SMP/E Installation Using GUI Interface. Compuware ECC
विज्ञापन
विज्ञापन
A-1
Appendix A.
SMP/E Installation Using GUI Interface
Appendix A.
Note: Compuware recommends using the Receive From Network (RFN) installation procedures to SMP/E install the product files. Follow the instructions in this
appendix only if you cannot perform an RFN installation. See Chapter 3,
“Receive From Network (RFN) Installation” for more information.
IMPORTANT:
If the current release of the ECC components exists on your system, select the
Maintenance Only checkbox in the file upload dialog executed on your PC. This will upload the maintenance, HOLDDATA, and abstract files to your mainframe.
See Chapter 4, “Applying Maintenance”.
CAUTION:
To prevent possible conflicts, Compuware strongly recommends that all
Compuware products and components distributed via SMP/E share a single
Global zone reserved solely for Compuware products. Target and distribution zones should not be shared with other products or different releases of the same product.
This chapter explains the steps required to install the primary portions of Compuware’s
Enterprise Common Components (ECC), including:
• Compuware Shared Services (CSS)
• License Management System (LMS)
• Host Communications Interface (HCI)
The procedures in this chapter unload the ECC media and install the components into datasets. Although the full ECC installation procedure is discussed in this chapter, you may only need to perform certain portions depending on which products are used at your site. You should already have determined in the previous chapter which components you need to install.
Except where otherwise noted, the return code from all jobs should be zero.
The ECC installation process utilizes System Modification Program Extended (SMP/E).
For more information about this type of installation, and other installation
considerations, please refer to Chapter 2, “Preparing for ECC Installation”. For more
information about SMP/E, consult the IBM SMP/E Reference or the IBM SMP/E User’s Guide.
Notes:
1. If you have previously installed components from an ECC release, some of the values displayed on the install panels may be populated from values stored in the installing user’s TSO profile. Please verify each panel carefully before continuing.
2. Approved PTFs are normally added to the Enterprise Common Components CD on a monthly basis. If you receive more than one CD dated within a given month, the
maintenance on these CDs may be identical. See Chapter 4, “Applying Maintenance”
for complete maintenance installation instructions.
A-2
Enterprise Common Components Installation and Customization Guide
Upload Product Files and Perform SMP/E Installation
Compuware provides a convenient way to upload product files and perform an SMP/E installation, all from a straightforward PC workstation interface. When you insert the product media for mainframe Extended Play (EP) products (or double-click the Setup.exe file from an electronic distribution), the product Setup dialog box appears. You can use this interface to upload product installation and/or maintenance files to the mainframe and perform a full SMP/E installation.
Notes:
• Some product media do not support SMP/E installation. Such media can be easily identified by the absence of the SMP/E Install tab on the Setup dialog box’s
Mainframe Products tab. If your product media does not contain the SMP/E Install tab, skip these instructions and go to the appropriate appendix in the product’s
Installation Guide that contains upload and installation instructions for non-SMP/E media.
• If you prefer using a mainframe TSO session to complete the SMP/E installation or application of maintenance, go to the appropriate appendix in the Installation Guide for the product you are installing and continue with the instructions there.
• You may optionally upload the files only, including all SMP/E installation JCL, and then use a mainframe session to perform the SMP/E installation.
The interface also includes a tab for contacting Compuware Customer Support and may include tabs for Windows
®
products and third-party products. For more information, see
“Install Windows and Third-Party Products” on page A-11.
System Requirements and Preparation
Before using the upload/installation interface, make sure your system meets the following requirements:
• Internet Explorer 6.0 or above
• Adobe Reader 6.0 or above to view PDF documents
• If your PC’s display DPI setting makes the interface difficult to view, temporarily set it to Normal size (96 DPI).
Firewall Settings
Either configure software firewalls running on your PC to grant the upload application
(cwftpw.exe located in folder \cpwr of the media) network access to your mainframe, or disable firewalls during the upload.
Information on the Media Label
If you are installing from physical media, the media label provides information about installation or operating capability, as noted below:
Name/Release
Name and release of the product.
Creation
The product’s installation media label shows when it was made. Compare this creation date with any maintenance posted on the Compuware Go customer support
Website at http://go.compuware.com.
If additional maintenance has become available since the date on the installation media, either download the maintenance, or call Customer Support to request new installation media with the current maintenance.
SMP/E Installation Using GUI Interface
A-3
Select Items for Upload
IMPORTANT: Sample Xpediter Setup dialog boxes are shown in this section, but the steps are applicable to other Compuware mainframe products.
In addition to installation, maintenance, and documentation files, the product media (or electronic distribution) contains an HTML-based upload/installation application used to
FTP-transfer the necessary files to your mainframe.
1. Insert the media into the drive or double-click Setup.exe. A product Setup dialog box similar to that shown in Figure A-1 appears. The Mainframe Upload tab of the
Mainframe Products tab is shown first. Fields marked with an asterisk (*) are required.
Figure A-1. Mainframe Upload Dialog, Upper Portion
Note: Do not click the Upload Product Files button until all required fields have been filled in.
2. Following your site’s standards, enter a value in the High Level Qualifier for
Common Files field. Common files are datasets that can be used across multiple products on the EP and may include maintenance files, MCS files, and sample libraries. The default high level qualifier is SYS1.CPWR.COMMON. If you do not have ALTER access to this hlq, you must change it to a qualifier you can create files under.
3. Select the files to be uploaded as follows:
– If you want to upload files for all of the products listed, use the All row as follows:
1. Click either the Product and Maintenance check box or the Maintenance
only check box.
2. Enter an appropriate qualifier in the Unload High Level Qualifier field. Be sure you are allowed to create files under this qualifier.
A-4
Enterprise Common Components Installation and Customization Guide
Note: The ISPF SMP/E JCL generation dialogs are currently designed to handle only a Common Unload High Level Qualifier. If you plan to use the mainframe ISPF dialog to generate SMP/E JCL for more than one product, you must use the same upload hlq for all of them. This restriction does not apply if you are planning to use the Setup dialog box’s SMP/E Install tab to generate installation JCL.
– If you want to upload a selected combination of product and/or maintenance files, use the individual product rows as follows:
Note: Some products may require a component that is common to multiple products. For example, if you select Abend-AID and/or Abend-AID for
CICS, you should also select Abend-AID Base Services.
1. Click either the Product and Maintenance check box or the Maintenance
only check box for each product you want to install or apply maintenance to.
2. Optionally, click the Japanese Support check box if you plan on installing localized or Japanese language support.
3. Optionally, enter an appropriate qualifier in the product Unload High Level
Qualifier field. If the product is not selected for upload, this field will be ignored. If this field is cleared, it will be reset to the default value.
4. Scroll down to view the lower portion of the dialog box as shown in Figure A-2.
5. Edit the sample information in the Job Card field as required.
Note: The job class specified must allow enough CPU time for long-running jobs.
Running the SMP/E APPLY and ACCEPT steps will result in the generation of a large amount of output. Be sure to set your job card Class and Lines parameters accordingly.
Figure A-2. Mainframe Upload Dialog, Lower Portion
SMP/E Installation Using GUI Interface
A-5
Enter File Transfer Settings
1. In the Mainframe FTP Information area, specify the values to be used during FTP transfer of the product installation and maintenance files as follows:
– In the Host field, enter your host mainframe’s IP or DNS name.
– In the User Id field, enter the TSO user ID to use for the FTP session.
– In the Password field, enter the password associated with the TSO user ID above.
– In the Port field, enter the number of the host port used for FTP uploads and downloads. The default is 21.
– In the Dasd Unit field, enter the esoteric unit to delete temporary upload files.
The default is SYSDA.
2. (Optional) Specify the storage options to be used on the mainframe as follows:
– In the Volume field, enter the name of the volume on which to place the uploaded files. Be sure the target volume has enough space to hold all the files uploaded.
Note: Click the File Size button to display an estimate of the minimum number of tracks required to upload the selected products. The estimate assumes
3390 DASD and will be less accurate for different DASD. Compuware recommends adding 5% to the estimated minimum tracks value.
– If using SMS, enter the appropriate class to apply to the uploaded files in the SMS
Storage Class field.
Upload Files
When the desired installation and/or maintenance files have been selected and all required fields have been filled in, click Upload Product Files to upload the selected files in TSO XMIT format, along with the JCL to perform a TSO RECEIVE of the files.
The upload/installation application uploads the required files to your mainframe. The name of the file containing the JCL to TSO RECEIVE the files is shown at the bottom of the screen.
Note: The Compuware EP Setup upload confirmation dialog may include one or more messages indicating the upload status of Common file set n. The upload of
Common file set 0 normally includes UNLOAD, UPLDEL, and SMPE.DATA files.
Other files may also be uploaded, depending on the design of the EP.
Enter SMP/E Settings
Notes:
• If you prefer using a mainframe TSO session to complete the SMP/E installation or application of maintenance, go to the appropriate appendix in the Installation Guide and continue with the instructions there.
• At the end of the SMP/E install process below, if you click Upload SMP/E JCL to the
Mainframe and SUBMIT, the TSO RECEIVE discussed above is executed automatically as part of the SMP/E install.
The products’ Setup dialog box enables SMP/E installation of the selected product and/or maintenance files directly from your PC.
1. Click the SMP/E Install tab. The dialog shown in Figure A-3 appears, listing the product installation and/or maintenance files you uploaded previously.
A-6
Enterprise Common Components Installation and Customization Guide
Figure A-3. SMP/E Install Dialog, Upper Portion
Note: Do not click either of the Upload SMP/E JCL to the Mainframe buttons until all required fields, including those under SMP/E Options, have been filled in. Be sure to use names or hlq that you have UPDATE or ALTER access for as necessary.
2. Specify the basic values to be used during the SMP/E process as follows:
– In the Compuware GLOBAL CSI Dataset field, enter the name of the CSI dataset used for Compuware products. The default is SYS1.CPWR.GLOBAL.CSI.
– Click the appropriate button under Does the Global CSI already exist? depending on whether the CSI exists and, if so, whether it has been set up for
Compuware use.
– In the HLQ for Compuware SMP/E Datasets field, enter the high-level qualifier to be used for the SMP/E datasets on the mainframe. The default is
SYS1.CPWR.GLOBAL.
– In the Compuware Products High-level qualifier field, enter the high-level qualifier associated with the products to be installed. The default is SYS1.CPWR.
Note: The value entered in this field becomes the default for the High Level
Qualifier fields on the Zone Info part of the screen in the next step. Any
HLQ you enter there will override the default value for installing that specific product.
– In the DASD Unit field, enter the appropriate symbolic unit. The default is
SYSDA.
– (Optional) In the DASD Volser field, enter the appropriate storage volume serial information. Be sure the target volume has enough space to hold all your files.
– In the SMP/E Work Unit field, enter the name of the appropriate SMP/E work symbolic unit. The default is SYSDA.
SMP/E Installation Using GUI Interface
A-7
3. Click the plus (+) sign next to SMP/E Options to expand that area of the screen as shown in Figure A-4.
Figure A-4. SMP/E Install Dialog, SMP/E Options Area
4. Click the plus sign next to Zone Info. The SMP/E target and distribution zone fields shown in the upper part of Figure A-5 appear. For each item listed, edit the values in the Target Zone Name, Distribution Zone Name, and each of the High Level
Qualifier fields, as necessary. The High Level Qualifier fields default to the value in the Compuware Products High-level qualifier field, but you can enter override values on a product-by-product basis.
A-8
Enterprise Common Components Installation and Customization Guide
Figure A-5. SMP/E Install Dialog, Zone Info and System Utilities Portion
5. Click the plus sign next to System Utilities. The utilities fields shown in the lower part of Figure A-5 appear. Standard defaults are pre-filled. For each item listed, enter the applicable value as required.
6. Click the plus sign next to SMS parameters. The parameters fields shown in the upper part of Figure A-6 appear. Enter the data class, storage class, or management class SMS parameters for SMP/E datasets if they are required at your site.
SMP/E Installation Using GUI Interface
A-9
Figure A-6. SMP/E Install Dialog, SMS Parameters and Dataset Definitions Portion
7. Click the plus sign next to Cross-Product and/or Non-Compuware Dataset
Definitions. Dataset Name fields similar to those shown in the middle part of Figure
A-6 appear. Enter the appropriate DSN for each dataset listed. If you are installing individual products or maintenance only, you may not need to enter values for all
DSNs.
Note: DevEnterprise requires a DSN for the Host Communications loadlib (SLHCLOAD), and if that field is left blank, a message may appear. If you are installing
DevEnterprise, click Cancel, enter a DSN for SLHCLOAD, and retry the upload.
Otherwise click OK to dismiss the message and continue with the installation.
8. If necessary, edit the sample information in the Job Card field as required.
9. Make any necessary revisions to the Mainframe FTP Information fields.
Upload and Submit Installation Jobs
When the desired items on the SMP/E Install tab have been selected and all required fields have been filled in, do one of the following:
• Recommended: To upload the JCL and submit it immediately to initiate the SMP/E process, click Upload SMP/E JCL to the Mainframe and SUBMIT.
• Optional: To upload the JCL to be submitted manually later, click Upload SMP/E
JCL to the Mainframe. You will need to use a mainframe TSO session to complete the SMP/E installation or application of maintenance. Go to the Installation Guide appendix entitled “Installing Enterprise Common Components Using ISPF” and continue with the instructions there.
The upload/installation application uploads the required files to your mainframe and, if
SUBMIT was clicked, initiates the SMP/E installation procedure.
A-10
Enterprise Common Components Installation and Customization Guide
Continue the installation and product configuration process below. For the most current installation instructions and Release Notes, visit the Compuware Go customer support
Website at go.compuware.com.
SMP/E JCL Uploaded to the Mainframe
When SMP/E installation generation is done from the PC using the upload/installation application rather than using the ISPF Installation JCL Customization Facility, dataset
<hlq>.<prodid>.SMPE.JCL
is uploaded to the mainframe. This dataset contains the JCL used to perform an SMP/E installation, along with jobs that process maintenance files
(uploaded from media or downloaded from Compuware Go).
*$01GLCSI 1. Allocate the SMPLOG and SMPPTS datasets.
2. Define a VSAM cluster for use as a separate global CSI for installing
Compuware products, then load the SMP/E initialization record
(GIMZPOOL) into it.
3. Initialize the global CSI with appropriate Zonedef, option, and DDDEF entries.
* Depending on the selection made in the upload/installation application, this member may not exist, or items 1 and 2 may be bypassed.
$02TZCSI
$03ALDSN
$04RECV
$05APPLY
$06ACCPT
$07SUBMT
$10MNTJB
$14MRECV
$15MAPLY
$16MACPT
2. Delete and define the target and distribution zone clusters and support files.
3. Update the global CSI with component specific Zonedef, option, and
DDDEF entries.
4. Initialize the product target and distribution zone CSIs with DLIBZONE,
TARGETZONE, option, and DDDEF entries.
1. Delete any existing SMP/E libraries and datasets.
2. Allocate the SMP/E libraries and datasets.
Receive the base code and maintenance PTFs
Apply base code and maintenance PTFs into target SMP/E libraries.
Accept base code into the SMP/E distribution libraries.
Note: Use job $16MACPT to accept maintenance PTFs.
This jobstream is the JCL that is submitted when Upload SMP/E JCL to the
Mainframe and Submit is clicked. It is a concatenation of the above members (minus extra jobcards) into a single member.
This jobstream is the JCL that is submitted when Upload SMP/E JCL to the
Mainframe and Submit is clicked and Maintenance Only is selected. It is a concatenation of members $14MRECV and $15MAPLY (minus extra jobcards) into a single member.
This jobstream receives the maintenance file(s) for installed components.
Update JCL statements SMPPTFIN and SMPHOLD to point to the files uploaded from the media, electronic distribution, or Compuware Go (or downloaded from FTP).
This jobstream will apply the maintenance PTFs to the SMP/E files
This jobstream will accept the maintenance PTFs to the SMP/E files
SMP/E Installation Using GUI Interface
A-11
Upload/Installation FAQs
What should I do if I receive a message stating that I am not an Administrator and cannot perform product installation?
For Windows releases prior to Windows 7, this message can be ignored. You do not need
Administrator rights because nothing is being installed on your PC from the media. The upload/installation application simply facilitates the upload of files to the mainframe and, optionally, their installation there.
Windows 7 users with User Account Control (UAC) settings higher than Never notify must have administrator privileges on their PC—or have access to an ID and password with administrator privileges—to run the upload/installation application.
What should I do if I receive a message stating “Install Program As Other User”?
Select Run the program as your-domain\your-domain-id and click OK to continue.
Nothing is installed on your PC. The upload/installation application simply facilitates the upload of files to the mainframe and, optionally, their installation there.
What should I do if I receive a message stating “Error: You must have a supporting browser”?
Install Internet Explorer 6.0 or above and set it as your default browser. Contact your
System Administrator for more information.
What should I do if I receive a message stating “Cannot connect to host xxxxx:nn”?
The host name or remote port you specified on the Mainframe Upload dialog is incorrect.
Contact your System Administrator for the host ID of the mainframe. The host name is the domain name or IP address of the mainframe. It may be the LPAR system ID or it may be some other name.
What should I do if the upload is slow, doesn’t complete, or I receive a number of transfer-retry messages?
Windows firewall and third-party firewalls can cause numerous retries and time-outs. All firewalls should either be configured to allow the upload application access to the mainframe or they should be disabled during the upload process.
What should I do if I am using Windows 7, and a Program Compatibility Assistant dialog box appears after I close the product Setup dialog box?
You can simply click Cancel to dismiss the dialog box. To prevent it from reappearing the next time you close the product Setup interface, click This program installed correctly instead. Note that the dialog box may reappear when using subsequent product distributions.
What should I do if I can’t view some or all of the documentation?
Adobe Reader 6.0 or above is required to view and use the PDF/PDX files. You may be able to view the PDF files with an older version. However, you will not be able to use a PDF index file (.pdx), which significantly speeds searches and allows you to search the entire set of documents at once. Download a free copy of the reader from www.adobe.com.
Install Windows and Third-Party Products
The same Extended Play (EP) Setup dialog box that allows you to upload and install mainframe products (see “Upload Product Files and Perform SMP/E Installation” on page
A-2) also includes a Contact Us tab for contacting Compuware Customer Support and
may include tabs for Windows
®
products and third-party products.
A-12
Enterprise Common Components Installation and Customization Guide
Installing Windows Products
When you insert the product media for mainframe EP products (or double-click the
Setup.exe file from an electronic distribution), the products’ Setup dialog box appears.
Click the Windows
®
Products tab. A dialog box similar to the one shown in Figure A-7 appears. Use the links and follow the on-screen prompts to install the desired software.
Figure A-7. Windows
®
Products Tab
Installing Third-Party Products
Click the 3rd Party Products tab. A dialog box similar to the one shown in Figure A-8 appears. Use the links and follow the on-screen prompts to install the desired software.
Figure A-8. 3rd Party Products Tab
डाउनलोड
विज्ञापन