Amcor AC 706AM is a portable air conditioner with a cooling capacity of 7,000 BTU/h. It features an innovative AutoDrain NanoMist Technology™ which uses evaporative technology to cool the unit internally, making it run more efficiently. The unit also has a built-in dehumidifier with a capacity of 42 - 50 pints per 24 hours. It has two fan speeds, a remote control, and a programmable timer. The unit can be easily moved from room to room and is ideal for spot cooling in small to medium-sized rooms.
advertisement
Owner’s
Manual
Portable Air Conditioner
Series
It is important that you read these instructions before using your new purchase and we strongly recommend that you keep them in a safe place for future reference.
Innovative AutoDrain NanoMist Technology
™
Patent Pending
Table of Contents
Thank You ……………………………………………………… 1
Safety Instructions …………………………………………… 1-2
Specifi cations …………………………………………………… 3
Parts …………………………………………………………… 4
AutoDrain NanoMist Technology ™ Assembly …………………… 5
Positioning ……………………………………………………… 6
Operation …………………………………………………… 7-8
Emptying the Water Container ………………………………… 9
Cleaning …………………………………………………………10
Installation of the Filters …………………………………………10
Storage……………………………………………………………11
Troubleshooting …………………………………………………12
Limited Warranty …………………………………………………14
Thank You!
Thank you for purchasing an AMCOR Portable Air Conditioner.
AMCOR is a leading brand in indoor air treatment. We would like you to enjoy the many benefi ts this unit offers, so please read this manual carefully and take full advantage of the many advanced features that your AMCOR Air Conditioner offers you.
AMCOR has specialized in complete indoor environment control, manufacturing world-class heaters, air conditioners, dehumidifi ers and air purifi ers with innovative technology.
In designing these advanced products, we have listened carefully to our customers and have passed their views on to our research and development laboratories.
We wish you many years of enjoyable use.
After reading this manual, please keep it in a safe place for future reference.
Read this entire instruction manual before use.
Please keep your receipt. Your receipt is your Proof of Purchase and is necessary for warranty service.
Safety Instructions
IMPORTANT!
• The unit is designed for indoor operation.
• Rating: This unit must be connected to a 115V/60Hz grounded outlet.
• The installation must be in accordance with regulations of the country where the unit is used.
If you are in any doubt about the electrical installation, have it checked and if necessary modifi ed by a qualifi ed electrician.
• The air conditioner is safe. However, as with other electrical appliances, use it with care.
• Keep out of the reach of children.
• Do not clean the unit by spraying it or immersing it in water.
• Do not insert any object into the openings of the unit.
• Disconnect the unit from the outlet before cleaning the unit or any of its components.
• Never connect the unit to an electrical outlet using an extension cord.
If an outlet is not available, one should be installed by a licensed electrician.
WARNING!
• Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges.
• A damaged supply cord should be replaced by the manufacturer, its service agent or a qualifi ed person
in order to avoid a hazard.
• Any service other than regular cleaning or fi lter replacement should be performed by an authorized
service representative. Failure to do so could result in a loss of warranty.
1
Do not use your air conditioner:
Safety
If the power cable wires are frayed or cut
When small children may be left unattended
On a slope or uneven surface Close to a heat source
This products is not made for
DIY repair
If there is a risk of liquid falling on the unit
Inside unit exposed to the weather outdoors
In a permanent very humid environment
If an extension lead may become overloaded
Where the power cable may be damaged
Where it may be damaged by chemicals
Where there is a risk of interference by foreign objects
Reminder:
Waste electrical products must not be disposed of with household waste.
This product should be taken to our local recycling center for safe treatment.
2
Specifi cations
Model
Cooling Capacity
Power Supply
Power Consumption
Current
Dehumidification
Refrigerant
Compressor
Fan Speeds
Thermostat
Timer
Dimensions
Weight
NanoMax
™
Series
7,000 - 12,000 BTU/h
115V / 60Hz
680 - 830 watts
6.8 - 7.9A
42 - 50 Pints / 24h
R22
Rotary
2
62º - 90º F
1 - 12 Hours
12"W x 15"D x 30"H
50 lbs.
Subject to modifications without prior notice.
Please refer to the rating label for greater precision.
3
12
16
10
Parts
13
11
15
14
1. Handle
2. Control panel
3. Air outlet
4. Air inlet with filter
5. Exhaust hose with adapter
6. Power cord hanger
7. Exhaust air outlet
8. Water stopper (plug inside)
9. Casters
10. Adjustable Window Slide Bar
11. Flexible Drain Hose
12. Exhaust hose
13. IR Ergonomic Remote Control
14. Exhaust Hose Window
Slide Bar Connector
15. Insulation tape
4
4
5
6
7
4
8
9
1
2
3
1
3
5
7
AutoDrain NanoMist Technology
™
Assembly
Stretch end of the hose slightly.
Attach Window
Slide Bar
Connector to
Exhaust Hose by twisting as shown .
2
Connect the female half of the quick connector at the end of the spiral water pipe to the male part in the hot air outlet pipe.
4
Stretch end of the hose slightly.
Assemble the hot air hose on the unit by screwing in clockwise.
6
Unfold fl exible hose with attached hose adapter connector, and snap into
Window Slide Bar.
8
Put spiral water pipe into hot air fl exible hose.
Turn the connector
90º clockwise until it is locked
in place.
Clip on the water atomizer at the end of the spiral pipe to the holder.
Only
Required For
Disassembly.
In order to unlock the quick connector, push the tab and turn the connector counter clockwise.
5
Positioning
This unit can easily be moved from one room to another. In doing so keep this in mind:
• The air conditioner must stand upright on an even surface.
• Do not position near bath, sink, or other permanent wet or damp area.
• Keep unit at least 18" from wall, curtains, draperies, to insure adequate air circulation.
2 a
1
2 b
Installing Exhaust Hose to Window Slide Bar
After assembling Innovative AutoDrain NanoMist Technology ™ per instructions on page 5, make sure hose is fi rmly attached to oval connecter that fi ts into window slide bar.
Snap hose connecter into window slide bar opening. See Illustration 1.
Extend window slide bar to fi t your window opening, either vertical or horizontal, depending on how the window opens. See Illustrations 2a-2b.
Important
The fl exible exhaust hose can be extended from 12" to 60" for mounting.
This length has been designed especially according to the specifi cations of the air conditioner.
Do not use an extension or exchange for a different hose as that may lead to malfunctioning.
The exhaust air must fl ow freely, any blockage can lead to overheating of the air conditioner.
Take care to prevent any kink or bend in the exhaust hose.
6
Operation
COOL
FAN
MODE
TIMER
TIMER
UP DOWN
LOW
HIGH
FAN
SPEED
WATER FULL
COMP.
ON/OFF
3 2 5 4 1
1. ON/OFF
Press the
ON
/
OFF
-button to switch the unit on or off.
2. Setting the Timer
Press the
TIMER
button, which will start the timer counter function.
Each press of the timer button will advance the timer setting by 1 hour, for setting
1-12 hours. If you pass the desired hour setting, you must advance the numbers completely through 12, to start timer count from 1. When set, the
TIMER LED
will light up.
When the set hours have elapsed, the unit will turn off automatically.
The display will show the hour(s) remaining when you press the
TIMER
button.
By pressing the
TIMER
button but without turning the unit on, you can pre-set in how many hour(s) the unit will switch on automatically.
3. Setting the Operating Mode
Select the required operating mode:
COOL
,
FAN
, or
AUTO
. The corresponding
LED
will lit.
In
AUTO
mode the unit will select cooling or fan depending on the ambient temperature.
4. Fan Speed
Select the fan speed, the corresponding
LED
will lit:
LOW
or
HIGH
.
5. Increase UP or DOWN
When the unit is ON, the display always shows the room temperature.
Press button UP or DOWN to see the current set temperature and adjust if necessary, in the range of 62ºF to 90ºF. After 8 seconds, the room temperature will be displayed.
Warning lights COMPRESSOR and WATER FULL
When the water container is full, the unit automatically stops, the warning light
WATER FULL will fl ash to signal that the container must be emptied (see page 9, “Emptying The
Water Container”).
When the unit is cooling, the compressor light will be on. If this light is off further cooling is not needed at this time, or the compressor may be de-icing its coils.
The fan can still be on.
7
Operation
Remote Control
The air conditioner responds to all signals that are sent by the remote control. Two AAA-batteries are required to use the remote control.
Point the remote control hand set towards the control panel of the unit and press the relevant button, the red
LED
on the hand set will fl ash whenever a button is pressed.
Note: the air fl ow direction can not be adjusted with the remote control.
Air Flow
Adjust the left-right direction of the outfl owing air by turning the roller on the front of the air outlet grill.
Adjust the up/down air fl ow by rotating the air outlet grill.
Important:
• The compressor will start approximately 3 minutes after the
unit is turned on (this will help prolong the life of the
compressor). After switching the unit off, please wait at least
3 minutes before turning the unit back on.
• The compressor will switch off when the room temperature
is lower than the set temperature. The fan will however
continue to work. When ambient temperature rises above
the set temperature, the cooling will resume.
8
Emptying The Water Container
This portable AC features the
Innovative AutoDrain NanoMist Technology ™
Very little excess water should accumulate. During the process of cooling, some of the water accumulated is actually used to cool the unit internally, making it run more effi ciently. Both this evaporative technology and Innovative AutoDrain NanoMist Technology™ are features not found in most portable air conditioners.
Switch off the unit and remove the plug from the outlet.
• Position a fl at container or dish on the fl oor under the drain hole.
Do not allow the water to drip continuously into the
container as it might easily overfl ow.
• Remove the drain knob.
• Remove the rubber plug, the water will fl ow in the
container. When this is nearly full, replace the plug to
stop the water fl ow and empty it. Repeat this process
until all water has been removed.
• Replace the rubber plug into the drain hole fi rmly,
the
FULL LED
should not fl ash any longer.
• Replace the drain knob.
Rubber plug Drain knob
9
Cleaning
Always unplug the unit from the power supply (wall outlet) before beginning the cleaning.
Housing
Use a soft, damp cloth to wipe the body clean. Never use strong chemicals, oil-based products, detergents, chemically treated cloths or other cleaning solutions. These could possibly damage the housing.
Filter
Use a vacuum cleaner or tap the fi lter lightly to remove loose dust and dirt from the fi lters and then rinse them thoroughly under running water (not warmer than 104°F).
Dry thoroughly before replacing.
Notice! Never operate the air conditioner without the fi lters.
Installation of Carbon Filter
It is recommended to replace an active carbon fi lter at the start of the season.
• Remove the top fi lter frame from
the unit by pulling it out.
• Separate the fi xer from
the fi lter frame.
• Insert the active carbon fi lter into the
fi lter frame, underneath the tabs.
• Re-fi t the fi lter frame inside the unit.
10
Storage
This Portable AC features the
Innovative AutoDrain NanoMist Technology ™ .
Very little excess water should accumulate. If any water accumulates, refer to “Emptying the Water Container” on page 9.
• Drain the condensed water (if any) completely.
• Clean or change the fi lter.
• Put the unit on a warm day in fan mode for a couple of hours to
ensure that the inside can dry out completely.
• Store the power cable as shown, protect the unit against dust (put
back into its original carton) and store in a dry place not accessible
• To protect the unit against dust, store in a dry place not accessible
• Do not stock heavy objects on top of the unit.
11
Troubleshooting
Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property.
Problem Cause
The air conditioner does not function.*
The air conditioner does not seem to perform.
No power supply. Make sure the green light on the plug is lit.
Is the power light fl ashing?
Is the water full LED lit?
The unit is in direct sunlight.
Windows or doors open, many people or a heat source in the room.
The filter is dirty.
Air inlet or air outlet blocked.
Room temperature lower than the selected value.
The unit is noisy.
Unit stands uneven.
The compressor does not work.
The remote control does not function.
The overheat protection may be activated.
Distance too great.
Remote control signal not detected by the control panel.
The batteries are drained.
Solution
Connect to a functioning outlet and switch on.
Empty the drain pan.
Close curtains.
Close doors and windows, place an extra air conditioner.
Clean or replace the fi lter.
Remove the blockage.
Change temperature selection.
Set at the lowest possible setting: 62°F.
Place on an even, solid surface (less vibrations).
Wait 30 minutes until the temperature has decreased, then turn on the unit again.
Make sure the remote control is correctly aimed at the control panel.
Replace the batteries.
* If you plug in the Air Conditioner, and there is no green light on the plug, press the reset button on the LCDI plug. The green light should be lit, indicating that the air conditioner is getting power from the electrical outlet.
If the plug continues to trip (which is a USA national safety standard feature) and the green light goes off, the cord may be damaged preventing you from resetting the unit. For your safety, contact a licensed electrician.
RESET
TEST
Reset Button
Test Button
Green Light
12
Don’t forget to register your Amcor purchase online, and view our broad selection of innovative products.
www.amcorgroupusa.com
13
One Year Limited Warranty
(5 years for Compressor Only
)
Amcor, Inc. (“Amcor”) warrants the original retail purchaser (“Purchaser”) purchasing in the United
States that the Amcor product with which this warranty is enclosed is free from defects in materials and workmanship.
Amcor’s sole obligation under this warranty is to replace, or at Amcor’s discretion, to repair, free of charge, all defective parts, for a period of one (1) year from date of original purchase. (5 years for
Compressor Only) ANY IMPLIED WARRANTY OF MERCHANTABILITY IS SIMILARLY LIMITED
TO ONE (1) YEAR -(5 years for Compressor Only) FROM DATE OF ORIGINAL PURCHASE AND
NO ACTION BASED UPON ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OTHER-
WISE MAY BE COMMENCED AFTER EXPIRATION OF ONE (1) YEAR -(5 years for Compressor
Only) FROM DATE OF ORIGINAL RETAIL PURCHASE. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation -(5 years for Compressor Only) may not apply to you.
The provisions of this warranty shall not apply to any product which in Amcor’s judgment has been
(1) subject to misuse or neglect. (2) damaged in an accident. (3) used for a purpose for which it was not designed, or (4) repaired or altered in any way that adversely affected its performance or reli-ability.
To obtain warranty service, the defective product or part must be shipped or delivered to: Amcor’s authorized service center. All postage, insurance and shipping charges are the responsibility of the
Purchaser and are not included in this warranty.
AMCOR NEITHER ASSUMES NOR AUTHORIZES ANY PERSON TO ASSUME FOR IT ANY
OTHER ( LIABILITY IN CONNECTION WITH ITS PRODUCTS, THERE ARE NO WARRANTIES
WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. NO RESPONSIBILITY
IS ASSUMED FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES THAT MAY RESULT FROM
THE USE OF AN AMCOR PRODUCT, NOR FOR THE DAMAGES DUE TO ACCIDENT, ABUSE,
LACK OF RESPONSIBLE CARE, THE AFFIXING OF ANY UNAUTHORIZED ATTACHMENT,
LOSS OF PARTS, OR USE AT A VOLTAGE OTHER THAN SPECIFIED. Some states do not allow the exclusion of limitation of incidental or consequential damages, so these limitations may not apply to you.
Amcor disclaims all liabilities for defects or damages caused by use of replacement parts obtained from or by service at any service center other than Amcor’s authorized service center.
This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state.
Product: AMCOR Portable Air Conditioner Model: NanoMax ™ Series
Date Purchased:__________________________________ Production Code:________
QUESTIONS? Call 866-361-2233
www.amcorgroupusa.com
Dear Customer: Please keep this warranty for your record.
DO NOT return it.
14
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement