Wegener iPUMP6400 User manual
Below you will find brief information for Professional Media Server iPUMP 6400. The iPump6400 is an integrated, digital satellite receiver, decoder, and media server designed to provide the most cost effective method of delivering and storing digital content for broadcast, cable, and business operations. It is a key part of the Wegener Communications Digital Media Delivery System which combines secure MPEG and IP digital transmission with media management and server storage.
Advertisement
Advertisement
iPUMP6400
Professional Media Server
User’s Manual
iPump6400 User’s Manual
Data, drawings, and other material contained herein are proprietary to Wegener
Communications, Inc., and may not be reproduced or duplicated in any form without the prior written permission of Wegener Communications, Inc.
The information contained herein is subject to change without notice.
Revisions may be issued to advise of such changes and/or additions.
WEGENER
UNITY·IP
, COMPEL CONTROL
, and iPUMP
, MEDIAPLAN
, ENVOY, UNITY
are trademarks of Wegener Communications, Inc.
,
All other trademarks are the property of their respective owners.
2004 Wegener Communications, Inc. All rights reserved.
Portions copyright 1992-2001 FairCom Corporation. "FairCom" and "c-tree plus" are trademarks of FairCom Corporation and are registered in the United
States and other countries. All Rights Reserved.
Correspondence regarding this publication,
800009-01 Revision B
Second Edition: May 2004 should be forwarded to:
Wegener Communications, Inc.
Technology Park/Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Phone: 770-814-4000
Fax: 770-623-0698
The Wegener iPump6400 is approved under FCC Part 15B Class A, UL1950,
CSA, and CE.
800009-01 Rev. B 2 wegener.com
wegener.com
Table of Contents
iPump6400 User’s Manual
Chapter 1 General Information
1.2 iPump6400 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Functional Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Status Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Live Program Play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Record Program to File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Play Recorded Program File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
File Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Stream Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Scheduled Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
File Downloads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Files Served to LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Compel Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
HTML Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 1 iPump6400 Options Key . . . . . . . . . . . . . . . . . . . . . . . . . . 12
1.3 iPump6400 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 2 Technical Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . 14
1.5 Glossary of Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 3 Glossary of Terms. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Chapter 2 Installation
2.1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.2 Location and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
2.3 iPump6400 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Table 4 iPump6400 Connector Details . . . . . . . . . . . . . . . . . . . . . . 23
Alarm Connector Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Table 5 iPump6400 Alarm Connector Pin Functions . . . . . . . . . . 24
Ethernet/LAN Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Table 6 iPump6400 LAN Connector Pin Functions . . . . . . . . . . . 24
Optional Decoder with Digital Output . . . . . . . . . . . . . . . . . . . . . . . 25
Table 7 Digital Output Decoder Connectors . . . . . . . . . . . . . . . . . 25
Table 8 Balanced Analog and AES/EBU Digital Audio Connector Pin
Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Multiswitch Connection Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Table 9 RF Port Selection Signals. . . . . . . . . . . . . . . . . . . . . . . . . . 27
3 800009-01 Rev. B
iPump6400 User’s Manual
Chapter 3 Operation
3.1 Operation Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.2 Front-panel Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . 30
Liquid-crystal Display(LCD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Table 10LED Indicator Descriptions . . . . . . . . . . . . . . . . . . . . . . . 31
3.3 Startup/Shutdown Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Normal Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Web Browser Operations Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Normal Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
3.4 Front-panel Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
LCD Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Selectable Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Table 11iPump6400 Preconfigured RF Settings. . . . . . . . . . . . . . 39
Current Channel Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
LNB Type Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
LNB DC Power Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Date/Time Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Unit Label Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
3.6 iPump6400 Operations by Function . . . . . . . . . . . . . . . . . . . . . . . . . 46
Monitor iPump6400 Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Live Program Play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Record Program to File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Play Recorded Program File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
File Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
File Streaming and Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Scheduled Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Playlist Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
iPump6400 Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
3.7 Unit Software Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Chapter 4 Maintenance and Troubleshooting
No functions at all . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Trouble using browser interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Table 12LED Indicator Descriptions . . . . . . . . . . . . . . . . . . . . . . . 60
800009-01 Rev. B 4 wegener.com
iPump6400 User’s Manual
Chapter 5 Customer Service
Index
wegener.com
5 800009-01 Rev. B
iPump6400 User’s Manual
This page intentionally blank
800009-01 Rev. B 6 wegener.com
Chapter 1 General Information
1.1 Manual Overview
This manual provides instructions and reference information for the proper installation and operation of the Wegener iPump6400 Professional Media
Server, referred to throughout the manual as the iPump6400.
The manual is divided into the following chapters:
1 General Information - a description of your iPump6400, its functions and specifications, and a glossary of terms.
2 Installation - procedures and information for the correct and safe instal-
lation of your iPump6400.
3 Operation - instructions on starting and operating your iPump6400.
4 Maintenance and Troubleshooting - information on maintaining your
iPump6400 and resolving possible operating difficulties.
5 Customer Service - Our warranty and information on obtaining help.
An Index of keywords is also provided to help you quickly locate needed
information.
Please email any suggestions or comments concerning this manual to [email protected]. If you prefer to post through the mail, please send your comments to the address below. If you have substantial or complex changes to recommend, our preference is that you copy the page(s) in question, mark your changes on that copy, and fax or mail us the copy. We always appreciate constructive criticism.
Our Address:
Attn: Manuals
Wegener Communications, Inc.
Technology Park / Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Our Fax Number:(770) 497-0411 wegener.com
7 800009-01 Rev. B
iPump6400 User’s Manual
1.2 iPump6400 Overview
The Wegener iPump6400 is an integrated, digital satellite receiver, decoder, and media server designed to provide the most cost effective method of delivering and storing digital content for broadcast, cable, and business operations.
The iPump6400 is a key part of the Wegener Communications Digital Media
Delivery System which combines secure MPEG and IP digital transmission with media management and server storage. At a given time, up to 260 hours of media content can be stored on a single iPump6400 (with optional, large disk capacity) and served out via Ethernet according to current need or predetermined schedules.
Physical
Description
Functional
Description
With the iPump6400, you can receive, decode, and play out broadcast-quality transmissions while at the same time receiving from satellite and recording multiple programs or IP data files. Combined with our Compel MediaPlan software, the iPump6400 can also place spot segments into real-time or recorded programs and can schedule playback of custom sequences of live and recorded content.
The iPump6400 is housed in a standard, 2 RU, rack-mountable chassis. Its front panel provides a user interface through an LCD and six push buttons (see
Figure 3.1 iPump6400 Front Panel on page 30). The rear panel holds the
power switch and the ports that allow connection to power, incoming signal, and peripheral devices.
Your iPump6400 can perform the following functions:
Status Monitoring
Front-panel and web browser interface screens allow real-time monitoring of iPump6400 activity, settings, and signal characteristics.
Live Program Play
The iPump6400 decodes an incoming DVB MPEG program from the received satellite signal. It decrypts and decodes the audio and/or video from the selected program through analog or digital output ports to your monitor or transmission equipment. The incoming content may be either a "classical"
DVB program or an IP multicast stream. RF and decoder settings are selected by the user. Two live programs from the same DVB carrier may be played simultaneously by iPump6400s that have the optional second decoder.
Record Program to File
The iPump6400 can simultaneously record up to three separate multiplexed programs (either "classical" DVB or IP multicast stream) from the incoming stream including any that are played live to the decoder(s). The user selects the
800009-01 Rev. B 8 wegener.com
wegener.com
iPump6400 User’s Manual programs and enters a file name, audio setting, and a recording time (duration) for each. Files are recorded to disk in the iPump6400 for later play-out or downloading. Up to 40 GB of storage (up to 43.3 hours of programming depending on data rate) is available on standard iPump6400s and up to 240 GB
on optional, extended-storage iPump6400s (see Disk Storage Capacity).
Record and play functions can be used in such applications as "tape delay"/ time zone shifting, "spot" localization of commercials, and corporate training media distribution.
Play Recorded Program File
The iPump6400 plays out the selected, stored program files to the connected audio and video monitors. File playing may be initiated by a predetermined schedule via Compel or by a schedule stored internally to the iPump6400. The user may also command playing of files directly from a web browser or from the front panel. Two recorded programs (or one recorded and one live) may be played simultaneously on iPump6400s with an optional second decoder.
File Management
Compel users can rename or delete files stored on the iPump6400 and organize them into directories or folders. Renaming and deleting files may also be performed through a web browser connected to the iPump6400 over a LAN.
Playlists
Sequences of programs called Playlists can be created and stored on the iPump6400 by the user (locally or by COMPEL). Up to 100 Playlists can be stored in nonvolatile memory and played back with no interruption between programs. Settings can be made to repeat the playlist indefinitely, complete the playlist and repeat only the last program indefinitely, or complete the playlist and simply return the decoder to its previous state.
Routing
The iPump6400 can serve as a satellite-to-LAN IP router. Both unicast and multicast IP traffic is supported. Multicast traffic can include, for example,
MPEG video streaming data. The IGMP protocol is followed for multicast traffic.
Stream Creation
The iPump6400 can create IP multicast video streams and present them on the
LAN for use by other equipment. The source of the video stream may be either a prerecorded or downloaded file or a "classical" DVB program.
9
iPump6400 User’s Manual
The iPump6400 can also multicast previously-stored streams to the LAN. See
Figure 1.1 iPump6400 Routing for an illustration of iPump6400 routing
paths.
Figure 1.1 iPump6400 Routing
Scheduled Operation
Schedules of record, play, and other operations for automatic execution by the iPump6400 may be set up using the Compel network and may be viewed from the web browser interface. (Schedule operations support wild cards and ranges in day, date, and time fields for repetitive events.)
File Downloads
The iPump6400 accepts files downloaded from the satellite link via Compel’s
Assured File Delivery package. Application software and other files may also be downloaded. Up to five downloads may be performed simultaneously up to an aggregate data rate of 25 Mbps.
The iPump6400's file download and record functions may be used to load the unit with content for playout (according to a pre-arranged schedule if desired) at any time. This can be particularly useful in applications with extended or continuous playout needs and limited satellite operating times.
800009-01 Rev. B 10 wegener.com
iPump6400
Options
iPump6400 User’s Manual
Files Served to LAN
Users sharing a LAN with the iPump6400 may download stored files from the iPump6400 to their local workstation or server using FTP or SMB protocol.
Compel Control iPump6400 operation may be controlled remotely by a Compel network. Compel conditional access controls which iPump6400s may access the satellite’s material and prevents access by any other receive equipment. Local control of the unit may be disabled for exclusive control by Compel. The iPump6400 always follows the most recent command received and does not prioritize commands based on origination from the front panel, web browser interface, or
Compel network.
HTML Control
Control of the iPump6400 is available from any web browser on the LAN to which it is connected or via the internet if desired. The IP address and subnet mask can be displayed and changed at the iPump6400 front panel.
Contact Closure/Alarms
The iPump6400 provides a contact closure through a rear-panel connector whenever the unit enters an alarm condition. An additional user relay is also available. The iPump6400 can also sense a contact closure input. Using Compel, file playouts can be triggered by local closure of this input.
The iPump6400 Professional Media Server is available in several configurations to meet specific applications. Input type, decoder type, disk storage capacity, Conditional Access, and the presence of a second decoder can be varied to create models best suited for your specific needs.
wegener.com
11
iPump6400 User’s Manual
The iPump6400 model number is structured as follows to describe the options on each iPump6400:
IP - ABC - D - EF - G - HH - JKK
Table 1: iPump6400 Options Key
Model Number
Position
IP
A
B
C
D
E
F
G
HH
Option Name Designator Description
This prefix simply indicates that the unit is an iPump.
First Decoder Type
(top slot)
0 - No decoder
1 - Basic decoder
2 - professional 4:2:0 decoder with analog outputs
3 - professional 4:2:2 decoder with analog outputs
4 - professional 4:2:2 decoder with digital outputs
5 - professional audio output
6 - professional 4:2:0 decoder with analog outputs and channel 3-4 modulator connector
Second Decoder Type
(middle slot)
Input Type
(bottom slot)
Disk Storage Capacity
0 - No second decoder
1 - Basic decoder
2 - professional 4:2:0 decoder with analog outputs
3 - professional 4:2:2 decoder with analog outputs
4 - professional 4:2:2 decoder with digital outputs
5 - professional audio output
6 - professional 4:2:0 decoder with analog outputs and channel 3-4 modulator connector
1 - DVB RF Input
2 - ASI Input
1 - 40 Gigabytes
2 - 80 Gigabytes
3 - 120 Gigabytes
4 - 160 Gigabytes
5 - 200 Gigabytes
6 - 240 Gigabytes
Contact Closure Module
Type
Channel 3-4 Modulator
1 - Alarm and contact closure in and out on DB-9
2 - Alarm and contact closure in and out on DB-9, plus
RJ-11 internal modem
0 - none
1 - present
Reserved
Conditional Access Type
800009-01 Rev. B 12 wegener.com
iPump6400 User’s Manual
Table 1: iPump6400 Options Key
Model Number
Position
J
Option Name
Line Cord
(power connector)
Designator Description
KK Other
1 - U.S.
2 - U.K.
3 - Europe
4 - Australia
00 - none
01 - Aux Audio
02 - KenCast FEC
03 - KenCast FEC plus Aux Audio
04 - OSD
05 - OSD plus Aux Audio
06 - OSD plus KenCast FEC
07 - OSD plus KenCast FEC plus Aux Audio wegener.com
13
iPump6400 User’s Manual
1.3 iPump6400 Specifications
Table 2: Technical Specifications
Characteristic Specification
RF
Input Frequency
Input FrequencyRange
Input Impedance
LNB Power
Tuning Resolution
Modulation
Transport Rate Range
VIDEO COMPRESSION
Video Data Rate
Compression Type
Horizontal Resolution
Vertical Resolution tuning via front panel control or COMPEL
950 to 2150 MHz
75 ohms
250 mA max, 22 kHz tone control vertical polarity: 12.4 to 14.0 VDC horizontal polarity: 17.0 to 19.0 VDC
1 kHz
QPSK
2.0 to 45 Msps up to 15 Mbps per service
MPEG 4:2:0 or 4:2:2
720, 704, 640, 544, 480, 352
480 lines @ 30 Hz (NTSC)
240 lines @ 30 Hz (NTSC)
576 lines @ 25 Hz (PAL)
288 lines @ 25 Hz (PAL)
VIDEO OUTPUT
Video Format
Output Level
Output Impedance
AUDIO COMPRESSION
Compression Type
Data Rate
Output Modes Supported
NTSC/PAL composite and SDI (with embedded audio)
1 Vpp ± 5%
75 ohms
MPEG Layer II
64 to 384 kbps
Mono, Dual Mono, Joint Stereo
800009-01 Rev. B 14 wegener.com
iPump6400 User’s Manual
Characteristic
AUDIO OUTPUT
Frequency Response
GENERAL
Power Supply
Table 2: Technical Specifications
Specification
20 Hz to 20 kHz
100 to 120 V or 200 to 240 V (auto switches)
60/50 Hz
5.0/2.5 A
Size weight height width
~20 pounds (9.1 kg)
3.5 inches (90 mm)
19 inches (483 mm)
[17 inches (432 mm) with mounting ears removed]
16"(406 mm) depth
ENVIROMENTAL
Use
Operating Temperature
Altitude
Humidity
Indoor only
+10° C to +40° C
Less than 2000 meters
Maximum relative humidity of 80% for temperatures up to 31° C decreasing linearly to 50% relative humidity at
40° C.
1.4 Safety Summary
The iPump6400 is designed for safe use with few special precautions required of the user. The following items are basic precautions to use when installing and working with your iPump6400:
Do not open the iPump6400's chassis cover.
wegener.com
15
iPump6400 User’s Manual
1.5 Glossary of Terms and Abbreviations
Table 3: Glossary of Terms
Term Definition
AC
Alarm
Alternating current
A condition or notification of a condition that prevents your iPump6400 from performing properly.
Assured File Delivery.
AFD
Authorized Describes an iPump6400 which has the ability through Compel Conditional Access to decrypt programs encrypted by the Compel software.
An RF signal containing coded audio, video, and/or other data.
Carrier
Compel
Wegener's network control software that may be used to manage a number of iPump6400s and other hardware.
Conditional access The means by which Compel controls which iPump6400s may decrypt specially encrypted audio, video, or data streams.
DVB
EIA
Ethernet
FTP
GB
Digital Video Broadcast
Electronic Industries Association
The widely-used LAN technology specified by IEEE standard 802.3
File transfer protocol
Gigabyte or 2
30
bytes
IEEE
LAN
LCD
LED
LNB
Institute of Electrical and Electronics Engineers
Local area network. Your iPump6400 may be connected to an Ethernet LAN.
Liquid crystal display. The front-panel text screen on your iPump6400 is a liquid crystal display.
Light-emitting diode. The front-panel indicator lights on your iPump6400 are LEDs
Mbps, kbps or
Msps
MPEG
Program
Program Number
RF
Low-noise block downconverter - equipment (generally at the antenna) that converts the incoming satellite signal to the appropriate frequency for reception by the iPump6400.
Units of data transport rate - Megabits per second (1 million bits per second), kilobits per second (1 thousand bits per second), or million symbols per second (1 million symbols per second)
Moving Picture Experts Group - refers to the method of video compression established by this group.
A single media stream (audio, video, data, etc.) tied to a common time base.
A numerical code representing a program.
Radio frequency
800009-01 Rev. B 16 wegener.com
SMB
Term
T
MRA
Warning iPump6400 User’s Manual
Table 3: Glossary of Terms
Definition
Server message block - a protocol for requesting services from and reading and writing to a file server.
Maximum Recommended Ambient Temperature, the highest operating temperature for which the unit is rated
A condition or notification of a condition that may compromise the proper performance of your iPump6400 wegener.com
17
iPump6400 User’s Manual
This page intentionally blank
800009-01 Rev. B 18 wegener.com
Chapter 2 Installation
This chapter provides instructions on unpacking, mounting, and connecting your iPump6400 as well as connector information including detailed pinouts.
2.1 Unpacking and Inspection
Carefully unpack the unit and its ac power cord and inspect for obvious signs of physical damage that might have occurred during shipment. Also locate the bag of accessories including 1/8-to-RCA and SVD-to-RCA adapters. Any damage claims must be reported to the carrier immediately. Be sure to check the package contents carefully for important documents and materials.
NOTE: Please save the packing materials and original shipping containers in case you must later return the unit for repair. Packing these units in other containers in such a way that they are damaged will void your warranty.
2.2 Location and Mounting
The iPump6400 should be mounted in a standard 19-inch equipment rack.
After mounting, maintain a clean, dry environment for the unit.
WARNING
This is a Class A product. In a domestic environment this product may cause radio interference for which the user may need to take mitigating action.
wegener.com
19 800009-01 Rev. B
iPump6400 User’s Manual
DANGER
To avoid damage to this and other equipment, or personal injury, the following items should be strictly observed.
Elevated Operating Ambient
When equipment is installed in a closed or multi-unit rack assembly, the operating ambient of the rack environment may be greater than the room ambient. Therefore, consideration should be given to the ambient air temperature within the rack, and not just inside the room, when deciding if the maximum recommended ambient operating temperature (T
MRA
) is being met.
Reduced Air Flow
Equipment should be installed such that airflow required for safe operation of the equipment is not compromised. The iPump6400 may be arranged in a rack without empty spaces between units if heat rise is prevented by ensuring its side vents remain unblocked with adequate clearance around the vent holes.
Mechanical Loading
Mounting of the equipment in a rack should be such that a hazardous condition is not produced by uneven loading. This unit is not very heavy, but total rack loading must be considered. Also, do not rest any unsupported equipment on your iPump6400.
Circuit Overloading
Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on overcurrent protection and supply wiring. Ensure that the total rack or breaker power consumption does not exceed the limits of the ac branch circuit.
Appropriate consideration of equipment ratings should be used when addressing this concern.
Reliable Earthing
Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (use of power strips, chassis ground lugs, etc.).
800009-01 Rev. B 20 wegener.com
iPump6400 User’s Manual
Your iPump6400 is sized at 2 RU and will fit an EIA-standard, 19-inch-wide
equipment rack (See “Size” on page 15.).
a) First, install angle brackets or cross-supports capable of supporting both the unit and its connecting cables. Screw or bolt the supports securely to the equipment rack.
b) Place the iPump6400 on its supports and use four anchor screws or bolts and nuts to secure the unit's front brackets to the rack.
WARNING
The front brackets must be secured to the rack. If front brackets are left unsecured, the unit may shift forward and fall from the rack during installation or operation. Failure to secure the front brackets may result in personal injury and/or damage to the equipment.
WARNING
Locate the iPump6400 and its cables to avoid impacts, spills, and pulling cables and to ensure sufficient air flow. Failure to locate the iPump6400 in a proper environment may result in damage to the equipment.
wegener.com
21
iPump6400 User’s Manual
2.3 iPump6400 Connections
Before applying power, make the following connections to your iPump6400
(refer to Table 4 on page 23 for connector details and to Figure 2.1
iPump6400 Rear-panel Connector Locations for placement):
a) Connect the L-band output from your antenna's LNB or from your multiswitch to the extender cable on your iPump6400's input RF port [a].
(A BNC connector is used here for iPump6400s with the ASI input option.) b) Connect a suitable audio monitor or monitors to the iPump6400's audio port(s) [b1] (on both decoders if your iPump6400 includes a second decoder). Also connect audio monitoring to the auxiliary audio port
[b2] if your iPump6400 includes that option (See Table 1: iPump6400
NOTE: See Optional Decoder with Digital Output on page 25 for an
illustration and audio/video connector details if your iPump6400 is equipped with an optional decoder with digital outputs.
c) Connect a suitable video monitor or monitors to the iPump6400's video port [c] (on both decoders if your iPump6400 includes a second
decoder). (See Table 1: iPump6400 Options Key on page 12).
d) Connect your LAN line to the iPump6400's Ethernet port [d]. (Refer to
Table 6: iPump6400 LAN Connector Pin Functions on page 24.)
Figure 2.1 iPump6400 Rear-panel Connector Locations
e) If desired, connect the Alarm port [e] to your equipment to provide contact closures and openings during alarms or on command from
Compel. (Refer to Table 5: iPump6400 Alarm Connector Pin
800009-01 Rev. B 22 wegener.com
iPump6400 User’s Manual f) Finally, connect the supplied ac power cord to the iPump6400's IEC receptacle [f] and to a 100-to-120 Vac or 200-to-240 Vac source.
NOTE: Do not connect devices to the mouse, keyboard and other connectors not described here. They are for factory use only.
Table 4: iPump6400 Connector Details
Designation
Connector
Type
Signal Description Additional Information
RF IN
ASI IN
AUDIO*
AUX AUDIO 1/8-inch stereo jack
VIDEO* Mini-DIN4 or
BNC
LAN female Type F female BNC
1/8-inch stereo jack female RJ-45
950 to 2150 MHz RF carrier from antenna LNB
ASI input signal
Audio output
Audio output
Video output
10/100baseT Ethernet
A extension cable is shipped already attached to the RF IN port to allow easier access for attaching your RF input.
Only on iPump6400s with the ASI input option.
A 1/8-to-RCA adapter is shipped with your iPump6400 (one for each active audio decoder).
Can be "slaved" to decoder 1 or decoder 2
A Mini-DIN4-to-RCA adapter is shipped with your iPump6400. Units equipped with the optional, professional 4:2:2 decoders will have a female BNC connector.
Autosensing; see pinout detail
CONTACT
CLOSURE/
ALARM male DB-9 Contact closure/opening in and out
See pinout detail in
Table 5: iPump6400 Alarm Connector Pin Functions
POWER Male IEC receptacle
100-to-120 Vac @60 Hz or
200-to-240 Vac @ 50 Hz
Autoswitching
* See connector details under
Optional Decoder with Digital Output
is equipped with a digital output decoder.
Alarm
Connector
Details
The DB-9 female alarm connector on the rear panel provides contact closures and openings during alarm conditions as well as a user relay available for control by Compel command (USER CC). Normal conditions represent the contact in normally functioning, powered operation. Other conditions or commands will reverse the status of the contact from its normal position.
wegener.com
23
iPump6400 User’s Manual
Pin functions of the DB-9 alarm connector are listed in Table 5 below.
Table 5: iPump6400 Alarm Connector Pin Functions
Pin Number
7
8
5
6
9
3
4
1
2
Function
Alarm common
Alarm Normally Open
Contact Closure Out Common
No Connection
Contact Closure Input
Alarm Normally Closed
No Connection
Contact Closure Out Normally Open
Ground
Ethernet/
LAN Port
Details
Pins 1 and 2 are normally open and are closed during an iPump6400 alarm.
Pins 1 and 6 are normally closed and are open during an iPump6400 alarm.
Pins 3 and 8 on the DB-9 are normally open and may be closed by command from Compel.
Pin 5 is the local, user input (0=trigger).
The iPump6400's 10/100baseT (autosensing) Ethernet port has the following pin functions:
Table 6: iPump6400 LAN Connector Pin Functions
Pin Number
7
8
5
6
3
4
1
2
Name
TX_D1+
TX_D1-
RX_D2+
Unused
Unused
RX_D2-
Unused
Unused
Description
Transmit Data+
Transmit Data-
Receive Data+
Receive Data-
800009-01 Rev. B 24 wegener.com
iPump6400 User’s Manual
Optional
Decoder with
Digital Output
Connector details are somewhat different for iPump6400s having the optional
Figure 2.2 Digital Output Decoder Connector Layout
Table 7: Digital Output Decoder Connectors
Ref Number
3
4
1
2
5
Connector Type
BNC
BNC
Mini-DIN4
1/8-inch Audio Jack
Tini Q-G Mini
Signal Description
Serial Digital Video Out
Composite Video Out
S-Video Out
Unbalanced Stereo Audio Out
Balanced Analog Audio and
AES/EBU Digital Audio Out wegener.com
25
iPump6400 User’s Manual
Pinout details for the balanced analog and AES/EBU digital audio connector
are shown in Figure 2.3 and Table 8 below.
Figure 2.3 Balanced Analog and AES/EBU Digital Audio Connector
Table 8: Balanced Analog and AES/EBU Digital Audio
Connector Pin Functions
Function Pin Number
3
4
1
2
5
6
Digital (AES3) +
Digital (AES3) -
Balanced Right -
Balanced Left -
Balanced Left +
Balanced Right +
800009-01 Rev. B 26 wegener.com
Multiswitch
Connection
Details
iPump6400 User’s Manual
When operating a multiswitch, use Table 9 to identify the line signals corre-
sponding to each iPump6400 RF port selection. On a typical multiswitch (as in
Figure 2.4 below), these ports will be in order from left to right as viewed
from the side holding the input connectors.
Table 9: RF Port Selection Signals
Port Number
3
4
1
2
Signal
13V with 22 kHz tone
18V with 22 kHz tone
13V without tone
18V without tone
Figure 2.4 Typical RF Multiswitch
wegener.com
27
iPump6400 User’s Manual
This page intentionally blank
800009-01 Rev. B 28 wegener.com
Chapter 3 Operation
3.1 Operation Overview
Most routine iPump6400 operations are performed over the Compel network or locally through the web-browser interface. However, front-panel control is
required to switch the unit’s software (see 3.7 Unit Software Switch) or to
change some key unit settings such as IP address, unit label, LNB LO value, and alarm/warning thresholds. It is important to remember that while most operations will be performed remotely, the iPump6400 does not prioritize incoming commands based on which interface is used. The iPump6400 treats commands from the front panel with importance equal to commands from both the Compel network and the browser interface. Commands are prioritized based only on the order in which they are received. The first command received is the first one performed. (Of course, when local control is disabled by command from Compel, no local control is possible until re-enabled by
Compel.)
In addition to introducing and describing the front-panel and web browser interfaces, this chapter provides details on startup/shutdown of your iPump6400, making initial unit settings for basic operation, and performing tasks over the web browser interface. The chapter is organized into the following sections:
•3.2 Front-panel Controls and Indicators,
•3.3 Startup/Shutdown Procedures,
•3.6 iPump6400 Operations by Function, and
NOTE: When operated as part of a Compel Network, your iPump6400 may at times become unavailable for local control or may perform functions not commanded locally. For example, the Compel network operator may command remote iPump6400s to disable local control during a particular broadcast or program schedule. Also, if set up to expect Compel commands, your iPump6400 may begin searching RF channels for a Compel signal if that signal is temporarily lost.
wegener.com
29 800009-01 Rev. B
iPump6400 User’s Manual
3.2 Front-panel Controls and Indicators
There are three major parts of your iPump6400's front-panel controls and indicators: the liquid-crystal display (LCD), the six push buttons, and the eight
LED indicators.
Liquidcrystal
Display(LCD)
Figure 3.1 iPump6400 Front Panel
The iPump6400's LCD indicates unit status and prompts for and reflects user input. Here, you will see your iPump6400's unit label and serial number displayed on the top line following startup. The home screen also alternately displays the input signal’s frequency, data rate, and FEC ratio in the lower left corner and continuously displays the current signal-to-noise ratio in the lower right. Using the adjacent push buttons (described in the next paragraph), you can navigate the iPump6400's various screens and edit input fields.
Push buttons
These six push buttons are your means of commanding the iPump6400 from the front panel. The four arrow buttons allow navigation through the menu screens and parameter selection and editing in user-input screens. The ENTER button serves to select menu options (downward navigation), to open userinput fields, or to commit user input to the iPump6400. Also press ENTER to quickly start the unit after a normal shutdown. The Escape (ESC) button allows exit from user-input fields without saving the entry or selection. ESC also provides upward navigation through the menu structure to the home screen.
800009-01 Rev. B
Figure 3.2 Push buttons
30 wegener.com
LED
Indicators
iPump6400 User’s Manual
These eight light-emitting diodes (LEDs) provide status information about
your iPump6400 and its processes. Table 10 on page 31 provides the meaning
of the color and state of each LED.
Figure 3.3 LED Indicators
Table 10: LED Indicator Descriptions
Indicator Label Color and State
CARRIER
GREEN constant Receiver is tracking carrier.
Meaning
GREEN slow blink Receiver is not tracking carrier.
RECORD
GREEN constant
LAN
Off
DOWNLOAD
GREEN constant
Off
GREEN constant iPump6400 is recording a program.
iPump6400 is not recording.
iPump6400 is downloading a file via Compel.
iPump6400 is not downloading.
Light network activity over the iPump6400’s LAN interface
GREEN slow blink Heavy network activity over the iPump6400’s LAN interface
COMPEL
Off
GREEN constant
GREEN fast blink
GREEN slow blink
Off iPump6400 observed no packet transfers on the LAN interface during the last 20 seconds.
iPump6400 has received a COMPEL command within the last two minutes.
iPump6400 has been addressed by COMPEL within the last five seconds.
iPump6400 is in tracking mode, COMPEL is required, but no COM-
PEL command has been received within the last two minutes.
COMPEL is not required and not received within the last two minutes; or, iPump6400 is not in tracking mode.
wegener.com
31
iPump6400 User’s Manual
Table 10: LED Indicator Descriptions
Indicator Label Color and State
AUTH
Meaning
GREEN constant Current transport stream is protected by conditional access (CA) and iPump6400 is authorized and descrambling.
GREEN slow blink Current transport stream is protected by conditional access (CA) but iPump6400 is unauthorized.
Off Tracked channel is not scrambled.
WARNING*
AMBER constant
Off
One or more warning conditions exist. Read warning information from front-panel LCD.
No warning conditions exist.
ALARM*
RED constant One or more alarm conditions exist. Read alarm message from LCD.
Off No alarm condition exists.
* Only one alarm or warning condition is displayed at a time on the LCD in place of the normal home screen information. When multiple alarm or warning conditions exist, those conditions are displayed in the order of importance. The most critical condition is displayed first. Further alarms or warnings will be shown after the more critical item(s) is cleared.
800009-01 Rev. B 32 wegener.com
iPump6400 User’s Manual
3.3 Startup/Shutdown Procedures
The first time you start the iPump6400, the boot-up process and some initial setup may require a few minutes to complete. (See Initial Unit Settings.) After the initial startup, and if a normal shutdown was performed, the iPump6400 may be started again simply by pressing the ENTER button on the unit’s front panel.
Initial startup
a) For initial startup, set the power switch to the On position ( I ) and press and hold the ENTER button for two seconds. The iPump6400 will power up and begin the boot process. Usually within three minutes, the unit will complete its initialization (all outputs are muted during this time).
Normal
Startup
b) The eight, front-panel LEDs flash on and off together once and then three more times in succession. The LCD shows the current firmware version and the message, "Booting, please wait. . . .". The expanding and contracting ellipsis shows that the iPump6400 is booting the software.
(Note that the version number shown is that of the front-panel firmware only and does not indicate the current version of the application software.) c) During bootup, a quick check of the file system is made to detect and fix any corrupted files. The message "Auto Maintenance . . ." indicates that this check is in process. The duration of the file system check depends on the extent of any needed repairs to the file system and the size of the affected files. When no problems are detected, the "Auto Maintenance" message will only briefly flash on the LCD. If the file system is corrupt beyond repair, the message, "Filesystem is corrupt . . ." will appear.
Otherwise, the auto maintenance process is continuing normally and you should wait for it to complete.
d) Following a normal check of the file system, the message, "Continuing to boot . . ." is displayed. At completion of bootup, the LEDs will light
individually as appropriate to show unit and signal status (see Table 10:
LED Indicator Descriptions on page 31). The display then becomes
"live" and will typically indicate a loss-of-carrier alarm condition if the unit’s RF configuration has not been completed. This is normal and simply means that the RF settings must be adjusted. After the RF setup has been completed, subsequent startups will finish by displaying the home screen
(showing the unit's serial number, E b
/N
0
, and alternately displaying FEC ratio, signal frequency, and data transport rate). This indicates that your iPump6400 is functioning normally and is ready for use.
Following initial startup and after a normal shutdown has been performed, the iPump6400’s normal startup may be performed quickly by simply pressing the
ENTER button on the front panel. If the receiver is tracking a carrier signal, the green CARRIER LED will light. If the RF set up has not been performed or the receiver cannot track the carrier, the red Alarm LED will light.
wegener.com
33
iPump6400 User’s Manual
Web Browser
Operations
Startup
For HTML control and status checking from a web browser, first navigate from the home screen to the IP Setup screen. (iPump6400 operations per-
formed via a web browser are described under 3.6 iPump6400 Operations by
Step a) b) c) d) e)
Press
ENTER
Displayed
UNIT SETUP
RECORD AND PLAY
DECODER SETUP
AUDIO SETUP
IP SETUP
Screen Type
Menu
Menu
Menu
Menu
Menu
Press ENTER and take note of the iPump6400's IP address displayed on the screen. Then use the following steps to gain control from your web browser:
NOTE: It may be necessary to set the IP address, subnet mask, and gateway to specific values - consult your local network administrator. Include leading zeros in addresses entered from the iPump6400 front panel, but not when entering them from the browser interface.
a) Open a current-version internet browser from a computer on the LAN attached to your iPump6400.
b) In the browser's address field, enter the IP address noted from the IP
Address screen and the Status tab of the iPump6400 web interface will appear.
800009-01 Rev. B 34 wegener.com
iPump6400 User’s Manual
Normal
Shutdown
wegener.com
Figure 3.4 iPump6400 Web Interface (Status Tab)
NOTE: For IP addresses which include subfields with leading zeros, you
must omit those zeros when entering the address in your browser. For example, IP address 128.092.050.004 (as entered from the iPump6400 front panel) must be entered as 128.92.50.4 in the web browser.
Removing power to shut down your iPump6400 will not harm the unit, but is not recommended and will lengthen the time required for the next startup. Normal startup can only be performed following a normal shutdown. To shut down your iPump6400: a) Return to the iPump6400 home screen (press ESC repeatedly until model and unit number or an alarm or warning message is displayed) b) Press the right-arrow button four times to reach the Unit Shutdown screen.
c) Press the ENTER button to select Unit Shutdown and when prompted, press the ENTER button again to confirm.
In less than 30 seconds, the iPump6400 will power down and the LCD and
LEDs will go out. Your iPump6400 is now ready for normal startup by pressing the ENTER button.
35
iPump6400 User’s Manual
3.4 Front-panel Operation
Operate the iPump6400 from the front panel using the push buttons and LCD.
Menu screens on the LCD direct you to screens that control various operating parameters or display information about the iPump6400. Menu titles represent either a category of control (such as Unit Setup, Record and Play, and RF
Setup) or the name or category of parameters or information to be displayed
(such as RF Status, Active Recordings, or Navigation Help).
LCD Menu
Navigation
Refer to Figure 3.5 which illustrates the complete LCD menu structure. Informa-
tion and user-input screens beneath these menus are described later. Press the right and left arrow buttons to move between menu screens on the same level
(represented in the illustration by arrows connecting the left and right sides of the boxes). When you reach the last menu of a particular level, pressing the right arrow button again will move you back to the first menu of that level. Press the
ENTER button to move down to the next level of the menu structure (represented in the illustration by arrows connecting the top and bottom sides of boxes) or to view the information and user-input screens within a particular category. Press the ESC button to move up a level or to the first menu of the current level. Pressing the
ESC button repeatedly will always return you to the Home Screen.
800009-01 Rev. B
Figure 3.5 LCD Menu Structure
36 wegener.com
Editable
Fields
iPump6400 User’s Manual
User input screens below the menus shown here allow control of such items as
Program Number to Record, File to Record to, Decoder Number to Play File to, and others. There are two types of user-input screens - those with an editable field and those with a selectable field.
User-input screens with editable fields accept data entry by the user. Shown here is an example of a user-input screen with an editable field.
Figure 3.6 Editable Field
To make changes to the data in the field: a) Press ENTER to open the field. The first character location of the field is highlighted.
b) Press the up or down arrow buttons to increment that digit or letter until the desired value is displayed. Press the right arrow button to move to the next digit or location in the field and change it the same way.
Continue until all digits or letters are displayed correctly.
c) Press the ENTER button to save your changes. Pressing ESC before pressing ENTER will cancel any changes.
Another type of editable field appears when filenames must be entered. These fields have the following appearance: wegener.com
Figure 3.7 Filename Field
a) Press ENTER to begin spelling the filename. The letter A in the character list is highlighted.
b) Press the arrow buttons to move through the character list until the first character of the filename is highlighted. (Additional characters including numerals, decimal, space, and hyphen appear on the LCD as you move downward through the available characters list.)
37
iPump6400 User’s Manual
Selectable
Fields
c) Press ENTER to confirm the first character. The first character is displayed at the bottom left of the LCD.
d) Select additional characters as in steps b) and c) until the entire filename is displayed completely at the bottom left of the LCD.
e) When the entire filename is shown, press ESC to stop editing. When prompted, "Done?", press ENTER if the filename is correct or ESC to continue editing your entry.
Other user-input screens allow choosing from a list of options. Here is an example of a user-input screen with a selectable field.
Figure 3.8 Selectable Field
When you reach the screen, the current selection is displayed. To change your selection: a) Press ENTER to open the field. The current selection is highlighted.
b) Press the up or down arrow buttons to view available options one at a time.
c) When the desired option is shown, press the ENTER button to save that selection. Pressing ESC before pressing ENTER will cancel any change.
NOTE: Front-panel control is limited by a four-minute timeout period. After four minutes without input from the front-panel push buttons, the iPump6400
LCD will automatically return to the home screen and any unsaved changes will be lost.
800009-01 Rev. B 38 wegener.com
iPump6400 User’s Manual
3.5 Initial Unit Setup
Some of the iPump6400’s settings are preconfigured or should be configured during the iPump6400's initial setup and are not likely to require adjustment on a regular basis. RF current channel, LNB type, LNB DC power, date and time, and unit label settings should be made at this time.
Initial RF setup
A few of the RF settings are preconfigured and should only be changed if advised by your satellite operator. These include the LNB LO value, SNR
Alarm Threshold, and SNR Margin Warning settings. The table below lists these settings as they are configured on your iPump6400 when it is delivered from the factory.
Table 11: iPump6400 Preconfigured RF Settings
Parameter
LNB LO Value
Preset Value
10750 MHz
(appropriate for Ku-band reception -
5150 MHz would be an appropriate setting for
C-band operation)
SNR Alarm Threshold
(signal-to-noise ratios below this value will result in an alarm condition)
SNR Margin Warning
(warning condition triggered when signal-tonoise ratio is within 3.0 dB of the SNR Alarm
Threshold - under 8.0 dB as preset)
5.0 dB
3.0 dB
Current
Channel
Setup
Navigate to the RF Setup screen.
wegener.com
Step a) b)
Press Displayed
UNIT SETUP
ENTER
RECORD AND PLAY
39
Screen Type
Menu
Menu
iPump6400 User’s Manual
Step c) d) e) f)
Press Displayed
DECODER SETUP
AUDIO SETUP
IP SETUP
RF SETUP
From RF Setup, adjust the Current Channel settings.
Screen Type
Menu
Menu
Menu
Menu
Step a) b) c) d)
Press
ENTER
ENTER
Displayed/Field Details Screen Type
RF STATUS:
TRACKING: Eb/No = XX.X
Data Display
RF status is shown. If tracking, then Eb/N0 is also displayed.
CURRENT CHANNEL
Menu
RF-INPUT PORT:
1
This screen only appears when LNB type is set to Multiswitch. If shown, select port 1, 2, 3, or 4.
DOWNLINK FREQUENCY:
XXXXX.XX MHz
Enter downlink frequency from the LNB local oscillator in megahertz.
User Input -
Selectable
User Input -
Editable
800009-01 Rev. B 40 wegener.com
iPump6400 User’s Manual
Step e) f) g) h) i)
LNB Type
Selection
Press Displayed/Field Details
TRANSP. DATA RATE:
XXX.XX Mbps
Enter transport stream data rate in megabits per second.
RF-MOD/FEC RATIO:
QPSK 3/4
RF modulation is QPSK. Available forward error correction ratios are 1/2, 2/3, 3/4, 5/6, and 7/8.
PROGRAM NUMBER:
00001
Enter the number or code of program to select from stream.
TAG SITE:
Screen Type
User Input -
Editable
User Input -
Selectable
User Input -
Editable
<Unused>
Values entered in this field will not affect iPump6400 operation.
SAVE ALL CHANGES?
YES<ENT> NO<ESC>
Press ENTER to save or ESC to cancel all RF Setup changes and return to the Current Channel screen.
Navigate to the RF Setup screen.
User Input -
Selectable
Step a) b) c) d)
Press Displayed
UNIT SETUP
ENTER
RECORD AND PLAY
DECODER SETUP
AUDIO SETUP
Screen Type
Menu
Menu
Menu
Menu wegener.com
41
iPump6400 User’s Manual
Step e) f)
Press Displayed
IP SETUP
RF SETUP
From RF Setup, select the LNB type.
Screen Type
Menu
Menu
Step a)
Press
ENTER
Displayed/Field Details
RF STATUS:
TRACKING: Eb/No = XX.X
RF status is shown. If tracking, then Eb/N0 is also displayed.
CURRENT CHANNEL
Screen Type
Data Display b) Menu c)
LNB TYPE
User Input -
Selectable
Available LNB types are Multiswitch, Universal./Astra, and Local Oscillator. Note that for proper multiswitch operation, LNB DC Power must be set to ON.
LNB DC
Power Setting
LNB DC Power must be set ON for proper multiswitch operation. First, navigate to the RF Setup screen.
800009-01 Rev. B
Step a) b) c)
Press Displayed
UNIT SETUP
ENTER
RECORD AND PLAY
DECODER SETUP
42
Screen Type
Menu
Menu
Menu wegener.com
Step d) e) f)
Press Displayed
AUDIO SETUP
IP SETUP
RF SETUP
From RF Setup, set the LNB DC Power.
iPump6400 User’s Manual
Screen Type
Menu
Menu
Menu b) c) d)
Step a)
Press
ENTER
Displayed/Field Details
RF STATUS:
TRACKING: Eb/No = XX.X
RF status is shown. If tracking, then Eb/N0 is also displayed.
CURRENT CHANNEL
LNB TYPE
Select ON or OFF.
LNB DC POWER
Screen Type
Data Display
Menu
User Input -
Selectable
User Input -
Selectable
Date/Time
Setup
NOTE: When operating under the Compel network, date and time settings are overwritten by Compel. Time zone and Daylight Savings Time settings, however, remain under local control and should be set by the user.
Set up the date and time for your iPump6400 during the initial setup. First navigate to the Date/Time Setup screen. (Date/Time setup may also be performed from the browser interface under the SETUP tab.) wegener.com
43
iPump6400 User’s Manual
From Date/Time Setup, adjust the current date, time, offset from GMT, and daylight saving time settings as follows:
800009-01 Rev. B
Step Press Displayed/Field Details
Screen
Type a)
ENTER
b) c) d)
CURRENT DATE
YYYY/MM/DD
Enter current date in year/month/day format.
CURRENT TIME
HH:MM:SS
Enter current time in hours:minutes:seconds format.
User Input
- Editable
User Input
- Editable
OFFSET FROM GMT
GMT -5 (EST/EDT)
Select the appropriate offset from Greenwich
Mean Time (GMT). Offset selections range from GMT -12 to GMT +11. (Eastern U.S. is at
GMT -5; West Coast U.S. is at GMT -8.)
DAYLIGHT SAVING TIME
OBSERVED? YES
Select Yes if daylight saving time is observed in your area or No if it is not.
User Input
-Selectable
User Input
-Selectable
44 wegener.com
Unit Label
Setup
iPump6400 User’s Manual
Set the unit label (or name of your iPump6400) during the initial setup. First navigate to the Set Unit Label screen.
wegener.com
From Set Unit Label, enter a name for your iPump6400 as follows:
Step Press Displayed/Field Details
Screen
Type a) b)
ENTER
ESC
U. LABEL ABCDEFGHI
JKLMNOPQR
Press
ENTER
to begin spelling the unit label.
Press the arrow buttons to select the first character. (Additional characters including numerals, decimal, space, and hyphen appear as you move downward through the available characters.)
Press
ENTER
to confirm the first character.
Select additional characters in the same fashion until the unit label is displayed completely at the bottom left of the LCD.
Done? [Yes] [No-Esc}
__________
User
Input -
Selectable
Press
ENTER
to confirm the unit label or
ESC
to return to the U. Label screen.
User
Input -
Editable
45
iPump6400 User’s Manual
3.6 iPump6400 Operations by Function
Most iPump6400 functions can be performed locally from either the front panel or from a web browser attached to the iPump6400 via Ethernet. However, web browser operation is described in this section because after initial configuration, that is the method by which most local operations will be performed. Operations are listed and described by function.
Monitor iPump6400
Status
Monitor iPump6400 status as follows: a) Enter the iPump6400's IP address in the address bar of your web browser.
b) The iPump6400 Status tab is automatically displayed.
The unit’s serial number, current software version, and model number are shown. Receiver mode, signal-to-noise ratio, decoder states and settings, packet counts, and record activities are also displayed and refreshed every few seconds.
800009-01 Rev. B 46 wegener.com
iPump6400 User’s Manual
Live Program
Play
When set up for live program play, the iPump6400 decodes an incoming
MPEG stream from the received DVB satellite signal and decrypts and decodes the audio and/or video from the selected program to the connected audio and video monitors. Two live programs from the same DVB carrier may be played simultaneously if your iPump6400 has the optional second decoder.
a) To set up for live program play, first ensure the appropriate RF input and audio and/or video output connections have been made.
b) Next, ensure that the proper RF settings have been selected. Check that downlink frequency, transport data rate, FEC ratio, and program number are properly selected before playing a live program.
NOTE: The LNB LO frequency may only be set from the front panel. In typical operation, changes to this setting are not usually necessary after initial unit setup.
c) From your web browser, click the Setup tab to display the various iPump6400 settings. (The Aux Audio settings only appear for units equipped with the Aux Audio option.) wegener.com
47
iPump6400 User’s Manual d) Next, click the Edit button under Satellite Receive Settings to change that group’s parameters.
e) After changing the fields as needed, click the Activate button to save your changes. Any changes will take effect immediately.
f) If you do not wish to make or save any changes, click the Cancel button and any changes will be discarded.
g) Next, click the Edit button under Settings for Decoder #1 (or #2 if available and desired).
800009-01 Rev. B h) Choose a specific DVB program, an IP multicast program, Follow
Tune, or Off from the Setting pull-down menu. The Follow Tune setting causes the decoder to play whatever DVB program is selected under Satellite Receive Settings. Audio and video mute options, plus
UDP port and multicast address if multicast is chosen, may also be selected from this screen. If you don't wish to keep your changes, click the Cancel button. Otherwise, click the Activate button to make your changes immediately effective and begin playing the selected program.
48 wegener.com
wegener.com
iPump6400 User’s Manual
NOTE: The setting at initial startup is Follow Tune. To stop live program playing, select Off under Decoder Settings.
i) Next (if the Aux Audio option is enabled), click the Edit button under
Settings for Aux Audio to change that group’s parameters and provide an extra audio-only service through the auxiliary audio port.
j) Choose a specific DVB program, an IP multicast program, Follow
Tune, Follow Decoder 1 (or 2), or Off from the Setting pull-down menu. The Follow Tune setting causes the decoder to play the audio from whatever DVB program is selected under Satellite Receive
Settings. For IP multicast programs, also set the UDP port and multicast address. The first audio content detected in that stream is used.
When Aux Audio is set to Follow Decoder 1 (or 2), it uses the same program to which the followed decoder is set and a language descriptor
(from the Language setting) is used to find a matching audio stream within that program. The Language may be the same as, or different from, the primary audio output of the followed decoder. If First Available is chosen as the Language setting when Aux Audio is set to Follow
Decoder, the next unused available audio is played. Consider the example of a program that contains a first audio ‘ENG’ and a secondary audio
‘FRE’ and the followed decoder’s language descriptor is set to ‘ENG’. If the Aux Audio is set to ‘ENG’, then both will produce the audio tagged as
‘ENG’. Likewise, if the followed decoder is set to First Available and the
Aux Audio is set to ‘ENG’ they will both produce ‘ENG’. However, if the followed decoder is producing ‘ENG’ and the Aux Audio is set to
First Available, the Aux Audio will produce ‘FRE’ because ‘ENG’ is already being produced by an audio port for the followed decoder.
If Aux Audio is set to Follow Decoder 1 (or 2) and a normal file play action takes place on the followed decoder, then the Aux Audio port will be silent for the duration of the file play. However, if the file was recorded using the All Audio option, then during playback to an A/V decoder, any audio within the file with a matching language descriptor will be sent to the Aux Audio port during file playback.
NOTE: A file may only be played back through the Aux Audio port if Aux
Audio is not set to Follow Decoder 1 or 2. The single audio stream in the file is extracted and played (regardless of the Aux Audio Language setting), and the associated video is discarded.
Also choose the desired mute option (Muted or Unmuted) for Audio
Left and Audio Right. If you don't wish to keep your changes, click the
Cancel button. Otherwise, click the Activate button to make your changes immediately effective and begin playing the selected program.
49
iPump6400 User’s Manual
Record
Program to
File
The iPump6400 can record incoming programs to stored files for later playback. Up to three separate programs may be recorded at one time.
NOTE: Record and Play settings are volatile through power cycles. Except for the Loop Forever playlist setting, these settings will be lost when the iPump6400 is rebooted. If Loop Forever is selected, then the playlist chosen to loop forever will begin playing when the iPump6400 returns to service after a reboot.
a) To set up the iPump6400 for program recording, first ensure the appropriate RF input settings have been selected.
b) Click the Rec/Play tab from your web browser interface.
c) Under Record, in the Filename: box, enter a name for the file you wish to record. File names are limited to 16 characters. Upper and lower case letters, numerals, decimals and spaces are allowed, but leading or following spaces will be truncated (the file name may not begin or end with a space or spaces).
NOTE: Users should avoid accidentally overwriting an existing file. The iPump6400 front panel will display a warning message before the Record function overwrites an existing file with the same name but will not prevent overwriting.
800009-01 Rev. B 50 wegener.com
Play
Recorded
Program File
iPump6400 User’s Manual d) Next enter a time in the Length of Recording boxes. Enter the duration of time to record in hours, minutes, seconds (HH:MM:SS), and tenths of a second. Enter a duration slightly longer than the expected program length to ensure that you record the entire program.
To record for an indefinite period, enter zero time. The iPump6400 will continue to record until commanded to stop or until available disk space is consumed.
NOTE: If the storage capacity is filled over 99% during recording, the iPump6400 begins deleting existing files in chronological order beginning with the oldest file. The current recording will not be interrupted unless all deletable files have been deleted and remaining storage capacity remains under
1%.
e) If the program is classical MPEG, click the appropriate radio button to select a Single Audio program or All Audio and choose a program from the dropdown list.
f) Otherwise, if the program is MPEG within IP, click the IP Program radio button and enter the IP multicast address and port number corresponding to the desired stream.
g) Click the Record button to begin recording the selected program.
NOTE: To stop recording before the end of the entered length of recording, click the "Stop" hyperlink for the appropriate file on the Record/Play chart.
Use the following steps to play a recorded or previously downloaded program file: a) Click the Rec/Play tab from your web browser interface.
b) Select a file or playlist to play by clicking its name under the File
Playback list. The name of the current directory is shown just above the list of files. When displayed, you may double click
[-Previous
Directory-]
to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets
(such as
[directoryname]
) to move down to that directory level.
c) If selecting a playlist, you may also click one of the three radio buttons to either Loop on Last (repeating the last program until stopped by the user), Loop Forever (repeating the entire sequence until stopped by user), or Loop N Times (repeating the entire sequence N times).
NOTE: The Rec/Play tab initially displays the contents of the
/recorded
directory, but the user may also record to or play from files in other directories.
wegener.com
51
iPump6400 User’s Manual
File
Management
d) Click the Play to Decoder 1 or Play to Decoder 2 button to immediately begin playing the program or playlist through the desired decoder. (Play to Decoder 2 will only appear for dual-decoder iPump6400s.) The Record/Play chart on the left will display the name and time remaining of the selected program or playlist. e) To stop playing a program or playlist before it has played completely, click the "Stop" hyperlink under the Record/Play chart.
View, delete, and rename files using the following procedure: a) Click the Files tab from your web browser interface.
800009-01 Rev. B b) Select a file by clicking on its filename under the File Manager list (file size in bytes is shown adjacent to each filename). The name of the current directory is shown just above the list of files. When displayed, you may double click
[-Previous Directory-]
to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets (such as
[directoryname]
) to move down to that directory level.
c) To view a file, click the View File button or double-click the filename to open/play the file on your screen. The file will be opened by the application indicated by the extension on the filename (Windows Media
Player for MPG files, Microsoft Word for DOC files, for example).
d) To delete the selected file, simply click the Delete File button.
52 wegener.com
File
Streaming and Routing
iPump6400 User’s Manual e) To rename the file, first type the new name in the Rename To: box.
As with recording new files, file names are limited to 16 characters.
Upper and lower case letters, numerals, decimals and spaces are allowed, but leading or following spaces will be truncated (the file name may not begin or end with a space or spaces). After completing the filename, press the Rename To: button to rename the file.
For multicast streaming of stored files, do the following: a) First, click the Streams tab on the web browser interface.
wegener.com
b) If streaming from an existing file, select a file from the Streaming
Files list. The name of the current directory is shown just above the list of files. When displayed, you may double click
[-Previous
Directory-]
to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets
(such as
[directoryname]
) to move down to that directory level.
NOTE: A file streamed to a destination already receiving a live stream will supersede the live stream until the file stream has stopped. The live stream, in progress, will then continue.
53
iPump6400 User’s Manual
Scheduled
Operation
c) If streaming live from a "classical" DVB program, select the program to stream from the Program/Language pull-down list under
Stream Live Program.
d) Click inside the Multicast Destination: box and type the appropriate
IP address. Also enter the UDP Port number in the UDP Port: box.
e) When the address information and selected file or stream information are correct, click the Start File Stream: or Start Live Stream: button respectively to begin streaming.
f) Stop file streaming by highlighting the desired stream from the
Stream Status list and clicking the Stop button.
From the web browser interface, you can view schedules of record and play operations set up by the Compel network for the iPump6400 by clicking the
Schedule tab.
If needed, you can click the Disable button to temporarily suspend scheduled operations. Click Enable to return to scheduled operations. The iPump6400 will resume performing operations according to the scheduled times. Operations scheduled for times during which the unit is "disabled" will not be performed.
800009-01 Rev. B 54 wegener.com
Playlist
Management
iPump6400 User’s Manual
With iPump6400 playlists, you can set up and play a stored sequence of programs without interruption. (Playlists are stored in nonvolatile memory such that they remain available after unit reboots.) Create or edit playlists from the web interface using the following procedure: a) Click the Playlist tab from your web browser interface b) To create a new playlist, first click the Create Playlist button.
wegener.com
55
iPump6400 User’s Manual c) A playlist number will appear. If desired, type a name in the Playlist
Name box and click the Rename button. This name (rather than the number) will appear in the list of existing playlists.
d) Next select the programs to include in the playlist. Programs may be selected one at a time (click the filename of the desired program) from the Directories box and added to the Spots in Playlist by clicking the left-arrow button. Double click directory names (displayed in red text) to browse other directories. Multiple files may be highlighted at one time by using control-click to select individual files and shift-click to select multiple adjacent files. Again, clicking the left-arrow button adds all highlighted programs to the playlist.
NOTE: When a playlist is chosen for file playback, programs will be played in the order that they appear in the playlist.
e) To edit an existing playlist, first select it from the Edit Existing
Playlist dropdown.
f) Files are removed from the playlist by highlighting using the same click, control-click, and shift-click methods followed by clicking the
Remove From List button. All spots may be removed from the playlist by clicking the Clear List button.
g) Add files to the list in the same manner as when creating a new playlist.
If desired, a program may be inserted in the middle of a list. Do this by first highlighting a spot in the playlist before which the new program should appear. Then add the new program as before. The added file will be inserted before the highlighted playlist spot.
NOTE: RANDOM and SEQUENTIAL are default "files" which may be added to any playlist. When RANDOM is selected, the iPump6400 randomly selects a file to play from the selected directory. When SEQUENTIAL is selected, the iPump6400 plays the first file in the selected directory that has not already been played as SEQUENTIAL. Or, if all files in the selected directory have been played as SEQUENTIAL, then SEQUENTIAL will again play the first file. For example, if the selected directory contains the files ’A’, ’B’, ’C’, and ’D’ (in that order), then the first time SEQUENTIAL appears in the playlist, file ’A’ will be played. The second, third, and fourth times
SEQUENTIAL appears in the playlist, the files ’B’, ’C’, and ’D’ will be played respectively. If SEQUENTIAL appears in the playlist a fifth time, then file ’A’ will be played again and so forth. The file played by the SEQUENTIAL entry is dependent only on the order of files played as SEQUENTIAL and is not affected by any other previous playlist entries.
800009-01 Rev. B 56 wegener.com
iPump6400
Help
iPump6400 User’s Manual
NOTE: To provide a course of action for the iPump6400 in case of a "loss of service" (RF signal drops below a minimum threshold or the feed is lost entirely), a playlist named LOS may be created. The iPump6400 will begin playing this playlist immediately when a "loss of service" condition arises.
When the signal is regained, the iPump6400 will return to the live feed it was originally playing.
Access help in the form of an online manual and a list of questions and answers by clicking the HELP tab from your web browser.
wegener.com
57
iPump6400 User’s Manual
3.7 Unit Software Switch
The Unit Software Switch function is only available from the iPump6400 front panel. Use the following procedure to switch between versions of application software loaded on your iPump6400:
From the iPump6400 front panel, navigate to the Unit Software Switch to B-
Up screen.
From the Unit Software Switch screen, switch software as follows:
Step Press Displayed/Field Details a)
ENTER
SW FROM V230 TO
V340
The available software version switch is displayed. Press ESC if you do not wish to make the switch shown. Press ENTER to begin booting the alternate application software version.
b)
ENTER
V340 Booting, please wait . . . . .
The expanding and contracting ellipsis (line of periods) indicates that the alternate software is booting.
Screen
Type
Menu
Status
Display
800009-01 Rev. B 58 wegener.com
Chapter 4 Maintenance and Troubleshooting
4.1 Maintenance
Maintenance of the iPump6400 is limited to keeping the chassis clean and ensuring that cables remain firmly connected. Occasionally wipe the exterior with a soft, damp cloth to remove any accumulated dust and dirt and check that cables are securely attached.
The iPump6400 incorporates security labels over some of the screws. There are no user-serviceable components within the iPump6400. Tampering with the security labels or opening the unit will void your warranty. If you have any questions, contact Wegener’s Customer Service Department at the address or numbers listed under Customer Service.
4.2 Troubleshooting
This section is not intended as an exhaustive list of all possible situations.
Please contact us (see Chapter 5, Customer Service), with any problems you cannot resolve independently.
No functions at all
If you are experiencing any difficulties, first check the LCD and LED indicators on the iPump6400 to determine if any warnings or alarms are active. See
Table 12: LED Indicator Descriptions on page 60 for descriptions of LED
states.
If the unit is not functioning at all and neither the LCD nor any LEDs are lit, there may be a loss of ac power. Do the following:
a) Check that the power switch is set to the On position. See Figure 2.1 on page 22.
b) Check that ac power cord is firmly connected at both ends.
c) Check that your ac power source is supplying ac power.
d) Press the ENTER button on the front panel.
wegener.com
59 800009-01 Rev. B
iPump6400 User’s Manual
No output
Trouble using browser interface
LED
Indicators
If the unit is receiving power and there are no alarm or warning conditions indicated by the front panel, but there is still no output, check your monitoring equipment for proper function. Also check to determine if the program or file is "blank".
If the iPump6400 appears to be functioning normally with no alarm or warning conditions, but you cannot use the web browser interface, first check that you
are using the correct IP address. (See “Web Browser Operations Startup” on page 34.)
If the address is correct, but the interface still does not function, check your computer’s IP settings and consult your network administrator for additional help.
NOTE: Only one alarm or warning condition is displayed at a time on the
LCD. When multiple alarm or warning conditions exist, those conditions are displayed in the order of importance. The most critical condition is displayed first. Further alarms or warnings will be shown after the more critical item(s) is cleared.
Table 12: LED Indicator Descriptions
Indicator Label Color and State
CARRIER
GREEN constant Receiver is tracking carrier.
Meaning
GREEN slow blink Receiver is not tracking carrier.
RECORD
GREEN constant
LAN
Off
DOWNLOAD
GREEN constant
Off
GREEN constant iPump6400 is recording a program.
iPump6400 is not recording.
iPump6400 is downloading a file via Compel.
iPump6400 is not downloading.
Light network activity over the iPump6400’s LAN interface
GREEN slow blink Heavy network activity over the iPump6400’s LAN interface
Off iPump6400 observed no packet transfers on the LAN interface during the last 20 seconds.
800009-01 Rev. B 60 wegener.com
iPump6400 User’s Manual
Indicator Label Color and State
COMPEL
AUTH
Meaning
GREEN constant
GREEN fast blink
GREEN slow blink iPump6400 has received a COMPEL command within the last two minutes.
iPump6400 has been addressed by COMPEL within the last five seconds.
iPump6400 is in tracking mode, COMPEL is required, but no
COMPEL command has been received within the last two minutes.
Off
GREEN constant
COMPEL is not required and not received within the last two minutes; or, iPump6400 is not in tracking mode.
Current transport stream is protected by conditional access (CA) and iPump6400 is authorized and descrambling.
GREEN slow blink Current transport stream is protected by conditional access (CA) but iPump6400 is unauthorized.
Off Tracked channel is not scrambled.
WARNING
AMBER constant
Off
One or more warning conditions exist. Read warning information from front-panel LCD.
No warning conditions exist.
ALARM
RED constant
RED slow blink
One or more alarm conditions exist. Read alarm message from
LCD.
Boot Fail Mode. All other LEDs are turned off.
Off No alarm condition exists.
wegener.com
61
iPump6400 User’s Manual
This page intentionally blank
800009-01 Rev. B 62 wegener.com
Chapter 5 Customer Service
5.1 Warranty
The following warranty applies to all Wegener Communications products including the iPump6400 Professional Media Server:
All Wegener Communications products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Wegener Communications' obligation under this warranty is limited to repairing or, at Wegener Communications' option, replacing parts, subassemblies, or entire assemblies. Wegener Communications shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are no other warranties, express or implied, except as stated herein.
5.2 Technical Support
If the unit should fail to perform as described, if you need help resolving problems with your iPump6400, or for questions about obtaining service for your iPump6400, please contact Wegener Communications Customer Service at
(770) 814-4057, FAX (678) 624-0294, or E-mail [email protected].
To return a product for service: a) Obtain a Return Material Authorization (RMA) number by completing and faxing a copy of the RMA Request Form to (678) 624-0294. You may E-mail the same information instead to: [email protected]
b) To help us identify and control returned units, plainly write the RMA number on the outside of the product-shipping container. This will help us return your unit to you as quickly as possible.
c) Return the product, freight prepaid, to the address below:
Service Department RMA# ________
Wegener Communications, Inc.
359 Curie Drive
Alpharetta, GA 30005
NOTE: All returned material must be shipped freight prepaid. C.O.D. shipments will not be accepted.
wegener.com
63 800009-01 Rev. B
iPump6400 User’s Manual
This page intentionally blank
800009-01 Rev. B 64 wegener.com
wegener.com
Index
A
Access address
manual comments or questions
alarms contact closure for loss of carrier
B
C
Access
Compel
MediaPlan
connections ac power
audio output
auxiliary audio output connector details
contact closure/
LAN
RF input
video output
Current Channel settings 40, 42, 43
D
E
regarding manual
F
fax number
manuals
files downloading
naming
playing purging
recording
functions
Contact Closure/
File Management
File Play
Files Served to LAN
HTML Control
live program play
play recorded program
record program
unit software switch
G
H
I
L
meaning of
local control disabled
M
menus heirarchy diagram
IP Address
Navigation
Record Setup
65 800009-01 Rev. B
iPump6400 User’s Manual
SNR Alarm/Warning
Setup
Unit Label Setup
Unit Software Switch
model number options indicated by
mounting equipment rack
O
operation from web browser front-panel
P
parameters
phone number
pinouts
LAN connector
playing live program stored file
power ac input
DC to LNB switch
R
RF setup
initial
S
screens menu
user-input
settings current channel
downlink frequency transport data rate
program number
RF-mod/FEC ratio
software switch 58 software version 58
startup initial normal
web browser
stop
T
temperature, ambient operating 20
U
V
video compression 14 video output 14
W
web page
Decoder Settings
opening
Satellite Receive
Status
Welcome
800009-01 Rev. B 66 wegener.com
Download
Advertisement
Key features
Digital satellite receiver
MPEG and IP digital transmission
Media management and server storage
Secure MPEG and IP digital transmission
Receive, decode, and play out broadcast-quality transmissions
Receive from satellite and record multiple programs
Record and play functions
File management
Scheduled operation
Frequently asked questions
The iPump6400 is an integrated, digital satellite receiver, decoder, and media server designed to deliver and store digital content.
The iPump6400 features include receiving, decoding, and playing out broadcast-quality transmissions, recording multiple programs, and file management.
The iPump6400 decodes an incoming DVB MPEG program from the received satellite signal. It decrypts and decodes the audio and/or video from the selected program through analog or digital output ports to your monitor or transmission equipment. The incoming content may be either a 'classical' DVB program or an IP multicast stream.