Preparing for ECC Installation. Compuware ECC
Annonce
Annonce
2-1
Chapter 2.
Preparing for ECC Installation
This chapter contains important information that can help you prepare to install the
Enterprise Common Components (ECC) CD-ROM in the most efficient manner. Review it before beginning the installation process.
Required Components and Procedures
This section explains how to determine which parts of ECC need to be installed at your site and which chapters in this manual contain the applicable installation and customization procedures.
Component Selection
Different Compuware products utilize different portions of ECC. Use Table 2-1 to
determine which parts of ECC are needed at your site.
Notice that Compuware’s License Management System (LMS) is required for every mainframe product, while HCI and CSS are components for some products.
DVS can be used with the following products:
• Abend-AID version 9.0 or later
• CICS Abend-AID/FX version 4.4 or Abend-AID for CICS version 4.5 or later
Table 2-1.
Components Utilized by Each Compuware Product
Compuware Product LMS CSS
Abend-AID x x
Abend-AID Fault Manager
Abend-AID for CICS
DBA-XPERT for DB2
File-AID/Data Solutions
File-AID for DB2
File-AID for IMS x x x x x x x x
File-AID/MVS
File-AID/RDX
Hiperstation
STROBE
UNIFACE
Xpediter/CICS
Xpediter/Code Coverage
Xpediter/DevEnterprise
Compuware Workbench/MMC x x x x x x x x x* x x x x
HCI
x x x**** x** x** x
2-2
Enterprise Common Components Installation and Customization Guide
Table 2-1.
Components Utilized by Each Compuware Product
Compuware Product LMS CSS
Xpediter/TSO and IMS x x
HCI
Xpediter/Xchange x
* CSS is required only if creating profiles with source code indexing. CSS minimum release is 7.8.
** HCI can be optionally installed from the ECC CD. Please refer to the product’s documentation for customization instructions.
**** HCI is only required if using the Hiperstation viewer.
Required Procedures
Determining which chapters to use in this manual is actually very simple:
• Every mainframe Compuware product utilizes LMS. Therefore, every installation of a
Compuware product requires, at a minimum, that the latest maintenance be applied to LMS. So regardless of which product you are installing, you must perform the applicable procedures in the following chapters:
– Chapter 3, “Installing Enterprise Common Components” (if current release has not been previously installed)
– Chapter 4, “Applying Maintenance”
– Chapter 6, “LMS Customization”
• If the Compuware product you are installing requires CSS, you must also perform the
procedures in Chapter 5, “CSS Customization”. To configure Distributed Viewing
Support, see the Abend-AID Installation and Customization Guide.
The information within each chapter will direct you as to which steps apply in your situation.
Note: If you are installing the Host Communications Interface (HCI) components, refer to the appropriate product manual for specific customization/configuration instructions.
ECC Packaging
The ECC product media, which includes LMS, CSS, and HCI, is packaged for installation using System Modification Program Extended (SMP/E). SMP/E is a method developed by
IBM to install software products in the MVS environment.
SMP/E provides enhanced installation management and maintenance tracking capabilities. To facilitate SMP/E, the LMS, CSS, and HCI components are shipped on the
ECC CD-ROM separately from the products. The separate ECC CD contains both the base code and all cumulative, approved maintenance to-date. The ECC CD is shipped with each Compuware product that utilizes the CSS, HCI, or License Management components. To install the ECC, refer to Chapter 3, “Installing Enterprise Common
Components”.
The installation utilizes the Installation JCL Customization Facility consisting of a set of
REXX EXECs, JCL skeletons, and panels. This facility prompts you for the installation information and then builds the necessary jobs required to perform the SMP/E installation. You can also view reporting information from the installation facility, such as parameters and execution information.
Cumulative maintenance for ECC components is available for download from the
Compuware Frontline web site (frontline.compuware.com). It is recommended that you
Preparing for ECC Installation
2-3
periodically download and apply cumulative maintenance to keep your product version current.
SMP/E Installation and Maintenance
This section describes allocating SMP/E zones, SMP/E jobs to be executed, and libraries created during the SMP/E installation.
Allocating SMP/E Zones
SMP/E uses a VSAM cluster called a CSI (Consolidated Software Inventory) to control all product installation and maintenance information. Within a CSI, there are a minimum of 3 zones:
• Global zone
• Target zone
• Distribution zone
If a CSI is shared among several different products, there will be a single Global zone and a separate set of Target and Distribution zones for each product installed as illustrated in
Table 2-2. A site may have many CSIs, each with its own Global, Target, and Distribution
zones.
CAUTION:
To prevent possible conflicts, Compuware strongly recommends that all Compuware products and components distributed via SMP/E share a single Global zone reserved solely for Compuware products. Target and distribution zones should not be shared with other products or different releases of the same product.
If you need to maintain more than one release of CSS at a time under SMP/E control, then they must be installed into separate Target and Distribution Zones. If you try to install CSS into the same Target and Distribution Zones as an existing release, then
the previous release of CSS will be deleted.
Table 2-2.
SMP/E Zones
Target Zone Product 1
Target Zone Product 2
Target Zone Product 3
Global Zone
Distribution Zone Product 1
Distribution Zone Product 2
Distribution Zone Product 3
There are many different ways to allocate the zones. These methods include the following:
• The Global, Target, and Distribution zones may all reside together in a single VSAM cluster.
• The zones may each reside in separate VSAM clusters.
• The zones may each reside in a combination of VSAM clusters.
For example, you could have a single VSAM cluster for your Global zone and combine all the Target and Distribution zones in a second VSAM cluster. Or each set of Target and
Distribution zones may be combined in a single VSAM cluster. Compuware recommends that all zones be placed in separate VSAM clusters so that each zone can be backed up and restored individually, if necessary, without impacting any other zone.
2-4
Enterprise Common Components Installation and Customization Guide
Installing with SMP/E
The SMP/E portion of the installation process for LMS, CSS, and/or HCI consists of four basic steps:
1. Allocate and initialize the SMP/E datasets
2. Receive base and maintenance
3. Apply base and maintenance
4. Accept base and maintenance
After a function or maintenance (such as a PTF) has gone through the ACCEPT step, that becomes your current release-base level. At any time prior to the ACCEPT step, you may issue a RESTORE command to reset your Target libraries to the way they were as of the last ACCEPT command. The RESTORE command is used to remove maintenance, or even entire functions, while the ACCEPT command effectively sets a new base level of the release to which further maintenance will be applied. For more information about using the RESTORE command, refer to your site’s IBM SMP/E documentation.
Installing ECC Using JCL Customization Facility
The Installation JCL Customization Facility consists of a set of REXX EXECs, JCL skeletons, messages, and panels contained in the SMP/E installation sample library. The facility will display several panels to obtain installation information, and then will build the necessary jobs required to perform the SMP/E installation. The facility allows you to input SMP/E information, such as the Global SMP/E and SMP/E dataset high-level qualifiers, one time. They can then be used in all SMP/E installation jobs.
Note: Compuware recommends a minimum of ISPF/PDF version 3.5 when using the
Installation JCL Customization Facility. REXX is also required.
Using the Installation JCL Customization Facility, you can install any or all of the following:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
Please note the following:
• The HCI component must be installed only if you are using the following products:
– Abend-AID 11.02.00 and greater
– Abend-AID 9.0 through 11.01.00 for Distributed Viewing Support
– CICS Abend-AID/FX 4.4 or Abend-AID for CICS 4.5 or later
• If you need to install more than one component, Compuware recommends simultaneously installing those components.
ECC Component Prefixes and FMIDs
Compuware has registered the following element prefixes with IBM for the ECC components:
• LCX for CSS
• LMS for LMS
• LHC for HCI
The FMIDs for each component are listed below.
• MLCXnnn — CSS base code
Preparing for ECC Installation
2-5
• NLCXnnn — CSS Japanese support
• MLMSnnn — LMS base code
• MLHCnnn — HCI base code
ECC Installation Considerations
This section describes considerations for installing and customizing ECC that applies to
LMS, CSS, and/or HCI. Check your mainframe product installation documentation to verify if these any of the ECC component applications have already been installed. If
they are installed, you may consider only applying maintenance. See Chapter 4,
“Applying Maintenance” for more information.
Link Lists
Refer to your Compuware product documentation to determine whether the load library or libraries for your components should be placed in the link list.
PDS/E Support
ECC components support Partitioned Data Set/Extended (PDS/E) libraries. LMS, CSS, and/or HCI can be installed in PDS/E object libraries. Input source members for the CSS preprocessor or compiled listings for the CSS postprocessor may reside in a data PDS/E library. The following are supported for PDS/E libraries:
• PDS/E object libraries are supported with DFSMS 1.1 and above.
• PDS/E data libraries are supported with DFSMS 1.0 and above.
CSS Installation Considerations
This section describes considerations for installing Compuware Shared Services.
APF Authorization
Following IBM system integrity guidelines, Compuware recommends that your CSS load
Library (SLCXLOAD) NOT be APF-authorized. Depending on your MVS system installation options, libraries placed in the link list may be APF-authorized automatically.
Note: If you are using Abend-AID and Abend-AID is APF-authorized, then CSS should also be APF-authorized. If Abend-AID is not APF-authorized, then CSS should not be APF-authorized. The ONLY time the CSS load library should be APF-authorized is when you are using the Abend-AID load library as APF-authorized.
If you will be installing and configuring the Mainframe Common Components
Mainframe Interface TP, this component does require an APF-authorized library.
However, this component will install into a separate and very small load library
(SLCXAUTH) and the main CSS load library need not be APF-authorized subject to the note above.
CICS Load Library Definition
The CSS library must be included with Compuware product libraries in the CICS startup
JCL or RDO definitions for the following product:
• Xpediter/CICS (all supported releases)
2-6
Enterprise Common Components Installation and Customization Guide
TSO Logon PROCs
If the CSS load library is not in the link list and dynamic library allocation is not used, the CSS load library must be placed before all Compuware product load libraries in the
STEPLIB or ISPLLIB concatenations in the TSO logon PROC. The CSS message and panel libraries must be placed before all Compuware product message and panel libraries in the
ISPMLIB and ISPPLIB concatenations in the TSO logon PROC.
Beginning with CSS 6.0, the CSS load, message, and panel libraries can be dynamically
allocated for use with Compuware/VF. For more information, see “Step 5. Activate
Compuware ISPF Dialogs (Required)” on page 5-15.
Sharing CSS DDIO Files With Multiple CPUs
If you are sharing CSS DDIO files among multiple CPUs, the following qnames must be changed from LOCAL to GLOBAL enqueues.
• ABENDAID
• ABENDDAM
• ABENDSMF
• CWCATALG
Note: These qnames are needed for all products. Please refer to the individual
Compuware product documents with which CSS was distributed for other product requirements.
For IBM’s GRS (Global Resource Serialization), these qnames must be added to the inclusion RNL. This RNL is defined in the GRSRNLxx member of SYS1.PARMLIB for
MVS/XA and later. For pre-MVS/XA systems, these qnames are maintained in the
ISGSIRNL entry point of ISGGRNLO. Please consult the IBM product documentation for further details.
The CSS sample library contains an example of how qnames should be coded in the
GRSRNLxx member of SYS1.PARMLIB. See “CSS Sample Library Members” on page 2-10
for more information.
For resource serialization packages other than GRS (for example MIM), consult the product documentation for changing LOCAL to GLOBAL enqueues.
CSS Customer Modification Facility
The CSS Customer Modification Facility retrofits your site’s CSS restricted zaps to the
SMP/E environment. If you are migrating to the current CSS release from a CSS release prior to CSS 7.4, and have a restricted zaps applied to your system, you must use the CSS
Customer Modification Facility. For more information on using this facility, refer to the
“Using the Customer Modification Facility” appendix in the Compuware Shared Services
User/Reference Guide.
CSS Language Processor (LP)
The language processor captures information about a compiler listing and stores it in a source listing DDIO file. The majority of this information is gathered from the compiler listing, but optionally, SYSIN and SYSLIB are also examined. The source listing DDIO file may be in standard DDIO, shared directory, or database format. Releases prior to
Xpediter/TSO 7.3, Xpediter/CICS 7.6, and Abend-AID for CICS 4.5 do not support source listing shared directories. Instead, individual source databases may be specified for lower levels.
The language processor can be run using two methods:
• preprocessor
Preparing for ECC Installation
2-7
• postprocessor
You may use the preprocessor or postprocessor (whichever is best for your site as needed).
This section discusses the benefits of the preprocessor and the postprocessor and describes when to use them. See the appropriate language processor chapters in the
Compuware Shared Services User/Reference Guide for additional information on determining when to use the pre- or postprocessor.
Preprocessor
Some information about a program module is not always available from the compiler listing. The preprocessor, in addition to gathering information from the compiler listing, gathers information from SYSIN and SYSLIB. The preprocessor provides additional functionality for Xpediter/CICS and Xpediter/TSO, and is required for PL/I programs that use the %NOPRINT statement.
When setting up the language processors, Compuware recommends that you use the preprocessor instead of the postprocessor. The postprocessor should only be used in situations where compiled source listings have been stored.
Preprocessor Steps
1. Determines the proper compiler options required to process the listing file.
2. Automatically invokes the compiler or assembler to compile or assemble your source program.
3. Writes the listing to the DDIO file. An enhanced listing for COBOL programs can be produced, if desired. PL/I and Assembler listings are written to SYSPRINT. C listings are written to SYSCPRT.
Preprocessor Benefits
• Better handling of compiler errors. By using the preprocessor, you can avoid the potential problem of processing a listing with compiler errors. The preprocessor, in conjunction with the CONDDDIO parameter, internally checks the return code from the compiler and doesn’t write a DDIO listing that contains errors. For example, if you set the CONDDDIO parameter to 8, the preprocessor will write the compiler listing to the DDIO file unless the compiler return code exceeds 8. The preprocessor can process the compiler errors more effectively than the postprocessor. Compuware recommends that you use the preprocessor rather than the postprocessor.
• Capturing suppressed source code. When any of the following parameters are used, sections of source code can be suppressed from the compiler listing:
For COBOL
COPY SUPPRESS
For PL/I
%NOPRINT
For Assembler
PRINT OFF or PRINT NOGEN
For C
NOSHOWINC and NOEXPMAC
The preprocessor captures this information from SYSIN and SYSLIB, or by forcing on more revealing compiler options, then altering the listing to emulate the options you requested.
• Automated compiler options. The postprocessor requires that certain compiler options be specified in order to process all needed sections of the compiler listing.
The preprocessor can automatically pass the required options to the compiler.
• Simplified JCL. While the postprocessor requires that the user add a step after the compile step, the preprocessor requires only that minor modifications be made to your existing compile step.
2-8
Enterprise Common Components Installation and Customization Guide
Files Dynamically Allocated
The following files are dynamically allocated by the Compuware preprocessor. The attributes can be overridden by specifying a DD in the JCL.
Table 2-3.
Files Dynamically Allocated by the Preprocessor
DDname Attributes
CWPWRKn (0-6) BLKSIZE=19000 SPACE(TRK,(100,80)) UNIT=SYSDA
SORTWK01
TEMPLIN
BLKSIZE=19000 SPACE(TRK,(100,80)) UNIT=SYSDA
BLKSIZE=3200 SPACE(TRK,(200,100)) UNIT=SYSDA
CWPERRM
SYSPRINT
SYSOUT
SYSOUT=*
SYSOUT=*
SYSOUT=*
CWPPRTI (PL/I) BLKSIZE=19000 SPACE(TRK,(100,200)) UNIT=SYSDA
CWPPRTI (all other languages) BLKSIZE=16093 SPACE(TRK,(100,200)) UNIT=SYSDA DISP=MOD
CWPPDS2 SPACE (TRK,(100,80,80)) UNIT=SYSDA
CWPPRTO is dynamically allocated as a work file (for the preprocessor). SYSPRINT is where the listing goes.
Postprocessor
The postprocessor is executed as a single step and it can be a separate job. It reads in the listing created from the compiler. Information is gathered from the source listing, XREF, data maps, and object code sections of the listing. This information is stored in a DDIO file member and is used by various Compuware products.
While the preprocessor is the preferred method of loading the compiled listing to the
DDIO, there are situations that necessitate the use of the postprocessor as a viable alternative. This is commonly found in production environments where the listings may be archived. In order for the listings to populate the DDIO, they must be compiled using the required options specified in the appropriate language processor chapters in the
Compuware Shared Services User/Reference Guide. Note that these are usually the default options at many shops.
If the programs contain suppressed source code, certain additional control statements must be added to the language processor. Please view the Language Processor chapters in the Compuware Shared Services User/Reference Guide for the programming language desired for more details.
If the programs are compiled with OFFSET as well as OPT(imize), certain additional control statements must be added to the language processor. Please view the Language
Processor chapters in the Compuware Shared Services User/Reference Guide for the programming language desired for more details.
Postprocessor Benefits
• Exact match of compiled output listings with the executable load module. This is especially important in production environments where time is critical.
• Eliminates the risk of copybook or source code changes prior to recompiling the code since the listing reflects the code that is being executed.
• Significantly less time is needed to process source listings as opposed to recompiling the source code.
Preparing for ECC Installation
2-9
Language Processor DD Statements
Table 2-6 lists the DD statements for the Assembler, COBOL, PL/I, and C language processors. Not every DD Name applies to every language processor.
Table 2-4.
Language Processor DD Statements.
DDname Purpose
CWPWRK (0-6) LP work files
CWPPRMO
CWPDDIO
CWPPRTI
CWPPRTO
LP parameter input dataset
Target source listing DDIO file
Compiler listing input to postprocessor
Compiler listing output from postprocessor
CWPLOAD
CWPDECK
CWPERRM
Option LOAD or OBJECT module input to postprocessor
Option DECK module input to postprocessor
LP Error Messages
Note: CWPLOAD and CWPDECK correspond to the SYSLIN and SYSPUNCH compiler outputs. If you specify compiler option OBJECT, you should use CWPLOAD in your postprocessor JCL. If you specify compiler option DECK, you should use
CWPDECK in your postprocessor JCL. Do not feed the SYSLIN output into
CWPDECK or the SYSPUNCH output into CWPLOAD. The updated OBJECT contained in CWPLOAD and CWPDECK should be used in the program’s linkedit step. The preprocessor does not use CWPLOAD and CWPDECK.
Writing a Listing to a DDIO File
Several options exist to place listings in a DDIO file. Each option requires that some changes be made to your JCL. The type of changes needed depend on whether you are using the preprocessor or the postprocessor, and the type of debugging session. Refer to
“CSS Sample Library Members” for a list of the sample JCL that can be used for the
various options.
Testing and Debugging Programs
The actual method used for handling testing and debugging programs depends on whether you are preprocessing or postprocessing:
• Preprocessing — Run the preprocessor and link your program.
• Postprocessing — Compile your program, run the postprocessor, and then link your program.
With either of these methods, the language processor places a listing in the DDIO file whenever a program is compiled.
Debugging Production Programs
If the original compiler listing is available in machine-readable format, you can retrieve the listing and use it as input to the postprocessor in order to reprocess the listing and recreate it in the DDIO file. The postprocessor can process listings stored by most products.
Note: If the listing you use as input to the postprocessor contains any other information
(such as translator or link edit output), in addition to the compiler information, you may not obtain the desired results.
2-10
Enterprise Common Components Installation and Customization Guide
CSS Sample Library Members
The following list describes the members of the CSS sample JCL library that you may work with during installation (depending on your installation options). These members are distributed on the CSS distribution CD and updated via SMP/E. The members will be located in the following files after the Apply and Accept steps are complete.
• COMPWARE.MLCXnnn.SLCXCNTL (target library)
• COMPWARE.MLCXnnn.ALCXCNTL (distribution library) where nnn indicates the CSS release number.
To print the CSS sample library members, submit the JCL contained in library member
CXPRINT after the CD has been unloaded.
CWASSECD
CWASSECU
Security Exit program DSECT.
Sample Security Exit program.
CWCMTRHE
Sample customized horizontal translation table for mixed-case English.
CWCMTRHT
Sample customized horizontal translation table for uppercase English.
CWCMTRHU
Sample customized horizontal translation table for mixed-case English with Euro character.
CWCMTRVE
Sample customized vertical translation table for mixed-case English.
CWCMTRVT
Sample customized vertical translation table for uppercase English.
CWCMTRVU
Sample customized vertical translation table for mixed-case English with Euro character.
Note: The following five members are specific for Abend-AID. They allow browse access to diagnostic reports and source listings directly through ROSCOE or print access via a job submitted from ROSCOE to run in batch. Refer to the members for additional information.
CWROSBAT
ROSCOE sample members.
CWROSBRW
ROSCOE sample members.
CWROSCOE
ROSCOE sample members.
CWROSDIR
ROSCOE sample members.
CWROSPDF
ROSCOE sample members.
CWUTCLSE
Sample CLIST to invoke CSS online utilities with English messages and panels.
CWUTCLSJ
Sample CLIST to invoke CSS online utilities with Japanese messages and panels.
CWUTREXE
Sample REXX EXEC to invoke CSS online utilities with English messages and panels.
CWUTREXJ
Sample REXX EXEC to invoke CSS online utilities with Japanese messages and panels.
CWVFCLPT
CLIST to invoke the language processor debugging aid.
Preparing for ECC Installation
2-11
CWVFCLSE
CWVFCLSJ
Note: The debugging aid is a diagnostic tool to be used only under the supervision of Compuware Technical Support in the event of a problem related to the language processor.
Sample CLIST to invoke Compuware/VF using English messages and panels.
Sample CLIST to invoke Compuware/VF using Japanese messages and panels.
CWVFDB2
Sample CLIST to activate the File-AID DB2 interface to the Compuware
Viewing Facility.
CWVFREXE
Sample REXX EXEC to invoke Compuware/VF using English messages and panels.
CWVFREXJ
Sample REXX EXEC to invoke Compuware/VF using Japanese messages and panels.
CWVFRXPT
Sample REXX EXEC to invoke the Compuware language processor debugging aid.
Note: The debugging aid is a diagnostic tool to be used only under the supervision of Compuware Technical Support.
CXAADIRX
Abend-AID CWAASDUT DIRX sample JCL.
CXAAEXPO
Abend-AID CWAASDUT EXPORT command sample JCL.
CXAAIMPO
Abend-AID CWAASDUT IMPORT command sample JCL.
CXAAMOVE
Abend-AID CWAASDUT MOVE command sample JCL
CXALLBAA
CXALLBLP
JCL for creating sequential Abend-AID database files.
JCL for creating sequential source listing database files.
CXALLBSD
JCL for creating Abend-AID for CICS sequential transaction databases.
CXALLDAA
JCL for creating Abend-AID shared directories.
CXALLDLP
CXALLDS
CXALLMC
CXALLVAA
CXALLVLP
CXALLVS
JCL for creating Source Listing Shared Directories.
JCL to allocate a sequential DDIO file.
JCL for creating Abend-AID for CICS shared directories.
JCL for creating VSAM Abend-AID database files.
JCL for creating VSAM Source Listing Database files.
JCL to allocate a standard VSAM Abend-AID report or source listing
DDIO file.
JCL for creating Abend-AID for CICS VSAM transaction databases.
CXALLVSD
CXASM
CXASMPRE
CXC
JCL for running the Assembler language postprocessor.
JCL for running the Assembler language preprocessor.
Sample JCL for running the C postprocessor.
2-12
Enterprise Common Components Installation and Customization Guide
CXCAPTUR
CXCFGEXT
Sample JCL for creating a tape from the output of the CSS Problem
Documentation Utility.
Sample JCL to extract a source file from the configuration module in a
CSS load library.
Sample source configuration file.
CXCFGINI
CXCFGSET
CXCIREG
CXCIVSAM
Sample JCL to build a configuration module in a CSS load library, from a source configuration file you create.
Sample JCL to register the Contact Information dataset.
Sample JCL to create the Contact Information dataset.
CXCOBPRE
JCL for running the COBOL language preprocessor.
CXCOB1
JCL for the step to be added after the compile step in your current
COBOL compile and link edit JCL. This is used in order to process the compiler listing through the Compuware language postprocessor.
CXCOB2
JCL to process COBOL compiler listings stored in machine-readable format.
CXCOB99
CXCPRE
CXC2
Sample JCL for running the COBOL postprocessor.
Sample JCL for running the C preprocessor.
Sample JCL to postprocess C compiler listings stored in machinereadable format.
CXDCRADB
JCL to allocate and CREATE a multivolume Abend-AID report database.
CXDCRASD
JCL to allocate and CREATE an Abend-AID shared directory and a multivolume report database.
CXDCRLDB
JCL to allocate and CREATE a multi-volume source listing database.
CXDCRLSD
JCL to allocate and CREATE a source shared directory and a multivolume Source Listing database.
CXDCRTDB
JCL to allocate and CREATE a multi-volume transaction database.
CXDCRTSD
JCL to allocate and CREATE an Abend-AID for CICS shared directory and a multi-volume transaction database.
CXDDSUTL
Sample JCL for running the CWDDSUTL batch file utility.
CXDDUNLP
Sample JCL to execute the CWDDUNLP source extraction utility.
CXDFMAA
JCL to allocate and FORMAT a standard multi-volume Abend-AID report
DDIO file.
CXDFMSL
CXEXPORT
JCL to allocate and FORMAT a standard multi-volume source listing
DDIO file.
Sample JCL for running the CWDDSUTL EXPORT command.
CXFLAG
CXFMTAA
Sample JCL for the CWDDSUTL utility FLAG command.
Sample JCL and CWDDSUTL control statement for formatting Abend-
AID report files.
Preparing for ECC Installation
2-13
CXFMTSL
Sample JCL and CWDDSUTL control statement for formatting a source listing file.
Abend-AID for CICS CWFXSDUT DIRX sample JCL.
CXCFDIRX
CXCFEXPO
CXCFEXTL
Abend-AID for CICS CWFXSDUT EXPORT command sample JCL.
Sample JCL to export a Abend-AID for CICS transaction and a source listing to a single tape.
Abend-AID for CICS CWFXSDUT IMPORT command sample JCL.
CXCFIMPO
CXCFMOVE
Abend-AID for CICS CWFXSDUT MOVE command sample JCL.
CXIMPORT
Sample JCL for running the CWDDSUTL IMPORT command.
CXJCLSEC
CXJCLTRT
CXLPASM
CXLPC
JCL to assemble and link edit the Security Exit program.
JCL to assemble and link edit the custom translation tables.
Sample Assembler language processor options.
Sample C language processor options.
CXLPCOBB
Sample COBOL language processor options (batch programs).
CXLPCOBC
Sample COBOL language processor options (CICS programs).
CXLPDIRX
CXLPEXPO
LP source CWDDLPUT DIRX sample JCL.
LP source CWDDLPUT EXPORT command sample JCL.
CXLPIMPO
LP source CWDDLPUT IMPORT command sample JCL.
CXLPMOVE
LP source CWDDLPUT MOVE command sample JCL.
CXLPPLI
CXLPTFS
Sample PL/I language processor options.
Sample JCL to run SMPE LIST on CSS Target/Distribution zones.
CXLZAPS
Sample JCL to list the PTFs and APARs on a CSS load library
CXMODMAP
Sample JCL member to map the CSECTs in a load module.
CXOTFPRE
CXOTFPST
Sample CLIST stub for preprocessing exit for OTF
Sample CLIST stub for postprocessing exit for OTF
CXPDDSU
CXPLI
CXPLIPRE
CXPLI2
CXPRCTL
CXPRINT
CXRELS
Sample JCL to print a listing or report from a DDIO file.
JCL for running the PL/I language postprocessor.
JCL for running the PL/I language preprocessor.
JCL to postprocess PL/I compiler listings stored in machine-readable format.
IEBPTPCH control statements for job CXPRINT.
JCL to print the entire CSS installation library.
PTF/APAR tracking module. Do not modify this member.
2-14
Enterprise Common Components Installation and Customization Guide
CXR00003
CXSPRE01
CXSPST01
CXTUTOR
CXUECEXT
CXUECIN2
Sample Tutorial main menu.
Sample Skeleton for on-the-fly preprocessing.
Sample Skeleton for on-the-fly postprocessing.
Alternate Sample Tutorial main panel.
Sample CLIST for the Compile Facility JOB card exit
REXX EXEC used to invoke the Compile Information installation screens
DDIODAYS
DDIODAYJ
REXX utility to delete DDIO file members by age.
Sample JCL for running the DDIODAYS REXX utility. This utility deletes
DDIO file members by age.
File-AID DB2 Interface CLIST.
FDXTRN01
GRSRNLXX
P@CPRE01
P@CPST01
P@HPRE01
Sample GRS qname inclusion RNL.
Sample panel for preprocessing exit for on the fly.
Sample panel for postprocessing exit for on the fly.
Sample Help panel for preprocessing exit for on-the-fly processing.
P@HPST01
ATSOECLP
CSPFINIT
CSSTPCFG
Sample Help panel for postprocessing exit for on-the-fly processing.
Sample TSO logon procedure for Xpediter/TSO via Mainframe Common
Components.
Sample JCL to create and initialize the Compuware Shared Profile dataset.
Sample Mainframe Common Components TP configuration file member.
CXCFGBLD
Sample JCL to create the Mainframe Common Components configuration file dataset.
CXTPDEF
Sample HCI configuration parameters to be inserted into an existing
HCI configuration.
CXTP01
HCICFG
Sample HCI PARMLIB member for the Mainframe Common
Components TP.
Sample JCL and macros that define a total HCI configuration for the
Mainframe Common Components TP (use with a newly installed or copied HCI).
HCIJCL
HCIJOURN
HCILOAD
HCIPARM
Sample HCI start-up JCL.
Sample JCL to create the HCI journals.
Sample JCL to create the HCI configuration load library.
Sample JCL to create the HCI PARMLIB library and member.
Preparing for ECC Installation
2-15
LMS Installation Considerations
This section describes considerations for installing and customizing LMS.
APF Authorization
Following IBM system integrity guidelines, Compuware requires that your LMS load library be APF-authorized. You must provide an APF-authorized load library into which you place the modules for LMSINIT since all load modules for LMSINIT must reside in an
APF-authorized load library.
Execution Sequence
In order to ensure availability of Compuware products with LMS-controlled access, the
LMS runtime environment must be established before any of those products are initialized. For this reason, Compuware strongly recommends that you institute an MVS start-up procedure based on the sample proc provided. It should run automatically as part of IPL and IML processing prior to any procs utilized by other Compuware products.
It may be necessary to consult your site’s MVS system programmer.
The License Management System Functions
The License Management System has three basic functions.
License Management Administration
You will create and maintain your License File using the License Administration Utility
(LAU) installed with your License Management Software. Your License File is used as the source from which Compuware products will validate access for your site. When you receive License Certificates for Compuware products, your organization’s License
Administrator must use the LAU to import the License Certificates into the License File.
Additional features of the LAU assist in the maintenance of your License Files. In addition to browsing the License Certificates in your License File, you may run a number of administrative reports from the LAU. These reports will reveal the contents of your
License File, from a number of perspectives, allowing you to determine the state of the
License Certificate for any particular Compuware product release.
Depending on the requirements of your organization, you may have more than one
License File. Each License File can be centrally administered from the License
Administration Utility.
In addition to using the LAU to administer licenses in individual license files, an optional feature called the Centralized Licensing Facility (CLF) can be used to manage your licensing environment from a single z/OS system regardless of where your production or test LPARs reside. Please see the License Management System User/Reference Guide—Centralized
Licensing Facility for more information about CLF.
Establishing the Runtime LMS Environment
You will use the License Files created and maintained by the License Administration
Utility as input to a program that establishes your Compuware LMS runtime environment. This program is named LMSINIT. LMSINIT is the License Management
System program that reads the License File
1
and constructs the License Cache and
License Management System subsystem against which Compuware product runtime license access requests are later made.
1. LMSINIT can read more than one License File if you are an organization that administers Compuware product access for more than one Compuware customer.
2-16
Enterprise Common Components Installation and Customization Guide
Important: You must re-establish your runtime License Management System environment at each IPL, and whenever you have an update to your License File, the update must be made available to your z/OS systems. At IPL startup, LMSINIT must be completed before starting up any Compuware product.
Validating Product Access Requests During Product Use
Your access to your Compuware products will be validated when you use your
Compuware products. The Compuware product will make a request of the License
Management System to determine if your site has a valid License Certificate for the product release. The requests are made by the product at various times during its execution depending on the product’s needs. The Compuware product will access the
LMS subsystem established, request License File information and act upon the information. If the License Certificate information is valid, users will proceed with their use of the product without disruption. Any abnormal License Management event detected will be reported to the product’s user and may optionally be reported by e-mail to your organization’s License Administrator. The disposition and frequency of the reporting of these events can be controlled by the customer using the "Message
Suppression and Distribution" feature of LMS. See the License Management System
User/Reference Guide—Centralized Licensing Facility for more information about this feature.
Optionally, these events may also be recorded in SMF Logging.
Note: LMSINIT can read more than one License File if you are an organization that administers Compuware product access for more than one Compuware customer.
HCI Installation Considerations
This section describes considerations for installing the Host Communications Interface which is a requirement for Distributed Viewing Support and Abend-AID for CICS.
APF Authorization
The HCI component library (COMPWARE.MLHCnnn.SLHCAUTH) must be APFauthorized. This library is used in the server region for Abend-AID Distributed Viewing
Support and Abend-AID for CICS (with or without DVS) as well as functions for other
Compuware products. See Table 2-1 on page 2-1 for the specific products.
TSO Logon PROCs
If you are utilizing Abend-AID Distributed Viewing Support via the Compuware Viewing
Facility, you should update the CWVFCLSE, CWVFCLSJ, CWVFREXE, and CWVFREXJ members to add the HCI library to the ISPLLIB concatenations
(COMPWARE.MLHCnnn.SLHCLOAD). It may also be added to your TSO logon PROC or
added to the link list. For more information, see “Step 5. Activate Compuware ISPF
Download