1 905 812 6300
E-mail: [email protected]
North American Headquarters & U.S. Service Centre
Psion Corporation
3000 Kustom Drive
Hebron, Kentucky
USA 41048
Tel: +1 859 371 6006
Fax: +1 859 371 6422
E-mail: [email protected]
International Subsidiaries www.psion.com/us/about/contact_psion-offices.htm
Psion S.A.
La Duranne
135 Rue Rene Descartes
BP 421000
13591 Aix-En-Provence
Cedex 3; France
Tel:
Fax:
+33 4 42 90 88 09
+33 4 42 90 88 88
E-mail: [email protected]
Psion Espana S.L.
Plaza de la Pau, s/n Edificio 3, 2º
08940 Cornella de Llobregat,
Barcelona, Spain
+34 902 884 220
+34 934 750 230 [email protected]
NOTES
Using THE BC-80X0
Radio Cradle
The BC-80X0 cradle, paired with one or more PowerScan™ M8300 readers, builds a Cordless Reading System for the collection, decoding and transmission of bar-coded data.
It can be connected to a Host PC through an RS-232, USB, Wedge or
Pen cable and is suited for single-cradle point-to-point layouts. It can also be connected to a C-BOX and therefore integrated into a fixed scanner application.
The BC-8060 models also allow multi-cradle layouts through an RS-485
Network. For this network connection refer to the PowerScan™ D8330/
M8300 User Manual.
The label on the cradle has LED indicators and a scan finder button.
When the button is pressed, the cradle transmits a “broadcast” message. All properly configured scanners (Radio RX Timeout set to keep the radio “awake”) that are linked to that base (through a bind or a join sequence) and within radio range coverage will emit a beep sequence once every 2 seconds for 30 seconds. This functionality is useful to:
• verify which scanners are linked to a certain base station
• detect a scanner forgotten somewhere
The LEDs signal the BC-80X0 status, as described in the following table:
LED
Aux
STATUS
Yellow On = BC-80X0 is powered by an external power supply.
Yellow Blinking = transmission occurs over the Host port.
Host Yellow On = BC-80X0 is powered by the Host.
Yellow Blinking = transmission occurs over the Host port.
Reader Green On = the reader battery is completely charged.
Red On = the reader battery is charging.
Orange Blinking = reader battery fault – replace battery.
Red / Green Alternatively Blinking = charging error - see Ref.
Manual
Spare* Green On = the spare battery is completely charged.
Red On = the spare battery is charging.
Orange Blinking = spare battery fault — replace battery.
Red / Green Alternatively Blinking = charging error — see Ref.
Manual
*This LED refers to the accessory SBS-8000 Spare Battery Slot when mounted to the BC-8060. Not available for BC-8010 models.
Quick Reference Guide 1
PSION
Figure 1. Cradle Overview Figure 2. LEDs
To set up your BC-80X0 cradle you must:
1. Physically install the cradle.
2. Make all system connections.
3. Configure the BC-80X0 cradle.
Installation
Mounting The BC-80X0 Cradle
The cradle package contains the following items:
BC-80X0 1 horizontal base
BC-80X0 Cradle Quick Reference Guide 2 wall-mounting lock hinges
BC-8000 Antenna 4 rubber feet
2 adhesive strips 1 inclined base
The cradle can be mounted for portable or fixed desktop usage, or it can be fixed to a wall. The horizontal base allows portable and fixed desktop usage, while the inclined base provides desktop and wall mounting, allowing for comfortable handling of the PowerScan™ M8300 reader.
2 PowerScan™ M8300
Installation
Figure 3. BC-80X0 Cradle mounted on the Horizontal Base
Figure 4. BC-80X0 Cradle mounted on the Inclined Base
Quick Reference Guide 3
PSION
Desktop Mounting
For desktop usage, you can mount the cradle either on the horizontal base, for reduced overall dimensions, or on the inclined base for a more ergonomic taking out and insertion of the reader onto the cradle.
HORIZONTAL BASE
Mounting
Tabs (4)
Rubber Foot
Seat (4)
Mounting
Holes (2)
Adhesive Strip
Seat (2)
Cable
Channels
Top View Bottom View
INCLINED BASE
Mounting
Tabs (4)
Adhesive
Strip Seat (2)
Rubber Foot
Seat (4)
Cable
Channels
Mounting
Holes (4)
Top View Bottom View
4 PowerScan™ M8300
Desktop Mounting
Portable Desktop Use
1. Correctly position the BC-80X0 onto the base by sliding it along the mounting tabs until aligned.
2. Carefully clean the rubber foot seats of the base to remove any impurities that could reduce adhesion.
3. Remove the protective plastic from the rubber feet and stick them onto the bottom surface of the base.
4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
Fixed Desktop Use
For fixed desktop installation, use the adhesive strips or fixing screws
(not provided) according to your needs.
For mounting with adhesive strips:
1. Position the cradle onto the base by sliding it along the mounting tabs until aligned.
2. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce adhesion.
3. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.
4. Position the cables to be connected to the BC-80X0 cradle along the dedicated channels, as shown in the figures below:
Horizontal Base
Quick Reference Guide
Inclined Base
5
PSION
5. Remove the plastic from the other side of the strips and affix the base to the table.
6. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
For mounting with screws:
1. Position the cables to be connected to the BC-80X0 cradle along the dedicated channels, as shown in the figures below.
2. Position the base on the table and affix it by means of the screws (not provided).
3. Position the cradle on the base by sliding it along the mounting tabs until aligned.
4. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
Wall Mounting
1. Remove the yellow caps and insert the two wall mounting lock hinges provided with your cradle.
2. Position the cables to be connected to the BC-80X0 cradle along the dedicated channels (see figures on the previous page).
6 PowerScan™ M8300
If using the adhesive strips:
3. Carefully clean the adhesive strip seats of the base to remove any impurities that could reduce adhesion.
4. Remove the protective plastic from one side of the adhesive strips and stick them onto the base surface.
5. Remove the plastic from the other side of the strips and affix the base to the wall as indicated in the figure below.
Figure 5. Inclined Base Wall-mounting
Wall Mounting
If using mounting screws:
3. Using the mounting holes on the base as a pattern, mark the wall where you desire to mount the BC-80X0.
4. Drill the appropriate size holes and insert the threaded dowels (not provided) into the holes.
5. Position the base on the wall as indicated in the figure below and affix it by means of the screws (not provided).
6. Attach the cradle on the base by sliding it along the mounting tabs until aligned.
7. If mounting the BC-80X0 cradle, insert the antenna in the appropriate hole on the body of the cradle and screw it clockwise until tight.
Quick Reference Guide 7
PSION
Applying Rapid Point-to-Point Configuration Label (Optional)
A pre-printed bar code label is included in the package for rapid configuration of point-to-point applications. If you wish to use this method, apply this label to the seat provided on the BC-80X0 cradle as shown in the figure. See the
PowerScan™ M8300 Quick Reference
Guide for the configuration procedure.
System Connections
Connections should always be made with power off!
CAUTION
The BC-80X0 cradle provides two interface connectors and a power supply connector as shown in the figure below:
Power
Supply
RS-485
(BC-8060 only)
MULTI-INTERFACE
RS-232, USB, Wedge, PEN
Emulation
The RS-485 Network connection is available only on BC-8060 models.
For details about this type of connection, refer to the PowerScan™
D8330/M8300 User Manual.
To connect the BC-80X0 cradle to the Host through the multi-interface connector, use the cable corresponding to the desired interface type.
8 PowerScan™ M8300
System Connections
Connecting and Disconnecting the BC-80X0 Interface Cable
The BC-80X0 can be connected to a Host by means of an RS-232, USB,
Wedge or Pen cable, which must be simply plugged into the Hos t connector, visible on the front panel of the cradle.
To disconnect the cable, insert a paper clip or other similar object into the hole corresponding to the Host connector on the body of the cradle.
Push down on the clip while unplugging the cable. Refer to the following figures:
Multi-standard interface RS-232, USB,
WEDGE, or PEN Emulation to Host
Connecting/Disconnecting the Cable
Power
RS-232
USB
Quick Reference Guide 9
PSION
WEDGE
PEN
BIND
PowerScan ™ M8300
JOIN
C-BOX
BC-80X0
C-BOX
Scanner
System cables to Host
10 PowerScan™ M8300
BC-80X0 Configuration
BC-80X0 Configuration
BC-80X0 configuration can be performed in two ways:
• by sending configuration strings from the Host PC via the RS-232 or
USB-COM interface
- OR -
• by reading configuration bar codes with the PowerScan™ M reader.
Serial Configuration
By connecting the BC-80X0 to a PC through an RS-232 or USB-COM interface cable it is possible to send configuration strings from the PC to BC-80X0.
Configuration Bar Codes
Once you have performed system connection and PowerScan™ M reader configuration, you can configure the BC-80X0 cradle by reading configuration bar codes. Apply power to the BC-80X0.
For PowerScan™ M configuration, refer to the “PowerScan™ M8300
Quick Reference Guide”.
To configure the BC-80X0 using the PowerScan™ M reader (the one paired to the cradle with the Bind command), follow the procedure according to the interface selected.
Restore Default
Scan the bar code below to restore the BC-80X0 to its default
configuration settings. See "BC-80X0 Default Configuration" on page 17
for more information.
Restore BC-80X0 default
Ì$+RX0$-qÎ
To change the defaults, refer to the "PowerScan
™
D8330/M8300 User
Manual", downloadable from the website.
Quick Reference Guide 11
PSION
Interface Selection
Select and scan one of the interface codes in the following tables, according to your application.
USB INTERFACE SELECTION
USB-KBD
Ì$+UA03$-:Î
USB-KBD – ALT-mode
Ì$+UA04$-@Î
USB-COM*
Ì$+UA02$-4Î
USB-IBM-Hand Held
Ì$+UA01$-.Î
USB-IBM Table top
Ì$+UA00$-(Î
USB KBD-APPLE
*When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation Software. To download the software, refer to PowerScan™ D8330/M8300 User Manual available online at http://www.psion.com.
PEN EMULATION INTERFACE SELECTION
PEN
Ì$+CP6$-BÎ
12 PowerScan™ M8300
Interface Selection
Interface Selection (continued)
RS-232 INTERFACE SELECTION
RS-232 Standard
Ì$+CP0$-$Î
Nixdorf Mode A
Ì$+CM2EC0$->Î
Fujitsu
Ì$+CM1$-ÈÎ
ICL Mode
Ì$+CM0$-ÃÎ
WEDGE INTERFACE SELECTION
Wedge IBM AT or PS/2 PCs
Ì$+CP500$-aÎ
PC Notebook
Ì$+CP505$-ÈÎ
PC Notebook - ALT mode
Ì$+CP508$-2Î
IBM AT - ALT mode
Ì$+CP507$-+Î
Interfaces for IBM XT and IBM Terminals 3151, 347X and 348X can be selected from the PowerScan™ D8330/M8300 User Manual available online at http://www.psion.com
.
Quick Reference Guide 13
PSION
Keyboard Nationality
USB-KBD and Wedge users should select one of the following wedge keyboard nationality codes according to your keyboard.
Belge
Ì$+FJ7$-8Î
Deutsch
Ì$+FJ3$-$Î
English
Ì$+FJ4$-)Î
Español
Ì$+FJ6$-3Î
Français
Ì$+FJ2$-ÊÎ
Italiano
Ì$+FJ1$-ÅÎ
Svenskt
Ì$+FJ5$-.Î
USA (Default)
Ì$+FJ0$-|Î
14 PowerScan™ M8300
Keyboard Nationality
The following Keyboard Nationality selections are only valid for IBM AT compatible PCs:
Japanese
Ì$+FJ8$-=Î
Russian (Latin)
Ì$+FJ9$-BÎ
Russian (Cyrillic)
Ì$+FJA$-jÎ
Hungarian
Ì$+FJB$-oÎ
Slovenian, Croatian, Serbian (Latin)
Ì$+FJC$-tÎ
Romanian
Ì$+FJD$-yÎ
Czech Republic
Ì$+FJE$-~Î
Quick Reference Guide 15
Data Format Terminators
For your convenience, some common Terminators are given below. For other Header/Terminators selections, Data Format and Advanced Data
Format parameters see the PowerScan
™
D8330/M8300 User Manual.
CR-LF
Ì$+EA120D0A$-ÃÎ
Enter
Ì$+EA1183$-0Î
Tab
Ì$+EA1184$-8Î
None
Ì$+EA10$-dÎ
Quick Reference Guide 16
BC-80X0 Default Configuration
BC-80X0 Default Configuration
USB-KBD DEFAULT SETTINGS
USA keyboard, FIFO enabled, inter-character and inter-code delays disabled, USB keyboard speed normal.
DATA FORMAT : code identifier disabled, code length not transmitted, character replacement disabled, reader and cradle address stamping disabled, reader and cradle address delimiter disabled, time stamping disabled, time stamping delimiter disabled, no header, terminator =
ENTER.
RS-232 DEFAULT SETTINGS
9600 baud, no parity, 8 data bits, 1 stop bit, no handshaking, ack/nack protocol disabled, FIFO enabled, delay disabled, 5 sec. rx timeout
DATA FORMAT : code identifier disabled, code length not transmitted, character replacement disabled, reader and cradle address stamping disabled, reader and cradle address delimiter disabled, time stamping disabled, time stamping delimiter disabled, no header, terminator = CR-
LF.
WEDGE DEFAULT SETTINGS
USA keyboard, Caps Lock off, Caps Lock Auto-Recognition enabled, num lock unchanged, inter-character and intercode delay disabled, control character emulation = ctrl+shift+key.
DATA FORMAT : code identifier disabled, code length not transmitted, character replacement disabled, reader and cradle address stamping disabled, reader and cradle address delimiter disabled, time stamping disabled, time stamping delimiter disabled, no header, terminator =
ENTER.
PEN DEFAULT SETTINGS
Interpret operating mode, conversion to code 39, output level normal, idle level normal, minimum output pulse 600 s, overflow medium, interblock delay disabled.
NETWORK PARAMETERS
RS-485 network disabled (for BC-8000 only).
Quick Reference Guide 17
PSION
Operating Test
Read the TEST codes below.
EAN-8
1 2 3 4 5 6 7 0
EAN-13
1 2 3 4 5 6 7 0 0 0 9 9 2
CODE 39 (NORMAL)
Code 39 (Normal)
1 7 1 6 2
CODE 128 t e s t
INTERLEAVED 2 OF 5
0 1 2 3 4 5 6 7 8 4
YOUR SYSTEM IS NOW READY TO READ CODES AND SEND DATA
TO THE HOST.
18 PowerScan™ M8300
Technical Features
Technical Features
BC-80X0
Electrical Features
Supply Voltage
External Power
Host Power
Power Consumption
External Power
Host Power
10..30 VDC
5 VDC ±10%
Indicators max. 10 W (charging) * max. 500 mA (charging)
Ext. Power/Data yellow LED
Host Power/Data yellow LED
Reader batt. state green/red LED
Spare batt. state green/red LED (BC-8060 only) beeper
Time of Recharge
External Power
Host Power
Radio Features max. 4 hours with 2150 mAh Li-Ion battery max. 10 hours with 2150 mAh Li-Ion battery
Radio frequency
Bit Rate
Range (in open air)
Environmental Features
European Models USA Models
433.92 MHz 910 MHz
19200 baud
50 m
36800 baud
30 m
Working Temperature
Radio
Battery Charging
Storage Temperature
Humidity
Protection Class
Mechanical Features
Weight without mounting base
Dimensions (without antenna)
Material
-20° to +50 °C / -4° to +122 °F
0° to +40 °C / +32° to +104 °F
-20° to +70 °C / -4° to +158 °F
90 % non condensing
IP40 about 380 g / 13.4 oz
240 x 108 x 95 mm / 9.44 x 4.25 x 3.74 in
ABS
*Having a switching regulator inside, the BC-80X0 draws the same power, regardless of the supply voltage. In other words, as the input voltage increases the current drawn decreases.
System Configuration
Max number of devices per base station
Max number of devices in the same reading area
Max number of base stations in network
BC-80X0
32
STARGATE™
255
2000
16 (including cradle Master)
Quick Reference Guide 19
dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el
BC-80X0, RF Base Charger
Psion Inc.
2100 Meadowvale Boulevard,
Mississauga, Ontario, Canada L5N 7J9 http://www.psion.com
e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos
08 sono conformi alla Direttiva del Consiglio Europeo sottoelencata: are in conformity with the requirements of the European Council Directive listed below: sont conformes aux spécifications de la Directive de l'Union Européenne ci-dessous: der nachstehenden angeführten Direktive des Europäischen Rats entsprechen: cumple con los requisitos de la Directiva del Consejo Europeo, según la lista siguiente:
1999/5/EEC R&TTE
Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti:
This declaration is based upon compliance of the products to the following standards:
Cette déclaration repose sur la conformité des produits aux normes suivantes:
Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht:
Esta declaración se basa en el cumplimiento de los productos con las siguientes normas:
ETSI EN 301 489-3 v1.4.1, August 2002: E LECTRO M AGNETIC C OMPATIBILITY AND R ADIO
SPECTRUM M ATTERS (ERM); E LECTRO M AGNETIC
C OMPATIBILITY (EMC) STANDARD FOR RADIO
EQUIPMENT AND SERVICES ; P ART 3: S PECIFIC
CONDITIONS FOR S HORT -R ANGE D EVICES (SRD)
OPERATING ON FREQUENCIES BETWEEN 9 K H Z AND
40 GH Z
ETSI EN 300 220-3 v1.1.1, September
2000:
E LECTROMAGNETIC COMPATIBILITY AND R ADIO
SPECTRUM M ATTERS (ERM); S HORT R ANGE
D EVICES (SRD); R ADIO EQUIPMENT TO BE USED IN
THE 25 MH Z TO 1000 MH Z FREQUENCY RANGE
WITH POWER LEVELS RANGING UP TO 500 M W;
P ART 3: H ARMONIZED EN COVERING ESSENTIAL
REQUIREMENTS UNDER ARTICLE 3.2 OF THE R&TTE
D
IRECTIVE
EN 60950-1, December 2001: I NFORMATION TECHNOLOGY EQUIPMENT – S AFETY –
P
ART
1: G
ENERAL REQUIREMENTS
April 16, 2008
Download
Annonce