Wegener iPUMP 6400 User's Manual
विज्ञापन
विज्ञापन
iPump 6400
Professional Media Server
iPump 6400
Professional Media Server
User’s Manual
800009-01 Rev. J
iPump 6400 User’s Manual
Data, drawings, and other material contained herein are proprietary to Wegener
Communications, Inc., and may not be reproduced or duplicated in any form without the prior written permission of Wegener Communications, Inc.
The information contained herein is subject to change without notice. Revisions may be issued to advise of such changes and/or additions.
WEGENER
!
, COMPEL CONTROL
!
, MEDIAPLAN
!
, ENVOY, UNITY
!
, UNITY·IP
!
, and iPUMP
!
are trademarks of Wegener Communications, Inc. All other trademarks are the property of their respective owners.
" 2007 Wegener Communications, Inc. All rights reserved.
Portions copyright 1992-2001 FairCom Corporation. "FairCom" and "c-tree plus" are trademarks of FairCom Corporation and are registered in the United States and other countries. All Rights Reserved.
Correspondence regarding this publication,
800009-01 Rev. J
Ninth Edition: August 2007 should be forwarded to:
Wegener Communications, Inc.
Technology Park/Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Phone: 770-814-4000
Fax: 770-623-0698
The WEGENER iPump 6400 is approved under FCC Part 15B Class A, UL1950, CSA, and
CE.
ii 800009-01 Rev. J www.wegener.com
T
ABLE OF
C
ONTENTS
iPump 6400 User’s Manual
L IST OF F IGURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VII
L
IST OF
T
ABLES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IX
C HAPTER 1 G ENERAL I NFORMATION
1.1 Manual Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.2 iPump 6400 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Physical Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Functional Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Status Monitoring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Live Program Play. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Record Program to File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Play Recorded Program File. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
File Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Playlists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Routing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Stream Creation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Scheduled Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
File Downloads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Files Served to LAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Compel Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
HTML Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Contact Closure/Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 iPump 6400 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 iPump 6400 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
1.4 Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
1.5 Glossary of Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
C HAPTER 2 I NSTALLATION
2.1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
2.2 Location and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Elevated Operating Ambient . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Reduced Air Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Mechanical Loading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Circuit Overloading . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
www.wegener.com
800009-01 Rev. J iii
Reliable Earthing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Rack Installation Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
2.3 iPump 6400 Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Alarm Connector Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Ethernet/LAN Port Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Optional Decoder with Digital Output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Pro Audio Decoder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Multiswitch Connection Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
C HAPTER 3 O PERATION
3.1 Operation Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
3.2 Front-panel Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Liquid-Crystal Display (LCD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Push Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
User Input Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Editable Data Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Editable Filename Field . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Selectable Fields . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
3.3 Startup/Shutdown Procedures. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Initial Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Normal Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Normal Startup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Web Browser Operations Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Static vs. dynamic setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Web Browser Access. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
3.4 Front Panel Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
LCD Menu Navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
3.5 Front Panel Initial Unit Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Pre-configured Transport In Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Navigation to Transport In Setup Screen. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Transport In Current Channel Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
LNB Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
LNB DC Power Setting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
3.6 Front Panel Additional Unit Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Navigation to Date/Time Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Date/Time Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Navigation to Unit Label Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Unit Label Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Navigation to HTTP Proxy screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
HTTP Proxy IP and Port Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 iv 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
www.wegener.com
Navigation to Return Path screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Return Path Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
3.7 Optional Front Panel Screens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Navigation to Modem Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Modem Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Navigation to Genlock Setup Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Genlock Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Navigation to SMB Screen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
SMB Screen Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Screen Park Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
3.8 Web Browser Initial Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Access the Setup Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Decoder Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Genlock Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
User State vs. Current State . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Satellite Receive Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
IP Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
LNB Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
SNR Alarm Warnings Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Date / Time Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
Modem Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Network Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Return Path Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 iPump 615 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
3.9 iPump 6400 Operations by Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Monitor iPump 6400 Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
Monitor Alarm and Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Live Program Play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Checklist for Live Program Play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
Procedure for Live Program Play . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Record Program to File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Procedure for Recording a Program to File . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Play Recorded Program File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48
File Management. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49
File Streaming and Routing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Scheduled Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Playlist Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
About Playlists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Playlist styles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Looping Styles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Random and sequential tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Playlist Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Procedures for opening, creating, saving, and deleting playlists . . . . . . . . . . 54
Opening a playlist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Creating a playlist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
800009-01 Rev. J v
Saving a playlist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Deleting a playlist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Procedures for editing playlists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Navigating the Asset List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Adding items to a playlist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Deleting items from a playlist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Moving items in a playlist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Navigating large playlists. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Playlist pages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Procedures for customizing playlists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Editing the Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Creating and deleting Aliases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Adding on-screen graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Setting a start time for a playlist. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 iPump 6400 Help . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
3.10 Unit Software Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Software Switch Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Verify Software Version Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
C HAPTER 4 M AINTENANCE AND T ROUBLESHOOTING
4.1 Maintenance. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
4.2 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
No Functions At All . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
No Output. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
Trouble Using Browser Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
Fault (Alarm/Warning) Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
C HAPTER 5 C USTOMER S ERVICE
5.1 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
5.2 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
I
NDEX
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 vi 800009-01 Rev. J www.wegener.com
L
IST OF
F
IGURES
iPump 6400 User’s Manual
Figure 1.1: iPump 6400 routing ....................................................................................3
Figure 2.1: Proper rack installation for iPump 6400 ..................................................12
Figure 2.2: iPump 6400 rear-panel connector locations ............................................13
Figure 2.3: Digital output decoder connector layout ...................................................15
Figure 2.4: Balanced analog and AES/EBU digital audio connector ..........................16
Figure 2.5: Connectors for the Pro Audio Decoder ...................................................17
Figure 2.6: Typical RF multiswitch .............................................................................17
Figure 3.1: iPump 6400 front panel ............................................................................19
Figure 3.2: iPump 6400 front panel push buttons ......................................................20
Figure 3.3: Editable data field ..................................................................................20
Figure 3.4: Editable filename field .............................................................................21
Figure 3.5: Selectable field .......................................................................................21
Figure 3.6: iPump 6400 front panel LED indicators. ..................................................21
Figure 3.7: iPump 6400 web browser control setup process ...................................24
Figure 3.8: iPump 6400 web browser Status tab ......................................................25
Figure 3.9: iPump 6400 LCD menu structure ............................................................26
Figure 3.10: LCD menu navigation to Transport In Setup screen ...............................27
Figure 3.11: Menu navigation to set Transport In Current Channel ............................28
Figure 3.12: Menu navigation to set LNB type ............................................................29
Figure 3.13: Menu navigation to set LNB DC power ...................................................29
Figure 3.14: LCD Menu navigation to Date/Time Setup screen ...................................30
Figure 3.15: LCD menu navigation to Set Unit Label screen .......................................31
Figure 3.16: LCD menu navigation to HTTP Proxy screens ........................................32
Figure 3.17: LCD menu navigation to Return Path screen ..........................................33
Figure 3.18: LCD menu navigation to Modem screen ..................................................34
Figure 3.19: LCD menu navigation to Genlock screen ................................................35
Figure 3.20: LCD menu navigation to SMB screen ......................................................35
Figure 3.21: iPump 6400 web browser Setup tab .....................................................37
Figure 3.22: iPump 6400 web browser Status tab ......................................................44
Figure 3.23: iPump 6400 web browser Rec/Play tab ...................................................47
Figure 3.24: iPump 6400 web browser Files tab ..........................................................50
Figure 3.25: iPump 6400 web browser Streams tab ....................................................51
Figure 3.26: iPump 6400 web browser Schedule tab ..................................................52
Figure 3.27: iPump 6400 web browser Playlist tab ....................................................53
www.wegener.com
800009-01 Rev. J vii
iPump 6400 User’s Manual
Figure 3.28: Large Playlist Navigation tools .................................................................57
Figure 3.29: iPump 6400 web browser Help tab ..........................................................60
Figure 3.30: Menu navigation to switch unit software .................................................60
Figure 3.31: Menu navigation to Version Info ..............................................................61
viii 800009-01 Rev. J www.wegener.com
L
IST OF
T
ABLES
iPump 6400 User’s Manual
Table 1.1:
Table 1.2:
Table 1.3:
Table 2.1:
Table 2.2:
Table 2.3:
Table 2.4:
Table 2.5: iPump 6400 options key ............................................................................4
iPump 6400 technical specifications i ........................................................6
Glossary of terms and abbreviations .........................................................8
iPump 6400 connector details ..................................................................14
iPump 6400 Alarm connector pin functions ............................................15
iPump 6400 LAN connector pin functions ................................................15
Digital output decoder connectors ........................................................16
Balanced analog and AES/EBU digital audio connector pin functions ....16
Table 2.6:
Table 3.1:
Table 3.2:
Table 3.3:
RF port selection signals .........................................................................17
iPump 6400 front panel LED indicator descriptions .................................22
iPump 6400 web browser control setup procedure ..................................24
iPump 6400 pre-configured Transport In Settings ...................................27
Table 3.4:
Table 3.5:
Table 3.6:
Menu navigation to Transport In Setup screen ........................................27
Procedure for adjusting Transport In Current Channel settings ...............28
Procedure for setting LNB LO Frequencys .............................................29
Procedure for setting LNB DC power .......................................................29
Table 3.7:
Table 3.8:
Table 3.9:
Procedure for setting Date/Time parameters ...........................................30
Procedure for entering iPump 6400 Unit Label ........................................31
Table 3.10: Procedure for adjusting HTTP Proxy settings ..........................................32
Table 3.11: DVB programs ........................................................................................45
Table 3.12: Large Playlist Navigation .........................................................................57
Table 3.13: Procedure for switching iPump 6400 software version ............................61
Table 4.1: iPump 6400 LED indicator descriptions ...................................................64
www.wegener.com
800009-01 Rev. J ix
iPump 6400 User’s Manual x 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
C
HAPTER
1 G
ENERAL
I
NFORMATION
1.1 Manual Overview
This manual provides instructions and reference information for the proper installation and operation of the WEGENER iPump 6400 Professional Media Server, referred to throughout the manual as the iPump 6400.
This manual is divided into these chapters:
Chapter 1 General Information -a description of the iPump 6400, its functions and specifications, and a glossary of terms.
Chapter 2 Installation - procedures and information for the correct and safe installation of the iPump 6400.
Chapter 3 Operation- instructions on starting and operating the iPump 6400.
Chapter 4 Maintenance and Troubleshooting - information on maintaining the
iPump 6400 and resolving possible operating difficulties.
Chapter 5 Customer Service - our warranty and information on obtaining help.
Index - list of keywords to help you quickly locate information.
Please e-mail any suggestions or comments concerning this manual to
[email protected]. If you prefer to post through the mail, please send your comments to the address below. If you have substantial or complex changes to recommend, our preference is that you copy the page(s) in question, mark your changes on that copy, and fax or mail us the copy. We always appreciate constructive criticism.
Our Address:
Attn: Manuals
Wegener Communications, Inc.
Technology Park / Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Our fax number:(770) 497-0411
1.2 iPump 6400 Overview
The WEGENER iPump 6400 is an integrated, digital satellite receiver, decoder, and media server designed to provide the most cost effective method of delivering and storing digital content for broadcast, cable, and business operations. The iPump 6400 is a key part of the
Wegener Communications Digital Media Delivery System which combines secure MPEG and IP digital transmission with media management and server storage. At a given time, up to 260 hours of media content can be stored on a single iPump 6400 (with optional, large disk capacity) and served out via Ethernet according to current need or predetermined schedules.
With the iPump 6400, you can receive, decode, and play out broadcast-quality transmissions while at the same time receiving from satellite and recording multiple
www.wegener.com
800009-01 Rev. J 1
General Information
Physical
Description
Functional
Description
programs or IP data files. Combined with our Compel MediaPlan software, the iPump 6400 can also place spot segments into real-time or recorded programs and can schedule playback of custom sequences of live and recorded content.
The iPump 6400 is housed in a standard, 2 RU, rack-mountable chassis. Its front panel provides a user interface through an LCD and six push buttons (see Figure 3.1: iPump 6400
front panel on page 19). The rear panel holds the power switch and the ports that allow connection to power, incoming signal, and peripheral devices.
The iPump 6400 can perform the following functions:
Status Monitoring
Front-panel and web browser interface screens allow real-time monitoring of iPump 6400 activity, settings, and signal characteristics.
Live Program Play
The iPump 6400 decodes an incoming DVB MPEG program from the received satellite signal. It decrypts and decodes the audio and/or video from the selected program through analog or digital output ports to your monitor or transmission equipment. The incoming content may be either a "classical" DVB program or an IP multicast stream. RF and decoder settings are selected by the user. Two live programs from the same DVB carrier may be played simultaneously by iPump 6400s that have the optional second decoder.
Record Program to File
The iPump 6400 can simultaneously record up to three separate multiplexed programs
(either "classical" DVB or IP multicast stream) from the incoming stream including any that are played live to the decoder(s). The user selects the programs and enters a file name, audio setting, and a recording time (duration) for each. Files are recorded to disk in the
iPump 6400 for later play-out or downloading. Up to 40 GB of storage (up to 43.3 hours of programming depending on data rate) is available on standard iPump 6400s and up to 240
GB on optional, extended-storage iPump 6400s (see Disk Storage Capacity on page 5).
Record and play functions can be used in such applications as "tape delay"/time zone shifting, "spot" localization of commercials, and corporate training media distribution.
Play Recorded Program File
The iPump 6400 plays out the selected, stored program files to the connected audio and video monitors. File playing may be initiated by a predetermined schedule via Compel or by a schedule stored internally to the iPump 6400. The user may also command playing of files directly from a web browser or from the front panel. Two recorded programs (or one recorded and one live) may be played simultaneously on iPump 6400s with an optional second decoder.
File Management
Compel users can rename or delete files stored on the iPump 6400 and organize them into directories or folders. Renaming and deleting files may also be performed through a web browser connected to the iPump 6400 over a LAN.
Playlists
Sequences of programs called playlists can be created and stored on the iPump 6400 by the user (locally or by Compel). Up to 2,000 playlists can be stored in nonvolatile memory and played back with no interruption between programs. Settings can be made to repeat the
2 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual playlist indefinitely, complete the playlist and repeat only the last program indefinitely, or complete the playlist and simply return the decoder to its previous state.
Routing
The iPump 6400 can serve as a satellite-to-LAN IP router. Both unicast and multicast IP traffic is supported. Multicast traffic can include, for example, MPEG video streaming data.
The IGMP protocol is followed for multicast traffic.
Stream Creation
The iPump 6400 can create IP multicast video streams and present them on the LAN for use by other equipment. The source of the video stream may be either a prerecorded or downloaded file or a "classical" DVB program.
The iPump 6400 can also multicast previously-stored streams to the LAN. See Figure 1.1:
iPump 6400 routing for an illustration of iPump 6400 routing paths.
Figure 1.1: iPump 6400 routing
www.wegener.com
Scheduled Operation
Schedules of record, play, and other operations for automatic execution by the iPump 6400 may be set up using the Compel network and may be viewed from the web browser interface. (Schedule operations support wild cards and ranges in day, date, and time fields for repetitive events.)
File Downloads
The iPump 6400 accepts files downloaded from the satellite link via Compel’s Assured File
Delivery package. Application software and other files may also be downloaded. Up to five downloads may be performed simultaneously up to an aggregate data rate of 25 Mbps.
The iPump 6400's file download and record functions may be used to load the unit with content for playout (according to a pre-arranged schedule if desired) at any time. This can
800009-01 Rev. J 3
General Information
iPump 6400
Options
be particularly useful in applications with extended or continuous playout needs and limited satellite operating times.
Files Served to LAN
Users sharing a LAN with the iPump 6400 may download stored files from the iPump 6400 to their local workstation or server using FTP or SMB protocol.
Compel Control
iPump 6400 operation may be controlled remotely by a Compel network. Compel
Conditional Access controls which iPump 6400s may access the satellite’s material and prevents access by any other receive equipment. Local control of the unit may be disabled for exclusive control by Compel. The iPump 6400 always follows the most recent command received and does not prioritize commands based on origination from the front panel, web browser interface, or Compel network.
HTML Control
Control of the iPump 6400 is available from any web browser on the LAN to which it is connected or via the internet if desired. The IP address and subnet mask can be displayed and changed at the iPump 6400 front panel.
Contact Closure/Alarms
The iPump 6400 provides a contact closure through a rear-panel connector whenever the unit enters an alarm condition. An additional user relay is also available. The iPump 6400 can also sense a contact closure input. Using Compel, file playouts can be triggered by local closure of this input.
The iPump 6400 Professional Media Server is available in several configurations to meet specific applications. Input type, decoder type, disk storage capacity, Conditional Access, and the presence of a second decoder can be varied to create models best suited for your specific needs.
The iPump 6400 model number is structured as follows to describe the options on each
iPump 6400: IP - ABC - D - EF - G - HH - JKK
Table 1.1 lists the options in each equipment category.
Table 1.1: iPump 6400 options key
Model Number
Position
IP
A
Option Name Designator Description
This prefix simply indicates that the unit is an iPump .
First Decoder Type
(top slot)
0 - No decoder
1 - Basic decoder
2 - professional 4:2:0 decoder with analog outputs
3 - professional 4:2:2 decoder with analog outputs
4 - professional 4:2:2 decoder with digital outputs
5 - professional audio output
6 - professional 4:2:0 decoder with analog outputs and channel 3-4 modulator connector
4 800009-01 Rev. J www.wegener.com
www.wegener.com
iPump 6400 User’s Manual
Model Number
Position
B
C
D
E
F
G
HH
J
KK
Type
Option Name
Second Decoder Type
(middle slot)
Input Type
(bottom slot)
Disk Storage Capacity
Contact Closure Module
Channel 3-4 Modulator
Designator Description
0 - No second decoder
1 - Basic decoder
2 - professional 4:2:0 decoder with analog outputs
3 - professional 4:2:2 decoder with analog outputs
4 - professional 4:2:2 decoder with digital outputs
5 - professional audio output
6 - professional 4:2:0 decoder with analog outputs and channel 3-4 modulator connector
1 - DVB RF Input
2 - ASI Input
1 - 40 Gigabytes
2 - 80 Gigabytes
3 - 120 Gigabytes
4 - 160 Gigabytes
5 - 200 Gigabytes
6 - 240 Gigabytes
1 - Alarm and contact closure in and out on DB-9
2 - Alarm and contact closure in and out on DB-9, plus RJ-11 internal modem
0 - none
1 - present
Reserved
Conditional Access Type
Line Cord
(power connector)
Other
1 - U.S.
2 - U.K.
3 - Europe
4 - Australia
00 - none
01 - Aux Audio
02 - KenCast FEC
03 - KenCast FEC plus
Aux Audio
04 - OSD
05 - OSD plus
Aux Audio
06 - OSD plus
KenCast FEC
07 - OSD plus
KenCast FEC plus
Aux Audio
800009-01 Rev. J 5
General Information
1.3 iPump 6400 Specifications
Technical
Specifications
Table 1.2: iPump 6400 technical specifications i
Characteristic Specification
RF
Input Frequency
Input FrequencyRange
Input Impedance
LNB Power
Tuning Resolution
Modulation
Transport Rate Range
Video Compression
Video Data Rate
Compression Type
Horizontal Resolution
Vertical Resolution tuning via front panel control or Compel
950 to 2150 MHz
75 ohms
250 mA max, 22 kHz tone control vertical polarity: 12.4 to 14.0 VDC horizontal polarity: 17.0 to 19.0 VDC
1 kHz
QPSK
2.0 to 45 Msps up to 15 Mbps per service
MPEG 4:2:0 or 4:2:2
720, 704, 640, 544, 480, 352
480 lines @ 30 Hz (NTSC)
240 lines @ 30 Hz (NTSC)
576 lines @ 25 Hz (PAL)
288 lines @ 25 Hz (PAL)
Video Output
Video Format
Output Level
Output Impedance
Audio Compression
Compression Type
Data Rate
Output Modes Supported
Audio Output
Frequency Response
NTSC/PAL composite and SDI (with embedded audio)
1 Vpp ± 5%
75 ohms
MPEG Layer II
64 to 384 kbps
Mono, Dual Mono, Joint Stereo
20 Hz to 20 kHz
6 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Characteristic
General
Power Supply
Specification
100 to 120 V or 200 to 240 V (auto switches)
60/50 Hz
5.0/2.5 A
Size weight height width
~20 pounds (9.1 kg)
3.5 inches (90 mm)
19 inches (483 mm)
[17 inches (432 mm) with mounting ears removed]
16"(406 mm) depth
Environmental
Use
Operating Temperature
Altitude
Humidity
Indoor only
+10° C to +40° C
Less than 2000 meters
Maximum relative humidity of 80% for temperatures up to 31° C decreasing linearly to 50% relative humidity at
40° C.
1.4 Safety Summary
The iPump 6400 is designed for safe use with few special precautions required of the user.
The following items are basic precautions to use when installing and working with your
iPump 6400:
Do not open the iPump 6400's chassis cover.
www.wegener.com
800009-01 Rev. J 7
General Information
1.5 Glossary of Terms and Abbreviations
Table 1.3: Glossary of terms and abbreviations
Term Definition
AC
Alarm
AFD
Authorized
Carrier
Compel
!
CA
Alternating current
A condition or notification of a condition that prevents the iPump 6400 from performing properly.
Assured File Delivery.
Describes an iPump 6400 which has the ability through Compel Conditional Access to decrypt programs encrypted by the Compel software.
An RF signal containing coded audio, video, and/or other data.
WEGENER 's network control software that may be used to manage a number of iPump 6400 s and other hardware.
Conditional Access. The means by which Compel controls which iPump 6400 s may decrypt specially encrypted audio, video, or data streams.
PAT
PID
PMT
PPP
DVB
EIA
Eb/No
Ethernet
FTP
GB
Digital Video Broadcast
Electronic Industries Association
The ratio of Energy per Bit (Eb) to the Spectral Noise Density (No).
The widely-used LAN technology specified by IEEE standard 802.3
File transfer protocol
Gigabyte or 2
30
bytes
Institute of Electrical and Electronics Engineers IEEE
LAN Local area network. The iPump 6400 may be connected to an Ethernet LAN.
LCD Liquid crystal display. The front-panel text screen on the iPump 6400 is a liquid crystal display.
LED
LNB
Light-emitting diode. The front-panel indicator lights on the iPump 6400 are LEDs.
Low-noise block downconverter - equipment (generally at the antenna) that converts the incoming satellite signal to the appropriate frequency for reception by the iPump 6400 .
Mbps, kbps or Msps Units of data transport rate - Megabits per second (1 million bits per second), kilobits per second (1 thousand bits per second), or million symbols per second (1 million symbols per second).
MPEG Moving Picture Experts Group - refers to the method of video compression established by this group.
OSG On-screen graphic. A watermark-like station logo that television broadcasters overlay over a portion of the screen-area of their programs. Also referred to as "bugs" and are commonly displayed on the bottom right corner of the screen.
Program
Program Association Table
Packet ID. Identifies audio/video streams in DVB broadcasting
Program Map Table
PPP (Point-to-Point Protocol) is a protocol for communication between two computers using a serial interface, typically a personal computer connected by phone line to a server.
A single media stream (audio, video, data, etc.) tied to a common time base.
8 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Term
Program Number
QPSK
RF
SMB
T
MRA
Warning
Definition
A numerical code representing a program.
Quadrature phase shift keying. QPSK is a digital frequency modulation technique used for sending data over coaxial cable networks.
Radio frequency
Server message block - a protocol for requesting services from and reading and writing to a file server.
Maximum Recommended Ambient Temperature, the highest operating temperature for which the unit is rated.
A condition or notification of a condition that may compromise the proper performance of the iPump 6400 .
www.wegener.com
800009-01 Rev. J 9
General Information
This page intentionally left blank
10 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
C
HAPTER
2 I
NSTALLATION
This chapter provides instructions on unpacking, mounting, and connecting the iPump 6400 as well as connector information including detailed pinouts.
2.1 Unpacking and Inspection
Carefully unpack the unit and its ac power cord and inspect for obvious signs of physical damage that might have occurred during shipment. Also locate the bag of accessories including 1/8-to-RCA and SVD-to-RCA adapters. Any damage claims must be reported to the carrier immediately. Be sure to check the package contents carefully for important documents and materials.
Note: Please save the packing materials and original shipping containers in case you must later return the unit for repair. Packing these units in other containers in such a way that they are damaged will void your warranty.
2.2 Location and Mounting
The iPump 6400 should be mounted in a standard 19-inch equipment rack. After mounting, maintain a clean, dry environment for the unit.
Precautions
WA RNING This is a Class A product. In a domestic environment this product may cause radio interference for which the user may need to take mitigating action.
DANGE R To avoid damage to this and other equipment, or personal injury, the following items should be strictly observed.
Elevated Operating Ambient
When equipment is installed in a closed or multi-unit rack assembly, the operating ambient temperature of the rack environment may be greater than the room ambient temperature.
Therefore, consideration should be given to the ambient air temperature within the rack, and not just inside the room, when deciding if the maximum recommended ambient operating temperature (T
MRA
) is being met.
Reduced Air Flow
Equipment should be installed such that airflow required for safe operation of the equipment is not compromised. To ensure adequate air flow, the iPump 6400 should be arranged in a rack with at least one empty rack unit between it and adjacent equipment and with adequate clearance around both side vents.
Mechanical Loading
Mounting of the equipment in a rack should be such that a hazardous condition is not produced by uneven loading. This unit is not very heavy, but total rack loading must be considered. Also, do not rest any unsupported equipment on your iPump 6400.
www.wegener.com
800009-01 Rev. J 11
Installation
DANGE R Circuit Overloading
Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits could have on overcurrent protection and supply wiring. Ensure that the total rack or breaker power consumption does not exceed the limits of the ac branch circuit. Appropriate consideration of equipment ratings should be used when addressing this concern.
Reliable Earthing
Reliable earthing of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit
(use of power strips, chassis ground lugs, etc.).
Rack
Installation
Procedure
The iPump 6400 is sized at 2 RU and will fit an EIA-standard, 19-inch-wide equipment rack.
1. First, install angle brackets or cross-supports capable of supporting both the unit and its connecting cables. Screw or bolt the supports securely to the equipment rack.
2. Place the iPump 6400 on its supports and use four anchor screws or bolts and nuts to secure the unit's front brackets to the rack.
WA RNING A 1 RU gap (1.75 in) must be left between the iPump 6400 and any adjacent equipment above or below it to provide adequate air flow around the unit. Do not block over 50% of the ventilation or fan opening on each side of the unit. Support arrangements that do not allow adequate air flow or that block over half of the opening on either side may result in overheating and damage to the iPump 6400.
WA RNING The front brackets must be secured to the rack. If front brackets are left unsecured, the unit may shift forward and fall from the rack during installation or operation. Failure to secure the front brackets may result in personal injury and/or damage to the equipment.
WA RNING Locate the iPump 6400 and its cables to avoid impacts, spills, and pulling cables and to ensure sufficient air flow. Failure to locate the iPump 6400 in a proper environment may result in damage to the equipment.
Figure 2.1: Proper rack installation for iPump 6400
12 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
2.3 iPump 6400 Connections
Before applying power, make the following connections to your iPump 6400. Refer to
Table 2.1 on page 14 for connector details and to Figure 2.2: iPump 6400 rear-panel
connector locations for placement.
Figure 2.2: iPump 6400 rear-panel connector locations
www.wegener.com
1. Connect the L-band output from your antenna's LNB or from your multiswitch to the extender cable on your iPump 6400's input RF port [ a ]. (A BNC connector is used here for
iPump 6400s with the ASI input option.)
2. Connect a suitable audio monitor or monitors to the iPump 6400's audio port(s) [b1] (on both decoders if your iPump 6400 includes a second decoder). Also connect audio monitoring to the auxiliary audio port [b2] if your iPump 6400 includes that option. See
Table 2.1.
Note: See Figure 2.3: Digital output decoder connector layout on page 15 for an illustration and audio/video connector details if your iPump 6400 is equipped with an optional decoder with digital outputs.
3. Connect a suitable video monitor or monitors to the iPump 6400's video port [ c ] (on both decoders if your iPump 6400 includes a second decoder). (See Table 1.1: iPump 6400
options key on page 4.)
4. Connect your LAN line to the iPump 6400's Ethernet port [ d ]. (Refer to Table 2.3: iPump
6400 LAN connector pin functions on page 15.)
5. If desired, connect the Alarm port [ e ] to your equipment to provide contact closures and openings during alarms or on command from Compel. (Refer to Table 2.2: iPump 6400
Alarm connector pin functions on page 15.)
6. Finally, connect the supplied ac power cord to the iPump 6400's IEC receptacle [ f ] and to a
100-to-120 Vac or 200-to-240 Vac source.
Note: Do not connect devices to the mouse, keyboard, and other connectors not described here. They are for factory use only.
800009-01 Rev. J 13
Installation
Table 2.1: iPump 6400 connector details
Designation Connector Type Signal Description Additional Information
RF IN female Type F 950 to 2150 MHz RF carrier from antenna LNB
A extension cable is shipped already attached to the RF IN port to allow easier access for attaching your RF input.
ASI IN
AUDIO* female BNC ASI input signal
1/8-inch stereo jack Audio output
Only on iPump 6400 s with the ASI input option.
A 1/8-to-RCA adapter is shipped with your iPump 6400 (one for each active audio decoder).
Can be "slaved" to decoder 1 or decoder 2 AUX AUDIO 1/8-inch stereo jack Audio output
VIDEO*
LAN
CONTACT
CLOSURE/
ALARM
POWER
Mini-DIN4 or BNC female RJ-45 male DB-9
Video output
10/100baseT Ethernet
Contact closure/opening in and out
A Mini-DIN4-to-RCA adapter is shipped with your iPump 6400 . Units equipped with the optional, professional 4:2:2 decoders will have a female BNC connector.
Autosensing; see pinout detail in Table 2.3: iPump 6400 LAN connector pin functions on page 15
See pinout detail in Table 2.2: iPump 6400
Alarm connector pin functions on page 15
Male IEC receptacle
100-to-120 Vac @60 Hz or
200-to-240 Vac @ 50 Hz
Autoswitching
* See connector details under Optional Decoder with Digital Output on page 15 if your iPump 6400 is equipped with a digital output decoder.
Alarm
Connector
Details
The DB-9 female alarm connector on the rear panel provides contact closures and openings during alarm conditions as well as a user relay available for control by Compel command
(USER CC). Normal conditions represent the contact in normally functioning, powered operation. Other conditions or commands will reverse the status of the contact from its normal position.
Pin functions of the DB-9 alarm connector are listed in Table 2.2. Pin 1 is the common connection used by both pins 2 and 6. In alarm mode, Pins 1 and 2 are connected together.
When not in alarm mode, Pins 1 and 6 are connected together.
!" Pins 1 and 2 are normally open and are closed during an iPump 6400 alarm.
!"
Pins 1 and 6 are normally closed and are open during an iPump 6400 alarm.
!"
Pins 3 and 8 on the DB-9 are normally open and may be closed by command from Compel .
!"
Pin 5 is the local, user input (0=trigger).
14 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Table 2.2: iPump 6400 Alarm connector pin functions
Pin Number
7
8
5
6
9
3
4
1
2
Function
Alarm common
Alarm Normally Open
Contact Closure Out Common
No Connection
Contact Closure Input
Alarm Normally Closed
No Connection
Contact Closure Out Normally Open
Ground
Ethernet/LAN
Port Details
The iPump 6400's 10/100baseT ( autosensing) Ethernet port has the following pin functions.
Table 2.3: iPump 6400 LAN connector pin functions
Pin Number
6
7
4
5
8
1
2
3
Name
TX_D1+
TX_D1-
RX_D2+
Unused
Unused
RX_D2-
Unused
Unused
Description
Transmit Data+
Transmit Data-
Receive Data+
Receive Data-
Optional
Decoder with
Digital Output
Connector details are somewhat different for iPump 6400s having the optional decoder with digital audio and video output. Figure 2.3 below illustrates the rear-panel layout of this optional decoder. Connector details are listed in Table 2.4.
Figure 2.3: Digital output decoder connector layout
www.wegener.com
800009-01 Rev. J 15
Installation
Table 2.4: Digital output decoder connectors
Ref Number
3
4
1
2
Connector Type
BNC
BNC
BNC
DB-15 HD
Signal Description
Serial Digital Video Out
Composite Video Out
Genlock Reference In (Not currently supported)
Balanced Analog Audio and AES/EBU Digital Audio Out
Pinout details for the balanced analog and AES/EBU digital audio connector are shown in
Figure 2.4 and Table 2.5 below.
Figure 2.4: Balanced analog and AES/EBU digital audio connector
Pro Audio
Decoder
Table 2.5: Balanced analog and AES/EBU digital audio connector pin functions
Pin Number
7
8
5
6
3
4
1
2
Function
Analog Ch B (Left +)
Analog Ch A (Left -)
Ground
Analog Ch B (Right +)
Analog Ch A (Right +)
Analog Ch B (Left -)
Analog Ch A (Left +)
Ground
Pin Number
13
14
15
9
10
11
12
Function
Analog Ch B (Right -)
Analog Ch A (Right -)
Ground
AES Ch B +
AES Ch B -
AES Ch A -
AES Ch A +
The output connectors for the professional audio model of the iPump 6400 look somewhat different than the standard video decoder connectors. The iPump 6400 Pro Audio Decoder allows streams of different sample-rates and formats to be mixed together and sent to both analog and digital AES/EBU outputs. Synchronization capabilities include an AES/EBU sync input and Word clock input and output. Special cables are required for connection to both the analog and digital outputs. Pinout details for the Pro Audio Decoder connectors are shown in Figure 2.5 below.
16 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Figure 2.5: Connectors for the Pro Audio Decoder
Multiswitch
Connection
Details
When operating a multiswitch, use Table 2.6 to identify the line signals corresponding to each iPump 6400 RF port selection. On a typical multiswitch (as in Figure 2.6 below), these ports will be in order from left to right as viewed from the side holding the input connectors.
Table 2.6: RF port selection signals
Port Number
1
2
3
4
Signal
13V with 22 kHz tone
18V with 22 kHz tone
13V without tone
18V without tone
Figure 2.6: Typical RF multiswitch
www.wegener.com
800009-01 Rev. J 17
Installation
This page intentionally left blank
18 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
C
HAPTER
3 O
PERATION
3.1 Operation Overview
Most routine iPump 6400 operations are performed over the Compel network or locally through the web-browser interface. However, front-panel control is required to switch the unit’s software (see 3.10 Unit Software Switch on page 60) or to change some key unit settings such as IP address, unit label, LNB LO value, and alarm/warning thresholds. It is important to remember that while most operations are performed remotely, the
iPump 6400 does not prioritize incoming commands based on which interface is used. The
iPump 6400 treats commands from the front panel with importance equal to commands from both the Compel network and the browser interface. Commands are prioritized based only on the order in which they are received. The first command received is the first one performed. Of course, when local control is disabled by command from Compel, no local control is possible until re-enabled by Compel.
In addition to introducing and describing the front-panel and web browser interfaces, this chapter provides details on startup/shutdown of the iPump 6400, making initial unit settings for basic operation, and performing tasks over the web browser. The chapter is organized into the following sections:
!" 3.2 Front-panel Controls and Indicators ,
!" 3.3 Startup/Shutdown Procedures ,
!" 3.4 Front Panel Operation ,
!" 3.5 Front Panel Initial Unit Setup ,
!" 3.8 Web Browser Initial Setup ,
!" 3.9 iPump 6400 Operations by Function , and
!" 3.10 Unit Software Switch .
Note: When operated as part of a Compel network, the iPump 6400 may at times become unavailable for local control or may perform functions not commanded locally. For example, the Compel network operator may command remote iPump 6400s to disable local control during a particular broadcast or program schedule. Also, if set up to expect Compel commands, the iPump 6400 may begin searching RF channels for a Compel signal if that signal is temporarily lost.
3.2 Front-panel Controls and Indicators
There are three major parts of the iPump 6400's front panel controls and indicators: the liquid-crystal display (LCD), the six push buttons, and the eight LED indicators.
Figure 3.1: iPump 6400 front panel
LCD push buttons
www.wegener.com
LED indicators
800009-01 Rev. J 19
Operation
Liquid-Crystal
Display (LCD)
The iPump 6400's LCD indicates unit status and prompts for and reflects user input. The
LCD displays the iPump 6400's unit label and serial number on the top line following startup.
The home screen also alternately displays the input signal’s frequency, data rate, and FEC ratio in the lower left corner and continuously displays the current signal-to-noise ratio in the lower right. Using the adjacent push buttons you can navigate the iPump 6400's various screens and edit data fields on the user-input screens.
Push Buttons
These six push buttons are your means of commanding the iPump 6400 from the front panel. The four arrow buttons allow navigation through the menu screens and parameter selection and editing in user-input screens. The ENTER button serves to select menu options (downward navigation), to open user-input fields, or to commit user input to the
iPump 6400. Also press ENTER to quickly start the unit after a normal shutdown. The
Escape (ESC) button allows exit from user-input fields without saving the entry or selection.
ESC also provides upward navigation through the menu structure to the home screen.
Figure 3.2: iPump 6400 front panel push buttons
User Input
Screens
User input screens with editable fields accept data entry by the user. The iPump 6400 has two types of user-input screens:
!"
Editable Fields (data and filename)
!"
Selectable Fields
Note: Front-panel control is limited by a four-minute timeout period. After four minutes without input from the front-panel push buttons, the iPump 6400 LCD automatically returns to the home screen and any unsaved changes are lost.
Editable Data Fields
Figure 3.3 shows an example of a user-input screen with an editable data field.
Figure 3.3: Editable data field
20
To make changes to the data in the field:
1. Press ENTER to open the field. The LCD highlights the first field.
2. Press the up or down arrow buttons to increment that digit or letter until the LCD displays the desired value. Press the right arrow button to move to the next digit or location in the field and change it the same way. Continue until the LCD displays all digits or letters correctly.
3. Press the ENTER button to save your changes. Press ESC before pressing ENTER to cancel any changes.
800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Editable Filename Field
Another type of Editable Field appears when filenames must be entered. Figure 3.4 shows an example of a user-input screen with an editable filename field.
Figure 3.4: Editable filename field
1. Press ENTER to begin spelling the filename. The LCD highlights the letter A in the character list.
2. Press the arrow buttons to move through the character list until the LCD highlights the first character of the filename. Additional characters including numerals, decimal, space, and hyphen appear on the LCD as you move downward through the available characters list.
3. Press ENTER to confirm the first character. The first character is displayed at the bottom left of the LCD.
4. Select additional characters as in steps 2 and 3 until the LCD displays the entire filename at the bottom left of the LCD.
5. When the LCD displays the entire filename, press ESC to stop editing. When prompted,
Done?, press ENTER if the filename is correct or ESC to continue editing your entry.
Selectable Fields
Other user-input screens allow selection from a list of options. Figure 3.5 shows an example of a user-input screen with a selectable field.
Figure 3.5: Selectable field
LED
Indicators
1. Press ENTER to open the field. The current selection starts blinking.
2. To view available options one at a time, press the up or down arrow buttons.
3. To save a selection, press ENTER when the LCD displays the desired option. To cancel any changes, press ESC before pressing ENTER.
These eight light-emitting diodes (LEDs) provide status information about the iPump 6400 and its processes. Table 3.1 on page 22 provides the meaning of the color and state of each
LED.
Figure 3.6: iPump 6400 front panel LED indicators.
www.wegener.com
800009-01 Rev. J 21
Operation
Table 3.1: iPump 6400 front panel LED indicator descriptions
Indicator
Label
Color and State Meaning
CARRIER
RECORD
GREEN constant Receiver is tracking carrier.
GREEN slow blink Receiver is not tracking carrier.
GREEN constant iPump 6400 is recording a program.
Off iPump 6400 is not recording.
DOWNLOAD GREEN constant
Off
LAN iPump 6400 is downloading a file via iPump 6400 is not downloading.
Compel .
GREEN constant Light network activity over the iPump 6400 ’s LAN interface
COMPEL
GREEN slow blink Heavy network activity over the iPump 6400 ’s LAN interface
Off iPump 6400 observed no packet transfers on the LAN interface during the last 20 seconds.
GREEN constant iPump 6400 has received a Compel command within the last two minutes.
GREEN fast blink iPump 6400 has been addressed by Compel within the last five seconds.
GREEN slow blink iPump 6400 is in tracking mode, Compel is required, but no Compel command has been received within the last two minutes.
AUTH
Off Compel is not required and not received within the last two minutes; or, iPump 6400 is not in tracking mode.
GREEN constant Current transport stream is protected by conditional access (CA) and iPump
6400 is authorized and descrambling.
GREEN slow blink Current transport stream is protected by conditional access (CA) but iPump
6400 is unauthorized.
Off Tracked channel is not scrambled.
WARNING*
ALARM*
AMBER constant One or more warning conditions exist. Read warning information from front-panel LCD.
Off
RED constant
Off
No warning conditions exist.
One or more alarm conditions exist. Read alarm message from LCD.
No alarm condition exists.
* When multiple alarm or warning conditions exist, the iPump 6400 displays those conditions in the order of importance with the most critical condition displayed first. To scroll through the alarms, use the right and left arrow buttons on the front panel. !"#
22 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
3.3 Startup/Shutdown Procedures
The first time you start the iPump 6400, the startup process and some initial setup may require a few minutes to complete. After the initial startup, and a normal shutdown, the
iPump 6400 may be started again simply by pressing the ENTER button on the unit’s front panel.
Initial Startup
1. For initial startup, set the power switch to the ON position ( I ) and press and hold the
ENTER button for two seconds. The iPump 6400 powers up and begins the startup process. Usually within three minutes, the unit completes its initialization. (All outputs are muted during this time.)
2. The eight, front-panel LEDs flash on and off together once and then three more times in succession. The LCD shows the current firmware version and the message, "Booting,
please wait. . . .". The expanding and contracting ellipsis shows that the iPump 6400 is booting the software. (Note that the version number shown is that of the front-panel firmware only, and does not indicate the current version of the application software.)
3. During bootup, a quick check of the file system is made to detect and fix any corrupted files.
The message "Auto Maintenance . . ." indicates that this check is in process. The duration of the file system check depends on the extent of any needed repairs to the file system and the size of the affected files. When no problems are detected, the "Auto Maintenance" message briefly flashes on the LCD. If the file system is corrupt beyond repair, the message, "Filesystem is corrupt . . ." appears. Otherwise, the auto maintenance process is continuing normally and you should wait for it to complete.
4. Following a normal check of the file system, the message, "Continuing to boot. . ." is displayed. At completion of bootup, the LEDs lights individually as appropriate to show unit and signal status (see Table 3.1: iPump 6400 front panel LED indicator descriptions on page 22). The display then becomes "live" and typically indicates a loss-of-carrier alarm condition if the unit’s RF configuration has not been completed. This is normal and simply means that the Transport In Settings must be adjusted. After the Transport In Setup is complete, subsequent startups finish by displaying the home screen (showing the unit's serial number, E b
/N
0
, and alternately displaying FEC ratio, signal frequency, and data transport rate). This indicates that your iPump 6400 is functioning normally and is ready for use.
Normal
Shutdown
Normal
Startup
Removing power to shut down the iPump 6400 does not harm the unit. However, performing a normal shutdown from the front panel is recommended. Normal startup can only be performed following a normal shutdown.To shut down the iPump 6400:
1. Return to the iPump 6400 home screen. (Press ESC repeatedly until the model and unit number or an alarm or warning message displays.)
2. Press the right-arrow button four times to reach the Unit Shutdown screen.
3. Press the ENTER button to select Unit Shutdown.When prompted, press the ENTER button again to confirm.
4. In less than 30 seconds, the iPump 6400 powers down and the LCD and LEDs go out. The
iPump 6400 is now ready for a normal startup. Initiate a normal startup by pressing the
ENTER button.
Following initial startup and after a normal shutdown, start the iPump 6400 by simply pressing the ENTER button on the front panel. If the receiver is tracking a carrier signal, the green CARRIER LED is lit. If the RF set up (See Transport In Current Channel Setup on page 27.) has not been performed or the receiver cannot track the carrier, the red ALARM
LED is lit.
www.wegener.com
800009-01 Rev. J 23
Operation
Web Browser
Operations
Startup
For HTML control and status checking from a web browser, first navigate from the home screen to the IP Setup screen. iPump 6400 operations performed via a web browser are described under 3.9 iPump 6400 Operations by Function on page 43.
Once the web browser access is established, you may change your IP address from the browser. See Network Setup on page 42.
Static vs. dynamic setup
The iPump 6400 allows you to configure your IP setup as either static or dynamic. The static setup allows you to set a fixed IP address, whereas a dynamic setup or DHCP (Dynamic
Host Configuration Protocol) selects a temporary IP address from your network. Figure 3.7 and Table 3.2 detail the iPump 6400 Browser Control Setup.
Figure 3.7: iPump 6400 web browser control setup process
24
Table 3.2: iPump 6400 web browser control setup procedure
It may be necessary to set the IP address, subnet mask, and gateway to specific values.
Consult your local network administrator to verify the IP address information.
Note: Write down the iPump 6400's IP address displayed on the screen. Then use the steps listed in Web Browser Access on page 25 to gain control from your browser.
Begin from the HOME screen.
3.
4.
1.
2.
5.
6.
Step Press
# UNIT SETUP
ENTER RECORD AND PLAY
#
#
#
DECODER SETUP
AUDIO SETUP
LAN IP SETTINGS
Displayed
ENTER LAN IP ADDRESSING SELECT: xxxxx
Press Enter to select either STATIC or DHCP for setup.
For more information, see Selectable Fields on page 21.
Screen Type
Menu
Menu
Menu
Menu
Menu
Selectable
800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Step Press
7.
#
8.
9.
10.
#
#
#
Displayed
IP ADDRESS
To change this field, see Editable Data Fields on page 20
SUBNET MASK
To change this field, see Editable Data Fields on page 20
GATEWAY
To change this field, see Editable Data Fields on page 20
SAVE ALL CHANGES? YES<ENTER> NO <ESC>
Press ENTER to save all the changes or press ESC to cancel the changes. The iPump 6400 returns you to the IP SETUP screen.
Screen Type
Editable
Editable
Editable
Selectable
Web Browser
Access
You must include leading zeros in addresses entered from the iPump 6400 front panel, but not when entering them from the browser interface. For example, IP address
128.092.050.004 (as entered from the iPump 6400 front panel) must be entered as
128.92.50.4 in the web browser.
1. Open a current-version internet browser from a computer on the LAN attached to the
iPump 6400.
2. In the browser's address field, enter the IP address noted from the IP Address screen, and then the Status tab of the iPump 6400 web browser appears.
Figure 3.8: iPump 6400 web browser Status tab
IP address with no leading zeros
www.wegener.com
800009-01 Rev. J 25
Operation
3.4 Front Panel Operation
Operate the iPump 6400 from the front panel using the push buttons and the LCD. Menu screens on the LCD direct you to screens that control various operating parameters or display information about the iPump 6400. Menu titles represent either a category of control
(such as Unit Setup, Record and Play, and Transport In Setup) or the name or category of parameters or information to be displayed (such as RF Status, Active Recordings, or
Navigation Help).
LCD Menu
Navigation
Figure 3.9 below illustrates the complete LCD menu structure including user input screens.
User input screens shown below the menus allow control of items such as Program Number
to Record, File to Record to, Decoder Number to Play File to, and others. For more information on use, see User Input Screens on page 20.
Press the...
To...
As shown by the arrows...
right and left arrow buttons
!"#
ESC button
!" move between menu screens on the same level top and bottom arrow buttons
$"%
!" moves up or down a level
ENTER button !" move down to the next level
!" view the information and user-input screens within a particular category
!" move up a level
!" move to the first menu of the current level
!" return the Home screen connecting the left and right sides of the boxes connecting the tops and bottoms of the boxes connecting the tops and bottoms of the boxes
Note: When you reach the last menu of a particular level, pressing the right arrow button again moves you back to the first menu of that level.
Pressing the ESC button repeatedly always returns you to the Home screen.
Figure 3.9: iPump 6400 LCD menu structure
3.5 Front Panel Initial Unit Setup
Some of the iPump 6400’s settings are preconfigured or should be configured during the
iPump 6400's initial setup and are not likely to require adjustment on a regular basis. Setup
26 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual for LNB LO Frequency, LNB DC Power, Date and Time, and Unit Label should be made at this time.
Pre-configured
Transport In
Settings
A few of the Transport In Settings (LNB LO Value, SNR Alarm Threshold, and SNR Margin
Warning) are preconfigured and should only be changed if advised by your satellite operator. Table 3.3 lists these settings as they are originally configured from the factory.
Parameter
LNB LO Value
SNR Alarm
Threshold
SNR Margin
Warning
Table 3.3: iPump 6400 pre-configured Transport In Settings
Application / Description
Default appropriate for Ku-band reception. 5150 MHz would be an appropriate setting for C-band operation.
Signal-to-noise ratios below this value results in an alarm condition.
Preset Value
10750 MHz
5.0 dB
Warning condition triggered when signal-to-noise ratio is within 3.0 dB of the SNR Alarm Threshold (under 8.0 dB as preset).
3.0 dB
Navigation to
Transport In
Setup Screen
Use the front panel navigation buttons to go to the Transport In Setup screen as shown in
Figure 3.10 and Table 3.4. From the Transport In Setup screen, you can set:
!" Transport In Current Channel
!" LNB LO Frequency
!" LNB DC Power
Figure 3.10: LCD menu navigation to Transport In Setup screen
Table 3.4: Menu navigation to Transport In Setup screen
Begin from the HOME screen.
Transport In
Current
Channel
Setup
3.
4.
1.
2.
5.
6.
Step Press
#
ENTER
#
#
#
#
Displayed
UNIT SETUP
RECORD AND PLAY
DECODER SETUP
AUDIO SETUP
IP SETUP
TRANSPORT IN SETUP
Screen Type
Menu
Menu
Menu
Menu
Menu
Menu
Configure the Transport In Current Channel from the Transport In Setup screen.
Figure 3.11 and Table 3.5 detail the procedure for adjusting the Current Channel settings.
www.wegener.com
800009-01 Rev. J 27
Operation
Figure 3.11: Menu navigation to set Transport In Current Channel
LNB Type
Table 3.5: Procedure for adjusting Transport In Current Channel settings
Begin from the Transport In Setup screen. See Navigation to Transport In Setup Screen on page 27.
2.
3.
Step Press
1.
4.
5.
6.
7.
8.
Displayed / Field Details
ENTER TRANSPORT IN STATUS: TRACKING: Eb/No = XX. X
Transport In Status is shown. If the iPump 6400 unit is
Tracking , then the screen also displays Eb/No .
# CURRENT CHANNEL
ENTER DOWNLINK FREQUENCY: XXXXX. XX MHz
Enter the Downlink Frequency from the LNB local oscillator in
MegaHertz.
# TRANSP. DATA RATE: XXX. XX Mbps
Enter Transport Stream Data Rate in Megabits per second.
# RF- MOD / FEC RATIO: QPSK 3 / 4
RF Mod ulation is QPSK . Available F orward E rror C orrection
Ratios are 1/2 , 2/3 , 3/4 , 5/6 , 7/8 , and 8/9 .
# PROGRAM NUMBER: 00001
Enter the Program Number or code of the program to be selected from the transport stream.
# TAG SITE:
Values entered in this field do not affect iPump 6400 operation.
# SAVE ALL CHANGES?
YES <ENTER> NO <ESC>
Press ENTER to save all the Transport In Setup changes or press ESC to cancel the changes. The iPump 6400 returns you to the Current Channel screen.
Screen
Type
Data
Display
Menu
Editable
Editable
Selectable
Editable
<Unused>
Selectable
Available LNB Types are Multiswitch, Universal/Astra, and Local Oscillator. Select the
LNB Type from the Transport In Setup screen. Figure 3.12 and Table 3.6 detail the procedure for selecting the LNB Type.
Note: LNB Setup may also be performed from the web browser. See LNB Setup on page 40.
28 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Note: For proper multiswitch operation, LNB DC Power must be set to ON.
Figure 3.12: Menu navigation to set LNB type
Table 3.6: Procedure for setting LNB LO Frequencys
Begin from the Transport In Setup screen. See Navigation to Transport In Setup Screen on page 27.
2.
3.
1.
Step Press Displayed/Field Details
ENTER TRANSPORT IN STATUS: TRACKING: Eb/No =
XX.X
Transport In Status is shown. If the iPump 6400 unit is
Tracking , then the screen also displays Eb/No .
#
#
CURRENT CHANNEL
LNB LO FREQUENCY
Screen Type
Data Display
Menu
Selectable
LNB DC
Power Setting
For proper multiswitch operation, LNB DC Power must be set to ON .
Set the LNB DC Power from the Transport In Setup screen. Figure 3.13 and Table 3.7 detail the procedure for setting the
LNB DC Power.
Figure 3.13: Menu navigation to set LNB DC power
www.wegener.com
Table 3.7: Procedure for setting LNB DC power
Begin from the Transport In Setup screen. See Navigation to Transport In Setup Screen on page 27.
2.
3.
4.
1.
Step Press Displayed / Field Details
ENTER TRANSPORT IN STATUS: TRACKING: Eb/No = XX.X
Transport In Status is shown. If the iPump 6400 unit is
Tracking , then the screen also displays Eb/No .
#
#
#
CURRENT CHANNEL
LNB LO FREQUENCY
LNB DC POWER
Screen Type
Data Display
Menu
Menu
Selectable
800009-01 Rev. J 29
Operation
3.6 Front Panel Additional Unit Setup
Some of the iPump 6400 front panel settings are important, but not essential to the unit’s initial setup including:
!"
Date/Time Setup
!"
Unit Label Setup
!"
HTTP Proxy settings
!"
Return Path Setup
Navigation to
Date/Time
Setup Screen
Set up the date and time for the iPump 6400 during the initial setup. Use the front panel navigation buttons to go to the Date/Time screen as shown in Figure 3.14.
Figure 3.14: LCD Menu navigation to Date/Time Setup screen
Date/Time
Setup
When operating under the Compel network, date and time settings are overwritten by
Compel. However, Time zone and Daylight Savings Time settings remain under local control and should be set by the user.
From the Date/Time screen, you can set or adjust the:
!" current date
!" current time
!" offset from GMT (Greenwich Mean Time)
!"
DST (Daylight Savings Time) observance
Note: Date/Time Setup may also be performed from the web browser. See Date / Time
Setup on page 41.
Table 3.8 on page 30 details the procedure for adjusting the Date/Time settings.
Table 3.8: Procedure for setting Date/Time parameters
Begin from the Date/Time Setup screen.To change the screens, see Editable Data Fields on page 20 and Selectable Fields on page 21.
Step
1.
2.
Press Displayed/Field Details
ENTER CURRENT DATE
YYYY / MM / DD
Enter Current Date in year/month/day format.
# CURRENT TIME
HH: MM: SS
Enter Current Time in hours:minutes:seconds format.
Screen Type
Editable
Editable
30 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Step
3.
4.
Press
#
#
Displayed/Field Details
OFFSET FROM GMT
GMT - 5 EST / EDT
Select the appropriate offset from G reenwich M ean T ime.
Offset selections range from GMT -12 to GMT +11 . (U.S.
E astern S td. T ime is at GMT -5 ; U.S. P acific S td. T ime is at
GMT -8 .)
DAYLIGHT SAVING TIME
OBSERVED? YES
Select Yes if Daylight Saving Time is observed in your area or No if it is not.
Screen Type
Selectable
Selectable
Navigation to
Unit Label
Setup Screen
Assign a name to the iPump 6400 during the initial setup. Use the front panel navigation buttons to go to the Unit Label screen as shown in Figure 3.15.
Figure 3.15: LCD menu navigation to Set Unit Label screen
Unit Label
Setup
Set the Unit Label, the name assigned to the iPump 6400, during the initial setup. Table 3.9 details the label-entering procedure.
Note: Refer to User Input Screens on page 20 for information on updating the editable and selectable screens.
Table 3.9: Procedure for entering iPump 6400 Unit Label
Begin from the SET UNIT LABEL screen. To change the screens, see Editable Data Fields on page 20 and Selectable Fields on page 21.
Step
1.
2.
Press Displayed/Field Details
ENTER U. LABEL A B C D E F G H I
J K L M N O P Q R
Note: Additional characters including numerals, decimal, space, and hyphen appear as you move downward through the available characters.
Select additional characters until the Unit Label is displayed completely at the bottom left of the LCD.
ESC DONE? <YES> <NO - ESC>
_________________
Press ENTER to confirm the unit label or ESC to return to the UNIT LABEL screen.
Screen Type
Editable
Selectable
www.wegener.com
800009-01 Rev. J 31
Operation
Navigation to
HTTP Proxy screens
Contact your local network administrator for the correct settings. Set the address for the
HTTP Proxy IP and HTTP Proxy Port. Use the front panel navigation buttons to go to the
HTTP Proxy screens as shown in Figure 3.16.
Figure 3.16: LCD menu navigation to HTTP Proxy screens
HTTP Proxy IP and Port
Setup
Table 3.10: Procedure for adjusting HTTP Proxy settings
Begin from the HTTP Proxy Setup screen.
Step Press
1.
2.
3.
4.
Displayed / Field Details
Screen
Type
Selectable ENTER HTTP PROXY ENABLE
Select to enable or disable HTTP Proxy.
# HTTP PROXY IP
000.000.000.000
Select numbers until the Proxy IP address is complete.
# HTTP PROXY PORT
00000
Select numbers until the Proxy Port Number is complete.
# SAVE ALL CHANGES?
YES <ENTER> NO <ESC>
Press ENTER to save all the HTTP Proxy Setup changes or press ESC to cancel the changes. The iPump 6400 returns you to the HTTP Proxy Setup screen.
Editable
Editable
Selectable
Navigation to
Return Path screen
The Return Path is the communications return channel used for delivering status and reporting information to the network control system. If your local network uses a proxy server, you may need to set the IP addresses for the Return Path main server and the backup server. Use the front panel navigation buttons to go to the Return Path screen as shown in Figure 3.17.
32 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Figure 3.17: LCD menu navigation to Return Path screen
Return Path
Setup
Begin from the Return Path screen.To change the screens, see Editable Data Fields on page 20.
Step
1.
2.
3.
Press Displayed/Field Details
ENTER RETURN PATH SETUP
PRESS<ENTER>
ENTER MAIN SERVER IP
000.000.00.000
Select numbers using a valid IP address provided by your Network Control Administrator. Entering the wrong IP address here prohibits status information from being delivered to the network control system.
# Bkup SERVER IP
000.000.00.000
Select numbers until the Backup Server IP address is complete.
Screen Type
Menu
Editable
Editable
3.7 Optional Front Panel Screens
Your iPump 6400 may be configured for optional features including:
!"
Modem
!"
Genlock
!"
SMB access control
Navigation to
Modem Setup
Screen
Use the Modem setup for configuring dial-up settings in conjunction with an Internet service provider or a corporate e-mail server.
In addition to front panel operation, access this feature using your web browser. See
Modem Setup on page 42.
Use the front panel navigation buttons to go to the Modem screen as shown in Figure 3.18.
www.wegener.com
800009-01 Rev. J 33
Operation
Figure 3.18: LCD menu navigation to Modem screen
Modem Setup
Begin from the Modem Setup screen.To change the screens, see Editable Data Fields on page 20 and Selectable Fields on page 21.
Step
1.
2.
3.
4.
5.
6.
7.
8.
Press Displayed/Field Details
ENTER PHONE NUMBER
PRESS<ENTER>
ENTER PHONE NUMBER xxx-xxx-xxxx
Select numbers until the phone number used by the modem is complete.
$# DIAL OUT PREFIX <ENTER>
The prefix code disables any phone features such as call waiting. Press ENTER and select numbers or characters until the prefix code for the phone number is complete.
ESC
#
DONE? <YES> <NO - ESC>
_________________
Press ENTER to confirm the phone number or ESC to return to the DIAL OUT PREFIX screen.
PPP USERNAME <ENTER>
Press ENTER and select characters until the username is complete.
ESC
#
ESC
DONE? <YES> <NO - ESC>
_________________
Press ENTER to confirm the username or ESC to return to the PPP USERNAME screen.
PPP PASSWORD <ENTER>
Press ENTER and select characters until the password is complete.
DONE? <YES> <NO - ESC>
_________________
Press ENTER to confirm the username or ESC to return to the PPP USERNAME screen.
Screen Type
Menu
Editable
Editable
Selectable
Editable
Selectable
Editable
Selectable
34 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Navigation to
Genlock
Setup Screen
Use the Genlock setup if you have a professional video decoder installed in your iPump
6400. You have the option to enable or disable synchronization of the video output signal to an external timing source commonly referred to as Genlock.
In addition to front panel operation, this feature can also be accessed via your web browser, see Genlock Setup on page 38.
Use the front panel navigation buttons to go to the Genlock screen as shown in Figure 3.19.
Figure 3.19: LCD menu navigation to Genlock screen
Genlock
Setup
Begin from the Genlock Setup screen. For more information on the settings, see the table on page 38.
Step
1.
2.
3.
Press Displayed/Field Details
ENTER GENLOCK SETTINGS
SELECT: <DISABLE> <ENABLE>
# HORIZ. TIME DELAY
SELECT:
Adjusts horizontal delay for (genlocked) video timing.
# SUBCARRIER PHASE
SELECT:
Adjusts composite (genlocked) video subcarrier phase
Screen Type
Selectable
Selectable
Selectable
Navigation to
SMB Screen
The Server Message Block Protocol (SMB protocol) provides a method for a user to access files remotely through Microsoft Windows. Use the SMB screen to designate access for the
iPump 6400 to Microsoft Windows.
Use the front panel navigation buttons to go to the SMB screen as shown in Figure 3.20.
Figure 3.20: LCD menu navigation to SMB screen
www.wegener.com
800009-01 Rev. J 35
Operation
SMB Screen
Setup
Begin from the SMB Setup screen.
Step
1.
Press Displayed/Field Details
ENTER SMB SETTINGS
SELECT: <READ ONLY> <FULL ACCESS> <OFF>
SMB Setting
Read Only
Full Access
Off
Description
Allows users read-only permissions
Default setting that allows users full read/write permissions
Stops SMB service
Screen Type
Selectable
Screen Park
Setup
After a period of inactivity, the iPump 6400 front panel display returns to the home screen.
The Screen Park feature allows you to "park" the LCD screen to any front panel display. An example of this feature’s use is to park the LCD screen on the current time display so that the time is in view until the front panel is used for another function.
To enable Screen Park:
1. Navigate to the desired front panel screen.
2. Press and hold the down arrow push button and then also press the ENTER push button.
The LCD screen displays: Screen PARK is ENABLED. down arrow push button
ENTER push button
To disable Screen Park:
1. Press any key. The LCD screen displays: Screen PARK is DISABLED.
Note: A system shutdown or reboot automatically disables the screen park feature.
3.8 Web Browser Initial Setup
The web browser attached to the iPump 6400 via an Ethernet allows you to perform most
iPump 6400 functions. This section provides an overview on the setup configurations available from the web browser. To view specific operations available through the web browser, see 3.9 iPump 6400 Operations by Function on page 43.
The iPump settings can only be changed if local control is enabled by your Compel Network administrator.
Access the
Setup Tab
1. Enter the iPump 6400's IP address in the address bar of the web browser.
2. Click the Setup tab. The browser displays the Setup tab drop-down menu.
36 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Figure 3.21: iPump 6400 web browser Setup tab
Decoder
Setup
If your iPump 6400 has the optional second decoder, then your system can simultaneously play two live programs from the same DVB carrier.
Decoder
#1
#2
#3
Operation
The primary decoder, allows your system to play a single live program from the DVB carrier.
The optional second decoder, allows your system to simultaneously play two live programs from the same DVB carrier.
The optional third decoder, allows your system to stream content to an external SMD 515 device.
Note: Each grouping of parameters are setup independently. Selecting Activate or Cancel returns you to the previous screen.
1. From the Setup tab, select Decoder(#) from the Setup tab’s drop-down menu.
2. Click the Edit button under Settings for Decoder(#) to change that group of parameters.
3. Update the parameters by changing the text in the text boxes or selecting a different option from the drop-down boxes.
www.wegener.com
800009-01 Rev. J 37
Operation
Genlock
Setup
4. To save your changes, click the Activate button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Activate or Cancel returns you to the previous screen.
If you have a professional video decoder installed in your iPump 6400, you have the option to enable or disable synchronization of the video output signal to an external timing source commonly referred to as Genlock.
The iPump 6400’s genlock feature allows you to:
!" view the genlock state
!" activate or disable genlock
!" set the Horizontal Time Delay
!" select the Subcarrier Phase
To set this feature up from the front panel, see Genlock Setup on page 35.
1. From the Setup tab, select Decoder from the Setup tab’s drop-down menu.
2. Click the Edit button under either Genlock Settings For Decoder #1 or Genlock Settings
For Decoder #2 (optional) to change the settings.
3. Update the settings by selecting the available options from the drop-down boxes. The descriptions are in the table below.
38
Setting
Genlock
Horizontal Time
Delay
Subcarrier Phase
Enable
Disable
Option
Limits are +2 to -2
(1-pixel steps)
Limits are +180 to -180 in 1.4-degree increments
Action requests genlock activation genlock is inactive and the video output synchs to the decoder's internal clock adjusts horizontal delay for (genlocked) video timing adjusts composite (genlocked) video subcarrier phase
4. To save your changes, click the Activate button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Activate or Cancel returns you to the previous screen.
800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
User State vs. Current State
As the user, you control the status of the user state
by enabling or disabling the iPump 6400 genlock. To assist in troubleshooting, the iPump 6400 also displays the genlock’s current state
. If genlock is enabled and the external genlock timing source is interrupted, genlock is automatically disabled and the iPump 6400 displays a 'No Genlock Sync' alarm on the front panel. This indicates the video output is no longer synchronized with the external genlock source.
Note: To clear the 'No Genlock Sync' alarm, either restore the external genlock timing source and re-enable genlock, or disable genlock to continue synchronizing the video output to the decoder's internal clock.
Click Disable to suspend genlock
Satellite
Receive Setup
1. From the Setup tab, select Transport Input from the Setup tab’s drop-down menu.
2. Click the Edit button under Transport Input Settings to change that group of parameters.
3. Update the parameters by changing the text in the text boxes or selecting a different option from the drop-down boxes.
IP Setup
4. To save your changes, click the Update button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Update or Cancel returns you to the previous screen.
Note: The Program field is used whenever Follow Tune is selected in the Settings for
Decoder (#). A program number of zero (0) indicates the first available program found in the input stream.
For the iPump 6400 to play satellite multicast streams, the IP settings must contain the correct PIDs (Packet IDs).The iPump 6400 extracts the MPE (Multi Protocol Encapsulated)
IP data from the input transport stream.
1. From the Setup tab, select Transport Input from the Setup tab’s drop-down menu.
2. Click the Edit button under IP Settings to change that group of parameters.
www.wegener.com
800009-01 Rev. J 39
Operation
3. Update the parameters by changing the text in the text boxes.
LNB Setup
4. To save your changes, click the Activate button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Activate or Cancel returns you to the previous screen.
For compatibility between your satellite dish and the iPump 6400, select the LNB (Low
Noise Band) converter to match the one installed on your satellite dish.
1. From the Setup tab, select Transport Input from the Setup tab’s drop-down menu.
2. Click the Edit button under LNB Settings.
3. Select the LNB type from the drop-down menu.
list of LNB types
Note: Your selection of LNB type determines the available fields to update.
fields for local oscillator fields for multiswitch fields for universal/astra
40
4. Update the parameters by changing the text in the text boxes or selecting options from the drop-down boxes.
800009-01 Rev. J www.wegener.com
SNR Alarm
Warnings
Setup
iPump 6400 User’s Manual
5. To save your changes, click the Activate button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Activate or Cancel returns you to the previous screen.
Set the iPump 6400 to configure "trip points" at which Alarm or Warning indications are triggered when the RF signal yields low or marginal Eb/No readings.
1. From the Setup tab, select Transport Input from the Setup tab’s drop-down menu.
2. Click the Edit button under SNR Alarm Warnings to change that group of parameters.Update the parameters by selecting options from the drop-down boxes.
Date / Time
Setup
Parameter Value Range
SNR Alarm Threshold
SNR Margin Warning
EbNo alarm threshold in dB Trip points range from 2dB to 11dB
Eb/No margin warning zone in dB Margin values range from
1dB to 10dB
Note: The sum of the selected Alarm Threshold and Margin Warning values cannot exceed 12dB
3. To save your changes, click the Activate button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Activate or Cancel returns you to the previous screen.
When operating under the Compel network, date and time settings are overwritten by
Compel. Time zone and DST (Daylight Savings Time) settings, however, remain under local control and should be set by the user.
1. From the Setup tab, select System from the Setup tab’s drop-down menu.
2. Click the Edit button under Time Settings to change that group of parameters.
3. Update the date and time by changing the text in the text boxes. To designate the time zone, select the number of hours it is from Greenwich Mean Time. Select Yes if the time zone observes DST or No if the time zone does not observe DST.
www.wegener.com
800009-01 Rev. J 41
Operation
4. To save your changes, click the Activate button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Activate or Cancel returns you to the previous screen.
Note: Date/Time Setup may also be performed from the front panel . See Navigation to
Date/Time Setup Screen on page 30.
Modem Setup
Use the /Modem setup for configuring dial-up settings in conjunction with an Internet service provider or a corporate e-mail server. During entry the password is visible and then hidden after entry for security reasons. To set this feature up from the front panel, see Navigation
to Modem Setup Screen on page 33.
1. From the Setup tab, select ReturnPath from the Setup tab’s drop-down menu.,
2. Click the Edit button under Modem Settings to change that group of parameters.
3. Update the parameters by changing the text in the text boxes.
Network
Setup
4. To save your changes, click the Update button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Updateor Cancel returns you to the previous screen.
To change your network settings, be sure to enter a valid IP address from your network. The web browser attempts to re-connect to the iPump 6400 using the new network settings.
Entering the wrong network settings could leave you disconnected from the iPump 6400. If disconnected, correct the network settings using the front panel. See Web Browser
Operations Startup on page 24.
1. From the Setup tab, select Network from the Setup tab’s drop-down menu.
2. Click the Edit button under Network Setup to change that group of parameters.
3. Update the parameters by changing the text in the text boxes or selecting a different option from the drop-down boxes.
42
4. To save your changes, click the Update button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Updateor Cancel returns you to the previous screen.
800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Return Path
Setup
The Return Path is the communications return channel used for delivering status and reporting information to the network control system. When setting or changing the Return
Path Server IP address, be sure to enter a valid IP address corresponding to the address given to you by your Network Control Administrator. Entering the wrong IP address here prohibits status information from being delivered to the network control system.
1. From the Setup tab, select ReturnPath from the Setup tab’s drop-down menu.
2. Click the Edit button under Return Path Settings to change that group of parameters.
3. Update the parameters by changing the text in the text boxes.
iPump 615
Setup
4. To save your changes, click the Update button. Any changes take effect immediately. To discard any changes, click the Cancel button. Selecting Updateor Cancel returns you to the previous screen.
The iPump 615 is a peripheral decoder device capable of decoding MPEG2 Program
Streams delivered across a LAN (Local Area Network). Use the iPump 615 Settings to have the iPump 615 decode a stream.
1. From the Setup tab, enter the iPump 615 IP Address, Stream Address and Stream Port settings in the text boxes.
2. To send a one-time command to the iPump 615, click the Submit button.
3.9 iPump 6400 Operations by Function
Most iPump 6400 functions can be performed either locally from the front panel or from a web browser attached to the iPump 6400 via an Ethernet. Web browser operation is described in this section because after the initial configuration, most users use the web browser rather than the front panel. Operations are listed and described by function.
Monitor iPump 6400
Status
Monitor iPump 6400 status as follows:
1. Enter the iPump 6400's IP address in the address bar of the web browser.
2. The iPump 6400 Status tab automatically displays.
3. Click the Show Parameters button for additional system parameters or click the Clear
Diagnostics button to clear the Signal Quality diagnostic counts.
www.wegener.com
800009-01 Rev. J 43
Operation
The unit’s Serial Number, Current Software Version, and Model Number are shown.
Receiver Mode, Signal-to-noise Ratio, Decoder States and Settings, Packet Counts, and
Record activities are also displayed and refreshed every few seconds.
Figure 3.22: iPump 6400 web browser Status tab
Monitor Alarm and Warnings
The iPump 6400 allows you to view current alarm and warning indications, and remove certain alarm and warning indications after they are acknowledged.
Monitor and clear iPump 6400 alarm and warning indications as follows:
1. From the Status tab, click the View Alarms/Warnings button.
2. The iPump 6400 displays the Current Alarms/Warnings lists. Click the Alarms or
Warnings arrows to view the alarm and warning indications.
Live Program
Play
3. Click the Clear indications button to remove all acknowledged alarms and warnings. The
iPump 6400 displays a pop-up alert noting that all acknowledged alarms and warnings are cleared. To return to the Status tab, click OK.
When set up for live program play, the iPump 6400 decodes an incoming MPEG stream from the received DVB satellite signal and decrypts and decodes the audio and/or video from the selected program to the connected audio and video monitors. Two live programs from the same DVB carrier may be played simultaneously if your iPump 6400 has the optional second decoder.
Checklist for Live Program Play
Before starting live program play, ensure that these settings are appropriate and active:
44 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
!"
RF input and audio and/or video output connections are set. The CARRIER light should be a constant green. See page 22.
iPump 6400 front panel LED indicator descriptions on
!"
Transport In Settings are selected. Verify that Downlink Frequency , Transport Data
Rate , FEC Ratio , and Program Number have been properly selected before playing a live program. See Procedure for adjusting Transport In Current Channel settings on page 28.
!" Satellite Receive Settings options selected from the web browser. See Satellite
Receive Setup on page 39.
Procedure for Live Program Play
If your iPump 6400 has additional decoders, repeat the steps below using the Edit button for
Decoder 2 or Decoder 3.
Note: Each grouping of parameters are setup independently. Selecting Activate or Cancel returns you to the previous screen.. Any activated changes take effect immediately.
1. From the Setup tab, select Decoder 1 and then click the Edit button under Settings for
Decoder #1.
www.wegener.com
2. From the Setting list, select a DVB program. The descriptions are in the table below.
Table 3.11: DVB programs
Setting Function
Off
Follow Tune
Stops live program playing
Plays whatever DVB program is selected under Satellite Receive Setting
SAT IP Multicast Plays the first audio content if more than one is detected in the satellite stream.
If selected, also set the UDP Port and Multicast Address. To play satellite multicast streams, the IP settings must be set, see IP Setup on page 39.
LAN IP Unicast Plays the first audio content if more than one is detected in the LAN stream.
If selected, also set the UDP Port.
800009-01 Rev. J 45
Operation
Record
Program to
File
Setting Function
LAN IP Multicast Plays the first audio content if more than one is detected in the LAN stream.
If selected, also set the UDP Port and Multicast Address.
Program Plays user recorded programs. See Record Program to File on page 46.
3. To save your changes, click the Activate button.To discard any changes, click the Cancel button.
4. Next, set the Mute options. Select Mute or UnMute from the drop-down boxes for Video,
Audio Left, and Audio Right.
5. To save your changes, click the Activate button.To discard any changes, click the Cancel button.
6. Next, set the Audio Setting options. Update the parameters by changing the numbers in the
Analog Attenuation (dB) and Boost Headroom (dB) text boxes or selecting a different option from the Routing drop-down box.
7. To save your changes, click the Activate button.To discard any changes, click the Cancel button.
8. If your iPump 6400 has the optional decoders, repeat the steps above using the Edit button for Decoder 2 or Decoder 3.
The iPump 6400 can record incoming programs to stored files for later playback. Up to three separate programs may be recorded at one time.
Note: Record and Play settings are volatile through power cycles. Except for the Loop
Forever playlist setting, these settings are lost when the iPump 6400 is restarted. If
Loop Forever is selected, then the playlist chosen to loop forever begins playing when the iPump 6400 returns to service after a reboot.
Procedure for Recording a Program to File
1.
Check that RF input and audio and/or video output connections are set. The CARRIER light should be a constant green. See iPump 6400 front panel LED indicator descriptions on page 22.
2. Click the Rec/Play tab from the web browser.
46 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Figure 3.23: iPump 6400 web browser Rec/Play tab
Record/Play chart File Playback Record
www.wegener.com
3. Under Record, in the Filename: box, enter a name for the file you wish to record. File names are limited to 16 characters. Upper and lower case letters, numerals, decimals and spaces are allowed, but leading or following spaces are truncated. The file name may not begin or end with a space or spaces.
Note: Users should avoid accidentally overwriting an existing file. The iPump 6400 front panel displays a warning message before the Record function overwrites an existing file with the same name, but does not prevent the overwriting.
Next enter a time in the Length of Recording boxes. Enter the duration of time to record in hours, minutes, seconds, and tenths of a second. Enter a duration slightly longer than the expected program length to ensure that you record the entire program. To record for an indefinite period, select the Continuous Record checkbox. The iPump 6400 continues to record until commanded to stop, or until the available disk space is consumed.
Note: If the storage capacity is filled over 99% during recording, the iPump 6400 begins deleting existing files in chronological order beginning with the oldest file. The current recording is not interrupted unless all deletable files have been deleted and remaining storage capacity remains under 1%.
4. Under Record, select the type of program.
If the program is...
Then select...
Classical MPEG Single Audio or All Audio’s and select a program from the dropdown list
MPEG Under IP an IP Program and enter the IP Multicast Address and UDP
Port Number corresponding to the desired stream.
For more information on DVB programs, see Table 3.11 on page 45.
5. Click the Record button to begin recording the selected program.
800009-01 Rev. J 47
Operation
6. To stop recording before the end of the entered length of recording, click the Click to Stop hyperlink for the appropriate file on the Record/Play chart.
Active recording & directory
Time remaining
Click to Stop hyperlink
Play
Recorded
Program File
Use the File Playback box to play a recorded file or a playlist. For more on playlists and creating them, see About Playlists on page 53 and Playlist Procedures on page 54.
Use the following steps to play a recorded or previously downloaded program file:
1. Click the Rec/Play tab on the web browser.
2. Under File Playback, select either a playlist from the Play a Playlist list or a file from the
Play a file list.
3. If selecting a playlist, you may also select one of the option buttons for looping styles:
Looping style Function
Loop on Last repeats the last file until stopped by the user
Loop Forever repeats the entire playlist until stopped by user
Loop N Times repeats the entire playlist "N" times for the number of times entered in the Loop N Times box
Note: Immediate style playlists support looping styles while timed playlists ignore them.
For more information see, Looping Styles on page 54.
4. If selecting a file, click the filename under the Play a file list. To navigate the list:
!"
The file size in bytes is shown in parentheses adjacent to each filename.
!"
The name of the current directory is shown just above the list of files.
!"
To view file names in the next higher directory, double click [-Previous Directory-] if available.
48 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
!"
To view file names in the next lower directory, double click any selection displayed in red text inside square brackets (such as [directoryname] ).
Current directory
Higher directory
List of files
5. Click one of the Play to Decoder (#) buttons to immediately begin playing the file or playlist through the desired decoder. The Record/Play chart on the left displays the name and time remaining of the selected file or playlist.
Note: The Play to Decoder 2 option is for dual-decoder iPump 6400s. The Play to Decoder
3 option is for iPump 6400s with an external decoder for the SMD 515 connected to your LAN.
6. To stop playing a file or playlist before it has finished, click the Click to Stop hyperlink under the Record/Play chart.
Active playlist or file
Time remaining
File
Management
Click to Stop hyperlink
Use the following steps to view, delete, or rename files.
1. Click the Files tab from the web browser.
www.wegener.com
800009-01 Rev. J 49
Operation
Figure 3.24: iPump 6400 web browser Files tab
2. To select a file, click the filename under the File Manager list. To navigate the list:
!" The file size in bytes is shown in parentheses adjacent to each filename.
!" The name of the current directory is shown just above the list of files.
!"
To view file names in the next higher directory, double click [-Previous Directory-] if available.
!"
To view file names in the next lower directory, double click any selection displayed in red text inside square brackets (such as [directoryname] ).
Lower directory
Current directory
List of files
50
3. To view a file, select the file and click the View File button or double-click the filename to open/play the file on your screen. The file is opened by the application indicated by the file extension (For example, Windows Media Player for .mpg files, Microsoft Word for
.doc files).
4. To delete a file, select the file and click the Delete File button.
5. To rename the file, select the file, and type the new name in the Rename File box. After completing the new filename, click the Rename File button.
Note: File names can include upper and lower case letters, numerals, decimals, and spaces.
Leading or following spaces are truncated, so the file name may not begin or end with a space or spaces.
800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
File Streaming and Routing
For multicast streaming you can select to stream from existing files or a live classical DVB program.
1. Click the Streams tab on the web browser.
Figure 3.25: iPump 6400 web browser Streams tab
Stream Status Streaming Files Stream Live Program
Scheduled
Operation
Click To Stop hyperlinks
2. If streaming from an existing file, select a file from the Streaming Files list. The name of the current directory is shown just above the list of files. When displayed, you may double click [-Previous Directory-] to view file names in the next higher directory. Or, double click any selection displayed in red text inside square brackets (such as [directoryname]) to move down to that directory level.
3. If streaming live from a "classical" DVB program, select the program to stream from the
Program/Language pull-down list under Stream Live Program.
4. Click inside the Multicast Destination: box and type the appropriate IP address. Also enter the UDP Port number in the UDP Port: box.
5. When the address information and selected file or stream information are correct, click the
Start File Stream: or Start Live Stream: button respectively to begin streaming.
6. To stop file streaming, click the Click to Stop hyperlink in the Stream/Status box.
From the web browser, you can view schedules of Record and Play operations set up by the
Compel network for the iPump 6400 by clicking the Schedule tab
If needed, click Disable to temporarily suspend scheduled operations. Click Enable to return to scheduled operations. The iPump 6400 resumes performing operations according to the scheduled times. Operations scheduled for times during which the unit is "disabled" are not performed.
www.wegener.com
800009-01 Rev. J 51
Operation
Figure 3.26: iPump 6400 web browser Schedule tab
Playlist
Management
With iPump 6400 playlists, you can set up and play a stored sequence of items without interruption. Playlists are stored in nonvolatile memory so that they remain available after the unit restarts. In the context of the iPump 6400 playlists, an item is a single media file. A playlist consists of one or more items that are played from beginning to end in sequential order.
The iPump 6400 can store up to 2,000 playlists with each playlist containing up to 2,000 items. Available items to add to a playlist are found in the Asset List.
Note: "Loss of service" occurs when the RF signal drops below a minimum threshold or the feed is lost entirely. Loss of service does not affect a currently playing item or playlist, but does interrupt the play of a live program or multicast stream. When loss of service happens, the iPump 6400 plays a user-defined playlist named LOS until service returns for the live program or multicast stream.
52 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
From the Playlist tab on the web browser, you can:
!" open, create, save, or delete playlists
!" edit playlists by adding, deleting, or moving items from the Asset List
!" customize playlists with a description, alias, on-screen graphic, and/or start time
To view the Playlist Builder, click the Playlist tab on the web browser.
Figure 3.27: iPump 6400 web browser Playlist tab menu bar playlist bar
OSG bar playlist navigation tools
Insert button
Asset List and
Asset Filter active playlist
www.wegener.com
About Playlists
Accessed from the Playlist tab on the web browser, the Playlist Builder allows you to create either timed or immediate playlists with any available items from the Asset List.
Playlist styles
The iPump 6400 supports two styles of playlists:
!" timed
!" immediate
Timed playlists have a specific start time (for example, 1:00 am). As a permanent source for the iPump 6400, a timed playlist resumes playing after a power outage. See Setting a start
time for a playlist on page 59.
Immediate playlist’s items do not have set times and are considered a temporary source since they do not resume play after a power outage except when the playlist’s looping style is Loop Forever. When a playlist’s looping style is Loop Forever, the iPump 6400 recognizes the playlist as a permanent source and begins playing from the beginning of the playlist when the iPump 6400 restarts.
800009-01 Rev. J 53
Operation
Playlist
Procedures
Looping Styles
A looping style determines how an immediate playlist repeats itself or specific items. A timed playlist ignores looping styles. To set a looping style, see Play Recorded Program File on page 48.
Immediate playlists support one of these looping styles:
Looping style Function
Loop on Last repeats the last item in the playlist until stopped by the user
Loop Forever repeats the entire playlist until stopped by user
Loop N Times repeats the entire playlist "N" times for the number of times entered in the Loop N Times box
Random and sequential tags
The Asset Filter allows you to view the Asset List by all items in the directory, or list directories by the Random or Sequential tags.
When you add an item using the Random tag to your playlist, the iPump 6400 arbitrarily selects an item to play from the selected directory. The item selection is not completely random since the iPump 6400 will not select the last played randomly selected item.
When you add an item using the Sequential tag to your playlist, the iPump 6400 plays the items in order from first to last and then looping back around to the first item in the directory for each pass of the item in the playlist.
Note: In a Loop on Last playlist, when the last item has either a Random or Sequential tag, then the last item follows the normal Random or Sequential pattern.
Note: When the playlist contains random or sequential items, the Total Time listing on the playlist bar is inaccurate and is followed by two asterisks.
Procedures for opening, creating, saving, and deleting playlists
All of the following procedures begin from the Playlist tab on the web browser.
Opening a playlist
1. On the menu bar, click the Open list. The Playlist Builder lists the available playlists
2. Select an available playlist. The Playlist Builder opens the playlist and displays it in the active playlist.
Note: If no available playlists exist, then you must create one.
Creating a playlist
1. On the menu bar, click New. The browser opens a text box for the playlist name.
2. Enter the playlist’s name in the text box and click OK. The Playlist Builder displays the playlist name in the playlist bar.
Note: Now you can Save, Delete, or Edit a playlist.
54 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Saving a playlist
To save or duplicate an open playlist:
To...
save the playlist duplicate the playlist
On the menu bar, click,
Save
Save As
The Playlist Builder... saves the playlist. The browser displays:
Saved playlist [name] successfully...returning to editor
1.opens a text box for the playlist name.
2.Enter the playlist’s name in the text box and click OK. The browser displays:
Saved playlist [name] successfully...returning to editor
Deleting a playlist
To delete an open playlist:
1. On the menu bar, click Delete. The browser opens a question box asking:
Are you sure you want to delete the current playlist (name)?.
2. Click OK to delete the playlist. The browser displays:
Successfully DELETED playlist "name" above the playlist bar.
or
Click Cancel, to stop the playlist deletion and return to the Playlist Builder.
Procedures for editing playlists
All of the following procedures begin from the Playlist tab on the web browser.
Navigating the Asset List
1. From the Asset Filter, select either All, Random, or
Sequential. See Random and sequential tags on page 54.
2. Use the scroll bar to view all of the available items.
Adding items to a playlist
To add items to an open playlist:
1. Select a single item or multiple items using Ctrl-click to select nonadjacent items or Shift-click to select adjacent items.
2. Click the Insert button.The Playlist Builder moves the selected items to the active playlist.
www.wegener.com
800009-01 Rev. J 55
Operation
Note: When adding additional items to an established playlist, the Playlist Builder inserts the new items above the selected line (indicated in blue) in the active playlist. To add items to the end of a playlist, select the <<END>> line.
56 selected item in the active playlist
Insert button selected items highlighted in the Asset List
Deleting items from a playlist
Only one item at a time can be deleted from the active playlist. To delete an item from an open playlist:
1. Select an item from the active playlist.
2. Click the Delete button located below the active playlist. The Playlist Builder removes the item from the playlist.
Moving items in a playlist
Items in a playlist are played in the order that they appear in the playlist.To move an item in an open playlist:
1. Select an item from the active playlist.
2. Click either the Up or Down buttons located below the active playlist. The Playlist Builder moves the item accordingly within the playlist.
Note: Only one item at a time can be moved within the active playlist.
Navigating large playlists
When a playlist contains more than 100 items, the current playlist window only displays 100 items at a time. Use the playlist navigation tools to view the other items in the playlist.
Playlist pages
Each page in a playlist consists of 100 items and the scroll bar on the right side allows you to scroll and view the items on each playlist page. If there are any changes to a playlist’s items such as Up, Down, or Delete, then the playlist window adjusts the playlist page.
Example: If the current playlist page displays items 201-300 and you delete item 220, then the open playlist page adjusts to display items 171-270. Clicking the Next Page button, resets the window and displays items 301-400. See Figure 3.28 and
Table 3.28 on page 57.
800009-01 Rev. J www.wegener.com
playlist navigation tools iPump 6400 User’s Manual
Figure 3.28: Large Playlist Navigation tools
Table 3.12: Large Playlist Navigation
To...
Then...
go to a specific item enter the item’s number in the jump box and click
Go move the selected item up in the playlist click Up move the selected item down in the playlist click Down go to the beginning of the playlist click First Page go to the end of the playlist click Last Page go to the next page of the playlist click Next Page go to the previous page of the playlist click Previous Page go to a specific page of the playlist click the drop-down arrow and then select the playlist page
Procedures for customizing playlists
All of the following procedures begin from the Playlist tab on the web browser.
Editing the Description
The playlist description allows you to enter more information about the playlist so that it is easily identifiable. To edit the description in an open playlist:
1. From the menu bar, click Edit Description. The Playlist Builder opens the Description box for editing.
www.wegener.com
2. Enter the playlist’s description and then click Save. The Playlist Builder lists the new description in the playlist bar.
Creating and deleting Aliases
Using a playlist alias allows you to easily recognize the playlist and allows the iPump 6400 to perform the playlist functionality transparently.
800009-01 Rev. J 57
Operation
Note: When deleting a playlist using an alias name from Compel, the actual playlist is deleted along with the alias only if there are no other aliases that exist for that playlist. However, if the playlist is deleted using the actual playlist name, then only the actual playlist itself is deleted and not any of its aliases.
To edit the alias in an open playlist:
1. From the menu bar, click Edit Alias. The Playlist Builder opens the Alias box for editing.
alias list
2. To create or delete a playlist’s alias:
To...
create an alias delete an alias
In the Alias box... type the alias name in the Add New Alias text box. Click Add
New Alias. The Playlist Builder adds the alias to the alias list.
select an alias from the alias list and click Delete Selected Alias. The
Playlist Builder deletes the alias.
Adding on-screen graphics
Any item in a playlist can display an on-screen graphic, also referred to as OSG or bugs. To add an OSG to any or all items in an open playlist:
1. In the active playlist, select the appropriate Show OSG check box for an item to display the selected OSG.
Show OSG check boxes
OSG dropdown list X & Y coordinates
Intro/Outro
Time box
58
2. Select an image from the OSG drop-down list.
800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
3. Enter the X and Y coordinates for the graphic in the XPos and YPos boxes. The maximum
X value is 512 and the maximum Y value is 480.
Note: The coordinate (0X, 0Y) is the most upper left corner of the screen.
4. Enter the time in milliseconds for the intro/outro in the Intro/Outro Time box. This setting determines at what times the OSG appears and fades away during the item’s play. For example, if the Intro/Outro Time is set for 1,000 msec (or a second), the OSG appears a second after the start of the item and disappears a second before the item’s end.
Setting a start time for a playlist
The Playlist Builder lets you set specific start times for a playlist and its individual items. If any item has a set start time, then the playlist must also have a start time set for the first item. For more information on timed playlists, see Playlist styles on page 53.
Note: When a playlist with a start time is scheduled for playback, then the decoder is turned off
until the iPump 6400’s local system clock equals the playlist’s start time.
Caution: Start times should not be set for items that follow Random or Sequential tagged items since the actual play times for these cannot be determined.
To set a start time for an item in an open playlist:
1. In the active playlist, select the Set Start? check box for the first item The Playlist Builder opens the Alias box for editing.
www.wegener.com
2. Enter the start time in the hours, minutes, seconds format (hh:mm:ss) and click OK. The
Playlist Builder sets the new start time for the playlist.
Note: The iPump 6400 uses a 24-hour clock, so enter 11:30 PM as 23:30:00.
3. If there are any additional items requiring a start time, select the Set Start? check box for the item.
4. Enter the start time in the hours, minutes, seconds format (hh:mm:ss) and click OK.The
Playlist Builder sets the new start time for the item.
5. Repeat steps 3 and 4 until all start times are set.
Note: If the start time for an item interrupts the preceding item’s end time, the Playlist
Builder highlights the preceding item’s end time in orange. If the start time for an item lags the preceding item’s end time, the Playlist Builder highlights the preceding item’s end time in green.
800009-01 Rev. J
This set start time interrupts the previous end time
59
Operation
iPump 6400
Help
For answers to frequently asked questions or the current manual in PDF:
1. Click the Help tab on the web browser.
2. To view the FAQs, use the scroll bar on the right side of the browser.
3. To view the manual in PDF, you must have Adobe Reader® installed. (Download for free at: www.adobe.com). Click the View Online Manual hyperlink to open the PDF.
Figure 3.29: iPump 6400 web browser Help tab
3.10 Unit Software Switch
Software
Switch
Procedure
The Unit Software Switch function is only available from the iPump 6400 front panel.
Figure 3.30 and Table 3.13 detail the procedure to switch between versions of application software loaded on the iPump 6400.
Figure 3.30: Menu navigation to switch unit software
60 800009-01 Rev. J www.wegener.com
Verify
Software
Version
Procedure
iPump 6400 User’s Manual
Table 3.13: Procedure for switching iPump 6400 software version
Begin from the Unit Software Switch to B-Up screen.
Step Press
1.
Displayed/Field Details
ENTER SW FROM v111 TO v222 PRESS <ENTER>
2.
Note: v111 and v222 represent the current and available software versions.
Press ENTER to begin loading the alternate software version or press ESC to cancel the switch.
ENTER V x.x Booting, please wait . . . . .
Note: Vx.x represents the version number that the
iPump 6400 displays. It may not correspond to the actual loading version.
The expanding and contracting ellipsis indicate that the alternate software is loading.
Screen Type
Menu
Status
Display
After switching the software, you may want to verify that the intended software is in use. Use the procedure below to verify the version of software in use on the iPump 6400.
1. Navigate to the Version Info screen as shown in Figure 3.31.
2. Press ENTER. The iPump 6400 displays the version number of the software in use.
Figure 3.31: Menu navigation to Version Info
www.wegener.com
800009-01 Rev. J 61
Operation
62 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
C
HAPTER
4 M
AINTENANCE AND
T
ROUBLESHOOTING
4.1 Maintenance
Maintenance of the iPump 6400 is limited to keeping the chassis clean and ensuring that cables remain firmly connected. Occasionally wipe the exterior with a soft, damp cloth to remove any accumulated dust and dirt and check that cables are securely attached.
The iPump 6400 incorporates security labels over some of the screws. There are no userserviceable components within the iPump 6400. Tampering with the security labels or opening the unit will void your warranty. If you have any questions, contact WEGENER’s
Customer Service Department at the address or numbers listed under Customer Service.
4.2 Troubleshooting
This section is not intended as an exhaustive list of all possible situations. Please contact us
(see Chapter 5 Customer Service on page 67) with any problems you cannot resolve independently.
If you are experiencing any difficulties, first check the LCD and LED indicators on the iPump
6400 to determine if any warnings or alarms are active. See Table 4.1: iPump 6400 LED
indicator descriptions on page 64 for descriptions of LED states.
No Functions
At All
No Output
If the unit is not functioning at all and neither the LCD nor any LEDs are lit, there may be a loss of ac power. Do the following:
1. Check that the power switch is set to the ON position. See Figure 2.2: iPump 6400 rear-
panel connector locations on page 13.
2. Check that ac power cord is firmly connected at both ends.
3. Check that your ac power source is supplying ac power.
4. Press the ENTER button on the front panel.
If the unit is receiving power and there are no alarm or warning conditions indicated by the front panel, but there is still no output, check your monitoring equipment for proper function.
Also check to determine whether the program or file is "blank".
Trouble Using
Browser
Interface
If the iPump 6400 appears to be functioning normally with no alarm or warning conditions, but you cannot use the web browser interface, first check that you are using the correct IP address. (See Web Browser Operations Startup on page 24.)
If the address is correct, but the interface still does not function, check your computer’s IP settings and consult your network administrator for additional help.
www.wegener.com
800009-01 Rev. J 63
Maintenance and Troubleshooting
LED
Indicators
The iPump 6400 displays only one alarm or warning condition at a time on the LCD. When multiple alarm or warning conditions exist, the iPump 6400 displays those conditions in the order of importance with the most critical condition displaying first. After clearing the more critical item(s), the iPump 6400 displays any additional alarms or warnings.
COMPEL
AUTH
WARNING
ALARM
Table 4.1: iPump 6400 LED indicator descriptions
Indicator Label Color and State
CARRIER
RECORD
GREEN constant
GREEN slow blink
GREEN constant
Off
DOWNLOAD GREEN constant
Off
LAN GREEN constant
GREEN slow blink
Off
GREEN constant
GREEN fast blink
GREEN slow blink
Off
GREEN constant
GREEN slow blink
Off
AMBER constant
Off
RED constant
RED slow blink
Off
Meaning
Receiver is tracking carrier.
Receiver is not tracking carrier.
iPump 6400 is recording a program.
iPump 6400 is not recording.
iPump 6400 is downloading a file via Compel.
iPump 6400 is not downloading.
Light network activity over the iPump 6400 ’s LAN interface
Heavy network activity over the iPump 6400 ’s LAN interface iPump 6400 observed no packet transfers on the LAN interface during the last 20 seconds.
iPump 6400 has received a Compel command within the last two minutes.
iPump 6400 has been addressed by Compel within the last five seconds.
iPump 6400 is in tracking mode, Compel is required, but no Compel command has been received within the last two minutes.
Compel is not required and not received within the last two minutes; or, iPump 6400 is not in tracking mode.
Current transport stream is protected by conditional access (CA) and iPump 6400 is authorized and descrambling.
Current transport stream is protected by conditional access (CA) but iPump 6400 is unauthorized.
Tracked channel is not scrambled.
One or more warning conditions exist. Read warning information from front-panel LCD.
No warning conditions exist.
One or more alarm conditions exist. Read alarm message from LCD.
Boot Fail Mode. All other LEDs are turned off.
No alarm condition exists.
64 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
Fault (Alarm/
Warning)
Indications
Front Panel Message
App Self-testing
Reverted to B-up app
App SW D-load fail
No Carrier lock
Eb/No Margin warning
No PAT
PAT Disappeared
Program not found
No COMPEL PID
Lost COMPEL PID
Unauthorized for CA
No PMT
Bad PMT
Faults in the unit operation trigger warning and alarm indications. The iPump 6400 presents the indications to the local user via:
!" front-panel LEDs
!"
LCD information screens
!" the state of Alarm Relays
!" transmitting to a remote monitoring point using Return Path.
PMT Disappeared
Video not found
Aud not in PMT Dec#
Aud not found Dec#
No audio for Dec#
Audio Underrun Dec#
Aud CMD muted Dec#
Recovery
Using backup setting
No Genlock Sync Dec#
Genlock Unstable D#
Modem Failure
No Modem Dial Tone
Modem Busy Signal
Possible Cause
New application in self-test
User-requested application failed self-test and Unit reverted to Backup application
[until next commanded app switch]
Download of application software failed so backup flash space still shows
INCOMPLETE [until good download]
Carrier not yet acquired
Eb/No value less than sum of Threshold + Margin-evaluated over 10 sec. intervals
No PAT (Program Association Table) found in initial Verify Transport [if a warning, while occurring & carrier/ASI still locked]
PAT lost after first being verified
Requested program number not listed in current PAT
No COMPEL PID packets received >2 minutes, since signal acquisition
COMPEL PID packets lost (if valid COMPEL seen since signal acquisition and
COMPEL disappeared for >2 minutes)
Unit unauthorized: No addressed conditional access (CA) messages and stream is encrypted
No PMT (Program Map Table) found for Program listed in PAT
PMT PID not found or data corrupt
PMT disappears or becomes corrupt
Video PID not found
No audio PID found in PMT with assigned language descriptor for decoder number-#
Audio PID not found for decoder number-#
No audio allocated to wildcard assigned to decoder number-#
Audio PES data becomes unavailable (buffer underflow) for decoder number-#
Audio output is command muted for decoder number-#
Auto-Recovery in progress
Current settings derived from successful Auto- Recovery [until local or network user setting command]
No Genlock sync, while Enabled for decoder number-#
Excessive color-reference resets, lost/re-locks of genlock ref, while enabled for decoder number-#
Defective Modem or unacceptable connection to Modem
No dial tone on phone line
Got busy signal
www.wegener.com
800009-01 Rev. J 65
Maintenance and Troubleshooting
Front Panel Message
No Answer on Dialout
No PPP Connection
File Doesn't Exist
Invalid File Format
Disk Usage > 90%
Cannot Open File
Possible Cause
Called number didn't answer
PPP connection couldn't be established.
File to play/stream doesn't exist
File to play/stream is an unsupported format
Storage device is approaching maximum capacity
File to play/stream can't be opened
66 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
C
HAPTER
5 C
USTOMER
S
ERVICE
5.1 Warranty
The following warranty applies to all Wegener Communications products including the
iPump 6400 Professional Media Server:
All Wegener Communications products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Wegener
Communications' obligation under this warranty is limited to repairing or, at Wegener
Communications' option, replacing parts, subassemblies, or entire assemblies.
Wegener Communications shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are no other warranties, express or implied, except as stated herein.
5.2 Technical Support
If the unit should fail to perform as described, if you need help resolving problems with your
iPump 6400, or for questions about obtaining service for your iPump 6400, please contact
Wegener Communications Customer Service at (770) 814-4057, Fax (678) 624-0294, or email [email protected].
To return a product for service:
1. Obtain a Return Material Authorization (RMA) number by completing and faxing a copy of the RMA Request Form to (678) 624-0294. Or you may e-mail the same information to:
2. To help us identify and control returned units, plainly write the RMA number on the outside of the product-shipping container. This will help us return your unit to you as quickly as possible.
3. Return the product, freight prepaid, to the address below:
Service Department RMA# ________
Wegener Communications, Inc.
359 Curie Drive
Alpharetta, GA 30005
Note: All returned material must be shipped freight prepaid. C.O.D. shipments will not be accepted.
www.wegener.com
800009-01 Rev. J 67
Customer Service
This page intentionally left blank
68 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
I
NDEX
A
AC definition . . . . . . . . . . . . . . . . 8 access, see Conditional Access address customer service . . . . . . . . . . 67 manual comments . . . . . . . . . . 1 return materials . . . . . . . . . . . 67
AES/EBU . . . . . . . . . . . . . . . . . . 16
AFD definition . . . . . . . . . . . . . . . 8 air flow . . . . . . . . . . . . . . . . . . . . 11 alarms contact closure . . . . . . . . . . . . . 4 definition . . . . . . . . . . . . . . . . . . 8 front panel indicator . . . . . . . . 22 genlock . . . . . . . . . . . . . . . . . . 39 loss of carrier . . . . . . . . . . . . . 23 multiple . . . . . . . . . . . . . . . . . . 22
SNR . . . . . . . . . . . . . . . . . . . . 27 web indicator . . . . . . . . . . . . . 44 aliases . . . . . . . . . . . . . . . . . . . . 57 arrow buttons. . . . . . . . . . . . . . . 26 asset filter location . . . . . . . . . . . . . . . . . . 53 navigating . . . . . . . . . . . . . . . . 55 asset list location . . . . . . . . . . . . . . . . . . 53 navigating . . . . . . . . . . . . . . . . 55 playlists. . . . . . . . . . . . . . . . . . 53 assets random and sequential. . . . . . 54 start time. . . . . . . . . . . . . . . . . 59 audio compression . . . . . . . . . . . 6 audio decoder . . . . . . . . . . . . . . 16 audio output. . . . . . . . . . . . . . . . . 6 authorized definition . . . . . . . . . . . . . . . . . . 8 indicator . . . . . . . . . . . . . . . . . 22
B browser, see web browser bugs. . . . . . . . . . . . . . . . . . . . . . 58 buttons, front-panel . . . . . . . . . . 20
C
CA, see Conditional Access carrier definition . . . . . . . . . . . . . . . . . . 8 indicator . . . . . . . . . . . . . . . . . 22 circuit overloading . . . . . . . . . . . 12 classical MPEG . . . . . . . . . . . . . 47 cleaning . . . . . . . . . . . . . . . . . . . 63
Click to Stop hyperlink. . . . . 49, 51
Compel commands . . . . . . . . . . . . 19, 22 control . . . . . . . . . . . . . 4, 19, 36 date/time setup front panel. . . 30 date/time setup web browser . 41 definition . . . . . . . . . . . . . . . . . . 8 file download . . . . . . . . . . . . . 22 indicator . . . . . . . . . . . . . . . . . 22 iPump 6400 operations . . . . . 19
LED indicator . . . . . . . . . . . . . 22
MediaPlan software . . . . . . . . . 2 playlist alias . . . . . . . . . . . . . . 58 record and play . . . . . . . . . . . 51 signal . . . . . . . . . . . . . . . . . . . 19
Conditional Access . . . . . . . . . . . 4
Compel control options . . . . . . . . . . . . . . . . . . . 5 type . . . . . . . . . . . . . . . . . . . . . 5 connections ac power. . . . . . . . . . . . . . . . . 13
AES/EBU digital audio . . . . . . 16 alarm connector . . . . . . . . . . . 14 audio decoder . . . . . . . . . . . . 16 audio output . . . . . . . . . . . . . . 13 auxiliary audio output . . . . . . . 13 connector details . . . . . . . . . . 14 contact closure/opening . . . . . 13
Ethernet . . . . . . . . . . . 13, 14, 15
LAN . . . . . . . . . . . . . . . . . . . . 13 multiswitch . . . . . . . . . . . . . . . 17
RF input . . . . . . . . . . . . . . . . . 13 video output . . . . . . . . . . . . . . 13 contact closure . . . . . . . . . . . 4, 14
Current Channel settings. . . 28, 29 customer service phone number 67
D date/time setup
Compel. . . . . . . . . . . . . . . . . . 30
Compel control . . . . . . . . . . . . 41 front panel . . . . . . . . . . . . . . . 30 web browser. . . . . . . . . . . . . . 41
Daylight Savings Time. . . . . . . . 30 decoder optional second . . . . . 37, 45, 46 optional third . . . . . . . . . . . . . 37 set up . . . . . . . . . . . . . . . . . . . 37 settings, Live Program Play . . 45
DHCP . . . . . . . . . . . . . . . . . . . . 24 dimensions . . . . . . . . . . . . . . . . . 7 download indicator . . . . . . . . . . . . . . . . . 22 downloading . . . . . . . . . 2, 3, 4, 48 definition. . . . . . . . . . . . . . . . . 22
DVB definition . . . . . . . . . . . . . . . 8
Dynamic Host Configuration
Protocol. . . . . . . . . . . . . . . . 24 dynamic setup . . . . . . . . . . . . . . 24
E earthing . . . . . . . . . . . . . . . . . . . 12
Eb/No definition. . . . . . . . . . . . . . 8 editable fields . . . . . . . . . . . 20, 21 editing fields on LCD . . . . . . . . . 20
EIA definition . . . . . . . . . . . . . . . . 8 e-mail customer service . . . . . . . . . . 67 manual comments . . . . . . . . . . 1 return materials . . . . . . . . . . . 67
Enter button. . . . . . . . . . . . . . . . 20 initial startup . . . . . . . . . . . . . . 23
LCD navigation. . . . . . . . . . . . 26 normal shutdown . . . . . . . . . . 23 normal startup . . . . . . . . . . . . 23 push button . . . . . . . . . . . . . . 20 environment, operating . . . . . . . . 7
ESC button . . . . . . . . . . . . . . . . 26 home screen . . . . . . . . . . . . . 26
LCD navigation. . . . . . . . . . . . 26
Escape button, see ESC button
Ethernet connections . . . . . . . . 13, 14, 15 definition. . . . . . . . . . . . . . . . . . 8
F
FAQs . . . . . . . . . . . . . . . . . . . . . 60 fax number customer service . . . . . . . . . . 67 manuals . . . . . . . . . . . . . . . . . . 1 return materials . . . . . . . . . . . 67
Wegener Communications. . . . ii
File Management . . . . . . . . . . . 49
File Manager list . . . . . . . . . . . . 50 filename limits . . . . . . . . . . . . . . 50 files
www.wegener.com
800009-01 Rev. J 69
deleting . . . . . . . . . . . . . . . . . . 50 downloading . . . . . . . . . . . . . . . 3 managing . . . . . . . . . . . . . . . . . 2 naming . . . . . . . . . . . . . . . 47, 50 playing. . . . . . . . . . . . . . . . . 2, 48 purging . . . . . . . . . . . . . . . . . . 47 recording . . . . . . . . . . . . . . . 2, 46 renaming . . . . . . . . . . . . . . . . . 50 serving to LAN . . . . . . . . . . . . . 4 storing . . . . . . . . . . . . . . . . . . . . 2 streaming and routing . . . . . . . 51 viewing . . . . . . . . . . . . . . . . . . 50
Files tab . . . . . . . . . . . . . . . . . . . 50
Follow Tune . . . . . . . . . . . . . 39, 45 front panel additional unit setup . . . . . . . . 30 alarm conditions . . . . . . . . . . . 22 controls . . . . . . . . . . . . . . . . . . 19 date/time setup . . . . . . . . . . . . 30 figure . . . . . . . . . . . . . . . . . . . . 19
HTTP Proxy IP . . . . . . . . . . . . 32
HTTP Proxy Port. . . . . . . . . . . 32 initial unit setup . . . . . . . . . . . . 26
IP address. . . . . . . . . . . . . . . . 25
LED indicators. . . . . . . . . . . . . 21 operation . . . . . . . . . . . . . . . . . 26 push buttons . . . . . . . . . . . . . . 20
Return Path. . . . . . . . . . . . . . . 32 screen park . . . . . . . . . . . . . . . 36 startup/shutdown. . . . . . . . . . . 23 unit software switch. . . . . . . . . 60
Front panel navigation . . . . . . . . 33
FTP definition. . . . . . . . . . . . . . . . 8 functions
Compel Control . . . . . . . . . . . . . 4
Contact Closure/Alarms . . . 4, 14
File Downloads . . . . . . . . . . . . . 3
File Management . . . . . . . . . . . 2
File Play . . . . . . . . . . . . . . . 2, 48
Files Served to LAN . . . . . . . . . 4
HTML Control . . . . . . . . . . . 4, 24 iPump 6400. . . . . . . . . . . . . . . . 2
Live Program Play. . . . . . . . 2, 45 monitor iPump status . . . . . 2, 43 play recorded program . . . . . . 48 record program . . . . . . . . . . . . 46
Record Program to File. . . . 2, 46 unit software switch. . . . . . . . . 60
G
GB definition . . . . . . . . . . . . . . . . 8
Genlock alarm. . . . . . . . . . . . . . . . . . . . 39 clear alarm . . . . . . . . . . . . . . . 39 disable . . . . . . . . . . . . . . . . . . 38 horizontal time delay. . . . . . . . 38 inactive . . . . . . . . . . . . . . . . . . 39 setup . . . . . . . . . . . . . . . . . . . . 38 subcarrier phase . . . . . . . . . . . 38 glossary . . . . . . . . . . . . . . . . . . . . 8 grounding. . . . . . . . . . . . . . . . . . 12
H
Help
FAQs. . . . . . . . . . . . . . . . . . . . 60
PDF of manual . . . . . . . . . . . . 60 web browser . . . . . . . . . . . . . . 60
Help tab . . . . . . . . . . . . . . . . . . . 60
Horizontal Time Delay . . . . . . . . 38
HTML Control . . . . . . . . . . . . 4, 24
HTTP Proxy IP. . . . . . . . . . . . . . 32
HTTP Proxy Port . . . . . . . . . . . . 32
HTTP Proxy screens . . . . . . . . . 32
I
IEEE definition . . . . . . . . . . . . . . . 8 immediate style playlists . . . . . . 48 initial setup front panel. . . . . . . . . . . . . 26-31 web browser . . . . . . . . . . . . . . 36 initial startup. . . . . . . . . . . . . . . . 23
Intro/Outro Time. . . . . . . . . . . . . 59
IP address . . . . . . . . . . . 24-25, 42
IP multicast iPump 6400 functions . . . . . . . . 2
LAN setting . . . . . . . . . . . . . . . 46 routing. . . . . . . . . . . . . . . . . . . . 3
SAT setting . . . . . . . . . . . . . . . 45 video streams . . . . . . . . . . . . . . 3
IP settings . . . . . . . . . . . . . . 39, 45
IP setup . . . . . . . . . . . . . . . . . . . 24
IP unicast
LAN setting . . . . . . . . . . . . . . . 46 iPump 615 . . . . . . . . . . . . . . . . . 43 iPump 6400 overview . . . . . . . . . . . . . . . . . . 1
K kbps definition . . . . . . . . . . . . . . . 8
L labels, security . . . . . . . . . . . . . . 63
LAN definition . . . . . . . . . . . . . . . . . . 8 indicator . . . . . . . . . . . . . . . . . 22
LCD . . . . . . . . . . . . . . . . . . . . . . 20 definition . . . . . . . . . . . . . . . . . . 8 menu structure . . . . . . . . . . . . 26 navigation . . . . . . . . . . . . . . . . 26
LED definition . . . . . . . . . . . . . . . . . . 8 indicators . . . . . . . . . . . . . . . . 21 light-emitting diodes, see LED liquid-crystal display, see LCD
LNB
DC power setup . . . . . . . . . . . 29 definition . . . . . . . . . . . . . . . . . . 8
LNB LO value . . . . . . . . . . . . . 27 type selection, front panel. . . . 28 type selection, web . . . . . . . . . 40 types . . . . . . . . . . . . . . . . . 28, 40 local control disabled . . . . . . . . . . . . . . . . . . 4 local oscillator, LNB selection front panel . . . . . . . . . . . . . . . . . . 28 local oscillator, LNB selection web
40
Loop Forever . . . . . . . . . . . . 46, 54 power outage . . . . . . . . . . . . . 53
Loop N Times . . . . . . . . . . . . . . 54
Loop on Last . . . . . . . . . . . . . . . 54 looping style. . . . . . . . . . . . . 48, 54
Loop Forever . . . . . . . . . . . . . 54
Loop N Times . . . . . . . . . . . . . 54
Loop on Last. . . . . . . . . . . . . . 54 looping styles. . . . . . . . . . . . . . . 54
LOS . . . . . . . . . . . . . . . . . . . . . . 52
M mechanical loading . . . . . . . . . . 11 media distribution . . . . . . . . . . . . 2 menu structure. . . . . . . . . . . . . . 26 menus hierarchy diagram. . . . . . . . . . 26
IP Address . . . . . . . . . . . . . . . 24
LNB DC power setup . . . . . . . 29
Navigation. . . . . . . . . . . . . . . . 26
Record setup . . . . . . . . . . . . . 48
SNR Alarm/Warning Setup 28, 29 model number options indicated by . . . . . . . . . 4 modem setup. . . . . . . . . . . . . . . 42 mounting . . . . . . . . . . . . . . . . . . 11 equipment rack . . . . . . . . . . . . 12
MPEG classical . . . . . . . . . . . . . . . . . 47 definition . . . . . . . . . . . . . . . . . . 8
MPEG Under IP . . . . . . . . . . . 47
Msps definition. . . . . . . . . . . . . . . 8
70 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual multicast streams. . . . . . . . . 39, 45
Multiswitch connection . . . . . . . . . . . . . . . 17 operation . . . . . . . . . . . . . . . . 29 multiswitch, LNB selection web . 40
Multiswitch, LNB type . . . . . . . . 28
N network settings. . . . . . . . . . . . . 42 normal shutdown . . . . . . . . . . . . 23 normal startup . . . . . . . . . . . . . . 23
O online manual . . . . . . . . . . . . . . 60 on-screen graphic, see OSG operating temperature . . . . . . . . 11 operation from web browser . . . . . . . . . . 24 front panel . . . . . . . . . . . . . . . 26 front panel, optional screens . 33 iPump 6400 . . . . . . . . . . . . . . 19 options, iPump. . . . . . . . . . . . . . . 4
OSG adding. . . . . . . . . . . . . . . . . . . 58 definition . . . . . . . . . . . . . . . . . . 8 overview, iPump 6400 . . . . . . . . . 1
P packet ID . . . . . . . . . . . . . 8, 39, 65 parameters changing. . . . . . . . . . . . . . . . . 20
PAT . . . . . . . . . . . . . . . . . . . . . . 65 definition . . . . . . . . . . . . . . . . . . 8 phone number customer service . . . . . . . . . . 67 physical description . . . . . . . . . . . 2
PID. . . . . . . . . . . . . . . . . . . . 39, 65 definition . . . . . . . . . . . . . . . . . . 8 pinouts alarm connector . . . . . . . . . . . 15
LAN connector . . . . . . . . . . . . 15
Play a file list . . . . . . . . . . . . . . . 48 playing live program . . . . . . . . . . . . 2, 44 live program checklist . . . . . . . 44 live program procedure . . . . . 45 stored file . . . . . . . . . . . . . . 2, 48 playlist active . . . . . . . . . . . . . . . . . . . 56 adding assets . . . . . . . . . . . . . 55 aliases . . . . . . . . . . . . . . . . . . 57 builder. . . . . . . . . . . . . . . . . . . 53 creating. . . . . . . . . . . . . . . . . . 54 customizing . . . . . . . . . . . . . . 57 deleting assets . . . . . . . . . . . . 56 deleting with alias . . . . . . . . . . 58 duplicate. . . . . . . . . . . . . . . . . 55 editing. . . . . . . . . . . . . . . . . . . 55 editing the description . . . . . . 57 immediate. . . . . . . . . . . . . . . . 53
LOS . . . . . . . . . . . . . . . . . . . . 52 management . . . . . . . . . . . . . 52 moving assets . . . . . . . . . . . . 56 opening . . . . . . . . . . . . . . . . . 54 overview . . . . . . . . . . . . . . . . . . 2 playback . . . . . . . . . . . . . . . . . 48 procedures . . . . . . . . . . . . . . . 54 saving. . . . . . . . . . . . . . . . . . . 55 start time . . . . . . . . . . . . . . . . 59 styles . . . . . . . . . . . . . . . . . . . 53 timed . . . . . . . . . . . . . . . . . . . 53 types. . . . . . . . . . . . . . . . . . . . 53
Playlist builder . . . . . . . . . . . . . . 53 adding assets . . . . . . . . . . . . . 56
Playlist tab . . . . . . . . . . . . . . . . . 53
PMT. . . . . . . . . . . . . . . . . . . . . . 65 definition . . . . . . . . . . . . . . . . . . 8 power ac input. . . . . . . . . . . . . . . . . . . 7
DC to LNB . . . . . . . . . . . . . . . . 6 switch . . . . . . . . . . . . . . . . . . . 23
PPP definition . . . . . . . . . . . . . . . . . . 8 precautions . . . . . . . . . . . . . . . . 11
Pro Audio Decoder . . . . . . . . . . 16 program definition . . . . . . . . . . . . . . . . . . 8
Program Association Table . . 8, 65
Program Map Table. . . . . . . . 8, 65 program number definition . . . . . . . . . . . . . . . . . . 9 program, playing recorded . . . . 46 push buttons . . . . . . . . . . . . . . . 20
Q
QPSK definition . . . . . . . . . . . . . . 9
R rack installation . . . . . . . . . . . . . 12 random tag . . . . . . . . . . . . . . . . 54 random tags . . . . . . . . . . . . . . . 54
Rec/Play tab . . . . . . . . . . . . . . . 47 record indicator . . . . . . . . . . . . . . . . . 22
Record/Play chart . . . . . . . . . . . 49 recording . . . . . . . . . . . . . . . . 2, 46 reliable earthing. . . . . . . . . . . . . 12
Return Material Authorization
(RMA) . . . . . . . . . . . . . . . . . 67
Return Path . . . . . . . . . . . . . . . . 32
Return Path Setup. . . . . . . . . . . 43
RF definition. . . . . . . . . . . . . . . . . . 9 setup screen . . . . . . . . . . . . . 27 specification . . . . . . . . . . . . . . . 6
RF setup for live programs . . . . . 26-??, 45 initial. . . . . . . . . . . . . . . . . . . . 27
Routing . . . . . . . . . . . . . . . . . . . . 3
RU . . . . . . . . . . . . . . . . . . . . . . . 12
S safety. . . . . . . . . . . . . . . . . . . . . . 7 satellite receive settings . . . . . . 39
Schedule tab . . . . . . . . . . . . . . . 52 scheduled operations . . . . . . . . 51 schedules . . . . . . . . . . . . . . . . . 51 scheduling . . . . . . . . . . . . . . . . . . 3 screen park setup . . . . . . . . . . . 36 screens
Date/Time setup LCD. . . . . . . 30 home . . . . . . . . . . . . . . . . . . . 26
HTTP Proxy IP . . . . . . . . . . . . 32
HTTP Proxy Port . . . . . . . . . . 32
LCD . . . . . . . . . . . . . . . . . . . . 20
LCD menu . . . . . . . . . . . . . . . 26
LNB DC power . . . . . . . . . . . . 29
LNB type . . . . . . . . . . . . . . . . 29
Return Path . . . . . . . . . . . . . . 33
RF current channel. . . . . . . . . 28
RF setup . . . . . . . . . . . . . . . . 27 screen park . . . . . . . . . . . . . . 36 unit label. . . . . . . . . . . . . . . . . 31
Unit Software Switch . . . . . . . 60 user-input . . . . . . . . . . . . . . . . 20 version info. . . . . . . . . . . . . . . 61 selectable field . . . . . . . . . . . . . 21 selectable fields. . . . . . . . . . . . . 20 sequential tag . . . . . . . . . . . . . . 54 sequential tags . . . . . . . . . . . . . 54 settings current channel . . . . . . . . 28, 29 date/time front panel . . . . . . . 30 date/time web browser . . . . . . 41
Daylight Savings Time . . . . . . 30 decoder . . . . . . . . . . . . . . . . . 45 downlink frequency . . . . . . . . 28
HTTP Proxy . . . . . . . . . . . . . . 32
IP . . . . . . . . . . . . . . . . . . . 39, 45
www.wegener.com
800009-01 Rev. J 71
LAN IP multicast . . . . . . . . . . . 46
LAN IP unicast . . . . . . . . . . . . 46
LNB Types . . . . . . . . . . . . . . . 29
Modem . . . . . . . . . . . . . . . . . . 42
Modem, front panel . . . . . . . . . 33 network . . . . . . . . . . . . . . . . . . 42 program number . . . . . . . . . . . 28
Return Path. . . . . . . . . . . . 33, 43
RF pre-configured . . . . . . . . . . 27
RF-mod/FEC ratio. . . . . . . . . . 28
SAT IP multicast . . . . . . . . . . . 45 satellite receive . . . . . . . . . . . . 39 screen park . . . . . . . . . . . . . . . 36 time zone . . . . . . . . . . . . . 30, 41 transport data rate. . . . . . . . . . 28 transport input . . . . . . . . . . . . . 39 unit label screen . . . . . . . . . . . 31
Setup tab . . . . . . . . . . . . . . . . . . 37 shutdown . . . . . . . . . . . . . . . . . . 23 shutting down. . . . . . . . . . . . . . . 23
SMB . . . . . . . . . . . . . . . . . . . . . . . 9
SNR alarm threshold, front panel. .
27
SNR margin warning, front panel. .
27 software switch . . . . . . . . . . . . . . . . . . . 60 upgrade. . . . . . . . . . . . . . . . . . 60 version . . . . . . . . . . . . . . . . . . 60 specifications, iPump . . . . . . . . . . 6 startup . . . . . . . . . . . . . . . . . . . . 23 initial . . . . . . . . . . . . . . . . . . . . 23 normal . . . . . . . . . . . . . . . . . . . 23 web browser . . . . . . . . . . . . . . 24 static setup. . . . . . . . . . . . . . . . . 24 status alarms & warnings . . . . . . . . . 44 front panel LEDs . . . . . . . . . . . 21 web . . . . . . . . . . . . . . . . . . . . . 43
Status tab. . . . . . . . . . . . . . . 25, 44 stop record . . . . . . . . . . . . . . . . . . . 48 storage capacity. . . . . . . . . . . 5, 47 stream creation . . . . . . . . . . . . . . 3
Stream/Status box . . . . . . . . . . . 51
Streaming Files list . . . . . . . . . . 51
Streams tab . . . . . . . . . . . . . . . . 51
Subcarrier Phase . . . . . . . . . . . . 38 suggestions or comments . . . . . . 1 switch software . . . . . . . . . . . . . 60
T tab
Files . . . . . . . . . . . . . . . . . . . . 50
Help . . . . . . . . . . . . . . . . . . . . 60
Playlist . . . . . . . . . . . . . . . . . . 53
Rec/Play . . . . . . . . . . . . . . . . . 47
Schedule. . . . . . . . . . . . . . . . . 52
Setup . . . . . . . . . . . . . . . . . . . 37
Status . . . . . . . . . . . . . . . . . . . 44
Streams . . . . . . . . . . . . . . . . . 51 tags, random and sequential . . . 54 tape delay . . . . . . . . . . . . . . . . . . 2 technical specifications . . . . . . . . 6 temperature . . . . . . . . . . . . . . . . 11 time zone settings . . . . . . . . . . . . . . . 30, 41 shifting . . . . . . . . . . . . . . . . . . . 2
TMRA. . . . . . . . . . . . . . . . . . . 9, 11 transport input settings . . . . . . . 39
U unit label screen . . . . . . . . . . . . . . . . . . . 31 setup . . . . . . . . . . . . . . . . . . . . 31 unit shutdown. . . . . . . . . . . . . . . 23 unit software switch . . . . . . . . . . 60 universal/astra, LNB selection web
40
Universal/Astra, LNB type . . . . . 28 upgrade software . . . . . . . . . . . . 60 user input screens . . . . . . . . . . . 26
V
Version Info screen . . . . . . . . . . 61 video compression. . . . . . . . . . . . 6 video output . . . . . . . . . . . . . . . . . 6
W warnings front panel indicator . . . . . . . . 22 mounting. . . . . . . . . . . . . . . . . 11 web indicator . . . . . . . . . . . . . 44 warranty . . . . . . . . . . . . . . . . . . . 67 web browser access . . . . . . . . . . . . . . . . . . 25 alarms. . . . . . . . . . . . . . . . . . . 44 control setup procedure . . . . . 24
Files tab . . . . . . . . . . . . . . . . . 50
Help tab . . . . . . . . . . . . . . . . . 60
Playlist tab . . . . . . . . . . . . . . . 53
Rec/Play tab . . . . . . . . . . . . . . 47
Return Path . . . . . . . . . . . . . . 43
Schedule tab. . . . . . . . . . . . . . 52
Setup tab . . . . . . . . . . . . . . . . 37
Status tab . . . . . . . . . . . . . . . . 44
Streams tab . . . . . . . . . . . . . . 51 warnings . . . . . . . . . . . . . . . . . 44 web page opening. . . . . . . . . . . . . . . . . . 24 satellite receive settings . . . . . 45
X
X and Y coordinates . . . . . . . . . 59
X value maximum . . . . . . . . . . . 59
Y
Y value maximum . . . . . . . . . . . 59
72 800009-01 Rev. J www.wegener.com
iPump 6400 User’s Manual
www.wegener.com
800009-01 Rev. J 73
" 2007 Wegener Communications, Inc. All rights reserved.
800009-01 Rev. J
Tenth Edition: August 2007
Wegener Communications, Inc.
Technology Park/Johns Creek
11350 Technology Circle
Duluth, GA 30097-1502
Phone: 770-814-4000
Fax: 770-623-0698